5 resultados para Computer aided design tool
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
The modern society depends on an efficient communications system able to of transmitting and receiving information with a higher speed and reliability every time. The need for ever more efficient devices raises optimization techniques of microstrip devices, such as techniques to increase bandwidth: thicker substrates and substrate structures with EBG (Electromagnetic Band Gap) and PBG (Photonic Band Gap). This work has how aims the study of the application of PBG materials on substrates of planar structures in microstrip, more precisely in directional quadrature couplers and in rat-race and impedance of transformers. A study of the planar structures in microstrip and substrates EBG is presented. The PBG substrates can be used to optimize the radiation through the air, thus reducing the occurrence of surface waves and the resulting diffraction edge responsible for degradation of radiation pattern. Through specific programs in FORTRAN Power Station obtained the frequencies and couplings for each structure. Are used the program PACMO - Computer Aided Design in Microwave. Results are obtained of the frequency and coupling devices, ranging the frequency band used (cellular communication and Wimax systems) and the permittivity of the substrate, comparing the results of conventional material and PBG materials in the s and p polarizations.
Resumo:
This work presents the research carried through in the industrial segment of confection of clothes of the Great Natal whose objective is to show the profile, enterprise and technological management as also the use of simultaneous engineering in the development of products. The research approaches two studies. The first one presents the current picture of the companies, synthesized through twelve variable. As, through fifteen variable it shows to the level of use of Simultaneous Engineering in the Development of Products and its amplitude in relation to the Integrated Management using tools CAD, PDM and ERP (Computer Aided Design, Product Management Date, Enterprise Resource Planning). The integration of these systems acts aiming the reduction of the cost and the development time of products. The reached results indicate that simultaneous engineering is a competitive advantage and becomes possible: to reduce the life cycle of the product, to rationalize the resources, to incorporate one high standard of the quality to the process and product as well as to personalize the product to take care of the global market. It is important to note that this work also is considered to contribute for the better understanding of the real companies situation of confection located at the Great Natal and its role in the economy of the State of the Rio Grande do Norte
Resumo:
The fractal self-similarity property is studied to develop frequency selective surfaces (FSS) with several rejection bands. Particularly, Gosper fractal curves are used to define the shapes of the FSS elements. Due to the difficulty of making the FSS element details, the analysis is developed for elements with up to three fractal levels. The simulation was carried out using Ansoft Designer software. For results validation, several FSS prototypes with fractal elements were fabricated. In the fabrication process, fractals elements were designed using computer aided design (CAD) tools. The prototypes were measured using a network analyzer (N3250A model, Agilent Technologies). Matlab software was used to generate compare measured and simulated results. The use of fractal elements in the FSS structures showed that the use of high fractal levels can reduce the size of the elements, at the same time as decreases the bandwidth. We also investigated the effect produced by cascading FSS structures. The considered cascaded structures are composed of two FSSs separated by a dielectric layer, which distance is varied to determine the effect produced on the bandwidth of the coupled geometry. Particularly, two FSS structures were coupled through dielectric layers of air and fiberglass. For comparison of results, we designed, fabricated and measured several prototypes of FSS on isolated and coupled structures. Agreement was observed between simulated and measured results. It was also observed that the use of cascaded FSS structures increases the FSSs bandwidths and, in particular cases, the number of resonant frequencies, in the considered frequency range. In future works, we will investigate the effects of using different types of fractal elements, in isolated, multilayer and coupled FSS structures for applications on planar filters, high-gain microstrip antennas and microwave absorbers
Resumo:
The great interest observed in wireless communication systems has required the development of new configurations of microstrip antennas, because they are easily built and integrated to other microwave circuit components, which is suitable for the construction and development of planar antenna arrays and microwave integrated circuits. This work presents a new configuration of tapered microstrip antenna, which is obtained by impressing U-slots on the conducting patch combined with a transmission line matching circuit that uses an inset length. It is shown that the use of U-slots in the microstrip antenna conducting patch excites new resonating modes, that gives a multiband characteristic for the slotted microstrip antenna, that is suitable for applications in communication systems that operates several frequencies simultaneously. Up to this date, the works reported in the literature deals with the use of Uslotted microstrip rectangular antennas fed by a coaxial probe. The properties of a linear array of microstrip patch tapered antennas are also investigated. The main parameters of the U slotted tapered microstrip antennas are investigated for different sizes and locations of the slots impressed on the conducting patch. The analysis of the proposed antenna is performed by using the resonant cavity and equivalent transmission line methods, in combination with a parametric study, that is conducted by the use of the Ansoft Designer, a commercial computer aided microwave software well known by its accuracy and efficiency. The mentioned methods are used to evaluate the effect in the antennas parameters, like resonant frequency and return loss, produced by variations of the antenna structural parameters, accomplished separately or simultaneously. An experimental investigation is also developed, that consists of the design, construction and measurement of several U slotted microstrip antenna prototypes. Finally, theoretical and simulated results are presented that are in agreement with the measured ones. These results are related to the resonating modes identification and to the determination of the main characteristics of the investigated antennas, such as resonant frequency, return loss, and radiation pattern
Resumo:
Lung cancer is one of the most common types of cancer and has the highest mortality rate. Patient survival is highly correlated with early detection. Computed Tomography technology services the early detection of lung cancer tremendously by offering aminimally invasive medical diagnostic tool. However, the large amount of data per examination makes the interpretation difficult. This leads to omission of nodules by human radiologist. This thesis presents a development of a computer-aided diagnosis system (CADe) tool for the detection of lung nodules in Computed Tomography study. The system, called LCD-OpenPACS (Lung Cancer Detection - OpenPACS) should be integrated into the OpenPACS system and have all the requirements for use in the workflow of health facilities belonging to the SUS (Brazilian health system). The LCD-OpenPACS made use of image processing techniques (Region Growing and Watershed), feature extraction (Histogram of Gradient Oriented), dimensionality reduction (Principal Component Analysis) and classifier (Support Vector Machine). System was tested on 220 cases, totaling 296 pulmonary nodules, with sensitivity of 94.4% and 7.04 false positives per case. The total time for processing was approximately 10 minutes per case. The system has detected pulmonary nodules (solitary, juxtavascular, ground-glass opacity and juxtapleural) between 3 mm and 30 mm.