5 resultados para CD2
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
Among the waste generated in the petrochemical industry water associated with oil production is the most important. It is considered one of the great challenges due to the presence of considered toxic chemicals present in this composition. The presence of these substances difficult to reuse the water associated with the enhanced recovery processes, so that prior to their reuse or disposal, treatment is necessary. This paper aimed to study the removal efficiency of chemical species: Ba2+, Ni2+, Cd2+, Cu2+, Cr3+, Sr2+ and Zn2+, present in the composition of the water associated with oil production by electrocoagulation. The evaluation of removal of these chemical species was performed by laboratory tests using electrochemical batch reactors and continuous flow. Initial tests were performed with electrocoagulation of synthetic wastewater in batch reactor using iron electrode. Results of removal of Zn2+ and Ni2+ were 78 % and 59 % respectively. While the percentage of removed Ba2+ was 19 % by 30 minutes of treatment and by applying current of 1.10 A. The tests were performed on effluent batch reactor applying the electrochemical technique with stainless steel electrodes 304, the objective was to remove part of the dispersed oil and also of organic compounds in the effluent. Under the experimental conditions used, the maximum result was obtained TOG was 60 % and TOC was approximately 50 % compared to the initial concentration. In the experiments carried out in continuous reactor, with effluent semisynthetic, have been used electrodes of iron and aluminum and the results were 100 % removal of Cd2+, Cu2+, Cr3+ and Zn2+ and 77 % of Sr2+. These percentages were only attainable through the use of the iron electrode. However, when the electrode was replaced by aluminum, there was a reduction in the percentage of removal to 65 %, using the same flow rate and current. Therefore according to the results obtained using the iron electrode was more effective in removing these metals and the conditions of lower current and lower flow rate was satisfactory, as observed in the experimental design adopted
Resumo:
Chronic lymphocytic leukemia (B-CLL) is a clonal proliferation of mature B lymphocytes characterized by indolent clinical course. Biologically this clonallity is characterized by low expression of surface immunoglobulin (sIg) with restriction to a single immunoglobulin light chain associated with high expression of CD5 antigen and positivity to B cell antigens lymphocytes such as CD19, CD20 and CD23 and negativity to FMC7. The immunological profile and morphological analysis of lymphoid cells are the main means for the differential diagnosis of B-CLL from other chronic lymphoproliferative diseases. The aim of this study was to evaluate the expression pattern of a variety of membrane antigens in leukemic cells originating from patients with B-CLL. In this study, peripheral blood samples from 80 patients with B-CLL were analyzed by multiparametric flow cytometry in addition to routine hematologic exams, using a panel of monoclonal antibodies (MoAb): CD45/CD14, CD3/CD19/CD45, CD4/CD8 / CD3, CD20/CD5/CD3, CD3/CD16-56/CD45, CD2/CD7, FMC7/CD23, CD103/CD22/CD20, HLADR/CD38, CD10/CD19, CD1a, CD11b and also IgM/gD, kappa and lambda immunoglobulin light chains for the detection of surface immunoglobulin and clonal restriction for immunoglobulin light chain. The Hematological data were obtained from the hematological analyzer and cytomorphological analysis in blood film stained by Leishmann. The study samples consisted of 45 men and 35 women, ages ranging from 55 to 84 years (mean 65 years). Complete white blood count showed count ranging from 10.0 to 42.0 x 109/l. (mean 50.0 x 109/l) and lymphocytes count greater than 5.0 x 109/l in all cases. The neoplastic cells displayed B-CLL phenotype (CD5+/CD19+/CD20+/HLADR+/CD23+) in the vast majority of the cases, associated to failed to stain for T cell markers (CD1a, CD2, CD4, CD3, CD7, CD8), CD103, CD14 and FMC7. Leukemic cells of most patients also expressed low intensity of IgM and IgD with restricted kappa light chain, in most cases (59,7%). This observation highlights the importance of immunophenotyping for correct diagnosis of chronic lymphoproliferative syndromes and the panel of MoAb used was sufficient for diagnostic confirmation of B-CLL
Resumo:
In this work the organosilanes aminopropyltriethoxysilane, 3-mercaptopropyltryethoxisilane and n[-3-(trimetoxisilyl)propyl]ethylenetriamine, as well as tetraethylortosilicate (TEOS), were employed to produce, by sol-gel method, organofuncionalized silicon samples. The prepared samples were characterized by elementar analys by thermogravimetry and infrared spectroscopy. Those samples were employed to adsorb Cd2+, Pb2+, Ni2+ and Zn2+ from aqueous solutions (10, 20, 40, 60 and 80 mg L-1). In typical experiments, 50 mg of the organometrix was suspended in 20 mL of metal cation solutions at four different contact times: 30, 60, 90 and 120 minutes. The total amount of adsorbed cations were measured by atomic absorption spectrometry. To all investigated matrices, the following adsorption capacity was observed: Ni2+ > Zn2+ > Cd2+ > Pb2+. Such sequence is closely related with the cation radius, as well as the cation hardness
Resumo:
Despite the advances in the cure rate for acute myeloid leukemia, a considerable number of patients die from their disease due to the occurrence of multidrug resistance (MDR). Overexpression of the transporter proteins P-glycoprotein (Pgp) and multidrug resistance-associated protein (MRP) confer resistance to the treatment these leukemias. OBJECTIVE: To analyze the expression of the Gpp and MRP1 in patients with AML by flow cytometry (FC) and to determine the correlation between expression and demographic and also clinical and laboratorial variables. METHODS: Bone marrow and peripheral blood samples from 346 patients with a diagnosis of AML were assessed for the expression of Pgp and MRP1 by FC. RESULTS: The expression of Pgp and MRP1 was found in 111 (32.1%) and 133 (38.4%) patients, respectively, with greater prevalence in older patients and lower in adolescents, observing also a high incidence in patients with refractory disease, recurrence and secondary in comparison with the cases of de novo AML. Regarding the laboratory findings, we observed a higher correlation statistically significant between the expression of Pgp and MRP1 in AML CD34+ and FAB AML M7, M5A and M2 and lower the M3 subtype, not observed statistically significant correlation between the phenotype MDR and other laboratory data such with hemoglobin, leukocyte count, platelet count, aberrant expression of lymphoid antigens (CD2, CD7 and CD19) and clinical signs related to the disease. CONCLUSIONS: The results showed that the detection of MDR phenotype by flow cytometry can be a molecular marker for prognosis independent patients diagnosed with AML.
Resumo:
Heavy metals are present in industrial waste. These metals can generate a large environmental impact contaminating water, soil and plants. The chemical action of heavy metals has attracted environmental interest. In this context, this study aimed to test t he performance of electrochemical technologies for removing and quantifying heavy metals. First ly , the electroanalytical technique of stripping voltammetry with glassy carbon electrode (GC) was standardized in order to use this method for the quantificatio n of metals during their removal by electrocoagulation process (EC). A nalytical curves were evaluated to obtain reliability of the determin ation and quantification of Cd 2+ and Pb 2+ separately or in a mixture. Meanwhile , EC process was developed using an el ectrochemical cell in a continuous flow (EFC) for removing Pb 2+ and Cd 2+ . The se experiments were performed using Al parallel plates with 10 cm of diameter ( 63.5 cm 2 ) . The optimization of conditions for removing Pb 2+ and Cd 2+ , dissolved in 2 L of solution at 151 L h - 1 , were studied by applying different values of current for 30 min. Cd 2+ and Pb 2+ concentrations were monitored during electrolysis using stripping voltammetry. The results showed that the removal of Pb 2 + was effective when the EC pro cess is used, obtaining removals of 98% in 30 min. This behavior is dependent on the applied current, which implies an increase in power consumption. From the results also verified that the stripping voltammetry technique is quite reliable deter mining Pb 2+ concentration , when compared with the measurements obtained by atomic absorption method (AA). In view of this, t he second objective of this study was to evaluate the removal of Cd 2+ and Pb 2+ (mixture solution) by EC . Removal efficiency increasing current was confirmed when 93% and 100% of Cd 2+ and Pb 2+ was removed after 30 min . The increase in the current promotes the oxidation of sacrificial electrodes, and consequently increased amount of coagulant, which influences the removal of heavy metals in solution. Adsortive voltammetry is a fast, reliable, economical and simple way to determine Cd 2+ and Pb 2+ during their removal. I t is more economical than those normally used, which require the use of toxic and expensive reagents. Our results demonstrated the potential use of electroanalytical techniques to monitor the course of environmental interventions. Thus, the application of the two techniques associated can be a reliable way to monitor environmental impacts due to the pollution of aquatic ecosystems by heavy metals.