9 resultados para 6-min walk distance
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
Physical Exercise (PE) is a necessary component in the management in COPD patients, where respiratory symptoms are associated with reduced functional capacity. Even with the increase in the number of studies that have been published and the therapeutics success using aquatic therapy approach, studies using PE in water in COPD patients are so few. Objective: the aim of this present study was to analyze the effects of low intensity water exercise in COPD patients, developed in two different places aquatic and ground. Methods: This is a randomized clinical trial study, 42 patients with moderate to very severe DPOC were recruited for the study, mean age of 63,2 10,9 years old. Randomized in 3 groups: Control Group (CG), Land Group (LG) and Water Group (WG). The PE protocol was performed in a period of 8 weeks, with frequency of 3 times per week. The CG participated in an educational program. All the patients were assessed twice through spirometry, respiratory muscular strength, the 6-min walk test, the quality of life (SF-36 and SGRQ), the LCADL, the MRC, the BODE index and the upper limbs (UP) incremental test. Results: There was a significant difference after the approaches in DP6 from the WG (p=0,02); in VEF1 in LG (p=0,00) and WG (p=0,01); in MIP in LG (p=0,01) and WG (p=0,02); in MEP in LG (p=0,02) and WG (p=0,01); the MRC decreases in WG (p=0,00). there was an increase of the weight supported by the UP in LG (p=0,00) and WG (p=0,01). The LG showed an increase of the quality of life represented by the SGRQ total score (p=0,00). The BODE index decreased in LG (p=0,00) and WG (p=0,01). In LCDAL, the LG showed a decrease. Conclusion: This data in this present study suggest that both approaches of low intensity exercise showed to be beneficial in moderate to very severe COPD patients. The WG showed additional benefits in physical function, pointing to a new therapeutic modality for COPD patients
Resumo:
Introduction: The ability to walk is impaired in obese by anthropometric factors (BMI and height), musculoskeletal pain and level of inactivity. Little is known about the influence of body adiposity and the acute response of the cardiovascular system during whole the 6-minute walk test (6mWT). Objective: To evaluate the effect of anthropometric measures (BMI and WHR waist-to-hip ratio), the effort heart and inactivity in ability to walk the morbidly obese. Materials and Methods: a total 36 morbidly obese (36.23 + 11.82 years old, BMI 49.16 kg/m2) were recruited from outpatient department of treatment of obesity and bariatric surgery in University Hospital Onofre Lopes and anthropometric measurements of obesity (BMI and WHR), pulmonary function, pattern habitual physical activity (Baecke Questionnaire) and walking capacity (6mWT). The patient was checking to measure: heart rate (HR), breathing frequency (BF), peripheral oxygen saturation, level of perceived exertion, systemic arterial pressure and duplo-produto (DP), moreover the average speed development and total distance walking. The data were analysed between gender and pattern of body adiposity, measuring the behavior minute by minute of walking. The Pearson and Spearmam correlation coefficients were calculated, and stepwise multiple Regression examined the predictors of walking capacity. All analyses were performed en software Statistic 6.0. Results: 20 obese patients had abdominal adiposity (WHR = 1.01), waist circumference was 135.8 cm in women (25) and 139.8 cm in men (10). Walked to the end of 6mWT 412.43 m, with no differences between gender and adiposity. The total distance walked by obesity alone was explained by BMI (45%), HR in the sixth minute (43%), the Baecke (24%) and fatigue (-23%). 88.6% of obese (31) performed the test above 60% of maximal HR, while the peak HR achieved at 5-minute of 6mWT. Systemic arterial pressure and DP rised after walking, but with no differences between gender and adiposity. Conclusion: The walk of obese didn´t suffers influence of gender or the pattern of body adiposity. The final distance walked is attributed to excess body weight, stress heart, the feeling of effort required by physical activity and level of sedentary to obese. With a minute of walking, the obeses achieved a range of intensity cardiovascular trainning
Resumo:
The term fatigability concerns the degree of fatigue associated with performing an activity of any type (physical, mental, emotional and / or social). Recently scales for assessing fatigue in the English language were created, however, gaps exist regarding the validity of these scales in relation to oxygen consumption and levels of perceived fatigue. Objective: To investigate the validity of perceived fatigability scale in older women frail and non-frail by the expired gases kinetics. Methods: This is a study of type validation, where were evaluated 48 elderly. The evaluation was conducted at two different sessions. In the first, data were collected demographic partners, as well as assessment of cognitive function, physical health, and the phenotype of frailty. The second was composed by the test 6-minute walk (6MWT) associated the expired gases kinects and assessment of perceived fatigability. Statistical analysis was performed a descriptive analysis and then we used the Pearson correlation test to evaluate the relationship between the measure of perceived fatigue and variables oxygen consumption (VO2), carbon dioxide production (VCO2), respiratory exchange ratio (RER)before and after 6MWT. We used a linear regression model initially considering the following explanatory variable: age, Body Mass Index (BMI), presence of frailty, comorbidities, level of physical activity, distance covered in the 6MWT , the energy cost of walking and severity of fatigability on performance. Results: The final sample consisted of 44 elderly women, 4 elderly were excluded because they didn t complete all phases of this study. The mean age obtained was 75 years (± 7.2 years). There was no significant correlation between fatigability measures and the values of VO2 ( r = .09 , p = .56 ) , VCO2 ( r = .173 , p = .26 ) , RER ( r = - .121 , p = .43 ). The final linear regression model showed that the energy cost of walking, the usual level of physical activity and the performance severity of fatigability explained 83.5 % (R2 = 0.835, p < 0.01) of the variation in the perceived fatigability. Conclusion: Our findings indicate a relationship between greater severity of fatigability and lower levels of physical activity and increased energy cost in walking, suggesting that the fatigability analyses using a simple numeric scale is valid and viable for assessment of fatigue in older women
Resumo:
During the last decades, it has been established that there is a relationship between major depression and activation of immune system. Nociceptin/orphanin FQ (N/OFQ) is the natural ligand of a Gi-protein coupled receptor named NOP, both compose the peptidergic system wich is involved in the regulation of mood states and inflammatory responses. Considering these actions, the present thesis aimed to investigate the consequences of blocking NOP signaling in lipopolysaccharide (LPS)-induced sickness and depressive-like behaviors in mice. Systemic administration of LPS doses, that do not cause sepsis in mice, induce changes in their behaviors related with activity of pro-inflammatory cytokines tumor necrosis factor-α (TNF-α) and interleukins 6 (IL-6) and 1β (IL-1 β). At the time points of 2 to 6 h and 24 h after intraperitoneal injection, mice treated with LPS displayed, respectively, sickness and depressive-like behaviors. In the present work the administration of LPS 0.8 mg/kg (ip) significantly induced sickness signs in Swiss and CD-1 mice, such as weight loss, transient reduction in rectal temperature and decrease of food and water intake. Moreover at 24 h after LPS injection these same mice strains displayed significantly increased immobility time on the tail suspension test (TST) when compared with control mice, this alteration was not related with possible locomotion impairments as verified on the open field test. Treatment with Nortriptyline 30 mg/kg (ip, 60 min prior the TST) reduced the immobility time of control and LPS-treated mice and was used as standard antidepressant. The NOP receptor antagonist SB-612111 (10 mg/kg, ip), 30 min prior LPS, did not modify LPS-induced sickness signs and depressive-like behavior. However, when injected 24 h after LPS treatment, SB-612111 (ip, 30 min prior the TST) as well as the peptidergic NOP receptor antagonist UFP-101 (10 nmol/2μL, icv, 5 min prior the TST) significantly reversed the toxin effects. The protocol of LPS-induced depressive-like states was also tested in NOP receptor knockout mice (NOP(-/-)) and their respective wild types (NOP(+/+)). LPS evoked transient rectal temperature reduction in NOP(-/-) mice and loss of body weight, food and water intake reduction in both NOP(+/+) and NOP(-/-) mice. The consumption of water was significantly different due to the genotype. LPS injection induced transient changes in pro-inflammatory cytokines. At 6 h after LPS injection, serum levels of TNF-α were significantly increased in NOP(+/+) and NOP(-/-) mice, as the IL-6 levels were significantly increased just in NOP(+/+) serum. At 24 h after LPS treatment the pro-inflammatory cytokines had returned to the baseline levels in both genotypes. LPS treatment elicited depressive-like effects in NOP(+/+) but not in NOP(-/-) mice. The data obtained during the execution of this doctoral thesis reveal that pharmacological and genetic blockade of NOP signaling does not affect LPS evoked sickness signs while reversing depressive-like behavior. In conclusion, these results highlight the involvement of the peptidergic system N/OFQ - NOP receptor in the modulation of behaviors related to mood and activation of the immune system.
Resumo:
Backgroud: Obesity is a major public health problem and is related to the low physical capacity when obese are compared to no-obese people, however the cause of this limitation is not completely understood. The measurement associated of physiological response to the telemetric 6MWT adds information of metabolic and respiratory system for diagnose of the functional limitation. Objective: Analyze physiological, metabolic and ventilatory responses in women with different body fat during the 6MWT. Methods: 32 women (8 non-obese, 8 Overweight, 8 Obese and 8 morbidly obese) were evaluated for anthropometry, lung function and exercise capacity. Results: Morbidly obese walked the shortest distance (400.2±38.7m), had lower VO2/Kg (12.75±3.20l/Kg/min) and lower R (0.74± 0.11) in the 6MWT compared to other groups. Analyses of metabolic (VO2 and VCO2) and respiratory (VE, VT and BF) during the test did not identify differences between groups. The evaluation of cardiac function (O2 pulse) found higher values in the OM (12.3 ± 4.9ml/bat). Conclusion: The OM had worse performance in the 6MWT compared to other groups. The physical performance may be reduced in this population related to a protocol-dependent response because the speed of 6MWT is self-adjusted allows the individual himself select the intensity of the test, making it set at a speed where there is energy saving
Resumo:
The system built to characterize electrodes and, consequently, deposited fine films are constituted by a hollow cathode that works to discharges and low pressures (approximately 10-3 to 5 mbar), a source DC (0 to 1200 V), a cylindrical camera of closed borossilicato for flanges of stainless steel with an association of vacuum bombs mechanical and spread. In the upper flange it is connected the system of hollow cathode, which possesses an entrance of gas and two entrances for its refrigeration, the same is electrically isolated of the rest of the equipment and it is polarized negatively. In front of the system of hollow cathode there is a movable sample in stainless steel with possibility of moving in the horizontal and vertical. In the vertical, the sample can vary its distance between 0 and 70 mm and, in the horizontal, can leave completely from the front of the hollow cathode. The sample and also the cathode hollow are equipped with cromel-alumel termopares with simultaneous reading of the temperatures during the time of treatment. In this work copper electrodes, bronze, titanium, iron, stainless steel, powder of titanium, powder of titanium and silício, glass and ceramic were used. The electrodes were investigated relating their geometry change and behavior of the plasma of the cavity of hollow cathode and channel of the gas. As the cavity of hollow cathode, the analyzed aspects were the diameter and depth. With the channel of the gas, we verified the diameter. In the two situations, we investigated parameters as flow of the gas, pressure, current and applied tension in the electrode, temperature, loss of mass of the electrode with relationship at the time of use. The flow of gas investigated in the electrodes it was fastened in a work strip from 15 to 6 sccm, the constant pressure of work was among 2.7 to 8 x 10-2 mbar. The applied current was among a strip of work from 0,8 to 0,4 A, and their respective tensions were in a strip from 400 to 220 V. Fixing the value of the current, it was possible to lift the curve of the behavior of the tension with the time of use. That curves esteem in that time of use of the electrode to its efficiency is maximum. The temperatures of the electrodes were in the dependence of that curves showing a maximum temperature when the tension was maximum, yet the measured temperatures in the samples showed to be sensitive the variation of the temperature in the electrodes. An accompaniment of the loss of mass of the electrode relating to its time of use showed that the electrodes that appeared the spherical cavities lost more mass in comparison with the electrodes in that didn't appear. That phenomenon is only seen for pressures of 10-2 mbar, in these conditions a plasma column is formed inside of the channel of the gas and in certain points it is concentrated in form of spheres. Those spherical cavities develop inside of the channel of the gas spreading during the whole extension of the channel of the gas. The used electrodes were cut after they could not be more used, however among those electrodes, films that were deposited in alternate times and the electrodes that were used to deposit films in same times, those films were deposited in the glass substrata, alumina, stainless steel 420, stainless steel 316, silício and steel M2. As the eletros used to deposit films in alternate time as the ones that they were used to deposit in same times, the behavior of the thickness of the film obeyed the curve of the tension with relationship the time of use of the electrode, that is, when the tension was maximum, the thickness of the film was also maximum and when the tension was minimum, the thickness was minimum and in the case where the value of the tension was constant, the thickness of the film tends to be constant. The fine films that were produced they had applications with nano stick, bio-compatibility, cellular growth, inhibition of bacterias, cut tool, metallic leagues, brasagem, pineapple fiber and ornamental. In those films it was investigated the thickness, the adherence and the uniformity characterized by sweeping electronic microscopy. Another technique developed to assist the production and characterization of the films produced in that work was the caloteste. It uses a sphere and abrasive to mark the sample with a cap impression, with that cap form it is possible to calculate the thickness of the film. Through the time of life of the cathode, it was possible to evaluate the rate of waste of its material for the different work conditions. Values of waste rate up to 3,2 x 10-6 g/s were verified. For a distance of the substratum of 11 mm, the deposited film was limited to a circular area of 22 mm diameter mm for high pressures and a circular area of 75 mm for pressure strip. The obtained films presented thickness around 2,1 µm, showing that the discharge of arch of hollow cathode in argon obeys a curve characteristic of the tension with the time of life of the eletrodo. The deposition rate obtained in this system it is of approximately 0,18 µm/min
Resumo:
INTRODUCTION: Cardiac and pulmonary manifestations of the Chagas disease (CD) affect between 20-30% of the infected subjects. The chronic Chagas cardiomyopathy (CCC) has some peculiarities such as arrhythmias and, especially heart failure (HF) and is potentially lethal due to left ventricular dysfunction. How respiratory disorders, patients get progressive loss of functional capacity, which contributes to a poor quality of life related to disease. Measurements of lung volume by the movement of the chest wall surface are an alternative evaluation of lung function and kinematics of complex thoracoabdominal for these patients. OBJECTIVE: evaluate the kinematics of the thoracoabdominal complex through the regional pulmonary volumes and to correlate with functional evaluation of the cardiorrespiratory system in patients with Chagas disease at rest. MATERIALS AND METHODS: a cross-section study with 42 subjects had been divided in 3 groups, 15 composed for patients with CCC, 12 patients with HF of different etiologies and 15 healthful presented control group. An optoelectronic plethysmography (POE), Minnesota questionnaire, six minute walk test, spirometer and manovacuometer was used. RESULTS: It was observed in the 6MWT where group CRL presented greater distance 464,93±44,63m versus Group HF with 399,58± 32,1m (p=0,005) and group CCC 404±68,24m (p=0,015), both the groups presented difference statistics with regard to Group CRL. In the manovacuometer 54,59±19,98; of the group CCC and 42,11±13,52 of group IC found group CRL presented 81,31±15,25 of the predicted versus, presenting in relation to group CRL. In the POE it observed a major contribution in abdominal compartment in patients with IC if compared like CCC and control groups. On the basis of the questionnaire of quality of life of Minessota, verified a low one groups CCC and IC 43,2±15,2 and 44,4±13,1, respectively (p<0,05) when compared with the control group (19,6±17,31). CONCLUSION: it seems that the patients with CCC possess same functional and respiratory characteristics, observed for the POE, 6MWT, manovacuometer and spirometer to the patients of group HF, being able to consider similar interventions for this complementary group as therapeutical of this neglected disease
Resumo:
Pulmonary Rehabilitation, especially due to aerobic exercise, positive impact in reducing morbidity/mortality of patients with COPD, however the economic impact with costs of implementing simple programs of aerobic exercise are scarce. This is a blind randomized clinical trials, which aimed to evaluate the costs and benefits of a simple program of aerobic exercise in individuals with COPD, considering the financial costs of the Public Health System and its secondary endpoints. We evaluated lung function, the distance walked during six minutes of walking, the respiratory and peripheral muscle strength, quality of life related to health (QLRH), body composition and level of activity of daily living (ADL) before and after eight weeks of an aerobic exercise program consisting of educational guidance for both groups, control and intervention and supervised walks to the intervention group. The health costs generated in both groups were calculated following table Brazilian Public Health System. The sample consisted of forty patients, two being excluded in the initial phase of desaturation during the walk test six minutes. Were randomized into control and intervention group thirty-eight patients, three were excluded from the control group and one was excluded from the intervention group. At the end, thirty-four COPD comprised the sample, 16 in the control group and 18 in the intervention group (FEV1: 50.9 ± 14% pred and FEV1: 56 ± 0.5% pred, respectively). After for intervention, the intervention group showed improvement in meters walked, the sensation of dyspnea and fatigue at work, BODE index (p <0.01) in QLRH, ADL level (p <0.001) as well as increased strength lower limbs (p <0.05). The final cost of the program for the intervention group was R $ 148.75, including: assessments, hiking supervised by a physiotherapist and reassessments. No patient had exacerbation of IG, while 2 patients in the CG exacerbated, generating an average individual cost of R $ 689.15. The aerobic exercises in the form of walking showed significant clinical benefits and economic feasibility of its implementation, due to low cost and easy accessibility for patients, allowing them to add their daily practice of aerobic exercises
Resumo:
obesity affects rightly functional capacity diminishing the cardiovascular system efficiency and oxygen uptake (VO2). Field tests, such as, Incremental Shuttle Walking Test (ISWT) and Six Minute Walk Test (6MWT) has been employed as alternative of Cardiopulmonary Exercise Test (CPX), to functional assessing for conditions which transport of oxygen to peripheral is diminished. Nevertheless, the knowing about metabolic variables response in real time and it comparing among different maximal and submaximal tests in obese is absent. Aim: to compare cardiopulmonary, metabolic response during CPX, ISWT and 6MWT and to analyse it influence of adiposity markers in obese. Material e Method: crosssectional, prospective study. Obese included if: (BMI>30Kg/m2; FVC>80%), were assessed as clinical, anthropometric (BMI, body adiposity index-BAI, waist-WC, hip- HC and neck-NC circumferences) and spirometry (forced vital capacity-FVC, Forced expiratory volume-1°second-FEV1, maximal voluntary ventilation-MVV) variables. Obese performed the sequence of tests: CPX, ISWT and 6MWT. Throughout tests was assessed breath-by-breath by telemetry system (Cortex-Biophysik-Metamax3B) variables; oxygen uptake on peak of activity (VO2peak); carbon dioxide production (VCO2); Volume Expiratory (VE); ventilatory equivalents for VO2 (VE/VO2) and CO2 (VE/VCO2); respiratory exchange rate (RER) and perceived effort-Borg6-20). Results: 15 obese (10women) 39.4+10.1years, normal spirometry (%CVF=93.7+9.7) finished all test. They have BMI (43.5+6.6kg/m2) and different as %adiposity (BAI=50.0+10.5% and 48.8+16.9% respectively women and men). Difference of VO2ml/kg/min and %VO2 were finding between CPX (18.6+4.0) and 6MWT (13.2+2.5) but not between ISWT (15.4+2.9). Agreement was found for ISWT and CPX on VO2Peak (3.2ml/kg/min; 95%; IC-3.0 9.4) and %VO2 (16.4%). VCO2(l/min) confirms similarity in production for CPX (2.3+1.0) and ISWT (1.7+0.7) and difference for 6MWT (1.4+0.6). WC explains more the response of CPX and ISWT than other adiposity markers. Adiposity diminishes 3.2% duration of CPX. Conclusion: ISWT promotes similar metabolic and cardiovascular response than CPX in obese. It suggesting that ISWT could be useful and reliable to assess oxygen uptake and functional capacity in obese