3 resultados para BE-6

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ionic liquids (ILs) are organic compounds liquid at room temperature, good electrical conductors, with the potential to form as a means for electrolyte on electrolysis of water, in which the electrodes would not be subjected to such extreme conditions demanding chemistry [1]. This paper describes the synthesis, characterization and study of the feasibility of ionic liquid ionic liquid 1-methyl-3(2,6-(S)-dimethyloct-2-ene)-imidazole tetrafluoroborate (MDI-BF4) as electrolyte to produce hydrogen through electrolysis of water. The MDI-BF4 synthesized was characterized by thermal methods of analysis (Thermogravimetric Analysis - TG and Differential Scanning Calorimetry - DSC), mid-infrared spectroscopy with Fourier transform by method of attenuated total reflectance (FTIR-ATR), nuclear magnetic resonance spectroscopy of hydrogen (NMR 1H) and cyclic voltammetry (CV). Where thermal methods were used to calculate the yield of the synthesis of MDI-BF4 which was 88.84%, characterized infrared spectroscopy functional groups of the compound and the binding B-F 1053 cm-1; the NMR 1H analyzed and compared with literature data defines the structure of MDI-BF4 and the current density achieved by MDI-BF4 in the voltammogram shows that the LI can conduct electrical current indicating that the MDI-BF4 is a good electrolyte, and that their behavior does not change with the increasing concentration of water

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The process of urbanization in recent decades has generated considerable seriousness of problems relating to the use and occupation physical environment of cities. The concentration of population, economic activities and technological standards have reinforced an existing urban environment highly degraded as a consequence of the development style that leads to the predatory use of natural resources. In this context, cities as centers of production and consumption, have the most serious problems of environmental degradation. This study investigated the impacts of the municipal building projects to large-scale vertical in the town of Vila de Ponta Negra, Natal-RN, given the proximity to the Environmental Protection Area (ZPA-6) and considering its environmental importance , scenic, landscape and tourism for the city of Natal-RN. The fragility of the licensing process and the failure of the assumptions in the analysis, objective and subjective, for the granting of environmental permits for the building construction projects, specifically those set out in the surroundings of the Environmental Protection Area (ZPA-6) and fundamental importance of landscape and tourism for the city of Natal, has aroused the concern of local people in and of itself the Government, faced with the probable impacts that will affect greatly the Vila de Ponta Negra. The methodology used to achieve the intended objectives will be the literature review, questionnaire to the surrounding population and the Government, as well as findings on the spot, through the photographic record. The beneficiaries of the license, if the entrepreneurs, have been affected because of the granting of licensing act of investing large amount of capital in the works. Additionally, with distrust of the population, since they are to discredit the public system of environmental management have guessed by the probability of imbalance to the environment and structural damage to the Vila de Ponta Negra, where such failure to support energy, lack of regular supply of water , lack of sanitation and access roads sufficient for the flow of motor vehicles in these areas, among other factors. Thus, this work will contribute to the diagnosis and solutions to the problem in question, so that the Government will effectively fulfill its social management of ecologically balanced environment of continuing urban development in Natal, Brazil

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Backgroud: Obesity is a major public health problem and is related to the low physical capacity when obese are compared to no-obese people, however the cause of this limitation is not completely understood. The measurement associated of physiological response to the telemetric 6MWT adds information of metabolic and respiratory system for diagnose of the functional limitation. Objective: Analyze physiological, metabolic and ventilatory responses in women with different body fat during the 6MWT. Methods: 32 women (8 non-obese, 8 Overweight, 8 Obese and 8 morbidly obese) were evaluated for anthropometry, lung function and exercise capacity. Results: Morbidly obese walked the shortest distance (400.2±38.7m), had lower VO2/Kg (12.75±3.20l/Kg/min) and lower R (0.74± 0.11) in the 6MWT compared to other groups. Analyses of metabolic (VO2 and VCO2) and respiratory (VE, VT and BF) during the test did not identify differences between groups. The evaluation of cardiac function (O2 pulse) found higher values in the OM (12.3 ± 4.9ml/bat). Conclusion: The OM had worse performance in the 6MWT compared to other groups. The physical performance may be reduced in this population related to a protocol-dependent response because the speed of 6MWT is self-adjusted allows the individual himself select the intensity of the test, making it set at a speed where there is energy saving