116 resultados para Válvulas - Hidráulica


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the state of Rio Grande do Norte (RN), Brazil, there are about 80 sewage treatment systems being the predominant technology waste stabilization ponds. The Baldo s WWTP , due to its location and low availability of area, was designed as a hybrid conventional system (UASB reactor followed by activated sludge with biodiscs) at a tertiary level, being the most advanced WWTP in the State and also with the larger treatment capacity (1620 m3/h) .The paper presents the results of its performance based on samples collections from May to December 2012. Composite samples of the effluent of the grit chamber, UASB reactors, anoxic chambers, aeration tanks and treated effluent were collected weekly, every 4 hours for 24 hours. The results showed that the WWTP effluent presented adequate ranges of temperatures, pH and DO, however removal efficiencies of BOD and TSS were below the predicted by design. The UASB reactors also showed removals of BOD and TSS less than expected, due to the accumulation of sludge in the reactors, which eventually, was washed out in the effluent. The nitrification process was not satisfactory mainly due to problems in the oxygen distribution in the aeration tanks. The removal of ammonia and TKN were high, probably by the assimilation process

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study is to characterize and evaluate the Macro System of Regional Water Distribution Natal North (RNN) and Southern Regional Natal (RNS), covering 35% and 65% respectively of the Natal-RN City. The terms of the quality and quantity of water (surface and groundwater) were also evaluated in order to adjust the parameters that contribute to proper distribution and control in water reserves. The methodology of the work took place from collecting volumetric data of production capacity and distribution of the two treatment plants for Regional as well as the flow rates of wells. Yet the quantitative capacity of reservation, distribution and consumption of the main reservoirs, population numbers and consumption of members neighborhoods were collected. Data were tabulated and used in computational simulator EPANET to diagnose possible through the water balance, the offers and demands on the water supply system in the neighborhoods of the capital, linking them to specific distribution points. We also evaluated the wells in the levels of nitrate in water consumed. As a result it was found that some neighborhoods in the South Regional Natal, was ranked as critical supply situation: City of Hope, Lagoa Nova and Nova Descoberta, where demand exceeds supply. While in most Northern Regional Natal present deficiency in the supply system as: Lagoa Azul, the Parque dos Coqueiros, igapó, Amarante and Salinas. The rates of nitrate in the city were significant, but manageable with corrective and preventive measures. The averages were 12 mg /l-N in Candelária, 10 mg/l-N in Lagoa Nova, 9 mg/l-N in Satelite, 20 mg/l-N in Gramore and 15 mg/l-N in N. Sra. Apresentação. Therefore proper distribution of water abstracted and implementation of quality control ensures the supply required by the system, associated with preservation of Water Resources of the Metropolitan Region of Natal

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aquatic ecosystems can play a role as carbon-dioxide-source or carbon-dioxide-sink systems due to the high predominance of heterotrophic or autotrophic metabolism. The primary production can strongly affect the carbon balance (CO2) through the consumption of carbon dioxide in the photosynthesis, especially in eutrophic environment, acting as a carbon sink. The present study tested the hypothesis that the eutrophic reservoirs in tropical semi-arid region are carbon dioxide-sink systems due to the high primary productivity presented in these systems. Five Brazilian reservoirs from the semi-arid in the northeast region were monitored monthly during four years (2010 to 2013) with a prolonged drought event identified during the study. The results showed an increasing level of eutrophication over the period of prolonged drought, with the predominance of autotrophy. Significant negative correlations were observed between the partial pressure of CO2 (pCO2) (p<0,001) and chlorophyll-a in the Boqueirão, Passagem das Traíras, Dourado and Gargalheiras reservoirs, showing a pattern of the carbon dioxide-sink systems. However, this pattern was not found in Cruzeta reservoir. In summary, in the tropical semi-arid region, hydrological and morphometric variables can lead to different behaviors of the water-supply reservoirs on the carbon metabolism. The eutrophic reservoirs evaluated showed a negative relationship between pCO2 and Chl-a, which suggests that these water bodies show an autotrophic metabolism and behave as carbon dioxide- sink systems

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Waste stabilization ponds are the main technology in use for domestic sewage treatment in Rio Grande do Norte State (RN), northeast Brazil. The are around 80 systems, constructed mainly by municipal city halls, being series comprised by a primary facultative pond followed by two maturation ponds the most used configuration. Due to problems related with the production and destination of sludge and generation of bad odors, the designers have avoided the use of anaerobic lagoons. The majority of systems are rarely monitored to verify their efficiencies and to get new project parameters for future designing. This work has as purpose to make a diagnosis of efficiency of three series of waste stabilization pond series (WSPS) of Jardim Lola 1, Jardim Lola 2 and Beira Rio, located in the North Zone of the city of the Natal/RN, treating domestic raw sewage, on the removal of organic matter and thermotolerant coliform, comparing the operational conditions of the systems this inside of the bands foreseen in the project, through parameters BOD5, QOD, thermotolerant coliforms, dissolved oxygen, pH, temperature, ammoniac nitrogen, total and suspended solids. The work was carried through in the WSPS, all constituted by a primary facultative pond followed by two maturation ponds. Socioeconomic characteristics of population are predominantly low and all the plants are very near of the contributing basins. The series were monitored from of May the November of 2002, totalizing 20 collections of grab samples of raw sewage and ponds effluents between 8:00 and 9:50 h. The main aspect to be detached by the results was the great concentration of organic matter (BOD and COD) and microorganisms the raw sewage which were around two times more concentrated than those values foreseen one in project. Considering all series the highest removals of organic matter were observed in system Beira Rio (84 and 78% of BOD and COD, respectively), which presented high hydraulic detention time (TDH = 89 days). On the other hand, Jardim Lola 1 and Jardim Lola 2 presented a much lower values of HDT (36 days and 18 days respectively) and their removals of BOD and COD were the same (76% and 60%, respectively). The Beira Rio WSPS, was the most efficient verified in relation to solids and ammonia, proving the great influence of the operational variables such as HDT and applied surface organic loadings on the performance of pond series. Although the treatment plants have reached efficiencies of thermotolerant coliforms around 99,999%, the concentrations in the final effluent can be considered very high for launching in aquatic bodies, particularly those produced by Jardim Lola 1 and Jardim Lola 2 series

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In Natal/RN, 68% of the population uses some kind of individual system for their domestic sewers treatment, being that the most used it is septic tank, followed by sumidouro. Every treatment system of sewers, usually used, generates a by-product denominated sludge. That residue presents some components, in its constitution, undesirable under the environmental and sanitary point of view. In such case, to assure that the system treatment has satisfactory results, it is necessary to do the adjusted disposition of the sludge sewage. Several countries are looking for technical alternatives for the use and disposition of residues. Under technical and environmental conditions appropriate, these materials can be used, decreasing the consumption of the natural resources and the treatment need, storage or elimination of the wastes, what decrease the risks created. Some of the alternatives of recycling of the sludge sewage are: the application in the agriculture, in the production of energy and as raw material in the civil construction. This study evaluated asphalt mixtures behavior that partially substituted conventional aggregates by septic tank sludge. The septic tank sludge gave origin to two raw materials called raw sludge and sludge ash. The raw sludge was put as a small aggregate and the sludge ash as filler. In the first experiment it was made a comparison between the mixture with conventional aggregates and the mixtures that replaced sand by raw sludge in the proportions from 5% to 40%. In the second experiment, it was made comparison between mixtures with 1%, 2% and 3% of sludge ash and cement. The stages developed along the study were: physical characterization of the conventional materials; physical, chemistry, thermal, mineralogical characterizations and analysis of environmental risk of the raw sludge; physical characterization and analysis of environmental risk of the sludge ash; analysis of the mixtures performance through its volumetric and mechanical characteristics; forecast of the mixtures susceptibility in the moisture presence. For the grain size composition used and with the percentage asphalt adopted, the mixtures with up to 7,5% of raw sludge in his composition attend to the National Department of Transports Infrastructure (DNIT) specifications. However, in agreement with the mixtures susceptibility in the moisture presence, the mixtures with addition of raw sludge don't present satisfactory acting. In such case, they could be used in arid and semi-arid areas. The raw sludge application in mixtures increased their voids volume and their stability. However, it damaged mixtures adhesiveness. Mixtures with sludge ash and with cement presented similar behavior. However, mixtures with sludge ash presented a better performance than mixtures with cement as for their stability and their tensile strength ratio. The mixture with 1% of sludge ash is better. The wastes studied don't represent environmental risk

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Piranhas-Açu basin is a Federal watershed with a drainage area of 43.681,5 km2, sited at Brazilian northeast semi arid, with 60% of your area in Paraiba State and 40% in Rio Grande do Norte State. The main river, Piranhas-Açu, has strategic importance for development of these states, because it s an essential source for many socio-economics activities developed along watercourse. The river s reach between Coremas-Mãe D`água Dam and Armando Ribeiro Gonçalves Dam has many irrigation projects, and supply many riverside cities. All this activities practiced in this river s reach consumes high water volumes. Due the importance of this stream and the necessity of an adequate management, this work aims for an impartial and detailed evaluation of real water supply conditions in this river s reach, by the application of hydrological modeling, including the arrangement of main dams in tributaries, and storage reservoir water balance. The rainfall-discharge model s applied in each sub-basins it was selected the model MODHISA- Hydrological Model of Semi Arid, that is a concentrated model with easy application. The simulation produced 50 years of inflows into the reservoirs, for which, were constructed the guaranties curves; and produced 50 years of synthetic discharge data in relevant points on the river and on its affluents; so it was constructed the permanence curves. Confronting the available discharge with the current and futures volumes of raw water captured in this river s reach, it was verified that de demands have high guaranties. This work concluded that the MODHISA Model is suitable to reproduce the hydrologic characteristics of Piranhas-Açu sub-basins, and showing good results

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This dissertation presents a methodology to the optimization of a predial system of cold water distribution. It s about a study of a case applied to the Tropical Buzios Residential Condominium, located in the Búzio s Beach, Nísia Floresta city, the east coast of the Rio Grande do Norte state, twenty kilometers far from Natal. The design of cold water distribution networks according to Norm NBR 5626 of the ABNT - Brazilian Association of Techniques Norms, does not guarantee that the joined solution is the optimal solution of less cost. It s necessary the use of an optimization methodology, that supplies us, between all the possible solutions, the minimum cost solution. In the optimization process of the predial system of water distribution of the Tropical Búzios Condominium, is used Method Granados, that is an iterative algorithm of optimization, based on the Dynamic Programming, that supplies the minimum cost s network, in function of the piezometric quota of the reservoir. For the application of this Method in ramifies networks, is used a program of computer in C language. This process is divided in two stages: attainment of the previous solution and reduction of the piezometric quota of headboard. In the attainment of the previous solution, the minors possible diameters are used that guarantee the limit of maximum speed and the requirements of minimum pressures. The piezometric quota of headboard is raised to guarantee these requirements. In the second stage of the Granados Method, an iterative process is used and it objective is to reduce the quota of headboard gradually, considering the substitution of stretches of the network pipes for the subsequent diameters, considering a minimum addition of the network cost. The diameter change is made in the optimal stretch that presents the lesser Exchange Gradient. The process is locked up when the headboard quota of desired is reached. The optimized network s material costs are calculated, and is made the analysis of the same ones, through the comparison with the conventional network s costs

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work intends to develop an approach based through scientific criteria in the operational diagnosis of ponds of stabilization, starting from analyses accomplished in loco and in laboratory of 78 systems of sewer treatment through ponds of stabilization in the State of Rio Grande do Norte. The objectives of the research are: to map, to evaluate and to diagnose the operational acting of the ponds of stabilization of the state of Rio Grande do Norte, through visits in loco and analyses laboratory; to build a SIG, through the map rain, locate the points of releases of sewages of the systems of existent ponds in Rio Grande do Norte, as well as operational data and his/her respective efficiency diagnosis in the removal of BOD and Coliforms Termotolerantes; to evaluate, in real scale, three systems of ponds of stabilization of RN in the operational efficiency for the parameters BOD5, COD, pH, Temperature, OD and Coliforms Termotolerantes. Of 78 ETEs of appraised RN just, 9% or 7 had maximum concepts in what concerns the removal of BOD and Coliforms Termotolerantes and 41% or 32, they had the worst concepts in term of operational efficiency. The flowing concentrations ETEs of RN of BOD and Coliforms were of 410mg/L and 2,50x107UFC/100ml, the predominant configuration is of the type F1+M1+M2, the relationship BOD/COD revealed for the sewer tributary characteristic biodegradable high. For the study of case of 3 ETEs, the best operational efficiencies in decreasing order were: Cidade (Municipal district), it Roça (State) and São Miguel (SAAE). The removals of final BOD were 51,6mg/L; 108,27mg/L and 62,6mg/L, tends efficiency of 82%; 74% and 81%. In term of coliforms removal in the final effluentes were 1,90x103UFC/100ml; 1,50x104UFC/100ml and 3,10x104UFC/100ml, tends efficiencies of 99,99%; 99,95% and 99,90%. In what it concerns the practice of agricultural reúso of cultures consumed raw, none of 3 ETEs assisted the parameters of the Resolution CONAMA 357/05, for other reúso practices, all assisted the categories B and C of OMS. For release in body receiving ETE Cidade just, they assist the demands of the resolution of CONAMA 357/05, by study of purification solemnity of the receiving body. The maintenance lack and operation; exclusive operator in ETEs and operation knowledge was the contributory factors for the operational fall in appraised ETEs of RN

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work broaches the participation of the Jewish community in the urban expansion of Recife, Brazil, during the Dutch period (1630-1654). With the arrival of the Dutch, the village of Olinda, former capital of Pernambuco, was destroyed and Recife received the juridical statute of city (stad), becoming the capital of Dutch Brazil or New Holland. It became the main West Indians Company s entrepot in South Atlantic, serving as naval base, port of call for ships, and point of export of the sugar production of Pernambuco, and import of European goods and African slaves. In order to such administrative, military and economic functions be carried out, the sand isthmus where Recife used to stay, and the fluvial island of Antônio Vaz, received improvements of many sort. The Dutch hydraulic technology was put in practice, with a posture of opposition between civilization and nature. Among military works and production of urban equipments, the rivers shores were land-filled, canals were built, bridges were lifted, and hundreds of buildings were erected. The civil Dutch population of Recife engaged in the process of production of physical space, which brought a sense of collective action towards the formation of the urban, or burgher, community. From the physical to the social space, there was an effort towards Dutch cultural standards in the urban environment. The Zur Israel Jewish community, formed by private civilians, it is, nonemployees of the WIC, engaged in those processes. It produced physical space through the land-filling and improvement of non healthy areas, and was also responsible for the construction of a significant section of the town s buildings and some of urban equipments, such as stores, markets and slave-warehouses, making more dynamic their economical activities. But their social traffic was due to the adaptation of their behavior to the standards of Dutch sociability. Thus, the community body made itself part of the social body. Disposing of internal selfregulation, it produced spaces with their cultural references cemetery, synagogue, texts enjoying benefits of the government. Zur Israel inscribed itself in the universal history of the Jews as the first community of Americas, and had a fundamental part on the emancipation of Jews within Western society

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In Fazenda Belém oil field (Potiguar Basin, Ceará State, Brazil) occur frequently sinkholes and sudden terrain collapses associated to an unconsolidated sedimentary cap covering the Jandaíra karst. This research was carried out in order to understand the mechanisms of generation of these collapses. The main tool used was Ground Penetrating Radar (GPR). This work is developed twofold: one aspect concerns methodology improvements in GPR data processing whilst another aspect concerns the geological study of the Jandaíra karst. This second aspect was strongly supported both by the analysis of outcropping karst structures (in another regions of Potiguar Basin) and by the interpretation of radargrams from the subsurface karst in Fazenda Belém. It was designed and tested an adequate flux to process GPR data which was adapted from an usual flux to process seismic data. The changes were introduced to take into account important differences between GPR and Reflection Seismic methods, in particular: poor coupling between source and ground, mixed phase of the wavelet, low signal-to-noise ratio, monochannel acquisition, and high influence of wave propagation effects, notably dispersion. High frequency components of the GPR pulse suffer more pronounced effects of attenuation than low frequency components resulting in resolution losses in radargrams. In Fazenda Belém, there is a stronger need of an suitable flux to process GPR data because both the presence of a very high level of aerial events and the complexity of the imaged subsurface karst structures. The key point of the processing flux was an improvement in the correction of the attenuation effects on the GPR pulse based on their influence on the amplitude and phase spectra of GPR signals. In low and moderate losses dielectric media the propagated signal suffers significant changes only in its amplitude spectrum; that is, the phase spectrum of the propagated signal remains practically unaltered for the usual travel time ranges. Based on this fact, it is shown using real data that the judicious application of the well known tools of time gain and spectral balancing can efficiently correct the attenuation effects. The proposed approach can be applied in heterogeneous media and it does not require the precise knowledge of the attenuation parameters of the media. As an additional benefit, the judicious application of spectral balancing promotes a partial deconvolution of the data without changing its phase. In other words, the spectral balancing acts in a similar way to a zero phase deconvolution. In GPR data the resolution increase obtained with spectral balancing is greater than those obtained with spike and predictive deconvolutions. The evolution of the Jandaíra karst in Potiguar Basin is associated to at least three events of subaerial exposition of the carbonatic plataform during the Turonian, Santonian, and Campanian. In Fazenda Belém region, during the mid Miocene, the Jandaíra karst was covered by continental siliciclastic sediments. These sediments partially filled the void space associated to the dissolution structures and fractures. Therefore, the development of the karst in this region was attenuated in comparison to other places in Potiguar Basin where this karst is exposed. In Fazenda Belém, the generation of sinkholes and terrain collapses are controlled mainly by: (i) the presence of an unconsolidated sedimentary cap which is thick enough to cover completely the karst but with sediment volume lower than the available space associated to the dissolution structures in the karst; (ii) the existence of important structural of SW-NE and NW-SE alignments which promote a localized increase in the hydraulic connectivity allowing the channeling of underground water, thus facilitating the carbonatic dissolution; and (iii) the existence of a hydraulic barrier to the groundwater flow, associated to the Açu-4 Unity. The terrain collapse mechanisms in Fazenda Belém occur according to the following temporal evolution. The meteoric water infiltrates through the unconsolidated sedimentary cap and promotes its remobilization to the void space associated with the dissolution structures in Jandaíra Formation. This remobilization is initiated at the base of the sedimentary cap where the flow increases its abrasion due to a change from laminar to turbulent flow regime when the underground water flow reaches the open karst structures. The remobilized sediments progressively fill from bottom to top the void karst space. So, the void space is continuously migrated upwards ultimately reaching the surface and causing the sudden observed terrain collapses. This phenomenon is particularly active during the raining season, when the water table that normally is located in the karst may be temporarily located in the unconsolidated sedimentary cap

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate through radiographic and microscopic analysis the efficiency of the filling techniques by vertical hidraulic compression after the root canal mechanical instrumentation in vitro as well to evaluate the marginal apical leakage through macroscopic and microscopic analysis. Thirty human mandibular molars were used , they were divided on three groups, these were subdivided on six subgroups with five specimens each, come down to 106 root canals filled. Initially, the teeth were instrumented with Profile system series 29 and filled with two ways: single accessory cone or single cone associated with gutta-percha secundary cone, with Fill Canal sealer or Sealer 26. Completed the filling, the teeth were coated with araldit and finger -nail polish except for the apical 2 mm and dried for 3 hours, thep radiographs were taken of the teeth in orto and disto-radiai directions. Next, the coronal seal was carried out with composite resin photopolymerized and with their process of making impermeable. Teeth of positive controls were used without araldit and finger-nail polish whereas the negative controls were used with total coat of araldit and finger-nail polish. The specimens were placed in 2% Methylene Blue dye for 24 hours and thermocycled for 7 days. Afterwards, sections were made of each tooth at mesial and distal roat, after this the teeth were radiographed at buccolíngual direction for a macroscopic analysis and at buccolingual and mesiodistal directions for assessment of the marginal apical leakage. Cross sections were made 3 mm to 3mm since the tooth apice. The sections obtained for each group were observed with a stereomicroscope to evaluate the quality of the root canal filling and the marginal apical leakage. The results showed that: In the four techniques the marginal dye leakage was present in the apical third; in all groups the quality of the root canal filling in the radiography was better at mesial root canal and the single cone technique showed inefficient when only a single distal root canal was present. In the radiographic evaluation the best quality of the root canal filling was observed in the 1A group (single accessory cone + FiIl Canal), as in the mesial root as in the distal root wich Shcwed twe root canals: when the distaI root had only one canal. the best result was showed by 28 group (single accessory cone associated with secundary cone + Fill Canal) In the macroscopic analysis of longitudinal !eaKage (outside surface). less leakage was showed as In the mesial root as in the distal root in the negative control group (3) followed 2A group (single accessory cone + Sealer 26). When the microscopic analysis of tranversal leakage of both roots (inside surface) was carried out. the groups that showed less dye leakage were the negative control (38) followed the 28 group (single acessory cone associated with secundary cone + Sealer 26). The homogeneity o filling was best noted in the 1 A group (.single accessoty cone + Fill Canal). The groups that showed less dye penetration in the tranversal leakage (total area) were negative control (3B) and 2B

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tailings dams are structures that aims to retain the solid waste and water from mining processes. Its analysis and planning begins with searching of location for deployment, step on which to bind all kinds of variables that directly or indirectly influence the work, such as geological, hydrological, tectonic, topographic, geotechnical, environmental, social characteristics, evaluation security risks, among others. Thus, this paper aims to present a study on the most appropriate and secure type of busbar to design a layout structure of iron ore tailings, taking into account all the above mentioned variables. The case study involves the assessment of sites for location of dams of tailings disposal beneficiation of iron mine to be built in Bonito, in the municipality of Jucurutu in Seridó Potiguar. For site selection among alternatives, various aspects of the current state of the art were considered, one that causes the least environmental impact, low cost investment, adding value to the product and especially the safety of the implanted structure mitigates the concern about induced earthquakes as a result of liquefaction wastes somatized by dams in the region, as the tilling of Mina Bonito is located practically in the hydraulic basin dam Armando Ribeiro in environmental protection (APA). The methodology compares induced by dams in the semiarid region with the characteristics of the waste disposal and sterile seismicity, taking into account the enhancement of liquefaction by the action of seismicity in the Mina Bonito region. With the fulcrum in the methodology, we indicated the best busbar type for disposal of tailings from iron ore or combination of them, to be designed and built in semiarid particularly for Mina Bonito. Also presents a number of possible uses for the tailings and in engineering activities, which may cause processing to the common good.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Building installations of cold water are key parts in any model of housing, are homes or condos. However, these systems are subject to failure, which can range from a leak in a device until faults in the structure of water reservoirs and distribution system. These faults are responsible for great economic and environmental costs. In order to reduce these losses, this work proposes the development of a system able to detect the presence and identify some types of water leaks that may occur. For implementation and testing, consumption model was used in a simulator capable of reproducing a similar behavior to a real model and its consequent failures. The detection of leaks is done based on an expert like model having two detection modules, one active and one passive, which use an array of sensors and actuators (valves) to do the sensing. For testing and implementation has been developed a software capable of coupling the system simulator and detector. From the results it can be seen that the system proposed in this work, as well as functioning satisfactorily, can be easily implemented in microcontrollers or embedded systems due to its simplicity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study area is within the Pirangi River Basin, eastern sector of Rio Grande do Norte state, where is located of the Parnamirim city. It has an area of approximately 370 km². Urbanization has developed much fast without an appropriate infrastructure, mainly by the lack of sewage systems, with risks of contamination of groundwater that may cause serious damage to the health of the population. The Barreiras Aquifer System groundwater in the area represents the main source of water supply for urban and rural populations. The use of groundwater occurs without adequate planning and therefore, important recharge areas are being occupied. This study was conducted to quantify the use and evaluation of the potential of groundwater, in order to increase good water quality supply and lower risks of being affected by polluting activities. With these objectives, the following activities were carried out: 268 points of water have been registered; characterization of the lithological, thickness and hydrogeological structure of the Barreiras aquifer, based on the correlation of well logs; and evaluation of hydrodynamic parameters of the aquifer, from the interpretation of results well pumping tests. It was found that the saturated thickness increases from west to east towards the sea, with values ranging from 15,47-56,5 m with an average of 32,45 m. The hydrodynamic parameters using Cooper-Jacob method were: average transmissivity of 5,9x10-3 m²/s and average hydraulic conductivity 2,82x10-4 m/s. The effective porosity is of 15%, obtained by applying Biecinski equation. The potentiometric map shows the main direction of groundwater flow, from west to east, and identifies the recharge areas corresponding to the region of the tablelands of the "Barreiras". The river valleys refer to the discharge areas of the aquifer system. The Recharge was estimated at 253 mm/year, which corresponds to the 16.4% rate of infiltration.