337 resultados para Conforto luminoso

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study addresses the environmental quality in therapeutic spaces for children's rehabilitation. The assumption that space is active and interfere in interpersonal relationships, highlights the importance of natural light to the hospital architecture, to foster the creation of environments that encourage and assist in the recovery of patients in the rehabilitation process. Therefore, interferes with health humanization through positive actions in the physiological and emotional effects of natural light, as facilitators of the health recovery process. In Brazil hospital openings systems projects are built exclusively to follow requirements of the local construction code which do not consider the landscape, but only ventilation and heat stroke; and the luminance levels are treated just as recommendations for artificial lighting. The National Policy for Healthcare Humanization presents the environmental comfort as a priority. However, it does not guidelines for achieving it. In this context this research aims to evaluate the lighting comfort in infant therapeutic areas from the professional satisfaction, in order to identify human preferences on the variables: technical and constructive aspects, relationship with the exterior, internal visual interface and quality elements. With this purpose it was adopted as research strategy the Post-Occupancy Evaluation (Technical Functional) through a multi method approach, which included a case study in the rehabilitation gym of Children Rehabilitation Center, at Natal, Rio Grande do Norte, and a reference study at SARAH Rehabilitation Center, Fortaleza Unit at Ceará, both in Brazil northeast. The results indicate that the definition of openings systems should consider external and internal factors to the building, as the natural landscape, the immediate surroundings and activities to be performed. The POE found out the preference of the professional visual privacy in detriment to other analyzed aspects. Thus, it is expected that this study can contribute to the discussion of luminous quality and generate inputs for future projects or renovations in the Children's Rehabilitation Centers, which should not be projected as hospitals

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Este trabalho visa analisar o potencial do sombreamento vegetal no edifício para promover conforto térmico, luminoso e eficiência energética, a partir de simulações computacionais nos softwares DesignBuilder e Daysim. Foram simuladas diferentes combinações de fator de céu visível (FCV), transparência da copa vegetal e percentual de abertura da fachada (PAF) para edificação residencial térrea em Nata/RN, a fim de quantificar os impactos e propor recomendações projetuais. Os modelos foram analisados por meio do método de conforto adaptativo indicado pela ASHRAE Standard 55 (ASHRAE, 2010), classificação do nível de eficiência energética do Regulamento Técnico da Qualidade para o Nível de Eficiência Energética de Edificações Residenciais (RTQ-R), resultados de Daylight autonomy (DA) e uniformidade da luz natural para as exigências lumínicas de 100-300-500 lux. Os resultados demonstram grande potencial para integração da vegetação na edificação, principalmente para os fatores de céu médio e grande, e falta de coerência do RTQ-R para classificar as edificações da Zona bioclimática 08 pelo método de simulação.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Este trabalho visa analisar o potencial do sombreamento vegetal no edifício para promover conforto térmico, luminoso e eficiência energética, a partir de simulações computacionais nos softwares DesignBuilder e Daysim. Foram simuladas diferentes combinações de fator de céu visível (FCV), transparência da copa vegetal e percentual de abertura da fachada (PAF) para edificação residencial térrea em Nata/RN, a fim de quantificar os impactos e propor recomendações projetuais. Os modelos foram analisados por meio do método de conforto adaptativo indicado pela ASHRAE Standard 55 (ASHRAE, 2010), classificação do nível de eficiência energética do Regulamento Técnico da Qualidade para o Nível de Eficiência Energética de Edificações Residenciais (RTQ-R), resultados de Daylight autonomy (DA) e uniformidade da luz natural para as exigências lumínicas de 100-300-500 lux. Os resultados demonstram grande potencial para integração da vegetação na edificação, principalmente para os fatores de céu médio e grande, e falta de coerência do RTQ-R para classificar as edificações da Zona bioclimática 08 pelo método de simulação.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This master thesis introduces assessment procedures of daylighting performance in office rooms with shaded opening, recommendations for Natal-RN (Latitude 05,47' S, Longitude 35,11' W). The studies assume the need of window exterior shading in hot and humid climate buildings. The daylighting performance analyses are based on simulated results for three levels of illuminance (300,500 e 1000 lux) between 08h00 e 16h00, in rooms with 2,80 m height, 6 m large and 4 m, 6 m e 8 m depths, with a centered single opening, window wall ratio (20%, 40% e 60%), four orientations (North, East, South and West), and two types of sky (clear and partially cloudy). The sky characteristics were statistically determined based on hourly data from INPE-CRN solar and daylighting weather station. The lighting performance is resulted from dynamic computer simulation of 72 models using Troplux 3.12. The simulation results were assessed using a new parameter to quantify the use of interior daylighting, the useful percentage of daylight (PULN), which corresponds to the time fraction with satisfactory light, in accordance with the illuminance design. The passive zone depths are defined based on the PULN. Despite the failures of illuminance data from the weather station, the analyses ratified the high potential of daylighting for shaded rooms. The most influential variables on the lighting performance are the opening size and the illuminance of design, while the orientation is a little influential

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This master thesis introduces assessment procedures of daylighting performance in office rooms with shaded opening, recommendations for Natal-RN (Latitude 05,47' S, Longitude 35,11' W). The studies assume the need of window exterior shading in hot and humid climate buildings. The daylighting performance analyses are based on simulated results for three levels of illuminance (300,500 e 1000 lux) between 08h00 e 16h00, in rooms with 2,80 m height, 6 m large and 4 m, 6 m e 8 m depths, with a centered single opening, window wall ratio (20%, 40% e 60%), four orientations (North, East, South and West), and two types of sky (clear and partially cloudy). The sky characteristics were statistically determined based on hourly data from INPE-CRN solar and daylighting weather station. The lighting performance is resulted from dynamic computer simulation of 72 models using Troplux 3.12. The simulation results were assessed using a new parameter to quantify the use of interior daylighting, the useful percentage of daylight (PULN), which corresponds to the time fraction with satisfactory light, in accordance with the illuminance design. The passive zone depths are defined based on the PULN. Despite the failures of illuminance data from the weather station, the analyses ratified the high potential of daylighting for shaded rooms. The most influential variables on the lighting performance are the opening size and the illuminance of design, while the orientation is a little influential

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present research concerns about outdoor s thermal comfort conditions in hot-humid climate cities, understanding that life quality is a result of the urban object s type built for the human being in an environment with specific climate and morphological characteristics. It is presented as object of study the correlation between the neighborhood Renascença II s microclimate in São Luis /MA-Brazil, hot-humid climate city, and its urban morphological changes. As well as the thermal comfort s satisfaction level of its outdoor users. The research has as general goal to diagnosis the way these transformations caused by the urbanization influence the Renascença II s microclimate, identifying critical spots of the studied area, in order to contribute with land use recommendations based on bioclimatic architecture concepts and supply bases to urban design decisions adequate to the São Luis climate. It is presented as theoretical bases the urban climate, its concepts and elements. After that, the thermal comfort conditioners and its prediction models of thermal comfort sensation in outdoor are presented. The predictive models are presented along with bioclimatic assessment methods. Finally the use of bioclimatic assessment as an effective tool to identify places that need changes or preservation in order to seek environment quality. The applied methodology was based on the studies of Katzschner (1997), complemented by Oliveira s (1988) and Bustos Romero s (2001) studies that suggest an analysis and evaluation of maps of topography, buildings floors, land use, green areas and land covering, in order to overlap their characteristics and identify climate variable s measurements points; then a quantitative analysis of the climate variables (air temperature and humidity, wind speed and direction) of the chosen points takes place. It was perceived that Renaissance II has no permanence areas as squares or parks, its outdoor has little vegetation and presets high land impermeability and built density levels. The majority of the people interviewed said that was comfortable in a range of air temperature between 27,28ºC and 30,71ºC. The elaboration of a neighborhood master plan is important, which defines strategies for improvement of the life quality of its inhabitants

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The assessment of building thermal performance is often carried out using HVAC energy consumption data, when available, or thermal comfort variables measurements, for free-running buildings. Both types of data can be determined by monitoring or computer simulation. The assessment based on thermal comfort variables is the most complex because it depends on the determination of the thermal comfort zone. For these reasons, this master thesis explores methods of building thermal performance assessment using variables of thermal comfort simulated by DesignBuilder software. The main objective is to contribute to the development of methods to support architectural decisions during the design process, and energy and sustainable rating systems. The research method consists on selecting thermal comfort methods, modeling them in electronic sheets with output charts developed to optimize the analyses, which are used to assess the simulation results of low cost house configurations. The house models consist in a base case, which are already built, and changes in thermal transmittance, absorptance, and shading. The simulation results are assessed using each thermal comfort method, to identify the sensitivity of them. The final results show the limitations of the methods, the importance of a method that considers thermal radiance and wind speed, and the contribution of the chart proposed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research covers the topic of social housing and its relation to thermal comfort, so applied to an architectural and urban intervention in land situated in central urban area of Macaíba/RN, Brazil. Reflecting on the role of design and use of alternative building materials in the search for better performance is one of its main goals. The hypothesis is that by changing design parameters and choice of materials, it is possible to achieve better thermal performance results. Thus, we performed computer simulations of thermal performance and natural ventilation using computational fluid dynamics or CFD (Computational Fluid Dynamics). The presentation of the thermal simulation followed the methodology proposed in the dissertation Negreiros (2010), which aims to find the percentage of the amount of hours of comfort obtained throughout the year, while data analysis was made of natural ventilation from images generated by the images extracted from the CFD. From model building designed, was fitted an analytical framework that results in a comparison between three different proposals for dwellings housing model, which is evaluated the question of the thermal performance of buildings, and also deals with the spatial variables design, construction materials and costs. It is concluded that the final report confirmed the general hypotheses set at the start of the study, it was possible to quantify the results and identify the importance of design and construction materials are equivalent, and that, if combined, lead to gains in thermal performance potential.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The recent tendency to utilize parking lots for other purposes has demonstrated that more time has been spent by visitors, mainly in great cities. Therefore, this paper investigates the thermal comfort and the air quality indoors in areas specifically used as parking lots by analyzing the direct relation between such environments and vehicular pollution. The thermal comfort and the quality of air indoors in parking lots with different architectonic typology (ground-floor and underground) are also studied, aiming to contribute to the proposition of suitable new areas designated to human usage. Field research was done, in two distinct periods within different weather conditions (January and July) in, two naturally cooled, parking lots located in Natal - RN. The internal environment agents were measured by using tools for air temperature, humidity, speed and direction; interviews with employees and visitors and chemical analysis through appropriate tools to analyze specific material, carbon monoxide and ozone. The results showed that chemical agents densely concentrate mostly in the closed parking space, aggravated by weather conditions, which dissatisfied the visitors. Still, it was shown that architectonic typology, alongside topographical aspects compromise internal environmental conditions, which increases the retention of pollution, leading to dissatisfactory thermal comfort levels and becoming less suitable for usage by visitors considering air and thermal comfort aspects. Consequently, they are not suitable for human stay due to the poor quality of the indoor air

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research aimed to identify the link between the layout of workspaces in offices and the design strategies for environmental comfort. Strategies surveyed were focused on the thermal, visual and luminic comfort. In this research, visual comfort is related to issues of visual integration within and between the interior and exterior of the building. This is a case study conducted at the administrative headquarters of Centro Regional Nordeste do Instituto de Pesquisas Espaciais (INPE-CRN), located in Natal/RN. The methodological strategy used was the Post-Occupancy Evaluation, which combined the survey data on the building (layout of workspaces, bioclimatic strategies adopted in the design, use of these strategies) with some techniques aimed at acquiring qualitative information related to users. The workspace layout is primordial to satisfaction and productivity of workers. Issues such as concentration, communication, privacy, personal identity, density and space efficiency, barriers (access, visual and even ventilation and lighting), among others, are associated with the layout. The environmental comfort is one of the essential elements to maintaining life quality in workplace. Moreover, it is an important factor in user`s perception of the space in which he or she are inserted. Both layout and environmental comfort issues should be collected and analyzed in the establishment phase of the programming step. That way, it is possible to get adequate answers to these questions in subsequent project phases. It was found that changes in the program that occurred over time, especially concerning persons (number and characteristics), resulted in changes in layout, generating high density and inflexible environments. It turns difficult to adjust the furniture to the occupants` requirement, including comfort needs. However, the presence of strategies for environmental quality provides comfort to spaces, ensuring that, even in situations not considered optimal, users perceive the environment in a positive way. It was found that the relationship between environmental comfort and layout takes the following forms: in changing the perception of comfort, depending on the layout of the arrangements; adjustments in layout, due to needs for comfort; and the elevation of user satisfaction and environmental quality due to the presence of strategies comfort even in situations of inadequate layout

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was intended to investigate how the urban form has been influencing the changes in the climate of the city and make a correlation between the climate and the thermal sensation of the users of open spaces. The research was developed in the district of Petrópolis in Natal/ RN whose occupation has been almost consolidated. Among other reasons, this district was selected because it was planned considering the environmental aspects of comfort. The methodologies used are based on KATZSCHNER (1997) and OLIVEIRA (1988) studies, which suggest the drawing and analysis of maps of the area under study, including topography, height of the buildings, land use, green areas, and types of soil pavement, as well as measurement of the environmental variables: air temperature, relative humidity, direction and wind speed for a comparative study. As part of this, study local users of the district were interviewed about their thermal sensations in open spaces. For the statistical analysis, data was collected at 10 distinct points characterized by BUSTOS ROMERO (2002), being 8 within the district and 2 at different places (outside the district), at climatologic stations, in 3 periods (August/2000, January/2002 and June/2002), for 4 consecutive days for each measurement (from Sunday to Wednesday) at the time of lower and higher temperatures in the city, 6:00 am and 1:00 pm, respectively. At the same time interviews were carried out with users of the open spaces in the area, totaling 171 valid formularies. The urban form showed a rather leveled topography, great diversity of land use and height of the buildings, with the existence of an area mostly occupied with high buildings, very little green area and soil practically impermeable. The statistical analysis showed high temperature and humidity levels. The wind direction is predominantly Southeast with extremely variable speeds. When the data from this district is compared with the data from other areas in the city and its outskirt, it was observed that this district is hotter and less ventilated than the others; besides, most users said that they felt uncomfortable in the local environmental conditions. The results of the analysis generated a zoning for the district with recommendations for soil occupation. The profile of the user was defined regarding the thermal comfort, as well as some discussion about the comfort parameters, including the proposal of limiting areas of temperature and humidity for the thermal comfort in the open spaces

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years, the Universidade Federal do Rio Grande do Norte (UFRN) has come through an intense process of expansion, common for the Instituições Federais de Ensino Superior (IFES) - Higher Education Institutions – since the implantation of the Programa de Reestruturação e Expansão das Universidades Federais (REUNI), a program of restructuring and expansion of the federal universities. The incentives made at UFRN can be seen into the expansion of the fields of teaching, research and extension, besides hiring human resources and adaptation / expansion of physical spaces. The focus of the UFRN at the technological area through the project (REUNI) has reflected in a significant expansion of the physical structure of the Center of Technology, area where the section of classes IV remains being the main set of rooms that supports the demand of the courses in the technological area, in which highlights the lack of classrooms. In this sense, the work presented here, proposes an architectural blueprint for expanding the physical space of this sector, based in this main parameters: (i) the spatial flexibility that attends the varying numbers of students per class; (ii) the environmental comfort, using the parameters and guidelines constructive for the Bioclimatic Zone 8; (iii) the requirements contained in the rules of ABNT NBR 9050:2004, 9077:2001 and NBR NBR 15220-3:2003. The architectural proposal used the maximum template allowed by the UFRN Central Campus Master Plan, four floors, considering the existing building (area equal to 7413.95 m²) as the ground floor and the extension proposed distributed on three floors, with an area of around 2,535, 00 m² each, making up a total of 7602.65 m² of total area built

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivou-se identificar o cuidado realizado pelo enfermeiro para o conforto de pacientes idosos em pós-operatório. Especificamente objetivou-se: 1) Identificar a perspectiva dos enfermeiros sobre os desconfortos nos contextos físico, psicoespiritual, ambiental e sociocultural evidenciados em idosos no pós-operatório; 2) Verificar as características definidoras e os fatores relacionados inseridos ao diagnóstico de enfermagem conforto prejudicado, identificados pelos enfermeiros no idoso em pós-operatório; 3) Identificar as intervenções de enfermagem para promoção do conforto ao idoso em pós-operatório realizadas pelos enfermeiros no seu cuidar. Trata-se de uma pesquisa exploratória, descritiva, de abordagem quantitativa, desenvolvida em um hospital universitário do Município de Natal/RN, Brasil. A população foi constituída pelos 30 enfermeiros que trabalhavam em unidades de internação cirúrgica e terapia intensiva e que prestavam atendimento à pacientes idosos em pós-operatório. Consideraram-se critérios de inclusão: ter tempo mínimo de seis meses de atividade no setor e fazer parte da escala de serviço no período da coleta dos dados. Como critérios de exclusão: estar de licença ou férias no momento da coleta de dados. Toda população formou o grupo de sujeitos do estudo. A coleta de dados foi concretizada em maio e junho de 2014 utilizando um questionário autoexplicativo, composto por quatro partes: I - Caracterização dos enfermeiros; II - Necessidades de conforto do idoso no pós-operatório; III - Diagnóstico de Enfermagem; IV - Intervenções de enfermagem. O projeto foi aprovado pelo Comitê de Ética em Pesquisa (CEP) da Universidade Federal do Rio Grande do Norte, sob CAAE25976613.7.0000.5537. Os dados foram tabulados no Statistical Package for the Social Sciences (SPSS) 20.0 e apresentados utilizando-se frequências, percentuais e medidas de tendência central. Os resultados mostram que 96,7% dos enfermeiros conceituaram conforto como sinônimo de bem-estar. Houve maior frequência do desconforto dor (100%), ruídos excessivos (56,7%), sensação de deslocamento do ambiente residencial (76,7%) e ansiedade (93,3%). Os enfermeiros evidenciaram como sinais e sintomas que caracterizam o desconforto do idoso após cirurgia, principalmente: dor (75,9%), inquietação (58,6%), sinais vitais (41,4%) e ansiedade (34,5%). O principal fator relacionado foi o efeito secundário relacionado ao tratamento (88%). As principais intervenções realizadas foram: ouvir atentamente (100%) e controle da dor (100%). Estas foram igualmente analisadas como prioritárias para esta ação de cuidado, na porcentagem de 76,7% e 66,7%, respectivamente. Conclui-se que os enfermeiros identificam os desconfortos que afetam os idosos no pós-operatório na diversidade dos contextos estudados, com uma ênfase maior aos desconfortos físicos e em especial, a dor. Além disso, possuem uma percepção ampliada sobre os possíveis sinais e sintomas apresentados pelos idosos em pós-operatório quando estão desconfortáveis, uma vez que evidenciam outras 12 características não previstas no Diagnóstico de Enfermagem Conforto prejudicado e também identificam os fatores relacionados a estes desconfortos. Entretanto, apesar de afirmarem que realizam intervenções para amenizá-los e as registrarem, estes dados não podem ser afirmados que se trata de um padrão da prática destes profissionais, uma vez que não foi realizado a observação do cuidado prestado a esta clientela nem avaliação dos prontuários.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The city of Natal has a significant daylight availability, although it use isn’t systematically explored in schools architecture. In this context, this research aims to determine procedures for the analysis of the daylight performance in school design in Natal-RN. The method of analysis is divided in Visible Sky Factor (VSF), simulating and analyzing the results. The annual variation of the daylight behavior requires the adoption of dynamic simulation as data procedure. The classrooms were modelled in SketchUp, simulated in Daysim program and the results were assessed by means of spreadsheets in Microsoft Excel. The classrooms dimensions are 7.20mx 7.20m, with windows-to-wall-ratio (WWR) of 20%, 40% and 50%, and with different shading devices, such as standard horizontal overhang, sloped overhang, standard horizontal overhang with side view protection, standard horizontal overhang with a dropped edge, standard horizontal overhang with three horizontal louvers, double standard horizontal overhang, double standard horizontal overhang with three horizontal louvers, plus the use of shelf light in half the models with WWR of 40% and 50%. The data was organized in spreadsheets, with two intervals of UDI: between 300lux and 2000 lux and between 300lux and 3000lux. The simulation was performed with the weather file of 2009 to the city of NatalRN. The graphical outputs are illuminance curves, isolines of UDI among 300lux and 2000 lux and tables with index of occurrences of glare and to an UDI among 300lux 3000lux. The best UDI300-2000lux performance was evidenced to: Phase 1 (models with WWR of 20%), Phase 2 (models with WWR of 40% and 50% with light shelf). The best UDI300-3000lux performance was evidenced to: Phase 1 (models with WWR of 20% and 40% with light shelf) and Phase 2 (models with WWR of 40% and 50% with light shelf). The outputs prove that the daylight quality mainly depends on the shading system efficacy to avoid the glare occurrence, which determines the daylight discomfort. The bioclimatic recommendations of big openings with partial shading (with an opening with direct sunlight) resulted in illuminances level higher than the acceptable upper threshold. The improvement of the shading system percentage (from 73% to 91%) in medium-size of openings (WWR 40% and 50%) reduced or eliminate the glare occurrence without compromising the daylight zone depth (7.20m). The passive zone was determined for classrooms with satisfactory daylight performance, it was calculated the daylight zone depth rule-of-thumb with the ratio between daylight zone depth and the height of the window for different size of openings. The ratio ranged from 1.54 to 2.57 for WWR of 20%, 40% and 50% respectively. There was a reduction or elimination of glare in the passive area with light shelf, or with awning window shading.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this research is to analyze different daylighting systems in schools in the city of Natal/RN. Although with the abundantly daylight available locally, there are a scarce and diffuse architectural recommendations relating sky conditions, dimensions of daylight systems, shading, fraction of sky visibility, required illuminance, glare, period of occupation and depth of the lit area. This research explores different selected apertures systems to explore the potential of natural light for each system. The method has divided into three phases: The first phase is the modeling which involves the construction of three-dimensional model of a classroom in Sketchup software 2014, which is featured in follow recommendations presented in the literature to obtain a good quality of environmental comfort in school settings. The second phase is the dynamic performance computer simulation of the light through the Daysim software. The input data are the climate file of 2009 the city of Natal / RN, the classroom volumetry in 3ds format with the assignment of optical properties of each surface, the sensor mapping file and the user load file . The results produced in the simulation are organized in a spreadsheet prepared by Carvalho (2014) to determine the occurrence of useful daylight illuminance (UDI) in the range of 300 to 3000lux and build graphics illuminance curves and contours of UDI to identify the uniformity of distribution light, the need of the minimum level of illuminance and the occurrence of glare.