2 resultados para Cortina, Adela

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is presented the analysis of a retaining wall designed for the basement of a residential building, located in Natal/RN, which consists in a spaced pile wall, anchored by tiebacks, in sand. This structure was instrumented in order to measure the wall s horizontal movements and the load distribution throughout the anchor fixed length. The horizontal movements were measured with an inclinometer, and the loads in the anchors were measured with strain gages, installed in three places throughout the anchor fixed length. Measurements for displacement were done right after the implementation of each stage of the building and right after the conclusion of the building, and the measurements for loads in the anchors were done during the performance test, at the moment of the locking off and, also, right after the conclusion of the building. From the data of displacement were obtained velocity and acceleration data of wall. It was found that the time elapsed on braced installation was decisive in the magnitude of the displacements. The maximum horizontal displacement of wall ranged between 0,18 and 0,66% of the final depth of excavation. The loads in the anchors strongly reduced to approximately half the anchor fixed length, followed an exponential distribution. Furthermore, it was found that there was a loss of load in the anchors over time, reaching 50% loss in one of them

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A numerical study on the behavior of tied-back retaining walls in sand, using the finite element method (FEM) is presented. The analyses were performed using the software Plaxis 2D, and were focused on the development of horizontal displacements, horizontal stresses, shear forces and bending moments in the structure during the construction process. Emphasis was placed on the evaluation of wall embedment, tie-back horizontal spacing, wall thickness, and free anchor length on wall behavior. A representative soil profile of a specific region at the City of Natal, Brazil, was used in the numerical analyses. New facilities built on this region often include retaining structures of the same type studied herein. Soil behavior was modeled using the Mohr-Coulomb constitutive model, whereas the structural elements were modeled using the linear elastic model. Shear strength parameters of the soil layers were obtained from direct shear test results conducted with samples collected at the studied site. Deformation parameters were obtained from empirical correlations from SPT test results carried out on the studied site. The results of the numerical analyses revealed that the effect of wall embedment on the investigated parameters is virtually negligible. Conversely, the tie-back horizontal spacing plays an important role on the investigated parameters. The results also demonstrated that the wall thickness significantly affects the wall horizontal displacements, and the shear forces and bending moments within the retaining structure. However, wall thickness was not found to influence horizontal stresses in the structure