8 resultados para AQUEOUS TWO-PHASE SYSTEM

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fucans are a family of sulfated homo and teropolysaccharides respectively, composed mainly of a- (1®2) and a- (1®3) linked by L-fucose residues. Properties such as the ability to act as an anti-contraceptive, to reduce cholesterol levels, and to act as an anti-tumor agent are much related. We have focused our attention on the anticoagulant properties, platelet aggregation, hemorrhagic activity and complement system in vitro of commercial fucoidan (F) and their purified fractions (F1, F2 and F3) from Fucus vesiculosus obtained from fractionation of the fucoidan with different concentrations of acetone 1, 2 and 3v. These compounds were chemically characterized and the fucoidan (F) was modified by desulfation. The anticoagulant activity of the compounds was assessment by activated partial thromboplastin time (APTT) and prothrombine time assay (PT) using citrated normal human plasma. The results of APPT test showed that F, F1 and F2 have high anticoagulants activities 240.0 s (5 µg). The F3 showed 73.7 s in the same concentrations. The results obtained with PT test to F, F1, F2 and F3 were 81.5 s, 120.0 s, 57.1 and 32.5 s respectively with 50 µg. The dessulfated polymer showed a decrease in the anticoagulant activity in these two tests. Platelet aggregation assay was measured turbidimetrically with platelet aggregometer by method of Born. The aggregation platelet with F and fractions F1, F2 and F3 exhibited a two-phase answer in the concentration of 5 mg/mL with maximum aggregation of 76.36 ± 10.3% ; 69.54 ± 9.40%; 75.94 ± 9.01%; 51.13 ± 9.59% respectively. However, was observed a hipoaggregate profile F (15.17 ± 5.2%), F1 (7.40 ± 3.04 %), F2 (19.1 ± 5.41%) and F3 (5.09 ± 3.02%) at 0.1 mg/mL. The hemorrhagic activity assay was carried in Wistar rats and showed that these compounds have low hemorrhagic effect when compared to heparin. The complement system ( alternative pathway was made using non-sensibilized rabbit red blood cells The results of complement system essay showed that F , F2 and F3 have action inhibitory in relation to the group control 0.544, 0.697, 0.622 and 0.958 respectively The results showed that these compounds have action on this system. Interaction of the polisaccharides with proteins C3 and C4 showed that the fraction F1 stimulated the activity assay hemolytic using red blood cells

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work intends to analyze the behavior of the gas flow of plunger lift wells producing to well testing separators in offshore production platforms to aim a technical procedure to estimate the gas flow during the slug production period. The motivation for this work appeared from the expectation of some wells equipped with plunger lift method by PETROBRAS in Ubarana sea field located at Rio Grande do Norte State coast where the produced fluids measurement is made in well testing separators at the platform. The oil artificial lift method called plunger lift is used when the available energy of the reservoir is not high enough to overcome all the necessary load losses to lift the oil from the bottom of the well to the surface continuously. This method consists, basically, in one free piston acting as a mechanical interface between the formation gas and the produced liquids, greatly increasing the well s lifting efficiency. A pneumatic control valve is mounted at the flow line to control the cycles. When this valve opens, the plunger starts to move from the bottom to the surface of the well lifting all the oil and gas that are above it until to reach the well test separator where the fluids are measured. The well test separator is used to measure all the volumes produced by the well during a certain period of time called production test. In most cases, the separators are designed to measure stabilized flow, in other words, reasonably constant flow by the use of level and pressure electronic controllers (PLC) and by assumption of a steady pressure inside the separator. With plunger lift wells the liquid and gas flow at the surface are cyclical and unstable what causes the appearance of slugs inside the separator, mainly in the gas phase, because introduce significant errors in the measurement system (e.g.: overrange error). The flow gas analysis proposed in this work is based on two mathematical models used together: i) a plunger lift well model proposed by Baruzzi [1] with later modifications made by Bolonhini [2] to built a plunger lift simulator; ii) a two-phase separator model (gas + liquid) based from a three-phase separator model (gas + oil + water) proposed by Nunes [3]. Based on the models above and with field data collected from the well test separator of PUB-02 platform (Ubarana sea field) it was possible to demonstrate that the output gas flow of the separator can be estimate, with a reasonable precision, from the control signal of the Pressure Control Valve (PCV). Several models of the System Identification Toolbox from MATLAB® were analyzed to evaluate which one better fit to the data collected from the field. For validation of the models, it was used the AIC criterion, as well as a variant of the cross validation criterion. The ARX model performance was the best one to fit to the data and, this way, we decided to evaluate a recursive algorithm (RARX) also with real time data. The results were quite promising that indicating the viability to estimate the output gas flow rate from a plunger lift well producing to a well test separator, with the built-in information of the control signal to the PCV

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Layered Double Hydroxides has become extremely promising materials due to its range of applications, easily obtained in the laboratory and reusability after calcination, so the knowledge regarding their properties is of utmost importance. In this study were synthesized layered double hydroxides of two systems, Mg-Al and Zn-Al, and such materials were analyzed with X-ray diffraction and, from these data, we determined the volume density, planar atomic density, size crystallite, lattice parameters, interplanar spacing and interlayer space available. Such materials were also subjected to thermogravimetric analysis reasons for heating 5, 10, 20 and 25 ° C / min to determine kinetic parameters for the formation of metaphases HTD and HTB based on theoretical models Ozawa, Flynn-Wall Starink and Model Free Kinetics. In addition, the layered double hydroxides synthesized in this working ratios were calcined heating 2.5 ° C / min and 20 ° C / min, and tested for adsorption of nitrate anion in aqueous solution batch system at time intervals 5 min, 15 min, 30 min, 1h, 2h and 4h. Such calcined materials were also subjected to exposure to the atmosphere and at intervals of 1 week, 2 weeks and 1 month were analyzed by infrared spectroscopy to study the kinetics of regeneration determining structural called "memory effect"

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fucans are a family of sulfated homo and teropolysaccharides respectively, composed mainly of a- (1®2) and a- (1®3) linked by L-fucose residues. Properties such as the ability to act as an anti-contraceptive, to reduce cholesterol levels, and to act as an anti-tumor agent are much related. We have focused our attention on the anticoagulant properties, platelet aggregation, hemorrhagic activity and complement system in vitro of commercial fucoidan (F) and their purified fractions (F1, F2 and F3) from Fucus vesiculosus obtained from fractionation of the fucoidan with different concentrations of acetone 1, 2 and 3v. These compounds were chemically characterized and the fucoidan (F) was modified by desulfation. The anticoagulant activity of the compounds was assessment by activated partial thromboplastin time (APTT) and prothrombine time assay (PT) using citrated normal human plasma. The results of APPT test showed that F, F1 and F2 have high anticoagulants activities 240.0 s (5 µg). The F3 showed 73.7 s in the same concentrations. The results obtained with PT test to F, F1, F2 and F3 were 81.5 s, 120.0 s, 57.1 and 32.5 s respectively with 50 µg. The dessulfated polymer showed a decrease in the anticoagulant activity in these two tests. Platelet aggregation assay was measured turbidimetrically with platelet aggregometer by method of Born. The aggregation platelet with F and fractions F1, F2 and F3 exhibited a two-phase answer in the concentration of 5 mg/mL with maximum aggregation of 76.36 ± 10.3% ; 69.54 ± 9.40%; 75.94 ± 9.01%; 51.13 ± 9.59% respectively. However, was observed a hipoaggregate profile F (15.17 ± 5.2%), F1 (7.40 ± 3.04 %), F2 (19.1 ± 5.41%) and F3 (5.09 ± 3.02%) at 0.1 mg/mL. The hemorrhagic activity assay was carried in Wistar rats and showed that these compounds have low hemorrhagic effect when compared to heparin. The complement system ( alternative pathway was made using non-sensibilized rabbit red blood cells The results of complement system essay showed that F , F2 and F3 have action inhibitory in relation to the group control 0.544, 0.697, 0.622 and 0.958 respectively The results showed that these compounds have action on this system. Interaction of the polisaccharides with proteins C3 and C4 showed that the fraction F1 stimulated the activity assay hemolytic using red blood cells

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Oil production and exploration techniques have evolved in the last decades in order to increase fluid flows and optimize how the required equipment are used. The base functioning of Electric Submersible Pumping (ESP) lift method is the use of an electric downhole motor to move a centrifugal pump and transport the fluids to the surface. The Electric Submersible Pumping is an option that has been gaining ground among the methods of Artificial Lift due to the ability to handle a large flow of liquid in onshore and offshore environments. The performance of a well equipped with ESP systems is intrinsically related to the centrifugal pump operation. It is the pump that has the function to turn the motor power into Head. In this present work, a computer model to analyze the three-dimensional flow in a centrifugal pump used in Electric Submersible Pumping has been developed. Through the commercial program, ANSYS® CFX®, initially using water as fluid flow, the geometry and simulation parameters have been defined in order to obtain an approximation of what occurs inside the channels of the impeller and diffuser pump in terms of flow. Three different geometry conditions were initially tested to determine which is most suitable to solving the problem. After choosing the most appropriate geometry, three mesh conditions were analyzed and the obtained values were compared to the experimental characteristic curve of Head provided by the manufacturer. The results have approached the experimental curve, the simulation time and the model convergence were satisfactory if it is considered that the studied problem involves numerical analysis. After the tests with water, oil was used in the simulations. The results were compared to a methodology used in the petroleum industry to correct viscosity. In general, for models with water and oil, the results with single-phase fluids were coherent with the experimental curves and, through three-dimensional computer models, they are a preliminary evaluation for the analysis of the two-phase flow inside the channels of centrifugal pump used in ESP systems

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Polycystic ovary syndrame (PCOS) has been shown to cause a reduction in quality of life. Little is known on the psychosocial aspects associated with PCOS, especially on women s own experiences regarding the syndrome. Therefore, the aim of this study was to analyze the psychosocial impact of PCOS by measuring the health-related quality of life and exploring the women s own experiences of PCOS. METHODS: A two-phase model of combination of quantitative and qualitative research approaches was conducted, a crass-sectional survey to pravide quantitative data on the quality of life and a qualitative approach to understand the women s experience in relation to the PC OS sympt?ms. For the first phase, 109 women with PC OS and 104 healthy contrais were evaluated with the 36-item short-form health survey (SF-36). Additionally, semi-structured interviews (n=30) were conducted to facilitate in-depth exploration of PC OS women s experience. RESUL TS: PCOS patients showed significant reductions in almost ali SF-36 domains of quality of life when compared with healthy contrais (physical function 76.5:!:20.5 and 84.6:!:15.9, respectively; physical rale function 56.4:!:43.3 and 72.6:!:33.3; general health 55.2:!:21.0 and 62.5:!:17.2; vitality 49.6:!:21.3 and 55.3:!:21.3; social function 55.3:!:32.4 and 66.2:!:26.7; emotional rale function 34.2:!:39.7 and 52.9:!:38.2; mental health 50.6:!:22.8 and 59.2:!:20.2). Thematic analysis revealed reports of feeling abnormal , sadness, afraid and anxiety. These feelings were related to four symptoms commonly experienced by women with PCOS: excess hair grawth; irregular or absent menstruation, infertility and obesity. CONCLUSIONS: Polycystic ovary syndrame impacts women both physically and psychosocially. Owing to this, women with PCOS need not only medical treatment for. the reproductive, esthetic and metabolic repercussions, but also the care of a multidisciplinary team, since PCOS is not just a physical condition, but also an important psychosocial problem that affects various aspects of a woman s life

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tuberculosis is a serious disease, but curable in practically 100% of new cases, since complied the principles of modern chemotherapy. Isoniazid (ISN), Rifampicin (RIF), Pyrazinamide (PYR) and Chloride Ethambutol (ETA) are considered first line drugs in the treatment of tuberculosis, by combining the highest level of efficiency with acceptable degree of toxicity. Concerning USP 33 - NF28 (2010) the chromatography analysis to 3 of 4 drugs (ISN, PYR and RIF) last in average 15 minutes and 10 minutes more to obtain the 4th drug (ETA) using a column and mobile phase mixture different, becoming its industrial application unfavorable. Thus, many studies have being carried out to minimize this problem. An alternative would use the UFLC, which is based with the same principles of HPLC, however it uses stationary phases with particles smaller than 2 μm. Therefore, this study goals to develop and validate new analytical methods to determine simultaneously the drugs by HPLC/DAD and UFLC/DAD. For this, a analytical screening was carried out, which verified that is necessary a gradient of mobile phase system A (acetate buffer:methanol 94:6 v/v) and B (acetate buffer:acetonitrile 55:45 v/v). Furthermore, to the development and optimization of the method in HPLC and UFLC, with achievement of the values of system suitability into the criteria limits required for both techniques, the validations have began. Standard solutions and tablets test solutions were prepared and injected into HPLC and UFLC, containing 0.008 mg/mL ISN, 0.043 mg/mL PYR, 0.030 mg.mL-1 ETA and 0.016 mg/mL RIF. The validation of analytical methods for HPLC and UFLC was carried out with the determination of specificity/selectivity, analytical curve, linearity, precision, limits of detection and quantification, accuracy and robustness. The methods were adequate for determination of 4 drugs separately without interfered with the others. Precise, due to the fact of the methods demonstrated since with the days variation, besides the repeatability, the values were into the level required by the regular agency. Linear (R> 0,99), once the methods were capable to demonstrate results directly proportional to the concentration of the analyte sample, within of specified range. Accurate, once the methods were capable to present values of variation coefficient and recovery percentage into the required limits (98 to 102%). The methods showed LOD and LOQ very low showing the high sensitivity of the methods for the four drugs. The robustness of the methods were evaluate, facing the temperature and flow changes, where they showed robustness just with the preview conditions established of temperature and flow, abrupt changes may influence with the results of methods

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The petroleum industry deals with problems which are difficult to solve because of their relation to environmental issues. This is because amounts of residue are generated which vary in type and danger level. The soil contamination by non aqueous liquid phase mixtures, specifically hydrocarbon petroleum has been a reason for great concern, mainly the aromatic and polycyclic aromatic, which present risk to human health due to its carcinogenic and mutagenic character. The Advanced Oxidative Processes (AOP) are efficient technologies for destruction of organic compounds of difficult degradation and, often, they are present in low concentrations. They can be considered clean technologies, because there is no formation of solid by-products or the transfer of pollutor phases. This work focuses on the study of the degradation of petroleum industrial waste, by Advanced Oxidation Processes. Treatments tackling petroleum residues, contaminated soil, and water occurring in the production of petroleum reached the following Polycyclic Aromatic Hydrocarbons (PAH) degradation levels: solid residues 100% in 96 treatment hours; water residue - 100% in 6 treatment hours; soil contamination (COT degradation) - 50.3% in 12 treatment hours. AOP were effective in dealing with petroleum residues thus revealing themselves to be a promising treatment alternative