127 resultados para desempenho pós-plantio
Resumo:
The chart of control of Hotelling T2 has been the main statistical device used in monitoring multivariate processes. Currently the technological development of control systems and automation enabled a high rate of collection of information of the production systems in very short time intervals, causing a dependency between the results of observations. This phenomenon known as auto correlation causes in the statistical control of the multivariate processes a high rate of false alarms, prejudicing in the chart performance. This entails the violation of the assumption of independence and normality of the distribution. In this thesis we considered not only the correlation between two variables, but also the dependence between observations of the same variable, that is, auto correlation. It was studied by simulation, the bi variate case and the effect of auto correlation on the performance of the T2 chart of Hotelling.
Resumo:
The seismic reflection is used on a large scale in oil exploration. In case of marine acquisition the presence of high impedance contrast at the interfaces water/air generates multiple reflections events. Such multiple events can mask primary events; thus from the interpretational viewpoint it is necessary to mitigate the multiples. In this manuscript we compare two methods of multiple attenuation: the predictive multichannel deconvolution (DPM) and the F-K filtering (FKF). DPM is based in the periodicity of the multiples while FKF is based in multiples and primaries splitting in F-K domain. DPM and FKF were applied in common-offset and CDP gathers, respectively. DPM is quite sensible to the correct identification of the period and size of the filter while FKF is quite sensible to an adequate choice of the velocity in order to split multiples and primaries events in the F-K domain. DPM is a method that is designed to act over a specific event. So, when the parameters are well selected, DPM is very efficient in removing the specified multiple. Then DPM can be optimized by applying it several times, each time with a different parameterization. A deficiency of DPM occurs when a multiple is superposed to a primary event: in this situation, DPM can attenuate also the primary event. On the other hand, FKF presents almost the same performance to all multiples that are localized in the same sector of the F-K domain. The two methods can be combined in order to take advantage of their associated potentials. In this situation, DPM is firstly applied, with a focus in the sea bed multiples. Then FKF is applied in order to attenuate the remaining multiples
Resumo:
This paper prese nts the validation of the Performance Indicator System for Projects under Construction - SIDECC. The goal was to develop a system of performance indicators from the macroergonômica approach, con sidering criteria of usefulness , practicality and applicabilit y and the concept of continuous improveme nt in the construction industry . The validation process SIDECC consisted of three disti nct models . Modeling I corresponded to the theoretical development and valid ation of a system of indicators . Modeling II concern s the development and valida tion of multi - indicator system . For this modeling, we used the Mother of Use and Importance and Multivariate Analysis . Modeling III correspo nded to the validation situated , which consisted of a case study of a wo rk of construct ion of buildings , which were applied and anal yzed the results of modeling II . This work resulted in the development of an applied and tested for the construction of an integrated system of per formance indicators methodology , involving aspects of production , quality , e nvironmental, health and safety . It is inferred that the SIDECC can be applied, in full or in part , the construction companies as a whole, as we ll as in other economic sectors .
Resumo:
In recent years, as part of the expansion process of its activities, the Instituto Federal de Educação, Ciência e Tecnologia do Rio Grande do Norte – IFRN (Federal Institute for Education, Science and Technology of the State of Rio Grande do Norte – IFRN) detected the need to hire more employees for the institution. This expansion process, a policy of the Federal Government, together with the increase of human resources, required the construction of an adequate facility in the municipality of São Gonçalo do Amarante-RN, for training and qualification and as a means of better enabling its personnel. Along with this policy, the Federal Government is also deeply concerned that its buildings be environmentally friendly. This study deals with this subject matter, as it develops an architectural design of a public building with an emphasis upon the reduction of energy consumption, through the study of energy performance factors such as defined by Carneiro (1988) and adapted by the author of the present study. It is known that residential, commercial and public buildings represent about 45 % of energy consumption in Brazil. That is why it is necessary to consider the reduction of such consumption in buildings, as well as the role that professionals, especially architects, play in this issue. The most effective participation in this regard in the field of architecture occurs in the design phase. However, the architectural solution proposed here goes beyond the energy performance factors, since it also involves other aspects, such as the definition of the concept, the parti and the spatial solution itself. In this sense, the architectural project of the Centro de Treinamento dos Servidores do IFRN - CTSIFRN (Training Center for IFRN Personnel – CTSFIRN) is particularly fitting as a subject for research at the Professional Master Program at PPGAU/UFRN, which is devoted to research on architecture, design and the environment.
Resumo:
This work describes the design process of a small recreational gated community in Pium, Nísia Floresta/RN, from concept to final design stages, with emphasis on low environmental impact, thermal comfort and the spatial quality of housing. The process consisted in a review of the literature and relevant standards, studies of design references and architectural programming. The project development was initially focused on the project’s feasibility, with the definition of the number of units, implantation, size and location of the dwellings and the common areas of the development. Two types of houses (four low rise and five duplex units) have been proposed in order to attend the premises of architectural programming. The conception of the architectural design began with the rooms’ zoning according to the lots. This resulted in the pre-selection of three alternatives that were evaluated in terms of spatial quality and environmental performance. The development of sketches focused on the envelope consistent with the bioclimatic guidelines and on the language of the compatible proposal with the lowest possible environmental impact of the building system, which resulted in the selection of the eucalyptus wood type. During the working drawings, the Quality Technical Regulation for the Level of Energy Efficiency Residential Buildings (RTQ -R) was adopted for the evaluation of the envelope, which resulted in "B" level of efficiency for the first case. After minor adjustments, mainly in frames, the efficiency level rose to "A", demonstrating that early project decisions contributed to the envelope energy performance. Besides the design of the two types of units, the final proposal of the gated community includes the design of the equipment for the common areas (entrance, multipurpose room and support and service sector), and the descriptive texts explaining the project and construction’s details.
Resumo:
Objetivo: Investigar os efeitos imediatos do Kinesio Taping® no desempenho neuromuscular do Quadríceps Femoral (QF) de indivíduos submetidos à reconstrução do Ligamento Cruzado Anterior (LCA). Metodologia: trata-se de um ensaio clínico e randomizado composto por 45 indivíduos do sexo masculino que se encontravam entre 12ª e 17ª semanas após reconstrução do LCA. Todos foram submetidos a uma avaliação inicial composta pela análise do equilíbrio postural, através da baropodometria; determinação do Senso de Posição Articular (SPA), seguidas das avaliações isocinéticas excêntricas e concêntricas a 600/s, concomitante com a captação do sinal eletromiográfico do músculo Vasto Lateral (VL). Posteriormente foram alocados de forma aleatória em Grupo Controle (GC), Grupo Placebo (GP) e Grupo Experimental (GE). Os indivíduos do GE foram submetidos ao protocolo sugerido (aplicação do Kinesio Taping® no QF do membro acometido), enquanto os do GP utilizaram a aplicação do Kinesio Taping® sem as recomendações propostas pelo método. Já os indivíduos do GC permaneceram em repouso por dez minutos, sendo todos os indivíduos submetidos a uma reavaliação de forma idêntica à primeira. Foram analisadas as seguintes variáveis: pico de torque médio, pico de torque/peso corporal, potência muscular e erro absoluto do SPA para a dinamometria; amplitude ântero-posterior e médio-lateral para a baropodometria; e a amplitude de ativação muscular (Root Means Square - RMS) por meio da eletromiografia de superfície. Resultados: Nenhuma das variáveis analisadas apresentou diferenças intergrupo ou intragrupo. Conclusão: O Kinesio Taping® não altera o desempenho neuromuscular do quadríceps femoral de indivíduos submetidos à reconstrução do LCA para nenhuma das variáveis analisadas.
Resumo:
The presence of peripheral arterial disease (PAD) increases the risk and vulnerability to adverse clinical outcomes in the elderly. Like this, we investigated the relationship between functional performance and indicators of PAD in elderly women. METHODS: Cross-sectional study in which 54 elderly were assessed by questionnaire mini mental state examination, Short Phisical Performance Battery (SPPB), ankle-brachial index (ABI), human activity profile (HAP) and Edinburgh questionnaire. Statistical analysis was performed using ANOVA, t test and Pearson correlation. We considered p <0.05 as significance level. RESULTS: The mean age SPPB and ABI were 69.2 (± 6.9) years, SPPB 9.42 (± 2.55) and ABI 1.04 (± 0.14). The prevalence of PAD was 16.3%. There was a significant correlation between ABI and gait speed (r = 0.75, p = 0.001) and between PAH with SPPB (p = 0.001). CONCLUSIONS: It is suggested that the decline in functional performance in older, expressed in gait velocity component of the SPPB, is related to the presence of PAD