5 resultados para Chest wall reconstruction
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
INTRODUCTION: Cardiac and pulmonary manifestations of the Chagas disease (CD) affect between 20-30% of the infected subjects. The chronic Chagas cardiomyopathy (CCC) has some peculiarities such as arrhythmias and, especially heart failure (HF) and is potentially lethal due to left ventricular dysfunction. How respiratory disorders, patients get progressive loss of functional capacity, which contributes to a poor quality of life related to disease. Measurements of lung volume by the movement of the chest wall surface are an alternative evaluation of lung function and kinematics of complex thoracoabdominal for these patients. OBJECTIVE: evaluate the kinematics of the thoracoabdominal complex through the regional pulmonary volumes and to correlate with functional evaluation of the cardiorrespiratory system in patients with Chagas disease at rest. MATERIALS AND METHODS: a cross-section study with 42 subjects had been divided in 3 groups, 15 composed for patients with CCC, 12 patients with HF of different etiologies and 15 healthful presented control group. An optoelectronic plethysmography (POE), Minnesota questionnaire, six minute walk test, spirometer and manovacuometer was used. RESULTS: It was observed in the 6MWT where group CRL presented greater distance 464,93±44,63m versus Group HF with 399,58± 32,1m (p=0,005) and group CCC 404±68,24m (p=0,015), both the groups presented difference statistics with regard to Group CRL. In the manovacuometer 54,59±19,98; of the group CCC and 42,11±13,52 of group IC found group CRL presented 81,31±15,25 of the predicted versus, presenting in relation to group CRL. In the POE it observed a major contribution in abdominal compartment in patients with IC if compared like CCC and control groups. On the basis of the questionnaire of quality of life of Minessota, verified a low one groups CCC and IC 43,2±15,2 and 44,4±13,1, respectively (p<0,05) when compared with the control group (19,6±17,31). CONCLUSION: it seems that the patients with CCC possess same functional and respiratory characteristics, observed for the POE, 6MWT, manovacuometer and spirometer to the patients of group HF, being able to consider similar interventions for this complementary group as therapeutical of this neglected disease
Resumo:
Background: Obesity leads to alteration of lung volumes and capacities due to accumulation of fat in the chest wall and abdomen. Few studies have shown that weight loss induced by surgery improves lung function. Our objective was to evaluate the anthropometric development, pulmonary function, respiratory muscle, strength and endurance after weight loss induced by bariatric surgery. Methods: We evaluated in pre and post operative period variables of weight, BMI, NC, WHR and spirometric and respiratory pressure. Results: 39 subjects were evaluated, with age mean 35.9 ± 10.9 years, predominantly by women (76.3%). The weight mean decreased from 124.8 ± 17.5 kg to 88.8 ± 14.28 kg in post operative. The mean BMI ranged from 47,9 ± 5,6 Kg/m² to 34,3 ± 4,75 Kg/m². There was a significant increase in FVC from 3,63 ± 0,94 to 4,01±1,03, FEV1 from 3,03 ± 0,72 to 3,39 ± 0,85, FEF 25-75% from 3,41 ± 0,72 to 3,82 ± 0,94, PEF from 6,56 ± 1,47 to 7,81 ± 1,69, ERV from 0,35 ± 0,39 to 0,66 ± 0,38, MVV ranged from 103,43 ± 22,21 to 137,27 ± 29,84, all of them to p<0,01. The MIP and MEP showed no significant difference in pre and post operative. It was noted that for every centimeter reduced in neck circumference, an increase of 0.06 in FVC and 5.98 in MVV is observed. This is also observed in weight and BMI. Conclusion: We conclude that weight loss induced by bariatric surgery in obese provides a significant improvement in lung function and reduction of fat around the neck is more important in the generation of lung volume than the reduction of BMI
Resumo:
Background: Obesity may affect the respiratory system, causing changes in respiratory function and in the pulmonary volumes and flows. Objectives: To evaluate the influence of obesity in the movement of thoracoabdominal complex at rest and during maximal voluntary ventilation (MVV), and the contribution between the different compartments of this complex and the volume changes of chest wall between obese and non-obese patients. Materials and Methods: We studied 16 patients divided into two groups: the obese group (n = 8) and group non-obese (n = 8). The two groups were homogeneous in terms of spirometric characteristics (FVC mean: 4.97 ± 0.6 L - 92.91 ± 10.17% predicted, and 4.52 ± 0.6 L - 93.59 ± 8.05%), age 25.6 ± 5.0 and 26.8 ± 4.9 years, in non-obese and obese respectively. BMI was 24.93 ± 3.0 and 39.18 ± 4.3 kg/m2 in the groups investigated. All subjects performed breathing calm and slow and maneuver MVV, during registration for optoelectronic plethysmography. Statistical analysis: we used the unpaired t test and Mann-Whitney. Results: Obese individuals had a lower percentage contribution of the rib cage abdominal (RCa) during breathing at rest and VVM. The variation of end expiratory (EELV) and end inspiratory (EILV) lung volumes were lower in obese subjects. It has been found asynchrony and higher distortion between compartments of thoracoabdominal complex in obese subjects when compared to non-obese. Conclusions: Central obesity impairs the ventilation lung, reducing to adaptation efforts and increasing the ventilatory work
Resumo:
Diversion colitis is a chronic inflammatory process affecting the dysfunctional colon, after a colostomy. It is postulated that nutritional deficiency of the colonic epithelium by the absence of short-chain fatty acids (SCFA) is one of the factors responsible for the appearance of DC and that their employment could reverse the morphological changes of the mucosa. The treatment of choice for fecal diversion colitis (DC) is the reconstruction of the intestinal tract, although they suggested therapeutic options using enemas. This study evaluates the effect of SCFA in atrophy and inflammation in excluded colonic segments before and after the installation DC. Forty Wistar rats were divided into four groups (n = 10 for each group), submitted colostomy with distal colon exclusion. Two control groups (A1 and B1) received rectally administered physiological saline, whereas two experimental groups (A2 and B2) received rectally administered short-chain fatty-acids. The A groups were prophylactically treated (5th to 40th days postoperatively), whereas the B groups were therapeutically treated (after postoperative day 40), for 07 days. Histological sections stained with HE were used for histological analysis of the thickness of the colonic mucosa excluded (t- Student p ≤0.05). Inflammatory reaction of the lamina propria and mucosa were measured with scores previously established (Mann Whitney p ≤ 0.05). There was a significant thickness recovery of the colonic mucosa in group B2 animals (p = 0.0001), which also exhibited a significant reduction in the number of eosinophilic polymorphonuclear cells in the lamina propria (p = 0.0126) and in the intestinal lumen (p = 0.0256). Group A2 did not prevent the mucosal atrophy and significant increases in the numbers of lymphocytes (p=0.0006) and 50 eosinophilic polymorphonuclear cells in the lamina propria of the mucosa (p = 0.0022). Therapeutic use of short-chain fatty-acids significantly reduced eosinophilic polymorphonuclear cell numbers in the intestinal wall and in the colonic lumen; it also reversed the atrophy of the colonic mucosa. Prophylactic use did not impede the development of mucosal atrophy
Resumo:
The manufacturing of above and below-knee prosthesis starts by taking surfac measurements of the patient s residual limb. This demands the making of a cartridg with appropriate fitting and customized to the profile of each patient. The traditiona process in public hospitals in Brazil begins with the completion of a record file (according to law nº388, of July 28, 1999 by the ministry of the health) for obtaining o the prosthesis, where it is identified the amputation level, equipment type, fitting type material, measures etc. Nowadays, that work is covered by the Brazilian Nationa Health Service (SUS) and is accomplished in a manual way being used commo measuring tapes characterizing a quite rudimentary, handmade work and without an accuracy.In this dissertation it is presented the development of a computer integrate tool that it include CAD theory, for visualization of both above and below-knee prosthesis in 3D (i.e. OrtoCAD), as well as, the design and the construction a low cos electro-mechanic 3D scanner (EMS). This apparatus is capable to automatically obtain geometric information of the stump or of the healthy leg while ensuring smalle uncertainty degree for all measurements. The methodology is based on reverse engineering concepts so that the EMS output is fed into the above mentioned academi CAD software in charge of the 3D computer graphics reconstruction of the residualimb s negative plaster cast or even the healthy leg s mirror image. The obtained results demonstrate that the proposed model is valid, because it allows the structura analysis to be performed based on the requested loads, boundary conditions, material chosen and wall thickness. Furthermore it allows the manufacturing of a prosthesis cartridge meeting high accuracy engineering patterns with consequent improvement in the quality of the overall production process