6 resultados para Battery terminal voltage

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The stability of synchronous generators connected to power grid has been the object of study and research for years. The interest in this matter is justified by the fact that much of the electricity produced worldwide is obtained with the use of synchronous generators. In this respect, studies have been proposed using conventional and unconventional control techniques such as fuzzy logic, neural networks, and adaptive controllers to increase the stabilitymargin of the systemduring sudden failures and transient disturbances. Thismaster thesis presents a robust unconventional control strategy for maintaining the stability of power systems and regulation of output voltage of synchronous generators connected to the grid. The proposed control strategy comprises the integration of a sliding surface with a linear controller. This control structure is designed to prevent the power system losing synchronism after a sudden failure and regulation of the terminal voltage of the generator after the fault. The feasibility of the proposed control strategy was experimentally tested in a salient pole synchronous generator of 5 kVA in a laboratory structure

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is a Cross-sectional and multi-disciplinary study whose population selection was made by department of human resources (composed by a Manager, an Oncologist and a Psychologist) from the hospital where this research was realized. They also collaborated with important information about the work of that professionals in the hospital. We also counted on a Statistic who made study design calculating the sample and analyzing data. This research issued Evaluating health professionals anxiety levels who care for cancer terminally ill and their feelings about that work as well as identifying the factors which have influence on it. 100 health professionals from the Hospital which is a reference on cancer caring in Brazil situated in the city of Natal, state of Rio Grande do Norte, participated of this research. There was a sample loss of 21%. Data were collected through a questionnaire and State-Trait Anxiety Inventory (STAI). Results showed that 15% of the professionals have low State Anxiety levels, 70% Medium State Anxiety levels and 15% high State anxiety levels. The Number of Patients and Working in another Institution have interfered in the anxiety levels. Doctors and Nursing Assistants and Technicians have got the highest high State Anxiety percentage (25%). 73% of them declare to feel some sort of different behavior and/or feelings in caring for terminally ill. The most remarkable professionals feelings were Suffering and Sadness, and Terminally ill Children was the most difficult age group to care for. We conclude that work overload and having more than one job can interfere in professional stress levels and anxiety. Dealing with terminally ill, specially children one, can cause on the professionals psychological suffering. It s recommended the development of supporting and training strategies to reduce and/or to prevent Stress and Anxiety high levels

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most algorithms for state estimation based on the classical model are just adequate for use in transmission networks. Few algorithms were developed specifically for distribution systems, probably because of the little amount of data available in real time. Most overhead feeders possess just current and voltage measurements at the middle voltage bus-bar at the substation. In this way, classical algorithms are of difficult implementation, even considering off-line acquired data as pseudo-measurements. However, the necessity of automating the operation of distribution networks, mainly in regard to the selectivity of protection systems, as well to implement possibilities of load transfer maneuvers, is changing the network planning policy. In this way, some equipments incorporating telemetry and command modules have been installed in order to improve operational features, and so increasing the amount of measurement data available in real-time in the System Operation Center (SOC). This encourages the development of a state estimator model, involving real-time information and pseudo-measurements of loads, that are built from typical power factors and utilization factors (demand factors) of distribution transformers. This work reports about the development of a new state estimation method, specific for radial distribution systems. The main algorithm of the method is based on the power summation load flow. The estimation is carried out piecewise, section by section of the feeder, going from the substation to the terminal nodes. For each section, a measurement model is built, resulting in a nonlinear overdetermined equations set, whose solution is achieved by the Gaussian normal equation. The estimated variables of a section are used as pseudo-measurements for the next section. In general, a measurement set for a generic section consists of pseudo-measurements of power flows and nodal voltages obtained from the previous section or measurements in real-time, if they exist -, besides pseudomeasurements of injected powers for the power summations, whose functions are the load flow equations, assuming that the network can be represented by its single-phase equivalent. The great advantage of the algorithm is its simplicity and low computational effort. Moreover, the algorithm is very efficient, in regard to the accuracy of the estimated values. Besides the power summation state estimator, this work shows how other algorithms could be adapted to provide state estimation of middle voltage substations and networks, namely Schweppes method and an algorithm based on current proportionality, that is usually adopted for network planning tasks. Both estimators were implemented not only as alternatives for the proposed method, but also looking for getting results that give support for its validation. Once in most cases no power measurement is performed at beginning of the feeder and this is required for implementing the power summation estimations method, a new algorithm for estimating the network variables at the middle voltage bus-bar was also developed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electric energy is essential to the development of modern society and its increasing demand in recent years, effect from population and economic growth, becomes the companies more interested in the quality and continuity of supply, factors regulated by ANEEL (Agência Nacional de Energia Elétrica). These factors must be attended when a permanent fault occurs in the system, where the defect location that caused the power interruption should be identified quickly, which is not a simple assignment because the current systems complexity. An example of this occurs in multiple terminals transmission lines, which interconnect existing circuits to feed the demand. These transmission lines have been adopted as a feasible solution to suply loads of magnitudes that do not justify economically the construction of new substations. This paper presents a fault location algorithm for multiple terminals transmission lines - two and three terminals. The location method is based on the use of voltage and current fundamental phasors, as well as the representation of the line through its series impedance. The wavelet transform is an effective mathematical tool in signals analysis with discontinuities and, therefore, is used to synchronize voltage and current data. The Fourier transform is another tool used in this work for extract voltage and current fundamental phasors. Tests to validate the location algorithm applicability used data from faulty signals simulated in ATP (Alternative Transients Program) as well as real data obtained from oscillographic recorders installed on CHESF s lines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low voltage solar panels increase the reliability of solar panels due to reduction of in series associations the configurations of photovoltaic cells. The low voltage generation requires DCDC converters devices with high efficiency, enabling raise and regulate the output voltage. This study analyzes the performance of a photovoltaic panel of Solarex, MSX model 77, configured to generate an open circuit voltage of 10.5 V, with load voltage of 8.5 V, with short circuit current of 9 A and a power of 77 W. The solar panel was assembled in the isolated photovoltaic system configuration, with and without energy storage as an interface with a DCDC converter, Booster topology. The converter was designed and fabricated using SMD (Surface Mounted Devices) technology IC (integrated circuit) that regulates its output voltage at 14.2 V, with an efficiency of 87% and providing the load a maximum power of 20.88 W. The system was installed and instrumented for measurement and acquisition of the following data: luminosities, average global radiation (data of INPE Instituto Nacional de Pesquisas Espaciais), solar panel and environment temperatures, solar panel and DC-DC converter output voltages, panel, inverter, and battery charge output currents. The photovoltaic system was initially tested in the laboratory (simulating its functioning in ideal conditions of operation) and then subjected to testing in real field conditions. The panel inclination angle was set at 5.5°, consistent with the latitude of Natal city. Factors such as climatic conditions (simultaneous variations of temperature, solar luminosities and ra diation on the panel), values of load resistance, lower limit of the maximum power required by the load (20.88 W) were predominant factors that panel does not operate with energy efficiency levels greater than 5 to 6%. The average converter efficiency designed in the field test reached 95%

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The SPPB provides information about physical function and is a predictor of adverse events in the elderly. Frailty is a multidimensional syndrome that increases susceptibility to diseases and disability. However it may be possible to prevent or postpone frailty if is identified early. Our objective is to analyze SPPB s ability in screening for frailty a community-dwelling young elderly from cities with distinct socioeconomic conditions. Methods: Data were originated from community dwelling adults (65-74 years old) in Canada (Saint Bruno; n = 60) and Brazil (Santa Cruz; n = 64). SPPB was used to assess physical performance. Frailty was defined as the presence of ≥ 3 of these criteria: weight loss, exhaustion, weakness, mobility limitation and low physical activity. One point was given for each criterion met, totalizing a frailty score ranged from 0 to 5. The Linear Regression and Receiver Operating Characteristics analyses were performed to evaluate the SPPB s screening ability. Results: Mean age was 69.48, 10.0% of the Saint Bruno s sample and 28.1% of Santa Cruz s were frail (p = 0.001), the SPPB score means were 9.6 and 8.5 respectively (p = 0.01). SPPB correlated with the frailty score (R2 = 0.33), with better results for Saint Bruno. A cutoff of 9 in SPPB had good sensitivity and specificity in discriminating frail from non frail in Saint Bruno (AUC = 0.81) but showed fair results in Santa Cruz (AUC = 0.61). Conclusion: The SPPB has moderate ability in predicting frailty among older adult s population, and is an useful test to identify people with good functionality and low frailty when SPPB scores are ≥9