117 resultados para Vacâncias de oxigênio
Resumo:
The urban drainage is one of the powers of environmental sanitation and its scope is the quantitative and qualitative aspects. In decision making of managers and the engineering aspects of design are almost always taken into account only the quantitative aspects. However, the waters of the runoff have the highest concentrations of pollutants at the beginning of precipitation. Thus, if the plot pollution removed, the remaining portion can be used for other purposes. This work has aimed to present the variation of water quality of two drainage basins in the city of Natal / RN-Brazil to support the implementation of drainage to consider the qualitative aspect, and identify potential for the use of water. The basins (M and C) are analyzed closed-type, are in the urban area, are predominantly residential occupation and its waters are used for detention ponds and infiltration. The samples were divided into three phases, the first two direct to final points in a basin and the third in traps distributed over the surface drainage. The parameters had been analyzed were pH, conductivity, dissolved oxygen, Color, Turbidity, COD, Ammonia, nitrite, nitrate, total phosphorus, orthophosphate, Sediments solids, total solids, chloride, sulfate, alkalinity, calcium, magnesium, sodium, potassium, Heavy Metals (Chromium, Cadmium, Lead, Zinc and Copper), Eschichia coli and total coliforms. The parameters studied showed high initial pollution load, events and located in different proportions, except nitrite, heavy metals and biological indicators. The size of the surface drainage and topographic its features influence the quality of water. However, the form of sampling is crucial in the qualitative study in the basin. The samplers developed at work, were generated economic and representative results. The urban rainwater presents organic faecal indicators. The runoff of water from both basins shows no risk of salinity and sodicity for use in irrigation, should be noted the content of chloride in the choice of method of irrigation
Resumo:
Eutrophication has been listed as one of the main problems of water pollution on a global level. In the Brazilian semi-arid areas this problem takes even greater proportions due to characteristical water scarcity of the region. It is extremely important to the predictive eutrophication models development and to the reservoirs management in the semi-arid region, studies that promotes understanding of the mechanisms responsible for the expansion and control of algae blooms, essential for improving the water quality of these environments. The present study had as its main aims, evaluate the temporal pattern of trophic state, considering the influence of nutrients (N and P) and the light availability in the water column in the development of phytoplankton biomass, and perform the mathematical modelling of changes in phosphorus and chlorophyll a concentrations in the Cruzeta man-made lake located on Seridó, a typical semi-arid region of Rio Grande do Norte. To this, a fortnightly monitoring was performed in the reservoir in 05 stations over the months of March 2007 to May 2008. Were measured the concentrations of total phosphorus, total organic nitrogen, chlorophyll a, total, fixed and volatile suspended solids, as well as the measure of transparency (Secchi) and the profiles of photosynthetic active radiation (PAR), temperature, pH, dissolved oxygen and electrical conductivity in the water column. Measurements of vertical profiles have shown some periods of chemical and thermal stratification, especially in the rainy season, due to increased water column depth, however, the reservoir can be classified as warm polimitic. During the study period the reservoir was characterized as eutrophic considering the concentrations of phosphorus and most of the time as mesotrophic, based on the concentrations of chlorophyll a, according to the Thornton & Rast (1993) classification. The N:P relations suggest N limitation, conversely, significant linear relationship between the algae biomass and nutrients (N and P) were not observed in our study. However, a relevant event was the negative and significant correlation presented by Kt and chlorophyll a (r ² = 0.83) at the end of the drought of 2007 and the rainy season of 2008, and the algal biomass collapse observed at the end of the drought season (Dec/07). The equation used to simulate the change in the total phosphorus was not satisfactory, being necessary inclusion of parameters able to increase the power of the model prediction. The chlorophyll a simulation presented a good adjustment trend, however there is a need to check the calibrated model parameters and subsequent equation validation
Resumo:
Environmental impacts are defined as the processes of social and ecological changes caused by nuisance ambient. In agriculture are diverse, and the intensive use of land and inappropriate agricultural practices causes negative effect on the environment besides affecting crop productivity and quality of life of man. So this study was objective to analyze parameters indicators of environmental impacts in the Cruzeta the Discrict Irrigation. During the period July 2007 to March 2008 samples were collected in lot 01 and 02 of the irrigation district. The monitoring was conducted in four sampling points, three (3) located in the irrigation channels and 1 (one) located in a cacimbão. Were monitored pH, CE, STD, SS, NO3-, OD, DT, PST, RAS, CT, Ca+2, Mg+2, Na+ and K+ and heavy metals. Analysis was performed, soil fertility, determining the infiltration rate, moisture content of soil and flow measurement. The results showed that the parameters considered most effective in evaluating the indicators of environmental impacts were: Suspended solid, turbidity, dissolved oxygen and Coliform termotelerantes. The concentrations of nitrate were below the limit established by CONAMA (2005). High levels of STD were found in the point P4. The risk of salinity in cacimbão Lot 02, the water was classified as Class II, or medium risk of salinity in the remaining points was classified as Class I. The iron and aluminum were found high concentrations in four sampling points independent of the dry or rainy. On the ground, found high levels of phosphorus in both samples collected in the batch 01, as the lot 02. The pH levels found in samples of soil, the soil can be classified as neutral and moderate alkalinity. The high infiltration rate obtained in the tests performed in lots 01 and 02 indicated the high permeability of soil at these points
Resumo:
Urban growth of metropolitan areas has produced impacts of considerable importance on environment and water resources. Such impacts are in general associated with human activities, such as basin area uncontrolled development. In this context, Pitimbu river watershed, located at Natal metropolitan area, has been affected by uncontrolled development caused by urban expansion. Indeed, such effects have been reflected on water quantity and quality, which may produce social consequences. Pitimbu river is an important water supplier for human consumption, actually supplying a 2600 m3/h water discharge. This study aims to analyze the qualitative and quantitative aspects of water and sediment on Pitimbu river lowland portion. For this purpose, physical-chemical water properties were analyzed, and sediment macro invertebrates benthonic were monitored in two cross sections in a period between November 8th, 2007 and October 3rd, 2008. Monitoring methodology consisted of water and sediment sampling for laboratory analysis. Water quality analysis included Dissolved Oxygen, Oxygen Biochemical Demand, Nitrate, pH and Alkalinity, Suspended and Total Solids. The analysis of heavy metals in the sediment included Cadmium, Cobalt, Copper, Chrome, Silver and Nickel. Dry season water discharge data were measured and used to adjust recession function parameters, whose values reveal quick recession and strong river-aquifer unconfined interaction. Water quality analysis revealed the absence of degradation by organic composites. However, DO and BOD levels indicate that more consistent results could be provided if sampling time interval were reduced. Biomonitoring showed signs of aquatic ecosystem degradation by the absence of sensitive and abundance of resistant benthic organisms. Obtained results demonstrate the urgent need of effective management measures to provide environmental protection. The increase of environmental degradation will certainly make impracticable the use of water for human consumption
Resumo:
This study investigates a new treatment system of wastewater by anaerobic and aerobic biological filters for nitrogen modification. The main objective of this study was evaluate, on a pilot scale, quantitatively and qualitatively the bacterian nitrifying community in a experimental sewage treatment system made by aerobics biological filters in series, in search of figure out the dynamic of nitrogen modification process. It was collected and laboratorial analysed microbiologically, regarding NMP of Nitrosomonas e Nitrobacter, and physical-chemically considering nitrogen sequence. We conclude that: the association in aerobic biological filters under nutrition controlled conditions and oxygen level allows the appearance of bacterian community responsible for the nitrogen modification; the method used, despite its limitations, provided the selection of autotrophic nitrifying microorganisms, allowing the identification of Nitrosomonas and Nitrobacter; the flow direction tested in the experimental unit did not affect the nitrifying bacterial community, certainly because they were kept drowned and did not occur flow speed that could breake the formed biomass; the nitrification process happened in aerated biological filters in all phases of the research, comproved by microbiological tests; in the third phase of the research the increase of the oxygen rate was significant for the nitrificant bacterian community in the aerate biological filters, allowing its growth, occurring relation between the efficiency of nitrification system and the quantity of organisms responsible for this process; the conduit used in aerated biological filters showed satisfactory performance support material to the nitrifying bacteria development
Resumo:
Although the good performance in organic matter and suspended solids removal, the anaerobic reactors are unable to remove ammonia nitrogen from sewage, which makes indispensable to include a step of post-treatment for removal of ammonia or nitrate as necessary. This paper presents the performance of a new variant technology, where the nitrification unit, preceded by anaerobic units, is a submerged aerated biological filter, without continuous sludge discharge in their daily operation. The oxygenation system is very simple and inexpensive, consisting of perforated hoses and compressors. The anaerobic reactors are a septic tank with two chambers followed (8.82 m³) and two parallel anaerobic filters (36 m³ each) filled with ceramic bricks and conics plastic parts. Both followed aerated filters were filled with cut corrugated conduit. The study evaluated the behavior of the system with constant domestic sewage flow (10 m³/d) and different aeration conditions, are these: stage 01, when applied air flow of 0.01 m³ air/min in both aerated filter; stage 02, remained in the initial air flow rate in the second aerated filter and increased at the first to 0.05 m³ air/min; at last, at last, in stage 03, the air flow rate of first aerated filter was 0.10 m³ air/min and on the second remained at 0.01 m³ air/min. The filter FA1 received load of 0.41 kg COD/m³.d, 0.37 kg COD/m³.d and 0.26 kg COD/m³.d on phases 01, 02 and 03, respectively. The FA2 received loads of 0.25 kg COD/m³.d, 0.18 kg COD/m³.d and 0.14 kg COD/m³.d on phases 01, 02 and 03, respectively. During stage 01, were found the following results: 98% removals of BODtotal and 92% of CODtotal, with effluent presenting 9 mg/L of BODtotal final average and 53 mg/L of CODtotal average; suspended solids removals of 93%, with a mean concentration of 10 mg/L in the final effluent; 47% reduction of ammonia of FA2 to FAN 's, presenting average of 28 mg NNH3/ L of ammonia in the effluent with; the dissolved oxygen levels always remained around 2.0 mg/L. During stage 02, were found removals of 97% and 95% to BODtotal and suspended solids, respectively, with average final concentrations of 8 and 7 mg/L, respectively; was removed 60% of ammonia, whose final concentration was 16.3 mg NNH3/ L, and nitrate was increased to a final average concentration of 16.55 mg N-NO3/L. Finally, the stage 03 provided 6 mg/L of DBOtotal (98% removal) and 23 mg/L of CODtotal (95% removal) of final effluent concentrations average. At this stage was identified the higher ammonia oxidation (86%), with final effluent showing average concentration of 6.1 mg N-NH3/L, reaching a minimum of 1.70 mg N-NH3/L. In some moments, during stage 03, there was a moderate denitrification process in the last aerated filter. The average turbidity in the effluent showed around 1.5 NTU, proving the good biomass physical stability. Therefore, the results demonstrate the submerged biological filters potential, filled with high void ratio material (98%), and aerated with hoses and compressor adoption, in the carbonaceous and nitrogenous matter oxidation, also generating an effluent with low concentration of solids
Resumo:
The detention and infiltration ponds of urban drainage system has function to protect the population from undesirable effects of floods. In general these ponds are not completly used and it potential is wasted. As it are disseminated at different places at cities it can reduce costs with water transport and permit water preservation of best quality. Some it utilities includes use in green areas irrigation, industrial among than cooling towers and boiler, soil compaction, cleaning urban road, pisciculture and fire fighting system. The quality these water is influenced by anauthorized sewage in the drainage system. This study was performed in six detention and infiltration ponds at drainage system of Natal, which aim was to verify the non-portable use these ponds on urban environment. As indirect aim would to incentive the water utilization these ponds as a water source to another uses in urban environment. These ponds represents the characteristics of detention and infiltration of Natal city and consequently of Brazil. As the water quality, the ponds presents following characteristics: three has apparently good quality, other showed intermediate condition and two had water polluted. Were performed twenty sample in each ponds and the following parameters assessed: pH, temperature, dissolved oxygen, turbidity, electrical conductivity, coliform thermotolerant, ammonia, organic nitrogen, TKN, nitrate, total phosphorus and alkalinity, bicarbonate, chloride, total hardness, calcium and magnesium hardness, total solids, TSS, TDS, COD and SAR°. To utilization on pisciculture we recommend use in ponds which presents the best quality. Only one pond presented higher pollutants and it not being appropriated for use in cooling tower. The content of solids suspension restricted the water use in all ponds in boilers. As water use in soil compaction, cleaning urban road and fire fighting system the water from these ponds are not appropriated. However, the recommended limits from literature are to domestic sewage, due to this, the parameters are restrictive to diminish the sanitary risk that could be offered with it utilization. The infiltration velocity of water these assessed ponds restrict a moderato use, however the effects are potentiated only in soil less sandy, which not occur in Natal. It is recommend the unrestricted irrigation utilization in ponds with best quality of water, and a restricted irrigation to ponds with worst quality of water. As load of pollutants, it is recommended a complementary treatment in those ponds whit higher load to diminish sanitary risks. In only one pond was found one helminth eggs and due to the convention formula of results, it was found for all ponds less than 1 helminth/liter eggs.
Resumo:
The improper disposal of nitrogen in receiving water courses causes problems such as toxicity to living beings through the consumption of oxygen to meet the nitrogen demand, eutrophication and nitrate contamination of aquifers. For this reason it is often necessary to be carried out complementary treatment of wastewater to eliminate or reduce the concentration of this compound in the wastewater. The objective of this study is to evaluate the biological removal of nitrogen compounds using submerged aerated and anoxic filters as post-treatment of an anaerobic system, with low cost and innovative technology, which in previous studies has shown high removal efficiency of organic matter and great potential biological nitrogen compounds removal. The simple design with perforated hoses for air distribution and filling with plastic parts proved to be very efficient in relation to organic matter removal and nitrification. The system presented, in the best stage, efficiency in converting ammonia to nitrate by 71%, and produced a final effluent concentration below 10 mg / L of NH3-N. In addition, carbon concentration was removed by 77%, producing final effluent with 24 mg/L COD. However, denitrification in anoxic filter was not effective even with the addition of an external carbon source. There was a reduction of up to 56% of nitrogen caused by the process of simultaneous nitrification and denitrification (SND). The high voids space presented by this type of support material coupled with direct aeration of the sludge, allows the respiration of biomass retained between the endogenous phase, increased cell retention time and sludge retention capacity, producing a final effluent with turbidity less than 5 UT and total suspended solids around 5.0 mg/L
Resumo:
This research evaluated the microalgae removal produced in a stabilization pond system using biofilters as post-treatment, besides characterizing the effluents of stabilization ponds and filters in relation to concentrations of algal biomass (chlorophyll a and suspended solids), organic matter (BOD and COD), total phosphorus, orthophosphate, pH and dissolved oxygen, and tried to correlate physicochemical parameters with chlorophyll "a". It was held at the Ponta Negra ETE which is constituted by three stabilization ponds, with a primary facultative pond and two of maturation. For the algae removal were used two submerged bio-filters: the filter FPF (Facultative Pond Filter), fed with facultative pond effluent; and the filter MPF (Maturation Pond Filter), fed with second maturation pond effluent. The filling material of both filters was predominantly gravel no. 2, although it contains portions of gravel no. 1 and no. 3. The filters operating conditions were bad, they were nearly 10 years without maintenance, without cleaning or removal of sludge since the time of its construction, and part of the filling material may be obstruct. Despite poor operating conditions were obtained satisfactory results, in level of posttreatment. Removal efficiencies in relation to BOD and COD were 7 and 25% in FPF and 9 and 19% and in MPF, respectively. In relation to TSS efficiencies in MPF and FPF were 37 and 20%, respectively. As for the chlorophyll "a" removal, the FPF efficiency was 44% and the MPF was 40%. There was 50% of consumption of dissolved oxygen, on average, within the filters. Two profiles were performed in the filters, and it was possible to conclude that variations throughout the day were not statistically significant, and that, regardless of the time of collection, they would have the same representation comparing to the time of data collection (7 am) and the daily average, although individual variations throughout the day have been shown to be significant. Another important observation is that the correlations between Chlorophyll a and TSS were bigger and more significant in the effluent of the filters than in the effluent of the ponds
Resumo:
Waste stabilization ponds are the main technology in use for domestic sewage treatment in Rio Grande do Norte State (RN), northeast Brazil. The are around 80 systems, constructed mainly by municipal city halls, being series comprised by a primary facultative pond followed by two maturation ponds the most used configuration. Due to problems related with the production and destination of sludge and generation of bad odors, the designers have avoided the use of anaerobic lagoons. The majority of systems are rarely monitored to verify their efficiencies and to get new project parameters for future designing. This work has as purpose to make a diagnosis of efficiency of three series of waste stabilization pond series (WSPS) of Jardim Lola 1, Jardim Lola 2 and Beira Rio, located in the North Zone of the city of the Natal/RN, treating domestic raw sewage, on the removal of organic matter and thermotolerant coliform, comparing the operational conditions of the systems this inside of the bands foreseen in the project, through parameters BOD5, QOD, thermotolerant coliforms, dissolved oxygen, pH, temperature, ammoniac nitrogen, total and suspended solids. The work was carried through in the WSPS, all constituted by a primary facultative pond followed by two maturation ponds. Socioeconomic characteristics of population are predominantly low and all the plants are very near of the contributing basins. The series were monitored from of May the November of 2002, totalizing 20 collections of grab samples of raw sewage and ponds effluents between 8:00 and 9:50 h. The main aspect to be detached by the results was the great concentration of organic matter (BOD and COD) and microorganisms the raw sewage which were around two times more concentrated than those values foreseen one in project. Considering all series the highest removals of organic matter were observed in system Beira Rio (84 and 78% of BOD and COD, respectively), which presented high hydraulic detention time (TDH = 89 days). On the other hand, Jardim Lola 1 and Jardim Lola 2 presented a much lower values of HDT (36 days and 18 days respectively) and their removals of BOD and COD were the same (76% and 60%, respectively). The Beira Rio WSPS, was the most efficient verified in relation to solids and ammonia, proving the great influence of the operational variables such as HDT and applied surface organic loadings on the performance of pond series. Although the treatment plants have reached efficiencies of thermotolerant coliforms around 99,999%, the concentrations in the final effluent can be considered very high for launching in aquatic bodies, particularly those produced by Jardim Lola 1 and Jardim Lola 2 series
Resumo:
In the present work we use a plasma jet system with a hollow cathode to deposit thin TiO2 films on silicon substrates as alternative at sol-gel, PECVD, dip-coating e magnetron sputtering techniques. The cylindrical cathode, made from pure titanium, can be negatively polarized between 0 e 1200 V and supports an electrical current of up to 1 A. An Ar/O2 mixture, with a total flux of 20 sccm and an O2 percentage ranging between 0 and 30%, is passed through a cylindrical hole machined in the cathode. The plasma parameters and your influence on the properties of deposited TiO2 films and their deposition rate was studied. When discharge occurs, titanium atoms are sputtered/evaporated. They are transported by the jet and deposited on the Si substrates located on the substrate holder facing the plasma jet system at a distance ranging between10 and 50 mm from the cathode. The working pressure was 10-3 mbar and the deposition time was 10 -60 min. Deposited films were characterized by scanning electron microscopy and atomic force microscopy to check the film uniformity and morphology and by X-ray diffraction to analyze qualitatively the phases present. Also it is presented the new dispositive denominate ionizing cage, derived from the active screen plasma nitriding (ASPN), but based in hollow cathode effect, recently developed. In this process, the sample was involved in a cage, in which the cathodic potential was applied. The samples were placed on an insulator substrate holder, remaining in a floating potential, and then it was treated in reactive plasma in hollow cathode regime. Moreover, the edge effect was completely eliminated, since the plasma was formed on the cage and not directly onto the samples and uniformity layer was getting in all sampl
Resumo:
Introduction: The ability to walk is impaired in obese by anthropometric factors (BMI and height), musculoskeletal pain and level of inactivity. Little is known about the influence of body adiposity and the acute response of the cardiovascular system during whole the 6-minute walk test (6mWT). Objective: To evaluate the effect of anthropometric measures (BMI and WHR waist-to-hip ratio), the effort heart and inactivity in ability to walk the morbidly obese. Materials and Methods: a total 36 morbidly obese (36.23 + 11.82 years old, BMI 49.16 kg/m2) were recruited from outpatient department of treatment of obesity and bariatric surgery in University Hospital Onofre Lopes and anthropometric measurements of obesity (BMI and WHR), pulmonary function, pattern habitual physical activity (Baecke Questionnaire) and walking capacity (6mWT). The patient was checking to measure: heart rate (HR), breathing frequency (BF), peripheral oxygen saturation, level of perceived exertion, systemic arterial pressure and duplo-produto (DP), moreover the average speed development and total distance walking. The data were analysed between gender and pattern of body adiposity, measuring the behavior minute by minute of walking. The Pearson and Spearmam correlation coefficients were calculated, and stepwise multiple Regression examined the predictors of walking capacity. All analyses were performed en software Statistic 6.0. Results: 20 obese patients had abdominal adiposity (WHR = 1.01), waist circumference was 135.8 cm in women (25) and 139.8 cm in men (10). Walked to the end of 6mWT 412.43 m, with no differences between gender and adiposity. The total distance walked by obesity alone was explained by BMI (45%), HR in the sixth minute (43%), the Baecke (24%) and fatigue (-23%). 88.6% of obese (31) performed the test above 60% of maximal HR, while the peak HR achieved at 5-minute of 6mWT. Systemic arterial pressure and DP rised after walking, but with no differences between gender and adiposity. Conclusion: The walk of obese didn´t suffers influence of gender or the pattern of body adiposity. The final distance walked is attributed to excess body weight, stress heart, the feeling of effort required by physical activity and level of sedentary to obese. With a minute of walking, the obeses achieved a range of intensity cardiovascular trainning
Resumo:
Backgroud: Obesity is a major public health problem and is related to the low physical capacity when obese are compared to no-obese people, however the cause of this limitation is not completely understood. The measurement associated of physiological response to the telemetric 6MWT adds information of metabolic and respiratory system for diagnose of the functional limitation. Objective: Analyze physiological, metabolic and ventilatory responses in women with different body fat during the 6MWT. Methods: 32 women (8 non-obese, 8 Overweight, 8 Obese and 8 morbidly obese) were evaluated for anthropometry, lung function and exercise capacity. Results: Morbidly obese walked the shortest distance (400.2±38.7m), had lower VO2/Kg (12.75±3.20l/Kg/min) and lower R (0.74± 0.11) in the 6MWT compared to other groups. Analyses of metabolic (VO2 and VCO2) and respiratory (VE, VT and BF) during the test did not identify differences between groups. The evaluation of cardiac function (O2 pulse) found higher values in the OM (12.3 ± 4.9ml/bat). Conclusion: The OM had worse performance in the 6MWT compared to other groups. The physical performance may be reduced in this population related to a protocol-dependent response because the speed of 6MWT is self-adjusted allows the individual himself select the intensity of the test, making it set at a speed where there is energy saving
Resumo:
Introduction: Pneumonia is an inflammatory lung disease and it is the greatest cause of deaths in children younger than five years of age worldwide. Chest physiotherapy is widely used in the treatment of pneumonia because it can help to eliminate inflammatory exudates and tracheobronchial secretions, remove airway obstructions, reduce airway resistance, enhance gas exchange and reduce the work of breathing. Thus, chest physiotherapy may contribute to patient recovery as an adjuvant treatment even though its indication remains controversial. Objectives: To assess the effectiveness of chest physiotherapy in relation to time until clinical resolution in children (from birth up to 18 years old) of either gender with any type of pneumonia. Methods: We searched CENTRAL 2013, Issue 4; MEDLINE (1946 to May week 4, 2013); EMBASE (1974 to May 2013); CINAHL (1981 to May 2013); LILACS (1982 to May 2013); Web of Science (1950 to May 2013); and PEDro (1950 to May 2013). We consulted the ClinicalTrials.gov and the WHO ICTRP registers to identify planned, ongoing and unpublished trials. We consulted the reference lists of relevant articles found by the electronic searches for additional studies. We included randomised controlled trials (RCTs) that compared chest physiotherapy of any type with no chest physiotherapy in children with pneumonia. Two review authors independently selected the studies to be included in the review, assessed trial quality and extracted data. Results: Three RCTs involving 255 inpatient children are included in the review. They addressed conventional chest physiotherapy, positive expiratory pressure and continuous positive airway pressure. The following outcomes were measured: duration of hospital stay, time to clinical resolution (observing the following parameters: fever, chest indrawing, nasal flaring, tachypnoea and peripheral oxygen saturation levels), change in adventitious sounds, change in chest X-ray and duration of cough in days. Two of the included studies found a significant improvement in respiratory rate and oxygen saturation whereas the other included study failed to show that standardised respiratory physiotherapy and positive expiratory pressure decrease the time to clinical resolution and the duration of hospital stay. No adverse effects related to the interventions were xvi described. Due to the different characteristics of the trials, such as the duration of treatment, levels of severity, types of pneumonia and the techniques used in children with pneumonia, as well as differences in their statistical presentation, we were not able to pool data. Two included studies had an overall low risk of bias whereas one included study had an overall unclear risk of bias. Conclusion: Our review does not provide conclusive evidence to justify the use of chest physiotherapy in children with pneumonia due to a lack of data. The number of included studies is small and they differed in their statistical presentation
Resumo:
The term fatigability concerns the degree of fatigue associated with performing an activity of any type (physical, mental, emotional and / or social). Recently scales for assessing fatigue in the English language were created, however, gaps exist regarding the validity of these scales in relation to oxygen consumption and levels of perceived fatigue. Objective: To investigate the validity of perceived fatigability scale in older women frail and non-frail by the expired gases kinetics. Methods: This is a study of type validation, where were evaluated 48 elderly. The evaluation was conducted at two different sessions. In the first, data were collected demographic partners, as well as assessment of cognitive function, physical health, and the phenotype of frailty. The second was composed by the test 6-minute walk (6MWT) associated the expired gases kinects and assessment of perceived fatigability. Statistical analysis was performed a descriptive analysis and then we used the Pearson correlation test to evaluate the relationship between the measure of perceived fatigue and variables oxygen consumption (VO2), carbon dioxide production (VCO2), respiratory exchange ratio (RER)before and after 6MWT. We used a linear regression model initially considering the following explanatory variable: age, Body Mass Index (BMI), presence of frailty, comorbidities, level of physical activity, distance covered in the 6MWT , the energy cost of walking and severity of fatigability on performance. Results: The final sample consisted of 44 elderly women, 4 elderly were excluded because they didn t complete all phases of this study. The mean age obtained was 75 years (± 7.2 years). There was no significant correlation between fatigability measures and the values of VO2 ( r = .09 , p = .56 ) , VCO2 ( r = .173 , p = .26 ) , RER ( r = - .121 , p = .43 ). The final linear regression model showed that the energy cost of walking, the usual level of physical activity and the performance severity of fatigability explained 83.5 % (R2 = 0.835, p < 0.01) of the variation in the perceived fatigability. Conclusion: Our findings indicate a relationship between greater severity of fatigability and lower levels of physical activity and increased energy cost in walking, suggesting that the fatigability analyses using a simple numeric scale is valid and viable for assessment of fatigue in older women