5 resultados para Commercial buildings

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This research consists in studying the influence of the various type of construction systems of roofs with their energy efficiency as well as on the cost benefit for the commercial buildings on the temperatures condition of the city of Natal/RN. The main goal of this research is to analyze the cost benefit of the construction systems of roofs available on the market, taking into consideration the energy efficiency of the commercial buildings artificially air conditioned in order to be used by the projectors and to be adequated to the temperatures condition of the city of Natal/RN. The method of valuation of the cost benefit of roof systems consists in six steps: Features and simulation of the reference building; Analyze of sensitivity; Analyzes, features and simulation of alternatives of roof construction systems; Analyze of the cost of implementation; Analyze of the benefits of the alternatives comparing to the base case; And finally the analyze of the cost benefit. The model type chosen as reference was stores with pre molded buildings and system of roof with fiber ciment and ceiling . The thermal results showed the influence of the roof system on the energy efficiency of the building. The Final results of the simulations of the alternatives comes to a conclusion that the absortance is the variable that presents the best cost benefit relation and the reduction on the thermal transmittance still has limitations because of the high cost

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The main purpose of this study is to present complementary information on eolian systems that occur in the Center-South portion of the city of Natal, Rio Grande do Norte State, Brazil. The investigation focused on the identification of eolian units, absolute luminescence dating of eolian sediments, to geophysical analysis by Ground Penetrating Radar (GPR), as well as qualitative identification of the use and terrain occupation in the study area. A map was elaborated in order to separate eolian geological units, and describe their deposicional and erosional characteristics, by aerial photo-interpretation. The study lead to the identification of six main units: Unit I - Blowouts (BW), Unit II - Active dunes field (DA), Unit III - Fixed dunes field (DF), Unit IV - Parabolic dunes field (DP), Unit V - Red parabolic dunes field (DV) and Unit VI - Devastated dunes surface (SD). Were analised by Termoluminescense (TL) Method Eight samples from units I, III, IV and V. The largest number of samples with similar or close resulted yielded ages about 15,000 years. Two GPR profiles were obtained in areas of the Dunes Park, near the "Natal s Conventions Center". Results showed the migration a new dune generation over on older one, the geologic contact between dunes and the Formação Barreiras (FB), and the groundwater level inside the dune unit. The qualitative study on the use and terrain occupation of the soil in some dunes fields in the study area, it was possible identify some use and occupation, as the following ones: the construction of residential and commercial buildings, dunes fields cutted for construction to access road and garbage deposition

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The uncontrolled growth of most Brazilian cities is not accompanied by the development of urban infrastructure. With increasing soil sealing, runoff and decreased infiltration volume, impacts on water resources and on population of the areas affected by urban growth are inevitable. This study aims to evaluate the use and occupation of a watershed and analyze the drainage system in order to control the impact using tools to integrate urban development with the drainage of rainwater in an important watershed in the Natal City, Rio Grande do Norte State. The study involved the characterization of the basin XII.4 on the land use and occupation, for the years 2005 and 2014. With the application of SWMM model was possible to analyze the impacts caused by the urbanization process in the existing drainage system, showing the two years analyzed have their areas very close to percentage saturation of impervious areas. Although the region is still predominantly single family residential, suffers increasing verticalization of mainly commercial buildings. The drainage system is inefficient for the area's needs by the year 2005. The drainage system was also tested for four variations of land use by developing scenarios. Scenario 1 is related to the year 2014, considered current. Scenario 2 was adopted the maximum rate of 80% for land use, allowed for the Natal City. Scenario 3 gives the critical condition of land use, with the area 100% impervious. Scenario 4 is applied to the existence of LID (Low Impact Device). The scenarios analysis showed that all indicate deficiency at some point of the drainage system as a result of the high degree of occupation of the area that generate higher flows than the initial drainage system capacity. With the study it became clear that the adoption of non-structural tools are effective in reducing flooding and improving the drainage system capacity.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The uncontrolled growth of most Brazilian cities is not accompanied by the development of urban infrastructure. With increasing soil sealing, runoff and decreased infiltration volume, impacts on water resources and on population of the areas affected by urban growth are inevitable. This study aims to evaluate the use and occupation of a watershed and analyze the drainage system in order to control the impact using tools to integrate urban development with the drainage of rainwater in an important watershed in the Natal City, Rio Grande do Norte State. The study involved the characterization of the basin XII.4 on the land use and occupation, for the years 2005 and 2014. With the application of SWMM model was possible to analyze the impacts caused by the urbanization process in the existing drainage system, showing the two years analyzed have their areas very close to percentage saturation of impervious areas. Although the region is still predominantly single family residential, suffers increasing verticalization of mainly commercial buildings. The drainage system is inefficient for the area's needs by the year 2005. The drainage system was also tested for four variations of land use by developing scenarios. Scenario 1 is related to the year 2014, considered current. Scenario 2 was adopted the maximum rate of 80% for land use, allowed for the Natal City. Scenario 3 gives the critical condition of land use, with the area 100% impervious. Scenario 4 is applied to the existence of LID (Low Impact Device). The scenarios analysis showed that all indicate deficiency at some point of the drainage system as a result of the high degree of occupation of the area that generate higher flows than the initial drainage system capacity. With the study it became clear that the adoption of non-structural tools are effective in reducing flooding and improving the drainage system capacity.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This research consists in studying the influence of the various type of construction systems of roofs with their energy efficiency as well as on the cost benefit for the commercial buildings on the temperatures condition of the city of Natal/RN. The main goal of this research is to analyze the cost benefit of the construction systems of roofs available on the market, taking into consideration the energy efficiency of the commercial buildings artificially air conditioned in order to be used by the projectors and to be adequated to the temperatures condition of the city of Natal/RN. The method of valuation of the cost benefit of roof systems consists in six steps: Features and simulation of the reference building; Analyze of sensitivity; Analyzes, features and simulation of alternatives of roof construction systems; Analyze of the cost of implementation; Analyze of the benefits of the alternatives comparing to the base case; And finally the analyze of the cost benefit. The model type chosen as reference was stores with pre molded buildings and system of roof with fiber ciment and ceiling . The thermal results showed the influence of the roof system on the energy efficiency of the building. The Final results of the simulations of the alternatives comes to a conclusion that the absortance is the variable that presents the best cost benefit relation and the reduction on the thermal transmittance still has limitations because of the high cost