5 resultados para BASE-LINE
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
The objective of this clinical study was to evaluate the effectiveness of the toothbrushing with and without fluoride and the daily fluoride rinse (NaF 0.05%) on produced white spot, in vivo. This was a clinical study, controlled, randomized and triple blind. Thirty patients were selected for orthodontics reasons from Orthodontics Specialization Course at the Brazilian Dental Association - Section of Rio Grande do Norte. In this study it was used 4 bicuspid upper and lower. They had orthodontic reason for extractions, in 35 days, at least. The sample had one hundred and twenty teeth that received orthodontic bands. The bands were fixed with polycarboxylate cement, and there was a space standardized between bands and one surface of teeth. The four bicuspid of each patients were randomized and nominated as A, B, C and D. These nominations determinated the sequence of the extractions and what was done in each tooth. All the patients had been submitted to the toothbrushing with or without fluoride for 35 days. After this period, the A tooth of each patient was extracted to serve as control. The others teeth (B, C and D) were extracted one by each week. The entire sample was analyzed through the clinical examination and by laser fluorescence (DIAGNOdent®) in three different times: before orthodontic bands, 28 days after fixed and then removed the bands and, the last one, 07 days after one of the three treatments (toothbrushing with or without fluoride, tooth paste with fluoride and mouth rinse with fluoride). At the beginning all groups (A, B, C and D) had the same conditions, no significant difference was found. The same situation was found in a clinical examination. The results of the DIAGNOdent® for the groups that used tooth paste without fluoride, with fluoride and mouth rinse with fluoride, after 28 days, there was no significant difference. Clinically, the white spot was formed in all teeth after 28 days. When it was compared the three treated groups, the group without fluoride in tooth paste had worst result than the others groups. But there was no significant association between the number of active and inactive white spots and the type of treatment that the teeth had received. The demineralization of the enamel surface, under the orthodontic bands, it happened in a few weeks. The exposition of the white spots in oral environmental resulted in an improvement, but it was not enough to return to the values from the base line, either for the toothbrushing and/or the use of fluorite mouth rinse. Mouth rinse and toothpaste with fluoride have showed to reduce the incidence of demineralization in the enamel, but none seems to be superior to another one in an in vivo study
Resumo:
This paper aims to build a notebook of activities that can help the teacher of elementary school mathematics. Topics covered are arithmetic and geometry and the activities proposed here were developed aiming print them a multicultural character. We take as a base line developed by Claudia Zaslavsky multiculturalism and reflected in his books "Games and activities worldwide" and "More games and activities worldwide." We structure our work around four themes: the symbol of the Olympic Games, the pyramids of Egypt, the Russian abacus abacus and Chinese. The first two themes allow you to explore basic concepts of geometry while the latter two themes allow us to explore numerical notation and arithmetic operations
Resumo:
The purpose of this study was evaluate the effectiveness of the chitosan at 0.4 with high molecular weight and high deacetylation degree mouthrinse over the total decrease of the streptococci, Streptococcus mutans, lactobaci/li and over the perceptible bacterial film and gingival bleeding indices. For that, a total of 68 healthy students between 11 and 13 years old, not allergic to crustacean and not users of antibiotics or antimicrobial agent for the last three months or during the treatment, was selected. From those, thirty two individuaIs used the mouthrinse test, and thirty six, the control one. The participants rinsed 10 mL of the solutions twice a day, one during the moming (which was supervised), and another one during the aftemoon (which was not supervised), for fifteen days. The saliva collect for the microbiological analysis, as well as the perceptible bacterial film and gingival bleeding indices check, were made before the use ofthe mouthrinses (base line), immediately after the last mouthrinse on the day (zero time) and fifteen days after (fifteen time). These data were collected at school and the saliva was carried inside the ice to the laboratory. The samples were diluted, and 0.1 mL ofthe 10 -1 dilution was seeded in Rogosa SL agar, for further analysis of the total of lactobaci/lus~ 0.1 mL of the 10-4 dilution in Mitis Salivarius with bacitracin, for S. mutans analysis; and 0.1 mL of the 10-6 dilution in Mitis Salivarius for the analysis ofthe total of streptococcus. The Rogosa SL agar plates were incubated in aerobic at 37°C for 72 hours and the MSB and the MS were incubated in anaerobic in Gaspak@ jars at 37°C for 48 hours for further count ofColonies Former Units (CFUs). The assay was made in duplicate for each bacterial group analyzed. The number of CFUs transformed in LOGlO was analyzed according to the following tests: ANOV A, t of Paired and Not Paired Student, Friedman, Man-Whitney and square-qui test. On the base line, alI the variables analyzed were similar on both tested groups. On both groups, for the total of streptococcus there was no significant difference along the time and for S. mutans there was a statistic significant increase of the CFUs from the base line to the zero time. For the total of lactobaccilus there was no significant difference on the test group along the time, and on the control there was a significant increase ofthe CFUs ITom the base line to the zero time. For both groups, there was significant decrease ofthe perceptible bacterial film index along the time, and that can be explained by the mechanic effect of the mouthrinse over the bacterial film and by the participation of the students on the research which could have motivated him to a better toothbrushing (Hawthome effect). The gingival bleeding index also showed a decrease along the time, even though it was not significant. Therefore, the conclusion of this study was that the chitosan at 0.4 % mouthrinse was not effective on the CFUs reduction of the three bacterial groups analyzed, as well as on the reduction of the perceptible bacterial film and gingival bleeding indices
Resumo:
This paper proposes a procedure to control on-line processes for attributes, using an Shewhart control chart with two control limits (warning limit and control limit) and will be based on a sequence of inspection (h). The inspection procedure is based on Taguchi et al. (1989), in which to inspect the item, if the number of non-conformities is higher than an upper control limit, the process needs to be stopped and some adjustment is required; and, if the last inspection h, from all items inspected present a number of non-conformities between the control limit and warning limit. The items inspected will suffer destructive inspection, being discarded after inspection. Properties of an ergodic Markov chain are used to get the expression of average cost per item and the aim was the determination of four optimized parameters: the sampling interval of the inspections (m); the constant W to draw the warning limit (W); the constant C to draw the control limit (C), where W £ C, and the length of sequence of inspections (h). Numerical examples illustrate the proposed procedure
Resumo:
Most algorithms for state estimation based on the classical model are just adequate for use in transmission networks. Few algorithms were developed specifically for distribution systems, probably because of the little amount of data available in real time. Most overhead feeders possess just current and voltage measurements at the middle voltage bus-bar at the substation. In this way, classical algorithms are of difficult implementation, even considering off-line acquired data as pseudo-measurements. However, the necessity of automating the operation of distribution networks, mainly in regard to the selectivity of protection systems, as well to implement possibilities of load transfer maneuvers, is changing the network planning policy. In this way, some equipments incorporating telemetry and command modules have been installed in order to improve operational features, and so increasing the amount of measurement data available in real-time in the System Operation Center (SOC). This encourages the development of a state estimator model, involving real-time information and pseudo-measurements of loads, that are built from typical power factors and utilization factors (demand factors) of distribution transformers. This work reports about the development of a new state estimation method, specific for radial distribution systems. The main algorithm of the method is based on the power summation load flow. The estimation is carried out piecewise, section by section of the feeder, going from the substation to the terminal nodes. For each section, a measurement model is built, resulting in a nonlinear overdetermined equations set, whose solution is achieved by the Gaussian normal equation. The estimated variables of a section are used as pseudo-measurements for the next section. In general, a measurement set for a generic section consists of pseudo-measurements of power flows and nodal voltages obtained from the previous section or measurements in real-time, if they exist -, besides pseudomeasurements of injected powers for the power summations, whose functions are the load flow equations, assuming that the network can be represented by its single-phase equivalent. The great advantage of the algorithm is its simplicity and low computational effort. Moreover, the algorithm is very efficient, in regard to the accuracy of the estimated values. Besides the power summation state estimator, this work shows how other algorithms could be adapted to provide state estimation of middle voltage substations and networks, namely Schweppes method and an algorithm based on current proportionality, that is usually adopted for network planning tasks. Both estimators were implemented not only as alternatives for the proposed method, but also looking for getting results that give support for its validation. Once in most cases no power measurement is performed at beginning of the feeder and this is required for implementing the power summation estimations method, a new algorithm for estimating the network variables at the middle voltage bus-bar was also developed