3 resultados para Órteses

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this paper is to identify the utilization of two models of orthotics used in the conservative treatment of rizartrose in patients/consumers that were referred by the medical clinic to the LAI (Laboratory of Integrated Accessibility). It describes this group s perception related to the functional aspects of the two models, evaluates the value of the product attributed by the patient/consumer and describes the importance attributed to each model. The research s objective consists in identifying which model this is preferred from the point of view by the patients that use either the dorsal or ventral models used in the conservative treatment of rizartrose . This work is then based on the exploratory research through the investigation of the bibliography available and in the research field. The research field used the case study methodology to investigate the phenomenon in the real context. The data were collected using a patient questionnaire during two times after the use of the dorsal orthotic and after the use of the ventral orthotic. The questionnaire was used to identify the relationship between the patients/consumers and the two different types of orthotics. A general descriptive analysis was used in order to verify the patient s abilities executing certain activities daily living using the dorsal and ventral orthotics, the product s functional aspects and its value from the patient s/consumer s point of view. The results show that the preference for the dorsal or ventral models is determined by the individual needs of each person. The results also show that other variables, such as the use of the orthotic on the dominant or non-dominant hand, play a role in the preferred model by the patient/consumer and need to be further investigated

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this work is to critically analyze the seated mobility adaptive equipment, wheelchair, used by non-ambulatory children/adolescents diagnosed with cerebral palsy of the quadriplegy type with ages in between 0-18 years old in the municipal city of Natal/RN and of other ones in the state of Rio Grande do Norte. This study is characterized as descriptive as it took into consideration the individualized conditions of each child/adolescent and of their home environment, and also evaluates the condition of the used seated mobility devices such as wheelchairs or strollers. Thirty three (33) subjects which had a wheelchair prescribed by a healthcare professional specialist in adaptive equipment within the past 3 years were selected. A questionnaire was applied through a phone with the patient s primary care giver or parents. The results obtained showed that all the equipment being used had an anatomical seat and back and the tilt system mechanism and even though most of the patients required small individual adjustments upon receiving the wheelchair in order to accommodate to the patients characteristics. From the point of view of the caregiver/parents interviewed, 97% described satisfied with the equipment and report assistance with mobility (97%), comfort (82%) and good posture (82%) as the main positive aspects from the equipment. The results also describe the aspects related to the maintenance, time used and activities developed that were reported by the patients. The conclusion therefore is that in order to select the equipment to meet the needs of the consumer it is necessary that: an appropriate wheelchair prescription takes place, the up-to-date knowledge of equipment available in the market, the appropriate use of the resources from the concession programs of the government that purchase equipment and the establishment of link in between the manufacturers, patients and the caregivers

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Atualmente com o crescente aumento de dispositivos robóticos destinados para aplicação na área de mobilidade de pessoas que sofreram algum tipo de lesão medular, se faz necessário desenvolver novas ferramentas para tornar tais equipamentos mais adaptáveis, seguros e autônomos. Para que as órteses robóticas que auxiliam na locomoção de pessoas paraplégicas possam desempenhar sua função, estas devem ser capazes de reproduzir os movimentos perdidos com o máximo de fidelidade e segurança em ambientes que eventualmente possam conter obstáculos de diferentes tipos como buracos, escadas e calçadas. As órteses robóticas para membros inferiores têm a capacidade de caminhar, subir e descer degraus, todavia, esses movimentos, na maioria das vezes, não se adaptam ao ambiente, sendo assim, para uma órtese robótica que foi projetada para subir um degrau com uma determinada altura ao se deparar com um degrau maior provavelmente não conseguirá realizar essa tarefa com a mesma segurança. Para solucionar esse e outros problemas, esse trabalho apresenta um Sistema de Auxílio à Locomoção (SAL) dotado de um planejador de passos e um gerador de referências angulares com características antropomórficas para a órtese robótica Ortholeg. O SAL utiliza dados antropométricos do usuário para gerar um padrão de marcha personalizado, dessa forma, a órtese em questão é capaz de adaptar o tamanho do passo para não colidir com obstáculos presentes no ambiente e transpor buracos com diversos tamanhos, subir e descer escadas e calçadas com diferentes valores de altura e comprimento. Para desenvolver o sistema de auxílio à locomoção foram adaptadas técnicas de planejamento de caminho, usadas a princípio em robôs bípedes. São apresentados vários experimentos que mostram a órtese Ortholeg realizando alguns movimentos com características antropomórficas para diferentes distâncias de caminhada e três tipos de obstáculos: degrau, buraco e calçada. A autonomia adquirida com a utilização do sistema de planejamento apresentado facilita a utilização de órteses robóticas como também garante uma maior segurança ao usuário.