38 resultados para Testes de Passeio Aleatório


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The high-intensity interval exercise has been described as an option for increasing physical activity and its use also being suggested in the therapeutic management of many conditions such as diabetes mellitus and heart failure. However, the knowledge of its physiological effects and parameters that can assure greater safety for interval exercise prescription; especially its effect on short- and medium-term (24 hours after exercise) exercise recovery, need to be clarified. This study objective was to evaluate the effect of continuous and interval aerobic exercise on the cardiac autonomic control immediate and medium term (24 hours), by assessing heart rate variability (HRV). The present study is a randomized crossover clinical trial in which healthy young individuals with low level of physical activity had the VFC 24 hours measured by a heart rate sensor and portable accelerometer (3D eMotion HRV, Kuopio, Finland) before and after continuous aerobic exercise (60-70% HR max, 21 min.) and interval exercise (cycle 1 min. 80-90% HR max, 2 min. at 50-60% HR max, duration 21 min.). HRV was measured in the time and frequency domain and the sympathovagal balance determined by the ratio LF / HF. Nonlinear evaluation was calculated by Shannon entropy. The data demonstrated delayed heart rate recovery immediate after exercise and lower HR after 24 hours compared to pre intervention values, especially in the interval exercise group. There was a tendency to higher predominance and representatives index values of sympathetic stimulation during the day in interval exercise group; however, without statistical significance. The study results help to clarify the effects of interval exercise on the 24 hours following interval exercise, setting parameters for prescription and for further evaluation of groups with metabolic and cardiovascular diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The evaluation of seed vigor is an important factor for detection of lots of high quality seeds, so that development of procedures to evaluate the physiological potential has been an important tool in quality control programs seeds. In this sense the study aimed to adapt the methodologies of accelerated aging, electrical conductivity and potassium leaching to evaluate Moringa oleifera seed vigor LAM.. Therefore, four lots of moringa seeds were subjected to the germination tests, seedling emergence, speed of emergence index, emergence first count, length and dry mass of seedlings and cold test for their physiological characterization, in addition to accelerated aging, electrical conductivity and potassium leaching. The experimental design was completely randomized with four replications of 50 seeds and the means compared by Tukey test at 5% probability. For accelerated aging the periods were studied aging 12, 24 and 72 hours at 40, 42 and 45°C. For the electrical conductivity test was used to a temperature of 25°C for periods of 4, 8, 12, 16 and 24 hours of immersion in 75 to 125 mL of distilled water, using 25 to 50 seeds, and for potassium leaching test samples were used 25 to 50 seeds, placed in plastic cups containing 70 and 100 mL of distilled water at 25°C for periods of 1, 2, 3, 4, 5 and 6 hours. From the results obtained, it can be inferred that the methods best fit for the accelerated aging test Moringa seeds were a temperature of 40°C for 12 to 72 hours, 42°C 72 hours 45°C 24 hours . In the electrical conductivity test Moringa seeds, the combination of 50 seeds in 75 mL distilled water for a period of immersion of 4 hours and 50 seeds in 125 mL of 4 hours were efficient for the differentiation of lots of Moringa seeds as to vigor and for potassium leaching test moringa seeds, the combination of 50 seeds in 100mL of distilled water allowed the separation of lots of four levels of vigor, at 2 hours of immersion, showing promise in evaluate the quality of moringa seeds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The evaluation of seed vigor is an important factor for detection of lots of high quality seeds, so that development of procedures to evaluate the physiological potential has been an important tool in quality control programs seeds. In this sense the study aimed to adapt the methodologies of accelerated aging, electrical conductivity and potassium leaching to evaluate Moringa oleifera seed vigor LAM.. Therefore, four lots of moringa seeds were subjected to the germination tests, seedling emergence, speed of emergence index, emergence first count, length and dry mass of seedlings and cold test for their physiological characterization, in addition to accelerated aging, electrical conductivity and potassium leaching. The experimental design was completely randomized with four replications of 50 seeds and the means compared by Tukey test at 5% probability. For accelerated aging the periods were studied aging 12, 24 and 72 hours at 40, 42 and 45°C. For the electrical conductivity test was used to a temperature of 25°C for periods of 4, 8, 12, 16 and 24 hours of immersion in 75 to 125 mL of distilled water, using 25 to 50 seeds, and for potassium leaching test samples were used 25 to 50 seeds, placed in plastic cups containing 70 and 100 mL of distilled water at 25°C for periods of 1, 2, 3, 4, 5 and 6 hours. From the results obtained, it can be inferred that the methods best fit for the accelerated aging test Moringa seeds were a temperature of 40°C for 12 to 72 hours, 42°C 72 hours 45°C 24 hours . In the electrical conductivity test Moringa seeds, the combination of 50 seeds in 75 mL distilled water for a period of immersion of 4 hours and 50 seeds in 125 mL of 4 hours were efficient for the differentiation of lots of Moringa seeds as to vigor and for potassium leaching test moringa seeds, the combination of 50 seeds in 100mL of distilled water allowed the separation of lots of four levels of vigor, at 2 hours of immersion, showing promise in evaluate the quality of moringa seeds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The expansion of cultivated areas with genetically modified crops (GM) is a worldwide phenomenon, stimulating regulatory authorities to implement strict procedures to monitor and verify the presence of GM varieties in agricultural crops. With the constant growing of plant cultivating areas all over the world, consumption of aflatoxin-contaminated food also increased. Aflatoxins correspond to a class of highly toxic contaminants found in agricultural products that can have harmful effects on human and animal health. Therefore, the safety and quality evaluation of agricultural products are important issues for consumers. Lateral flow tests (strip tests) is a promising method for the detection both proteins expressed in GM crops and aflatoxins-contaminated food samples. The advantages of this technique include its simplicity, rapidity and cost-effective when compared to the conventional methods. In this study, two novel and sensitive strip tests assay were developed for the identification of: (i) Cry1Ac and Cry8Ka5 proteins expressed in GM cotton crops and; (ii) aflatoxins from agricultural products. The first strip test was developed using a sandwhich format, while the second one was developed using a competitive format. Gold colloidal nanoparticles were used as detector reagent when coated with monoclonal antibodies. An anti-species specific antibody was sprayed at the nitrocellulose membrane to be used as a control line. To validate the first strip test, GM (Bollgard I® e Planta 50- EMBRAPA) and non-GM cotton leaf (Cooker 312) were used. The results showed that the strip containing antibodies for the identification of Cry1Ac and Cry8Ka5 proteins was capable of correctly distinguishing between GM samples (positive result) and non-GM samples (negative result), in a high sensitivity manner. To validate the second strip test, artificially contaminated soybean with Aspergillus flavus (aflatoxin-producing fungus) was employed. Food samples, such as milk and soybean, were also evaluated for the presence of aflatoxins. The strip test was capable to distinguish between samples with and without aflatoxins samples, at a sensitivity concentration of 0,5 μg/Kg. Therefore, these results suggest that the strip tests developed in this study can be a potential tool as a rapid and cost-effective method for detection of insect resistant GM crops expressing Cry1Ac and Cry8Ka5 and aflatoxins from food samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The expansion of cultivated areas with genetically modified crops (GM) is a worldwide phenomenon, stimulating regulatory authorities to implement strict procedures to monitor and verify the presence of GM varieties in agricultural crops. With the constant growing of plant cultivating areas all over the world, consumption of aflatoxin-contaminated food also increased. Aflatoxins correspond to a class of highly toxic contaminants found in agricultural products that can have harmful effects on human and animal health. Therefore, the safety and quality evaluation of agricultural products are important issues for consumers. Lateral flow tests (strip tests) is a promising method for the detection both proteins expressed in GM crops and aflatoxins-contaminated food samples. The advantages of this technique include its simplicity, rapidity and cost-effective when compared to the conventional methods. In this study, two novel and sensitive strip tests assay were developed for the identification of: (i) Cry1Ac and Cry8Ka5 proteins expressed in GM cotton crops and; (ii) aflatoxins from agricultural products. The first strip test was developed using a sandwhich format, while the second one was developed using a competitive format. Gold colloidal nanoparticles were used as detector reagent when coated with monoclonal antibodies. An anti-species specific antibody was sprayed at the nitrocellulose membrane to be used as a control line. To validate the first strip test, GM (Bollgard I® e Planta 50- EMBRAPA) and non-GM cotton leaf (Cooker 312) were used. The results showed that the strip containing antibodies for the identification of Cry1Ac and Cry8Ka5 proteins was capable of correctly distinguishing between GM samples (positive result) and non-GM samples (negative result), in a high sensitivity manner. To validate the second strip test, artificially contaminated soybean with Aspergillus flavus (aflatoxin-producing fungus) was employed. Food samples, such as milk and soybean, were also evaluated for the presence of aflatoxins. The strip test was capable to distinguish between samples with and without aflatoxins samples, at a sensitivity concentration of 0,5 μg/Kg. Therefore, these results suggest that the strip tests developed in this study can be a potential tool as a rapid and cost-effective method for detection of insect resistant GM crops expressing Cry1Ac and Cry8Ka5 and aflatoxins from food samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A significant observational effort has been directed to investigate the nature of the so-called dark energy. In this dissertation we derive constraints on dark energy models using three different observable: measurements of the Hubble rate H(z) (compiled by Meng et al. in 2015.); distance modulus of 580 Supernovae Type Ia (Union catalog Compilation 2.1, 2011); and the observations of baryon acoustic oscilations (BAO) and the cosmic microwave background (CMB) by using the so-called CMB/BAO of six peaks of BAO (a peak determined through the Survey 6dFGS data, two through the SDSS and three through WiggleZ). The statistical analysis used was the method of the χ2 minimum (marginalized or minimized over h whenever possible) to link the cosmological parameter: m, ω and δω0. These tests were applied in two parameterization of the parameter ω of the equation of state of dark energy, p = ωρ (here, p is the pressure and ρ is the component of energy density). In one, ω is considered constant and less than -1/3, known as XCDM model; in the other the parameter of state equantion varies with the redshift, where we the call model GS. This last model is based on arguments that arise from the theory of cosmological inflation. For comparison it was also made the analysis of model CDM. Comparison of cosmological models with different observations lead to different optimal settings. Thus, to classify the observational viability of different theoretical models we use two criteria information, the Bayesian information criterion (BIC) and the Akaike information criteria (AIC). The Fisher matrix tool was incorporated into our testing to provide us with the uncertainty of the parameters of each theoretical model. We found that the complementarity of tests is necessary inorder we do not have degenerate parametric spaces. Making the minimization process we found (68%), for the Model XCDM the best fit parameters are m = 0.28 ± 0, 012 and ωX = −1.01 ± 0, 052. While for Model GS the best settings are m = 0.28 ± 0, 011 and δω0 = 0.00 ± 0, 059. Performing a marginalization we found (68%), for the Model XCDM the best fit parameters are m = 0.28 ± 0, 012 and ωX = −1.01 ± 0, 052. While for Model GS the best settings are M = 0.28 ± 0, 011 and δω0 = 0.00 ± 0, 059.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A significant observational effort has been directed to investigate the nature of the so-called dark energy. In this dissertation we derive constraints on dark energy models using three different observable: measurements of the Hubble rate H(z) (compiled by Meng et al. in 2015.); distance modulus of 580 Supernovae Type Ia (Union catalog Compilation 2.1, 2011); and the observations of baryon acoustic oscilations (BAO) and the cosmic microwave background (CMB) by using the so-called CMB/BAO of six peaks of BAO (a peak determined through the Survey 6dFGS data, two through the SDSS and three through WiggleZ). The statistical analysis used was the method of the χ2 minimum (marginalized or minimized over h whenever possible) to link the cosmological parameter: m, ω and δω0. These tests were applied in two parameterization of the parameter ω of the equation of state of dark energy, p = ωρ (here, p is the pressure and ρ is the component of energy density). In one, ω is considered constant and less than -1/3, known as XCDM model; in the other the parameter of state equantion varies with the redshift, where we the call model GS. This last model is based on arguments that arise from the theory of cosmological inflation. For comparison it was also made the analysis of model CDM. Comparison of cosmological models with different observations lead to different optimal settings. Thus, to classify the observational viability of different theoretical models we use two criteria information, the Bayesian information criterion (BIC) and the Akaike information criteria (AIC). The Fisher matrix tool was incorporated into our testing to provide us with the uncertainty of the parameters of each theoretical model. We found that the complementarity of tests is necessary inorder we do not have degenerate parametric spaces. Making the minimization process we found (68%), for the Model XCDM the best fit parameters are m = 0.28 ± 0, 012 and ωX = −1.01 ± 0, 052. While for Model GS the best settings are m = 0.28 ± 0, 011 and δω0 = 0.00 ± 0, 059. Performing a marginalization we found (68%), for the Model XCDM the best fit parameters are m = 0.28 ± 0, 012 and ωX = −1.01 ± 0, 052. While for Model GS the best settings are M = 0.28 ± 0, 011 and δω0 = 0.00 ± 0, 059.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Survival models deals with the modelling of time to event data. In certain situations, a share of the population can no longer be subjected to the event occurrence. In this context, the cure fraction models emerged. Among the models that incorporate a fraction of cured one of the most known is the promotion time model. In the present study we discuss hypothesis testing in the promotion time model with Weibull distribution for the failure times of susceptible individuals. Hypothesis testing in this model may be performed based on likelihood ratio, gradient, score or Wald statistics. The critical values are obtained from asymptotic approximations, which may result in size distortions in nite sample sizes. This study proposes bootstrap corrections to the aforementioned tests and Bartlett bootstrap to the likelihood ratio statistic in Weibull promotion time model. Using Monte Carlo simulations we compared the nite sample performances of the proposed corrections in contrast with the usual tests. The numerical evidence favors the proposed corrected tests. At the end of the work an empirical application is presented.