57 resultados para Carga hidráulica superficial


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although the good performance in organic matter and suspended solids removal, the anaerobic reactors are unable to remove ammonia nitrogen from sewage, which makes indispensable to include a step of post-treatment for removal of ammonia or nitrate as necessary. This paper presents the performance of a new variant technology, where the nitrification unit, preceded by anaerobic units, is a submerged aerated biological filter, without continuous sludge discharge in their daily operation. The oxygenation system is very simple and inexpensive, consisting of perforated hoses and compressors. The anaerobic reactors are a septic tank with two chambers followed (8.82 m³) and two parallel anaerobic filters (36 m³ each) filled with ceramic bricks and conics plastic parts. Both followed aerated filters were filled with cut corrugated conduit. The study evaluated the behavior of the system with constant domestic sewage flow (10 m³/d) and different aeration conditions, are these: stage 01, when applied air flow of 0.01 m³ air/min in both aerated filter; stage 02, remained in the initial air flow rate in the second aerated filter and increased at the first to 0.05 m³ air/min; at last, at last, in stage 03, the air flow rate of first aerated filter was 0.10 m³ air/min and on the second remained at 0.01 m³ air/min. The filter FA1 received load of 0.41 kg COD/m³.d, 0.37 kg COD/m³.d and 0.26 kg COD/m³.d on phases 01, 02 and 03, respectively. The FA2 received loads of 0.25 kg COD/m³.d, 0.18 kg COD/m³.d and 0.14 kg COD/m³.d on phases 01, 02 and 03, respectively. During stage 01, were found the following results: 98% removals of BODtotal and 92% of CODtotal, with effluent presenting 9 mg/L of BODtotal final average and 53 mg/L of CODtotal average; suspended solids removals of 93%, with a mean concentration of 10 mg/L in the final effluent; 47% reduction of ammonia of FA2 to FAN 's, presenting average of 28 mg NNH3/ L of ammonia in the effluent with; the dissolved oxygen levels always remained around 2.0 mg/L. During stage 02, were found removals of 97% and 95% to BODtotal and suspended solids, respectively, with average final concentrations of 8 and 7 mg/L, respectively; was removed 60% of ammonia, whose final concentration was 16.3 mg NNH3/ L, and nitrate was increased to a final average concentration of 16.55 mg N-NO3/L. Finally, the stage 03 provided 6 mg/L of DBOtotal (98% removal) and 23 mg/L of CODtotal (95% removal) of final effluent concentrations average. At this stage was identified the higher ammonia oxidation (86%), with final effluent showing average concentration of 6.1 mg N-NH3/L, reaching a minimum of 1.70 mg N-NH3/L. In some moments, during stage 03, there was a moderate denitrification process in the last aerated filter. The average turbidity in the effluent showed around 1.5 NTU, proving the good biomass physical stability. Therefore, the results demonstrate the submerged biological filters potential, filled with high void ratio material (98%), and aerated with hoses and compressor adoption, in the carbonaceous and nitrogenous matter oxidation, also generating an effluent with low concentration of solids

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The detention and infiltration ponds of urban drainage system has function to protect the population from undesirable effects of floods. In general these ponds are not completly used and it potential is wasted. As it are disseminated at different places at cities it can reduce costs with water transport and permit water preservation of best quality. Some it utilities includes use in green areas irrigation, industrial among than cooling towers and boiler, soil compaction, cleaning urban road, pisciculture and fire fighting system. The quality these water is influenced by anauthorized sewage in the drainage system. This study was performed in six detention and infiltration ponds at drainage system of Natal, which aim was to verify the non-portable use these ponds on urban environment. As indirect aim would to incentive the water utilization these ponds as a water source to another uses in urban environment. These ponds represents the characteristics of detention and infiltration of Natal city and consequently of Brazil. As the water quality, the ponds presents following characteristics: three has apparently good quality, other showed intermediate condition and two had water polluted. Were performed twenty sample in each ponds and the following parameters assessed: pH, temperature, dissolved oxygen, turbidity, electrical conductivity, coliform thermotolerant, ammonia, organic nitrogen, TKN, nitrate, total phosphorus and alkalinity, bicarbonate, chloride, total hardness, calcium and magnesium hardness, total solids, TSS, TDS, COD and SAR°. To utilization on pisciculture we recommend use in ponds which presents the best quality. Only one pond presented higher pollutants and it not being appropriated for use in cooling tower. The content of solids suspension restricted the water use in all ponds in boilers. As water use in soil compaction, cleaning urban road and fire fighting system the water from these ponds are not appropriated. However, the recommended limits from literature are to domestic sewage, due to this, the parameters are restrictive to diminish the sanitary risk that could be offered with it utilization. The infiltration velocity of water these assessed ponds restrict a moderato use, however the effects are potentiated only in soil less sandy, which not occur in Natal. It is recommend the unrestricted irrigation utilization in ponds with best quality of water, and a restricted irrigation to ponds with worst quality of water. As load of pollutants, it is recommended a complementary treatment in those ponds whit higher load to diminish sanitary risks. In only one pond was found one helminth eggs and due to the convention formula of results, it was found for all ponds less than 1 helminth/liter eggs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stabilization pond system consisting in more sewage treatment used in Rio Grande do Norte (RN), Brazil, representing about 90% of all systems. Fecal bacteria are removed mainly facultative ponds and in maturation ponds. Many factors influence bacterial decay, such as the levels of pH and DO, temperature, light intensity, HDT and nutrient availability. The bacterial decay rate (Kb) is calculated considering many variables, but the hydraulic regime is a significant influence for microorganisms removal, and the dispersed flow which best characterizes a stabilization pond. However, some authors developed equations for the Kb accordant plug flow and complete mixing. This research study aimed to evaluate the bacterial decay of fecal coliform and Enterococcus sp. in stabilization ponds designed to treat domestic sewage, full-scale, in RN. All systems have assessed pretreatment, a facultative pond (LF) followed by two maturation (LM1 and LM2). The parameters availed were: temperature, pH, DO, BOD5, COD, fecal coliform, Enterococcus sp., Chlorophyll a, total suspended solids, fixed and volatile. In general, there were not significant differences for pH, DO and temperature in the ponds, except for the new systems, since they have low flow and hydraulic loads. The removal of organic matter in the ponds was low, about 70%, and nearly all are overloaded organic and operational problems. The bacterial removals were low, with average 96% for LF for fecal coliform, and 98% for Enterococcus sp.; LM1 were in itself a removal for fecal coliform about 71%, and 81% for Enterococcus sp.; LM2 have efficiency of 69% for fecal coliform, and 68% for Enterococcus sp. The equation proposed by Von Sperling (1999), according to the dispersed flow regime, generated empirical values of Kb more approximate to calculated values of Kb. On average, the calculated Kb to coliforms in the LF was 0.31 d-1, and for both maturation ponds were 0.35 d-1. For Enterococcus sp. the average was 0.40 d-1 for LF, 0.55 d-1 for LM1, and 0.58 d-1 for LM2. These results also showed that the Kb obtained in full-scale systems are smaller than those found in pilot-scale ponds. Moreover, one can say that the equation proposed by Marais (1974), according to the complete-mix regime, overestimates Kb. Actual results of Kb indicated that fecal coliforms are more resistant to adverse conditions present in stabilization ponds than Enterococcus sp., therefore, an indicator of microbiological safety and efficiency. The factors significant interventions in the rate of bacterial decay were concentrations of COD, the organic loading and HDT. The few Kb relationship between pH, DO and temperature were not significant. Finally, we conclude that it s essential to correct operation and maintenance, for not performing these activities is one of the main factors contributing to low rates of bacterial decay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The groundwater quality has been compromised as a result of the intensification of human activities over the years. Groundwater contamination by nitrate is one of the effects of this degradation, a socio-environmental problem that affects many regions of the world and particular the city of Natal (RN). Developing techniques for nitrate removal in water is intended to eliminate or reduce the concentration of this compound, and those that involve biological processes have produced economic and environmental advantages. This study proposes a technology for biological removal of nitrate in water supply for humans, using the endocarp s coconut as a carbon source and bacteria support. The experiments were performed in pilot scale anoxic, testing different areas of the substrate surface. Results showed high rates nitrate removal during the monitoring period, noting the occurrence of denitrification after the beginning of system operation. The best performance was achieved in the treatment system containing substrate surface area increased, indicating that the decrease in the endocarp size contributed to increased bacterial activity, improving the ability to remove nitrate. About the quality analyzed aspects of water, it was found that the proposed technology has the potential water use for human consumption

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In semiarid region of northeast Brazil, the majority of reservoirs used for public supply has suffered degradation of water quality affected by diffuse pollution from agricultural and livestock areas of the watershed and by hydrologic regime peculiar to the region, characterized by a rainy season with higher volumes stored in reservoirs and a dry season with a reduction in water level due to high evaporation and increase of eutrophication. The Dourado reservoir, located in Currais Novos city, semiarid region of Rio Grande do Norte state, is one example of a water supply reservoir that can have degradation of water quality and impracticability of their use, due to the high external input of nutrients from non-point sources of watershed during the rainy season and increasing of eutrophication due to decrease the stored volume during the dry period. This study aimed to investigate and quantify diffuse pollution and the hydrologic regime of semiarid region in order to establish standards regarding the water quality of Dourado reservoir. The study period was between the months of May 2011 to March 2012. The diffuse pollution was quantified in terms of watershed from the mass balance of phosphorus in the reservoir, as in relation to areas under different types of land use within the riparian zone of the reservoir from the assessment of soil chemical properties and losses of phosphorus in each area. The influence of hydrological regime on water quality of the reservoir was evaluated from the monthly monitoring of the morphometric, meteorological and limnological features throughout the study period. The results showed that the reservoir has received a high load of phosphorus coming from the drainage basin and presents itself as a system able to retain some of that load tributary, giving an upward trend of the eutrophication process. Diffuse pollution by nutrients from areas under different types of land use within the riparian zone of the reservoir was higher in areas under the influence of livestock, being this area considered a potential diffuse source of nutrients to the reservoir. Regarding the water regime during the rainy season the reservoir was characterized by high concentrations of nutrients and small algal biomass, while in the dry season the reduction of volume and increase of the water retention time of the reservoir, contributing to the excessive growth algal biomass, favoring an increase in eutrophication and deterioration of water quality. In synthesis the water quality of Dourado reservoir is directed by diffuse pollution coming from the drainage basin and the hydrological regime of the peculiar semiarid region, where the rainy season is characterized by high input of allochthonous compounds from the tributaries and erosion of the soil in the reservoir riparian zone, and the dry season characterized by reducing the storage volume due to high evaporation, high residence time of water and consequent degradation of water quality due to the increase of eutrophication process

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Waste stabilization ponds are the main technology in use for domestic sewage treatment in Rio Grande do Norte State (RN), northeast Brazil. The are around 80 systems, constructed mainly by municipal city halls, being series comprised by a primary facultative pond followed by two maturation ponds the most used configuration. Due to problems related with the production and destination of sludge and generation of bad odors, the designers have avoided the use of anaerobic lagoons. The majority of systems are rarely monitored to verify their efficiencies and to get new project parameters for future designing. This work has as purpose to make a diagnosis of efficiency of three series of waste stabilization pond series (WSPS) of Jardim Lola 1, Jardim Lola 2 and Beira Rio, located in the North Zone of the city of the Natal/RN, treating domestic raw sewage, on the removal of organic matter and thermotolerant coliform, comparing the operational conditions of the systems this inside of the bands foreseen in the project, through parameters BOD5, QOD, thermotolerant coliforms, dissolved oxygen, pH, temperature, ammoniac nitrogen, total and suspended solids. The work was carried through in the WSPS, all constituted by a primary facultative pond followed by two maturation ponds. Socioeconomic characteristics of population are predominantly low and all the plants are very near of the contributing basins. The series were monitored from of May the November of 2002, totalizing 20 collections of grab samples of raw sewage and ponds effluents between 8:00 and 9:50 h. The main aspect to be detached by the results was the great concentration of organic matter (BOD and COD) and microorganisms the raw sewage which were around two times more concentrated than those values foreseen one in project. Considering all series the highest removals of organic matter were observed in system Beira Rio (84 and 78% of BOD and COD, respectively), which presented high hydraulic detention time (TDH = 89 days). On the other hand, Jardim Lola 1 and Jardim Lola 2 presented a much lower values of HDT (36 days and 18 days respectively) and their removals of BOD and COD were the same (76% and 60%, respectively). The Beira Rio WSPS, was the most efficient verified in relation to solids and ammonia, proving the great influence of the operational variables such as HDT and applied surface organic loadings on the performance of pond series. Although the treatment plants have reached efficiencies of thermotolerant coliforms around 99,999%, the concentrations in the final effluent can be considered very high for launching in aquatic bodies, particularly those produced by Jardim Lola 1 and Jardim Lola 2 series

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The intrinsic gait disorders in individuals with Parkinson's disease (PD) are one of the most disabling motor symptoms. Among the therapeutic approaches used in attempts to improve the motor function, especially the gait pattern of individuals, stands out the treadmill gait training associated with the addition of load. However, there are few findings that elucidate the benefits arising from such practice. Objective: To assess the effects of adding load on the treadmill gait training in individuals with PD. Material and Methods: A controlled, randomized and blinded clinical trial, was performed with a sample of 27 individuals (18 men and 9 women) with PD, randomly assigned to three experimental conditions, namely: treadmill gait training (n=9), treadmill gait training associated with addition of 5% load (n=9) and treadmill gait training associated with addition of 10% load (n=9). All volunteers were assessed, during phase on of Parkinson's medication, regarding to demographic, clinical and anthropometric (identification form) data, level of disability (Hoehn and Yahr Modified Scale), cognitive function (Mini Mental State Examination), clinical functional - in those areas activity of daily living and motor examination (Unified Parkinson's Disease Rating Scale - UPDRS) and gait cinematic analysis was performed through Qualisys Motion Capture System®. The intervention protocol consisted of gait training in a period of 4 consecutive weeks, with three weekly sessions, lasting 30 minutes each. The post-intervention assessment occurred the next day after the last training session, which was performed cinematic analysis of gait and the UPDRS. Data analysis was performed using the software Statistical Package for Social Sciences® (SPSS) 17.0. Results: The age of volunteers ranged from 41 to 75 years old (62,26 ± 9,07) and the time of clinical diagnosis of PD between 2 to 9 years (4,56 ± 2,42). There was a reduction regarding the score from motor exam domain (p=0,005), only when training with the addition of a 5% load. As for the space-time variables there was no significant difference between groups (p>0,120); however, the training with addition of 5% load presented the following changes: increase in stride length (p=0,028), in step length (p=0,006), in time balance of the most affected member (p=0,006) and reduction in support time of the referred member (p=0,007). Regarding angular variables significant differences between groups submitted to treadmill gait training without addition load and with 5% of load were observed in angle of the ankle at initial contact (p=0,019), in plantar flexion at toe-off (p=0,003) and in the maximum dorsiflexion in swing (p=0,005). While within groups, there was a reduction in amplitude of motion of the ankle (p=0,048), the only workout on the treadmill. Conclusion: The treadmill gait training with addition of 5% load proved to be a better experimental condition than the others because it provided greater gains in a number of variables (space-time and angular gait) and in the motion function, becoming a therapy capable of effectively improving the progress of individuals with PD

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Latices based on acrylic acid and ethyl methacrylate, crosslinked with 1,6‐propoxylate‐hexanodiol diacrylate were synthesized via emulsion polymerization with different monomeric compositions. The resultant latices were thickened with different NaOH/(acrylic acid) molar ratios and were characterized by titrimetry, zeta potential measurements, turbidimetry, and capillary viscometry. Intrinsic viscosity was determined for an uncrosslinked copolymer, using toluene as solvent. All the latices were coagulated with NaCl and washed with water at 60°C analyzed by FTIR spectrophotometry, in order to characterize functional groups from the copolymer and crosslinking agent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chitosan nanoparticles have been used in several systems for the controlled release of drugs. The aim of this study was to obtain and characterize chitosan nanoparticles prepared by the method of coacervation / precipitation using sodium sulfate at different concentrations as the crosslinking agent. The characterization was done using zeta potential and small angle Xray scattering, SAXS. The dispersions of chitosan were obtained at pH 1 and pH = 3. The results of zeta potential at pH = 1 ranged from +64.8 to +29.27 mV and for pH = 3 they varied from +72.4 to +23.48 mV, indicating that the chain of chitosan is positively charged in acidic pH and the behavior of nanoparticles in terms of surface charge was independent of pH. However, the results indicated a dependence of particle size in relation to pH. This difference in behavior was explained by the influence of enthalpic and entropic components

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The knowledge of the rheological behavior of microemulsionated systems (SME) is of fundamental importance due to the diversity of industrial applications of these systems. This dissertation presents the rheological behavior of the microemulsionated system formed by RNX 95/alcohol isopropyl/p-toulen sodium sulfonate/kerosene/distilled water with the addition of polyacrylamide polymer. It was chosen three polymers of the polyacrylamide type, which differ in molar weight and charge density. It was studied the addition of these polymers in relatively small concentration 0,1% in mass and maximum concentration of 2,0%. It was made analysis of flow to determine the appearing viscosities of the SME and rheological parameters applying Bingham, Ostwald de Waale and Herschell-Buckley models. The behavior into saline environment of this system was studied for a solution of KCl 2,0%, replacing the distilled water. It was determined the behavior of microemulsions in relation with the temperature through curves of flow in temperatures of 25 to 60ºC in variations of 5ºC. After the analysis of the results the microemulsion without the addition of polymer presented a slight increase in its viscosity, but it does not mischaracterize it as a Newtonian fluid. However the additive systems when analyzed with low concentration of polymer adjusted well to the applied models, with a very close behavior of microemulsion. The higher concentration of the polymer gave the systems a behavior of plastic fluid. The results of the temperature variation point to an increase of viscosity in the systems that can be related to structural changes in the micelles formed in the own microemulsion without the addition of polymer

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior