3 resultados para Amputation.

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Malnutrition, inflammation and comorbidities are frequent in patients with chronic renal failure in hemodialysis (HD), contributing for morbidity and mortality. Aims: To evaluate the correlation between anthropometric, laboratory parameters, bioelectrical impedance (BIA) and inflammatory markers with the morbidity and mortality of patients in HD, as well as the impact of its alterations throughout 12 months. Methods: 143 patients of a dialysis facility in Northeast Brazil were evaluated throughout 18 months. Patients with more than 3 months on dialysis, older than 18 years, without amputation of hands and feet, were included in the study. We performed a clinical (subjective global assessment - SGA), anthropometric (BMI, percent of ideal weight, MAC, MAMC, MAMA, percent of fat mass and TSF), laboratory (albumin, creatinine, lymphocyte count as nutritional markers and CRP, IL-6 and TNF- as inflammatory markers) evaluation and BIA (reactance, phase angle and percent of body cell mass) at the beginning of study and after 3, 6 and 12 months of follow-up. The association between study variables and deaths and hospitalizations in 6 and 12 months was investigated. The variable with significance < 10% in the univariate analysis had been enclosed in a multivariate logistic regression analysis. We also investigated the risk of mortality and hospitalization associated with differences in measurements of the variables at baseline and six months later. Results: Patients were aged 52.2 ± 16.6 years on the average, 58% were male, and mean dialysis vintage was 5.27 ± 5.12 years. The prevalence of malnutrition varied from 7.7-63.6%, according to the nutritional marker. The variables associated with morbidity and mortality in 6 and 12 months had been creatinine ≤ 9.45 mg/dl, phase angle ≤ 4.57 degrees, BMI ≤ 23 kg/m2, age ≤ 64.9 years, reactance ≤ 51.7 ohms; Charlson´s index ≥ 4 and socioeconomic status ≤ 7. During six months of follow up, decrease in albumin was associated with significantly higher mortality risk. Conclusions: This study detected that the best predictors of morbidity and mortality between nutritional and inflammatory markers are phase angle, reactance, creatinine and BMI and that changes in albumin values over six 107 months provide additional prognostic information. The authors believe that parameters of BIA may detect early changes in nutritional status and emphasize that longitudinal studies with larger number of patients are necessary to confirm these data and to recommend BIA as a routine nutritional evaluation in HD patients

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The manufacturing of above and below-knee prosthesis starts by taking surfac measurements of the patient s residual limb. This demands the making of a cartridg with appropriate fitting and customized to the profile of each patient. The traditiona process in public hospitals in Brazil begins with the completion of a record file (according to law nº388, of July 28, 1999 by the ministry of the health) for obtaining o the prosthesis, where it is identified the amputation level, equipment type, fitting type material, measures etc. Nowadays, that work is covered by the Brazilian Nationa Health Service (SUS) and is accomplished in a manual way being used commo measuring tapes characterizing a quite rudimentary, handmade work and without an accuracy.In this dissertation it is presented the development of a computer integrate tool that it include CAD theory, for visualization of both above and below-knee prosthesis in 3D (i.e. OrtoCAD), as well as, the design and the construction a low cos electro-mechanic 3D scanner (EMS). This apparatus is capable to automatically obtain geometric information of the stump or of the healthy leg while ensuring smalle uncertainty degree for all measurements. The methodology is based on reverse engineering concepts so that the EMS output is fed into the above mentioned academi CAD software in charge of the 3D computer graphics reconstruction of the residualimb s negative plaster cast or even the healthy leg s mirror image. The obtained results demonstrate that the proposed model is valid, because it allows the structura analysis to be performed based on the requested loads, boundary conditions, material chosen and wall thickness. Furthermore it allows the manufacturing of a prosthesis cartridge meeting high accuracy engineering patterns with consequent improvement in the quality of the overall production process

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The manufacture of prostheses for lower limb amputees (transfemural and transtibial) requires the preparation of a cartridge with appropriate and custom fit to the profile of each patient. The traditional process to the patients, mainly in public hospitals in Brazil, begins with the completion of a form where types of equipment, plugins, measures, levels of amputation etc. are identified. Currently, such work is carried out manually using a common metric tape and caliper of wood to take the measures of the stump, featuring a very rudimentary, and with a high degree of uncertainty geometry of the final product. To address this problem, it was necessary to act in two simultaneously and correlated directions. Originally, it was developed an integrated tool for viewing 3D CAD for transfemoral types of prostheses and transtibial called OrtoCAD I. At the same time, it was necessary to design and build a reader Mechanical equipment (sort of three-dimensional scanner simplified) able to obtain, automatically and with accuracy, the geometric information of either of the stump or the healthy leg. The methodology includes the application of concepts of reverse engineering to computationally generate the representation of the stump and/or the reverse image of the healthy member. The materials used in the manufacturing of prostheses nor always obey to a technical scientific criteria, because, if by one way it meets the criteria of resistance, by the other, it brings serious problems mainly due to excess of weight. This causes to the user various disorders due to lack of conformity. That problem was addressed with the creation of a hybrid composite material for the manufacture of cartridges of prostheses. Using the Reader Fitter and OrtoCAD, the new composite material, which aggregates the mechanical properties of strength and rigidity on important parameters such as low weight and low cost, it can be defined in its better way. Besides, it brings a reduction of up steps in the current processes of manufacturing or even the feasibility of using new processes, in the industries, in order to obtain the prostheses. In this sense, the hybridization of the composite with the combination of natural and synthetic fibers can be a viable solution to the challenges offered above