Resumo:
In this work, AISI 1010 steel samples were plasma nitrided into 20% N 2 100 Pa and 400 Pa for N 2 and H 2 , respectively), temperatures of 500 and 580 °C, during 2 h. Three different procedures for cooling were accomplished after nitriding. In the first procedure the cooling occurred naturally, that is, the sample was kept on substrate holder. In the second one the sample was pulled off and cooling in a cold surface. Finally, in the third cooling process the sample was pulled off the substrate holder down into special reservoir filled with oil held at ambient temperature. The properties of the AISI 1010 steel samples were characterized by optical and electron microscopy, X-ray diffraction, Mössbauer spectroscopy and microhardness tests. Thermal gradient inside the sample kept on substrate holder during cooling process was measured by three inserted thermocouples at different depths. When samples were cooled rapidly the transformation of ϵ-Fe 2 − 3 N to γ′-Fe 4 N was inhibited. Such effect is indicated by the high concentration of ϵ-Fe compound zone. To get solid state solution of nitrogen in the diffusion zone, instead of precipitates of nitride phases, the cooling rate should be higher than a critical value of about 0.95 °C/s. When this value is reached at any depth of the diffusion zone, two distinct diffusion zones will appear. Temperature gradients were measured inside the samples as a consequence of the plasma treatment. It's suggested the need for standardization of the term “treatment temperature” for plasma treatment because different nitrided layer properties could be reported for the same “treatment temperature”.
Resumo:
The detention and infiltration ponds of urban drainage system has function to protect the population from undesirable effects of floods. In general these ponds are not completly used and it potential is wasted. As it are disseminated at different places at cities it can reduce costs with water transport and permit water preservation of best quality. Some it utilities includes use in green areas irrigation, industrial among than cooling towers and boiler, soil compaction, cleaning urban road, pisciculture and fire fighting system. The quality these water is influenced by anauthorized sewage in the drainage system. This study was performed in six detention and infiltration ponds at drainage system of Natal, which aim was to verify the non-portable use these ponds on urban environment. As indirect aim would to incentive the water utilization these ponds as a water source to another uses in urban environment. These ponds represents the characteristics of detention and infiltration of Natal city and consequently of Brazil. As the water quality, the ponds presents following characteristics: three has apparently good quality, other showed intermediate condition and two had water polluted. Were performed twenty sample in each ponds and the following parameters assessed: pH, temperature, dissolved oxygen, turbidity, electrical conductivity, coliform thermotolerant, ammonia, organic nitrogen, TKN, nitrate, total phosphorus and alkalinity, bicarbonate, chloride, total hardness, calcium and magnesium hardness, total solids, TSS, TDS, COD and SAR°. To utilization on pisciculture we recommend use in ponds which presents the best quality. Only one pond presented higher pollutants and it not being appropriated for use in cooling tower. The content of solids suspension restricted the water use in all ponds in boilers. As water use in soil compaction, cleaning urban road and fire fighting system the water from these ponds are not appropriated. However, the recommended limits from literature are to domestic sewage, due to this, the parameters are restrictive to diminish the sanitary risk that could be offered with it utilization. The infiltration velocity of water these assessed ponds restrict a moderato use, however the effects are potentiated only in soil less sandy, which not occur in Natal. It is recommend the unrestricted irrigation utilization in ponds with best quality of water, and a restricted irrigation to ponds with worst quality of water. As load of pollutants, it is recommended a complementary treatment in those ponds whit higher load to diminish sanitary risks. In only one pond was found one helminth eggs and due to the convention formula of results, it was found for all ponds less than 1 helminth/liter eggs.
Resumo:
In this work, AISI 1010 steel samples were plasma nitrided into 20% N 2 100 Pa and 400 Pa for N 2 and H 2 , respectively), temperatures of 500 and 580 °C, during 2 h. Three different procedures for cooling were accomplished after nitriding. In the first procedure the cooling occurred naturally, that is, the sample was kept on substrate holder. In the second one the sample was pulled off and cooling in a cold surface. Finally, in the third cooling process the sample was pulled off the substrate holder down into special reservoir filled with oil held at ambient temperature. The properties of the AISI 1010 steel samples were characterized by optical and electron microscopy, X-ray diffraction, Mössbauer spectroscopy and microhardness tests. Thermal gradient inside the sample kept on substrate holder during cooling process was measured by three inserted thermocouples at different depths. When samples were cooled rapidly the transformation of ϵ-Fe 2 − 3 N to γ′-Fe 4 N was inhibited. Such effect is indicated by the high concentration of ϵ-Fe compound zone. To get solid state solution of nitrogen in the diffusion zone, instead of precipitates of nitride phases, the cooling rate should be higher than a critical value of about 0.95 °C/s. When this value is reached at any depth of the diffusion zone, two distinct diffusion zones will appear. Temperature gradients were measured inside the samples as a consequence of the plasma treatment. It's suggested the need for standardization of the term “treatment temperature” for plasma treatment because different nitrided layer properties could be reported for the same “treatment temperature”.