5 resultados para Conceptualizing and Measuring

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The heat transfer between plasma and a solid occurs mostly due the radiation and the collision of the particles on the material surface, heating the material from the surface to the bulk. The thermal gradient inside the sample depends of the rate of particles collisions and thermal conductivity of the solid. In order to study that effect, samples of AISI M35 steel, with 9,5 mm X 3,0 mm (diameter X thickness) were quenched in resistive furnace and tempereds in plasma using the plane configuration and hollow cathode, working with pressures of 4 and 10 mbar respectively. Analyzing the samples microstructure and measuring the hardness along the transversal profile, it was possible to associate the tempered temperature evaluating indirectly the thermal profile. This relation was obtained by microstructural analyzes and through the hardness curve x tempered sample temperature in resistive furnace, using temperatures of 500, 550, 600, 650 and 700°C. The microstructural characterization of the samples was obtained by the scanning electron microscopy, optic microscopy and X-ray diffraction. It was verified that all samples treated in plasma presented a superficial layer, denominated affected shelling zone, wich was not present in the samples treated in resistive furnace. Moreover, the samples that presented larger thermal gradient were treated in hollow cathode with pressure of 4 mbar

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of this research is to discuss about the need for implementation of new alternatives for the implementation on the metrological control: on the findings of initial and subsequent measurements, the control procedures of measurement uncertainty applied in assessing the loss or remains found in handling operations of bulk liquids, when used turbine meters used in measuring the tax on the business of Petrobras, due to the current environment of legal metrology and scientific, both domestic and international. We aim, with these alternatives: standardizing the minimization of random and systematic errors, the estimate of the remaining errors, as well as the management control of metrological calibration procedures, control of measurement uncertainty, and contribute to the change in the form of performance of legal metrology and scientific disseminating new information to change management of metrological control, objectively focused on aspects of supervision in implementing these activities in the control of the uncertainties of measurement used in our processes in the fiscal measurement system Petrobras. Results are presented, information and comments on the influence of measurement uncertainty in the current results of the fiscal and transfer of custody. This will emphasize the need, among other things, improvement and expansion of metrological control monitored by setting a better meet demand, calibration equipment and measuring instruments for Petrobras. Finally, we intend to establish the need for improving the method of evaluation of the data meter applied to the current management control of measurement uncertainty by proposing a methodology for addressing the problem, as well as highlighting the expected results.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present study aims the characterization of thermally affected carbonate rocks from Jandaíra Formation in contact with Paleogene and Neogene basic intrusions in the region of the Pedro Avelino and Jandaíra municipalities (RN), northeastern Brazil. For this study, field, petrographic, x-ray diffraction, electron microprobe, and whole rock litogeochemistry data of carbonates were undertaken. The thermally unaffected limestones are classified like wackstones, grainstones and packstones. They may constitute carbonates grains of benthic foraminifera, echinoderm spines, ostracods, algae, corals, bivalves, gastropods, peloids and intraclasts. The porosities are classified like vug, intraparticle, interparticle, intercrystal and moldic types. The major minerals are calcite, ankerite and dolomite; the detrital are montmorillonite, pyrite, limonite, quartz and microcline. The thermally affected limestones are very coarse to very fine-grained and light to dark gray color. The fossiliferous components totally disappear, and the porosity tends to disappear. With the data obtained, it can be inferred that the carbonate protoliths would be calciferous to dolomitic limestones, both with small amount of clay minerals. Crystalline carbonates from dolomitic protolith have rhombohedral calcite and iron oxides / hydroxides, making the rocks much darker. The carbonates from calciferous protolith have a wide variation of grain size according to the recrystallization degree, increasing toward contact with the basic bodies. In this group, it was identified the minerals lizardite and spinel in weakly to moderately affected samples, and spinel and spurrite in strongly affected rocks, as well as calcite, that occur everywhere. The geological context (shallow level diabase intrusions), the crystallization of the pyrometamorphic minerals spurrite and olivine, and comparison with diagrams from the literature allow estimating temperatures and pressures around 1050-1200 °C and 0.5-1.0 kbar, respectively, for PTOTAL=PCO2. The post-intrusion cooling would have afforded the releasing of metasomatic / hydrothermal fluids, allowing the opening of the metamorphic system, with possible contribution of chemical elements from host units (sandstones, shales) and from basic intrusions. This would induce hydration of previous phases, allowing the formation of serpentine, chlorite and brucite. The results discussed here reveal the strong influence of the heat from basic intrusions within the sedimentary pile. Whereas in the offshore portion of the basin occur sills with up to 1000 m thickness, the understanding of pyrometamorphism might be useful for understanding and measuring the thermally affected rocks.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present study aims the characterization of thermally affected carbonate rocks from Jandaíra Formation in contact with Paleogene and Neogene basic intrusions in the region of the Pedro Avelino and Jandaíra municipalities (RN), northeastern Brazil. For this study, field, petrographic, x-ray diffraction, electron microprobe, and whole rock litogeochemistry data of carbonates were undertaken. The thermally unaffected limestones are classified like wackstones, grainstones and packstones. They may constitute carbonates grains of benthic foraminifera, echinoderm spines, ostracods, algae, corals, bivalves, gastropods, peloids and intraclasts. The porosities are classified like vug, intraparticle, interparticle, intercrystal and moldic types. The major minerals are calcite, ankerite and dolomite; the detrital are montmorillonite, pyrite, limonite, quartz and microcline. The thermally affected limestones are very coarse to very fine-grained and light to dark gray color. The fossiliferous components totally disappear, and the porosity tends to disappear. With the data obtained, it can be inferred that the carbonate protoliths would be calciferous to dolomitic limestones, both with small amount of clay minerals. Crystalline carbonates from dolomitic protolith have rhombohedral calcite and iron oxides / hydroxides, making the rocks much darker. The carbonates from calciferous protolith have a wide variation of grain size according to the recrystallization degree, increasing toward contact with the basic bodies. In this group, it was identified the minerals lizardite and spinel in weakly to moderately affected samples, and spinel and spurrite in strongly affected rocks, as well as calcite, that occur everywhere. The geological context (shallow level diabase intrusions), the crystallization of the pyrometamorphic minerals spurrite and olivine, and comparison with diagrams from the literature allow estimating temperatures and pressures around 1050-1200 °C and 0.5-1.0 kbar, respectively, for PTOTAL=PCO2. The post-intrusion cooling would have afforded the releasing of metasomatic / hydrothermal fluids, allowing the opening of the metamorphic system, with possible contribution of chemical elements from host units (sandstones, shales) and from basic intrusions. This would induce hydration of previous phases, allowing the formation of serpentine, chlorite and brucite. The results discussed here reveal the strong influence of the heat from basic intrusions within the sedimentary pile. Whereas in the offshore portion of the basin occur sills with up to 1000 m thickness, the understanding of pyrometamorphism might be useful for understanding and measuring the thermally affected rocks.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The heat transfer between plasma and a solid occurs mostly due the radiation and the collision of the particles on the material surface, heating the material from the surface to the bulk. The thermal gradient inside the sample depends of the rate of particles collisions and thermal conductivity of the solid. In order to study that effect, samples of AISI M35 steel, with 9,5 mm X 3,0 mm (diameter X thickness) were quenched in resistive furnace and tempereds in plasma using the plane configuration and hollow cathode, working with pressures of 4 and 10 mbar respectively. Analyzing the samples microstructure and measuring the hardness along the transversal profile, it was possible to associate the tempered temperature evaluating indirectly the thermal profile. This relation was obtained by microstructural analyzes and through the hardness curve x tempered sample temperature in resistive furnace, using temperatures of 500, 550, 600, 650 and 700°C. The microstructural characterization of the samples was obtained by the scanning electron microscopy, optic microscopy and X-ray diffraction. It was verified that all samples treated in plasma presented a superficial layer, denominated affected shelling zone, wich was not present in the samples treated in resistive furnace. Moreover, the samples that presented larger thermal gradient were treated in hollow cathode with pressure of 4 mbar