Resumo:
The aim of the present study was to assess the effectiveness and adverse effects on dental enamel caused by nightguard vital bleaching with 10% carbamide peroxide. This was accomplished through the interaction of researchers from different areas such as dentistry, materials engineering and physics. Fifty volunteers took part in the doubleblind randomized controlled clinical trial. They were allocated to an experimental group that used Opalescence PF 10% (OPA) and a control group that used a placebo gel (PLA). Fragments of human dental enamel from the vestibular surface of healthy premolars, extracted for orthodontic reasons, were fixed to the vestibular surface of the first upper molars of the volunteers for in situ observation. Bleaching was performed at night for 21 days. The observation periods included Baseline (BL), T0 (21 days), T30 (30 days after treatment) and T180 (180 days after treatment, only for the OPA group). Tooth color was assessed by comparing it with the Vita® scale and by the degree of satisfaction expressed by the volunteer. We also assessed adverse clinical effects, dental sensitivity and gingival bleeding. The study of adverse effects on enamel was conducted in vivo and in situ, using the DIAGNOdent® laser fluorescence device to detect mineral loss. Scanning electron microscopy (SEM) was used to check for superficial morphological alterations, energy dispersive spectrophotometry (EDS) to semiquantitatively assess chemical composition using the Ca/P ratio, and the x-ray diffraction (XRD) technique to observe alterations in enamel microstructure. The results showed that nightguard vital bleaching with 10% carbamide peroxide was effective in 96% of the cases, versus 8% for the PLA group. Dental sensitivity was present in 36% (9/25) of the cases. There was no significant association between gingival bleeding and the type of gel used (p = 1.00). In vivo laser fluorescence analysis showed no difference in values for the control group, whereas in the OPA group there was a statistically significant difference between baseline values in relation to the subsequent periods (p<0.01), with lower mean values for post-bleaching times. There was a significant difference between the groups for times T0 and T30. Micrographic analysis showed no enamel surface alterations related to the treatment performed. No significant alteration in Ca/P ratio was observed in the OPA group (p = 0.624) or in the PLA group (p = 0.462) for each of the observation periods, nor between the groups studied (p=0.102). The XRD pattern for both groups showed the presence of three-phase Hydroxyapatite according to JCPDS files (9-0432[Ca5(PO4)3(OH)], 18-0303[Ca3(PO4)2.xH2O] and 25-0166[Ca5(PO4)3(OH, Cl, F)]). No other peak associated to other phases was found, independent of the group analyzed, which reveals there was no disappearance, nucleation or phase transformation. Neither was there any alteration in peak pattern location. With the methodology and protocol used in this study, nightguard vital bleaching with 10% carbamide peroxide proved to be an effective and safe procedure for dental enamel
Resumo:
The objective of this clinical study was to evaluate the effectiveness of the toothbrushing with and without fluoride and the daily fluoride rinse (NaF 0.05%) on produced white spot, in vivo. This was a clinical study, controlled, randomized and triple blind. Thirty patients were selected for orthodontics reasons from Orthodontics Specialization Course at the Brazilian Dental Association - Section of Rio Grande do Norte. In this study it was used 4 bicuspid upper and lower. They had orthodontic reason for extractions, in 35 days, at least. The sample had one hundred and twenty teeth that received orthodontic bands. The bands were fixed with polycarboxylate cement, and there was a space standardized between bands and one surface of teeth. The four bicuspid of each patients were randomized and nominated as A, B, C and D. These nominations determinated the sequence of the extractions and what was done in each tooth. All the patients had been submitted to the toothbrushing with or without fluoride for 35 days. After this period, the A tooth of each patient was extracted to serve as control. The others teeth (B, C and D) were extracted one by each week. The entire sample was analyzed through the clinical examination and by laser fluorescence (DIAGNOdent®) in three different times: before orthodontic bands, 28 days after fixed and then removed the bands and, the last one, 07 days after one of the three treatments (toothbrushing with or without fluoride, tooth paste with fluoride and mouth rinse with fluoride). At the beginning all groups (A, B, C and D) had the same conditions, no significant difference was found. The same situation was found in a clinical examination. The results of the DIAGNOdent® for the groups that used tooth paste without fluoride, with fluoride and mouth rinse with fluoride, after 28 days, there was no significant difference. Clinically, the white spot was formed in all teeth after 28 days. When it was compared the three treated groups, the group without fluoride in tooth paste had worst result than the others groups. But there was no significant association between the number of active and inactive white spots and the type of treatment that the teeth had received. The demineralization of the enamel surface, under the orthodontic bands, it happened in a few weeks. The exposition of the white spots in oral environmental resulted in an improvement, but it was not enough to return to the values from the base line, either for the toothbrushing and/or the use of fluorite mouth rinse. Mouth rinse and toothpaste with fluoride have showed to reduce the incidence of demineralization in the enamel, but none seems to be superior to another one in an in vivo study
Resumo:
The objective of this Doctoral Thesis was monitoring, in trimestral scale, the coastal morphology of the Northeastern coast sections of Rio Grande do Norte State, in Brazil, which is an area of Potiguar Basin influenced by the oil industry activities. The studied sections compose coastal areas with intense sedimentary erosion and high environmental sensitivity to the oil spill. In order to achieve the general objective of this study, the work has been systematized in four steps. The first one refers to the evaluation of the geomorphological data acquisition methodologies used on Digital Elevation Model (DEM) of sandy beaches. The data has been obtained from Soledade beach, located on the Northeastern coast of Rio Grande Norte. The second step has been centered on the increasing of the reference geodetic infrastructure to accomplish the geodetic survey of the studied area by implanting a station in Corta Cachorro Barrier Island and by conducting monitoring geodetic surveys to understand the beach system based on the Coastline (CL) and on DEM multitemporal analysis. The third phase has been related to the usage of the methodology developed by Santos; Amaro (2011) and Santos et al. (2012) for the surveying, processing, representation, integration and analysis of Coastlines from sandy coast, which have been obtained through geodetic techniques of positioning, morphological change analysis and sediment transport. The fourth stage represents the innovation of surveys in coastal environment by using the Terrestrial Laser Scanning (TLS), based on Light Detection and Ranging (LiDAR), to evaluate a highly eroded section on Soledade beach where the oil industry structures are located. The evaluation has been achieved through high-precision DEM and accuracy during the modeling of the coast morphology changes. The result analysis of the integrated study about the spatial and temporal interrelations of the intense coastal processes in areas of building cycles and destruction of beaches has allowed identifying the causes and consequences of the intense coastal erosion in exposed beach sections and in barrier islands
Resumo:
A laserterapia de baixa potência (LBP) tem demonstrado recentemente ser capaz de aumentar a resistência à fadiga, bem como potencializar o desempenho neuromuscular através de seus efeitos metabólicos e fotoquímicos. Estudos anteriores mostraram que o LBP reduziu o estresse oxidativo do exercício, promovendo um retardo da fadiga muscular e minimizando seus efeitos deletérios. O objetivo desse estudo foi avaliar se a aplicação do LBP antes de um protocolo de fadiga teria efeito sobre o desempenho neuromuscular nas variáveis eletromiográficas e dinamométricas do músculo sóleo em sujeitos saudáveis. Esta pesquisa caracterizou-se como um estudo experimental do tipo ensaio clínico controlado, randomizado e cego, no qual participaram 60 voluntários de ambos os sexos, com faixa etária entre 18 e 28 anos e fisicamente ativos, segundo o questionário internacional para a prática de atividade física (IPAQ). Os sujeitos foram alocados randomicamente em três grupos: Controle (G1), Placebo (G2) e Laser (G3) e todos os voluntários foram submetidos a uma avaliação inicial (AV-1), um Protocolo de Fadiga e uma avaliação final (AV-2), compostas por contrações isocinéticas para flexão plantar a uma velocidade de 90°/s. Os resultados encontrados nesse estudo mostraram que não houve diferença estatística entre os três grupos da pesquisa nas variáveis eletromiográficas de RMS e Frequência Mediana, contudo, em relação à dinamometria, o grupo que recebeu a aplicação do Laser obteve um índice de fadiga significativamente menor (p=0,04) quando comparado aos grupos Controle e Placebo. Além disso, a aplicação do laser pré-exercício também resultou em um aumento nas variáveis de desempenho potência e trabalho. Com isso, pode-se concluir que o LBP foi capaz de melhorar o desempenho do sóleo em sujeitos saudáveis, justificado pelo aumento da resistência à fadiga
Resumo:
Many studies have been made to understand the process of tissular cicatrization, as well as the possible effects of laser therapy in the wound healing. However, the influence of low frequency laser irradiation in the repairing process is not completely understood. Our study has the purpose to assess clinically the effect of postoperative irradiation of the low frequency laser in humans, and the gingival repairing process postgingivoplasty performed with the extern bevel technique. Twenty-four patients with inflammatory gingival hyperplasia were enrolled in this study, which did not reduce with basic periodontal procedures, and patients with melanin pigmentation, with esthetic indications. After surgery the test group, randomly selected by a drawing, received laser application with energy density of 4 J/cm2, immediately after surgery and each 48 hours, during a week, with a total of 4 sections. The control group did not receive irradiation. The visual clinical analyses were performed by a single blind examiner, in the 2nd, 4th, 6th, 8th, 15th and 21st days post surgery. For statistic analyses of the data was used a Q-square test. Concerning the color, the results showed a better wound healing during days 6 to 8. when assessed the degree of progress of surgical wound, the results showed that the test group had a better cicatrization compared with the control group in the 2nd, 6th, 8th and 15th days post surgery, and at the 21st day both groups had the same results. Our results confirm that the laser had clinical influence in the repairing process after gingivoplasty surgery during days 2 to 15 post surgery
Resumo:
Esse estudo se propôs a avaliar um método auxiliar de diagnóstico (DIAGNOdent®) na predição de cárie de dentina em dentes decíduos, através de validação histológica e de microdureza. Verificando possíveis diferenças entre os valores obtidos através do método auxiliar, além de determinar um ponto de corte para parada de remoção de tecido cariado. A amostra do estudo foi de 15 crianças que apresentaram 21 cavidades de cárie, tratadas e analisadas desde antes da realização da restauração até quando da exodontia do elemento dentário. Os espécimes foram analisados através do DIAGNOdent® antes da abertura das cavidades, após a remoção do tecido cariado e depois da reabertura das cavidades que se deu após a exodontia dos elementos dentários. Posteriormente, receberam preparo metalográfico para realização de testes de microdureza e microscopia óptica que serviram como forma de validação para as mensurações obtidas pela fluorescência a laser. Houve diferença significativa entre os valores DIAGNOdent® encontrados antes da abertura da cavidade e os demais (p < 0,0001). Havendo correlação significativa (r = 0,432 ; p = 0,019) apenas para as aferições obtidas antes da abertura das cavidades e quando do término da remoção do tecido cariado. Para a microdureza, as médias axiais foram significativamente maiores que as pulpares, existindo correlação entre a microdureza pulpar e os valores do DIAGNOdent® após a reabertura (r = - 0,472 ; p = 0,002). Valores de 15,38% para a sensibilidade, 100% para a especificidade, 100% para o valor preditivo positivo e 71,79% para o valor preditivo negativo, foram obtidos quando se utilizou um ponto de corte de 30 para fluorescência a laser, tendo como padrão-ouro a microdureza pulpar. Partindo da média dos valores de fluorescência a laser obtidos após a remoção do tecido cariado e acrescentando-se um desvio-padrão a esta, o método indicou o valor de 19 como ponto de corte para cessar a remoção de dentina. Concluiu-se que, nas condições analisadas, o método auxiliar de diagnóstico (DIAGNOdent®) é um método acurado na predição de cárie de dentina em dentes decíduos. Além disso, o método comprovou que o padrão usual de remoção de dentina garante a remoção do tecido cariado
Resumo:
Dental caries consists in a multifactorial and dynamic process. The knowledge of the ionic interactions among dental tissues and dental biofilm make possible its understanding as a process that can be stopped. Recently, the use of sealants have lost its function as preventive agent and passed to be argued as a possible therapeutical agent. This happens by hindering the substratum flow to the lesion inner and, therefore, controls the advance of the process. This study aimed to evaluate glass ionomer cement as a not invasive technique of treatment in occlusal caries without clinical cavitation, but with dentinal involvement. The research was accomplished using a controlled clinical trial with two groups (experimental and control) in 38 subjects (8-18 years) with 51 molars. The teeth of the experimental group were sealed with glass ionomer cement (Vidrion-R, S.S.White, Juiz de Fora, Brazil) and the molars control did not suffer intervention. The experimental group was followed by a year and the control by 8 months due the progression of the carious injury. Both groups were reevaluated to each 4 months with the use of clinical, radiographic and laser fluorescence (DIAGNOdent®) examination. The analysis of the clinical evaluation did not observe a significant difference between experimental and control groups. However, analysis with radiographic and laser fluorescence (DIAGNOdent®) examination observed a significant difference (p> 0,05) between groups, demonstrating a wors condition to the group without intervention. The results suggest that glass ionomer cement as sealant can be efficient to paralyze dentinal caries without clinical cavitation