17 resultados para Coliforms

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The National School Nutrition Program is the oldest program in the country directed at food and nutrition safety. Its aims are to offer nutritional food as a supplement to students of public and philanthropic schools. Studying school nutrition transcends the investigation as a purely social program, given that it reaches the fields of public health, nutrition and food, using a wide variety of approaches. Thus, it is characterized by a multidisciplinary study, where the disciplines work side by side in distinct aspects of a single problem. Aim: This study aims to assess hygiene practices during the preparation of meat-based meals in public schools in the city of Natal, Brazil. Methods: A list was applied at 27 schools to identify the procedures of good food preparation practices. In addition, cooking and meal distribution temperature were measured and a microbiological analysis of the final preparation and of the water used in preparing it was performed. For microbiological analyses of the food, we analyzed coliforms at 45°C, coliforms at 35°C and Enterococcus, and for the water, we analyzed thermotolerant coliforms and total coliforms, using the methods recommended by APHA, 1995. Results: Most of the schools did not meet the required standards in all the variables related to good food preparation practices, except for the time spent preparing the meat, in which 89% were within the norm. Cooking temperature of the meals was within the standard; however, the temperature at distribution and the time spent dispensing the meals were inadequate. Of the 27 schools, 22 (81.5%) showed the presence of coliforms at 35° C in at least one meal sample and 18 (66.7%) had values above the recommended limit for coliforms at 45°C. The presence of E. coli was identified in 6.1% of the samples analyzed. The presence of Enterococcus was not found at any of the schools. With respect to the water, the North district of the city was the only one that did not meet the standards for the two indicators evaluated. The contamination found was not associated with the hygiene or food storage problems observed. Conclusions: The results show that the hygiene-sanitary conditions of meat-based public school meals were unsatisfactory, demonstrating the need for improvements in the production process to preserve the health of the student population. Multidisciplinarity: Researchers from the areas of food microbiology, nutrition, public health and statistics took part in this study, a decisive factor for characterizing the research as multidisciplinary

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In Brazil school food is constitutionally guaranteed to public school students at the preschool and elementary level. This food must be nutritious, hygienic and sanitary. The aim of the present study was to assess the hygienic/sanitary conditions of food and table utensil handlers in municipal public schools in Natal, Brazil. In total, 27 public schools were assessed, using a checklist and microbiological analysis of the hands and table utensils. For the microbiological analyses of the hands, coliforms were analyzed at 45ºC and for the utensils aerobic mesophilic bacteria, using methods recognized by AOAC, 2002 and APHA, 1992, respectively. Most of the schools studied did not exhibit good food and utensil handling practice procedures in any of the variables analyzed. It was shown that 74.1% of the handlers received no periodic training, 51.9% did not undergo annual health examinations and 100% did not practice proper hand hygiene, which reflected significantly (p < 0.05) in hand contamination, where fecal coliforms were detected on 55.6% of the hands analyzed. With respect to the utensils, it was found that 100% of the schools studied did not follow correct hygiene practices and most were classified as very bad ; that is, aerobic mesophilic bacteria values above the limits established by PAHO (Pan American Health Organization), with schools in the north and south districts recording the highest percentages. The results show that the hygienic-sanitary conditions of the food and utensil handlers in the schools studied were inadequate, demonstrating the need for implanting good handling practices aimed at protecting the health of children that take part in the program and offering safer foods. Researchers from the areas of food microbiology, nutrition, public health and statistics participated in this study, a decisive factor for characterizing it as multidisciplinary

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coalho cheese is a typical product of the Northeastern Brazil, which is consumed both raw and cooked. The present work aimed to study the characteristics of artisanal and industrial processes in the production of coalho cheese sold in Natal / RN in order to evaluate its quality and consumer s profile. Four artisanal cheeses plants were monitored and a questionnaire was sent to different cheese industries. Besides this, eight cheese samples (four artisanal and four industrial) were evaluated in regard to the microbiological quality, physical-chemical and sensory attributes. The sensory acceptance was evaluated by using 108 non-trained panelists by using the hedonic scale. The consumer s profile survey was applied to 400 consumers of coalho cheese. The lack of hygiene control was detected at the artisanal cheese production, which uses raw milk as its raw material. Research has shown that the industrialized cheeses are made from pasteurized milk provided by their own production or by a third party, as observed in cheese making dairies. In general, the results indicate variation in the manufacturing process of coalho cheese, which results in the lack of product standardization. Regarding the physical-chemical analysis, most artisanal and industrial samples presented moisture content between 36 and 40 %, classified as medium moisture cheese, which is the only parameter that showed no significant difference (p>0.05). However, the water activity (Aw), pH and acidity results differed significantly. All artisanal samples showed coliform contamination at 35 °C, which confirms the poor hygienic conditions. In regard to coliforms at 45 °C, 75 % of artisanal coalho cheese samples had value higher than 103 MPN / g, a value above the lawful limits determined by RDC nº 12. Fifty percent of industrial coalho cheese samples showed coagulase-positive Staphylococcus values above the limit allowed by the RDC nº 12, indicating poor handling. The sensory evaluation revealed that the taste was the only parameter that showed significant difference, and this difference was only between two industrial brands. The consumer s survey showed that the coalho cheese flavor is the most important reason for buying this kind of cheese. Although coalho cheese is mainly bought in supermarkets, open street markets and country shops are still important selling points. It is concluded that there is no coalho cheese standardization in the RN state, which leads to variations in physical-chemical and sensory attributes. Moreover, it is necessary greater hygiene control in the production and handling procedures of coalho cheese.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The technology of anaerobic reactors for sanitary wastewater treatment has been extensively developed in Brazil, and today it is practically consolidated. They present several advantages, such as low construction and operating costs, and low sludge production, the anaerobic reactors are an attractive alternative to minimize problematic lack of basic sanitation in urban areas, and also of the rural areas. The anaerobic filters have been widely used in Brazil. It produces an effluent with low concentration of organic matter and solids suspended, besides conserving the nutrients, therefore, it is good for use in irrigation, but the practice must be associated with knowledge of the pathogens presence. The main objective of this study was to evaluate the efficiency of anaerobic filters in removal faecal coliforms and helminth eggs, and to verify if the effluent can be used for agricultural purposes, according to the World Organization of Health (WHO, 1989). The protocol used to enumerate helminths eggs was the modified Bailenger method, (Ayres and Mara, 1996) recommended by WHO for evaluation of raw effluent and treated effluent. The membrane filtration method was utilized to determine the concentrations of faecal coliforms. Three different systems of sewer treatment composed by anaerobic filters were analyzed. The results, in a general analysis, showed that all the researched systems reached a larger removal than 93% to helminth eggs, resulting in an effluent with smaller average than 1 egg/L. One of these systems, Sistema RN, reached a larger removal than 99%, confirming the good performance of the anaerobic filters in removal helminths eggs. Even with low concentrations of eggs in the influent, the filters were capable to remove this parameter efficiently. About faecal coliforms, it was observed for all the researched systems an effluent with 106 CFU/100mL. The high concentrations to faecal coliforms in the effluent just allow reuse for restricted irrigation, in agreement with the guidelines of WHO. Although the researched systems have not removed faecal coliforms efficiently, the results indicated a good efficiency of the anaerobic filters in removal helminth eggs

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the urban areas of the cities a larger problem of destiny of effluents of the treatment stations is verified due to the junction of the sewages in great volumes. This way the hidroponic cultive becomes important, for your intensive characteristic, as alternative of reuse. This work presents as objective the improvement of the relation hidric-nutritious of the hidroponic cultive of green forage (FVH) using treaty sewage. The production of forage was with corn (Zea mays L.), using double hybrid AG1051, in the experimental field of the Federal University of Rio Grande do Norte (UFRN), in the city of Natal-RN-Brazil. The treated effluent essentially domestic had origin of anaerobic reactor, type decant-digester of two cameras in series followed by anaerobic filters drowned. The hidroponic experimental system was composed of 08 stonemasons, with limited contours for masonry of drained ceramic brick, measuring each one 2,5 meters in length for 1,0 meter of width, with inclination of 4% (m/m) in the longitudinal sense, leveled carefully, in way to not to allow preferential roads in the flow. These dimensions, the useful area of Isow was of 2 square meters. The stonemasons of cultive were waterproof (found and lateral) with plastic canvas of 200 micres of thickness, in the white color. Controlled the entrance and exit of the effluente in the stonemasons, with cycles of 12,68 minutes, it being water of 1,18 minutes. The treatments were constituted of: T1 - 24 hours/day under it waters with flow of 2 L/min; T2 - 12 hours/day under waters with flow of 4 L/min; T3 - 12 hours/day under waters with flow of 2 L/min; and T4 - 16 hours/day under waters with flow of 3 L/min. There were evaluations of the evapotranspirometric demand, of hidroponic system affluent and effluent seeking to characterize and to monitor physical-chemical parameters as: pH, temperature, Electric Conductivity and Fecal Coliforms. This last one was analyzed to the 11 days after isow (DAS) and to the 14 DAS. The others were analyzed daily. I sow it was accomplished in the dates of February 21, 2007, first experiment, and April 10, 2007, second experiment. The density of Isow was of 2 kg of seeds, germinated before 48 hours, for square meter of stonemason. The statistic delineament was it casual entirely with two repetitions, in two experiments. It was applied Tukey test of average to five percent of probability. The cultivation cycle was of 14 DAS with evapotranspirometric demand maximum, reached by T1, of 67,44 mm/day. The analyzed parameters, as mass of green matter - Kg, productivity-Kg/m2 and reason of production of seed FVH/Kg used in Isow, the best result was presented by T1, obtaining value of up to 19,01 Kg/m2 of cultive. Without significant difference, the T4 presented greats values with 16 hours under cycle of water. The Treatments 2 and 3 with 12 hours under cycle of water, they obtained inferior results to the other Treatments. As treatment system, came efficient in the reduction of the salinity. T1 obtained reduction medium maxim of 62,5%, to the 7 DAS, in the amount of salts that enter in the system in they are absorbed in the cultivation. The cultivation FVH acted reducing the microbiologic load. Significant percentile of reduction they were reached, with up to 90,23% of reduction of Units of Colonies (UFC), constituting, like this, the Hidroponic System as good alternative of treatment of effluents of Reactors of high Efficiency

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In Natal still dominates the use of individual disposal systems for domestic sewage, once only 29% of the city has a sewarage system. Wastes that are accumulated in these individual treatment systems should be exhausted periodically, service provided by collector entrepreneurs. Some of these companies causing major damage to the environment. In Natal, only two companies have their own septage (RESTI) treatment system, which were designed with parameters from domestic sewage generating strain and inefficient systems. Therefore, the characterization becomes essential as a source of parameters for their design. Thus, this work presents the physical-chemical and microbiological characterization of waste pumped from individual sewage treatment systems. Samples collections were made weekly from 5 different trucks at the reception point on the treatment plant on the point of the preliminary treatment. From each truck it was taken 5 samples during the discharge in order to make a composite sample. Afterwards, samples were carried out to laboratory and analyses for determination of temperature, pH, conductivity, BOD, COD, nitrogen (ammonia e organic), alkalinity, oils, phosphorus, solids, faecal coliforms and helminth egg. The results were treated as a single database, and ranked according to its generating source (multi and single house, lodging, health, services and / or food), area of origin (metropolitan, south and north) and type of system (cesspits, septic tank and / or sink). Through these data it was possible to verify that the type of system adopted by most in Natal and the metropolitan region is cesspit, besides to confirm the difference between the septage of areas with a population have different social and economical characteristics. It was found that the septage have higher concentrations than domestic sewage, except for thermotolerant coliforms that showed concentrations of 1,38E+07. Among the parameters studied, is the median values identified for COD (3,549 mg / L), BOD (973mg / L) and total solids (3.557mg / L). The volatile fraction constitutes about 70% of the total solids of the septage. For helminths has been a median of 7 eggs/L. In general, the characteristics of the waste followed the variability found in the literature reviewed for all variables, showing high amplitudes

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The urban drainage is one of the powers of environmental sanitation and its scope is the quantitative and qualitative aspects. In decision making of managers and the engineering aspects of design are almost always taken into account only the quantitative aspects. However, the waters of the runoff have the highest concentrations of pollutants at the beginning of precipitation. Thus, if the plot pollution removed, the remaining portion can be used for other purposes. This work has aimed to present the variation of water quality of two drainage basins in the city of Natal / RN-Brazil to support the implementation of drainage to consider the qualitative aspect, and identify potential for the use of water. The basins (M and C) are analyzed closed-type, are in the urban area, are predominantly residential occupation and its waters are used for detention ponds and infiltration. The samples were divided into three phases, the first two direct to final points in a basin and the third in traps distributed over the surface drainage. The parameters had been analyzed were pH, conductivity, dissolved oxygen, Color, Turbidity, COD, Ammonia, nitrite, nitrate, total phosphorus, orthophosphate, Sediments solids, total solids, chloride, sulfate, alkalinity, calcium, magnesium, sodium, potassium, Heavy Metals (Chromium, Cadmium, Lead, Zinc and Copper), Eschichia coli and total coliforms. The parameters studied showed high initial pollution load, events and located in different proportions, except nitrite, heavy metals and biological indicators. The size of the surface drainage and topographic its features influence the quality of water. However, the form of sampling is crucial in the qualitative study in the basin. The samplers developed at work, were generated economic and representative results. The urban rainwater presents organic faecal indicators. The runoff of water from both basins shows no risk of salinity and sodicity for use in irrigation, should be noted the content of chloride in the choice of method of irrigation

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Because of disability in public policy development in mind to attend issues of sanitation in the municipalities, companies known as "clean-blue" appeared proposing to solve a simple collection and management of wastewater produced in single or multifamily residences, commercial, hospitals, etc. In the case of an activity in which there are no worries about the fate of sewage, emerged some doubts about the degree of health and environmental safety in these companies. Traditionally, most of them makes the provision of waste depleted soil or wetland, open, usually located on the outskirts of cities (MENESES, 2001). In turn, the sludge from septic tanks exhausted, provided no technical criteria - in the soil, rivers and as an agricultural fertilizer put in risk the health of the population and environmental quality. This work was entered in the search network 5 of the Notice of the Research Program in Sanitation - PROSAB-5, aimed to study the theme 'Characterization and study of alternative ways of treating sludge from septic tanks in the city of Natal, RN', proposing to evaluate the performance of the use of stabilization ponds as a system to handle waste from septic tanks exhausted. A series of lakes studied belong to one of the largest clean-pit of Natal, consisting of two anaerobic ponds, one facultative and maturation, and a tank disinfection, the wastewater being released in the Potengi River. Samples were collected between the months of October 2007 to October 2008, at six points previously defined and judged as more appropriate to what is proposed study. The analysis results in field and laboratory showed the most significant removal of COD (88.93%), total suspended solids (94.87%), organic nitrogen (66.87%) and thermotolerant coliforms (99.88%). Some results have not reached the expected because the system under study had operating problems that have undermined the efficiency of the reactors

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Pirangi beach is located in the eastern coastline of Rio Grande do Norte state, in the municipality of Parnamirim and Nísia Floresta. In it flow into Pirangi Watershed (PW), whose water receives large amounts of pollutants, mainly domestic and industrial sewage from districts where pass the rivers that consist it, compromising, thus, the bathing water quality of the Pirangi beach. Bearing in mind the importance of water sanitary quality to ensure an environment that no present risk to the bathers s health, this work had as main objective to assess the influence of the PW s waters in the bathing water quality of the Pirangi beaches. To that end, were made collections of water in the beaches and in the rivers with the intention of quantify the fecal contamination indicators thermotolerant coliforms and enterococci, to then classify the conditions of bathing water quality according with the CONAMA Resolution number 274 of 2000. For the purposes greater knowledge about the health conditions of the Beaches Pirangi and about the influence the PW s waters exert on it, was done parallely to the study of the water quality, an investigation of the sand sanitary quality. Furthermore, it was made an evaluation of the PW s Water Quality through Water Quality Index (WQI). Starting from the results obtained in the research present was possible to verify, among other aspects, that the entry of the PW s waters in the Pirangi beaches exerts direct influence in the bathing water quality of the same ones, being the North Pirangi beach (point tracking PA-02) the most influenced. There was noticed also a significant reduction in the conditions of bathing water quality of the beaches in the rainy season. However, the precariousness do sewerage system of the Natal metropolitan region and the absence of a right system of treatment an final disposal of domestic sewage and industrial are the main factors responsi le for deterioration of the PW s Water Quality, and as a consequence, compromising the bathing water quality of the Pirangi beaches

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Only 32% of the population of Natal is attended by sewage, while the remaining population use pits and septic tanks. The characterization of the contents of septic tanks and pits contributes to the performance of such system and may guide the decision on treatment of these contents. The main of this research is to characterize the contents of interior residential pits and septic tanks in the greater Natal, with the following specific goals: to develop and manufacture a sampler capable of collecting a representative sample of the entire column (the surface scum, the clarified liquid and sludge bottom); to compare the contents of the tanks with the pits; to compare the contents of the septage from vacuum trucks; to relate the composition content with socioeconomic characteristics of households; to compare the content in both chambers of the septic tanks in series; to assess the situation of the content before and six months after the cleanness; and ultimately propose a pilot scale plant for treatment of septage. Once the sampler was developed, samples were collected within 14 septic tanks and 10 pits in many districts of Natal. Medians of the 24 systems were obtained: temperature, pH, conductivity, oil and grease, total solids, total suspended solids and sediments of 28.0 °C, 6.95; 882 mS/cm, 75.2 mg/L; 10,169 mg/L, 6,509 mg/L and 175 mL/L respectively; 111.0 mgN/L for ammonia, 130.5 mgN/ L for organic nitrogen, 0.2 mgN/L for nitrite, 0.4 mg/L for nitrate; 8935 mgO2/L for COD, 29.2 mgP/L for total phosphorus, thermotolerant coliforms from 9.95 E +06 CFU/100mL helminth eggs and 9.2 eggs/L with a maximum concentration of 688 eggs/L and minimum of 0 eggs/L. Medians of organic nitrogen and TKN were significantly different between groups of tanks and pits. The systems with cleanness gap from 11 and 20 years presented the higher concentrations for most variables. The effluent from the toilets and bathrooms participate more effectively in contributing fractions of solids, alkalinity, nitrogen, COD, total phosphorus, thermotolerant coliforms and helminth eggs. The systems used by socioeconomics class with income from R$ 3,700.00 to R$ 7,600.00, presented higher concentrations for COD, nitrogen, solids and helminth eggs. The first of the two chambers had always presented higher concentrations over the second compartment. The analysis of variance for most variables, showed that the values of septic tanks, pits and septage from vacuum trucks belong to the same group. In the samples taken after cleanness, the median of pH and temperature increased, while alkalinity, COD, organic nitrogen, total phosphorus, ammonia and helminth eggs decreased. The oils and greases and thermotolerant coliforms had slightly varied due to the continuous release of sewage into the systems that maintained their steady state concentrations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stabilization pond system consisting in more sewage treatment used in Rio Grande do Norte (RN), Brazil, representing about 90% of all systems. Fecal bacteria are removed mainly facultative ponds and in maturation ponds. Many factors influence bacterial decay, such as the levels of pH and DO, temperature, light intensity, HDT and nutrient availability. The bacterial decay rate (Kb) is calculated considering many variables, but the hydraulic regime is a significant influence for microorganisms removal, and the dispersed flow which best characterizes a stabilization pond. However, some authors developed equations for the Kb accordant plug flow and complete mixing. This research study aimed to evaluate the bacterial decay of fecal coliform and Enterococcus sp. in stabilization ponds designed to treat domestic sewage, full-scale, in RN. All systems have assessed pretreatment, a facultative pond (LF) followed by two maturation (LM1 and LM2). The parameters availed were: temperature, pH, DO, BOD5, COD, fecal coliform, Enterococcus sp., Chlorophyll a, total suspended solids, fixed and volatile. In general, there were not significant differences for pH, DO and temperature in the ponds, except for the new systems, since they have low flow and hydraulic loads. The removal of organic matter in the ponds was low, about 70%, and nearly all are overloaded organic and operational problems. The bacterial removals were low, with average 96% for LF for fecal coliform, and 98% for Enterococcus sp.; LM1 were in itself a removal for fecal coliform about 71%, and 81% for Enterococcus sp.; LM2 have efficiency of 69% for fecal coliform, and 68% for Enterococcus sp. The equation proposed by Von Sperling (1999), according to the dispersed flow regime, generated empirical values of Kb more approximate to calculated values of Kb. On average, the calculated Kb to coliforms in the LF was 0.31 d-1, and for both maturation ponds were 0.35 d-1. For Enterococcus sp. the average was 0.40 d-1 for LF, 0.55 d-1 for LM1, and 0.58 d-1 for LM2. These results also showed that the Kb obtained in full-scale systems are smaller than those found in pilot-scale ponds. Moreover, one can say that the equation proposed by Marais (1974), according to the complete-mix regime, overestimates Kb. Actual results of Kb indicated that fecal coliforms are more resistant to adverse conditions present in stabilization ponds than Enterococcus sp., therefore, an indicator of microbiological safety and efficiency. The factors significant interventions in the rate of bacterial decay were concentrations of COD, the organic loading and HDT. The few Kb relationship between pH, DO and temperature were not significant. Finally, we conclude that it s essential to correct operation and maintenance, for not performing these activities is one of the main factors contributing to low rates of bacterial decay.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stabilization pond is the most used sewage treatment system in the country, corresponding to approximately 90% of all systems. The systems evaluated were stabilization ponds system of sewage treatment in the city of Natal / RN. This research aimed to analyze the possible uses through physical-chemical and bacteriological of these final effluent ponds for urban uses depending on the characteristics after passage around the treatment system. The parameters used were chosen according to those established by Chernicharo et al. (2006), in order to characterize the effluent. The parameters evaluated were: DO, temperature, pH, conductivity, organic nitrogen, ammonia, NTK, total phosphorus, and series of solid fecal coliforms. Generally, the characteristics of the effluent followed variability found in the literature. The results showed an efficiency that is technically feasible to use the effluent end of some of STPs analyzed when checked parameters alone, if fitting in unrestricted urban use, restricted use and urban land use

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Waste stabilization ponds are the main technology in use for domestic sewage treatment in Rio Grande do Norte State (RN), northeast Brazil. The are around 80 systems, constructed mainly by municipal city halls, being series comprised by a primary facultative pond followed by two maturation ponds the most used configuration. Due to problems related with the production and destination of sludge and generation of bad odors, the designers have avoided the use of anaerobic lagoons. The majority of systems are rarely monitored to verify their efficiencies and to get new project parameters for future designing. This work has as purpose to make a diagnosis of efficiency of three series of waste stabilization pond series (WSPS) of Jardim Lola 1, Jardim Lola 2 and Beira Rio, located in the North Zone of the city of the Natal/RN, treating domestic raw sewage, on the removal of organic matter and thermotolerant coliform, comparing the operational conditions of the systems this inside of the bands foreseen in the project, through parameters BOD5, QOD, thermotolerant coliforms, dissolved oxygen, pH, temperature, ammoniac nitrogen, total and suspended solids. The work was carried through in the WSPS, all constituted by a primary facultative pond followed by two maturation ponds. Socioeconomic characteristics of population are predominantly low and all the plants are very near of the contributing basins. The series were monitored from of May the November of 2002, totalizing 20 collections of grab samples of raw sewage and ponds effluents between 8:00 and 9:50 h. The main aspect to be detached by the results was the great concentration of organic matter (BOD and COD) and microorganisms the raw sewage which were around two times more concentrated than those values foreseen one in project. Considering all series the highest removals of organic matter were observed in system Beira Rio (84 and 78% of BOD and COD, respectively), which presented high hydraulic detention time (TDH = 89 days). On the other hand, Jardim Lola 1 and Jardim Lola 2 presented a much lower values of HDT (36 days and 18 days respectively) and their removals of BOD and COD were the same (76% and 60%, respectively). The Beira Rio WSPS, was the most efficient verified in relation to solids and ammonia, proving the great influence of the operational variables such as HDT and applied surface organic loadings on the performance of pond series. Although the treatment plants have reached efficiencies of thermotolerant coliforms around 99,999%, the concentrations in the final effluent can be considered very high for launching in aquatic bodies, particularly those produced by Jardim Lola 1 and Jardim Lola 2 series

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work intends to develop an approach based through scientific criteria in the operational diagnosis of ponds of stabilization, starting from analyses accomplished in loco and in laboratory of 78 systems of sewer treatment through ponds of stabilization in the State of Rio Grande do Norte. The objectives of the research are: to map, to evaluate and to diagnose the operational acting of the ponds of stabilization of the state of Rio Grande do Norte, through visits in loco and analyses laboratory; to build a SIG, through the map rain, locate the points of releases of sewages of the systems of existent ponds in Rio Grande do Norte, as well as operational data and his/her respective efficiency diagnosis in the removal of BOD and Coliforms Termotolerantes; to evaluate, in real scale, three systems of ponds of stabilization of RN in the operational efficiency for the parameters BOD5, COD, pH, Temperature, OD and Coliforms Termotolerantes. Of 78 ETEs of appraised RN just, 9% or 7 had maximum concepts in what concerns the removal of BOD and Coliforms Termotolerantes and 41% or 32, they had the worst concepts in term of operational efficiency. The flowing concentrations ETEs of RN of BOD and Coliforms were of 410mg/L and 2,50x107UFC/100ml, the predominant configuration is of the type F1+M1+M2, the relationship BOD/COD revealed for the sewer tributary characteristic biodegradable high. For the study of case of 3 ETEs, the best operational efficiencies in decreasing order were: Cidade (Municipal district), it Roça (State) and São Miguel (SAAE). The removals of final BOD were 51,6mg/L; 108,27mg/L and 62,6mg/L, tends efficiency of 82%; 74% and 81%. In term of coliforms removal in the final effluentes were 1,90x103UFC/100ml; 1,50x104UFC/100ml and 3,10x104UFC/100ml, tends efficiencies of 99,99%; 99,95% and 99,90%. In what it concerns the practice of agricultural reúso of cultures consumed raw, none of 3 ETEs assisted the parameters of the Resolution CONAMA 357/05, for other reúso practices, all assisted the categories B and C of OMS. For release in body receiving ETE Cidade just, they assist the demands of the resolution of CONAMA 357/05, by study of purification solemnity of the receiving body. The maintenance lack and operation; exclusive operator in ETEs and operation knowledge was the contributory factors for the operational fall in appraised ETEs of RN

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Contamination by complex mixtures of various origins has been explored and studied for decades. Radon is a naturally occurring environmental contaminant that causes carcinogenic effects. These emissions can cause mutations in the lung tissue, which can initiate a carcinogenic process. Thus the dam Creek Falls, located in the municipality of Lajes Pintadas, was chosen for the development of this study, since cancer rates in the region reach 9% of the population annually, with this, the main objective of this study was evaluate the mutagenicity and toxicity of Riacho da Cachoeira damunder the influence of radon. The methodology ecotoxicological tests were performed with Ceriodaphinia dubia, as well as tests with Tradescantia pallida genotoxicologicos and Oreochromis niloticus. To understand how the population of Pintadas Slabs realizes the environment, we performed a study of environmental perception. The test results indicated that the reservoir water is toxic to test organimos exposed, found heavy metals, chloride, total and fecal coliforms as well as radon levels above the maximum allowed under Brazilian law. These results can be justified because it is so complex samples composed of different compounds that interact only with each other or causing synergistic effects. It was concluded that the dam Creek Waterfall, is contaminated with radon, as well as heavy metals, coliforms and chloride, causing toxic effects to the natural community. Thus, further studies should be performed with the human population of the region, to verify that the high rates of cancer in the population of the municipality may be linked to the presence of natural radiation. Thus, it is expected that the competent bodies that administer the municipality of Lajes Pintadas take reasonable steps to minimize risks and ensure the health of the community that still makes use of the weir