99 resultados para Fracturação hidráulica


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigates a new treatment system of wastewater by anaerobic and aerobic biological filters for nitrogen modification. The main objective of this study was evaluate, on a pilot scale, quantitatively and qualitatively the bacterian nitrifying community in a experimental sewage treatment system made by aerobics biological filters in series, in search of figure out the dynamic of nitrogen modification process. It was collected and laboratorial analysed microbiologically, regarding NMP of Nitrosomonas e Nitrobacter, and physical-chemically considering nitrogen sequence. We conclude that: the association in aerobic biological filters under nutrition controlled conditions and oxygen level allows the appearance of bacterian community responsible for the nitrogen modification; the method used, despite its limitations, provided the selection of autotrophic nitrifying microorganisms, allowing the identification of Nitrosomonas and Nitrobacter; the flow direction tested in the experimental unit did not affect the nitrifying bacterial community, certainly because they were kept drowned and did not occur flow speed that could breake the formed biomass; the nitrification process happened in aerated biological filters in all phases of the research, comproved by microbiological tests; in the third phase of the research the increase of the oxygen rate was significant for the nitrificant bacterian community in the aerate biological filters, allowing its growth, occurring relation between the efficiency of nitrification system and the quantity of organisms responsible for this process; the conduit used in aerated biological filters showed satisfactory performance support material to the nitrifying bacteria development

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Only 32% of the population of Natal is attended by sewage, while the remaining population use pits and septic tanks. The characterization of the contents of septic tanks and pits contributes to the performance of such system and may guide the decision on treatment of these contents. The main of this research is to characterize the contents of interior residential pits and septic tanks in the greater Natal, with the following specific goals: to develop and manufacture a sampler capable of collecting a representative sample of the entire column (the surface scum, the clarified liquid and sludge bottom); to compare the contents of the tanks with the pits; to compare the contents of the septage from vacuum trucks; to relate the composition content with socioeconomic characteristics of households; to compare the content in both chambers of the septic tanks in series; to assess the situation of the content before and six months after the cleanness; and ultimately propose a pilot scale plant for treatment of septage. Once the sampler was developed, samples were collected within 14 septic tanks and 10 pits in many districts of Natal. Medians of the 24 systems were obtained: temperature, pH, conductivity, oil and grease, total solids, total suspended solids and sediments of 28.0 °C, 6.95; 882 mS/cm, 75.2 mg/L; 10,169 mg/L, 6,509 mg/L and 175 mL/L respectively; 111.0 mgN/L for ammonia, 130.5 mgN/ L for organic nitrogen, 0.2 mgN/L for nitrite, 0.4 mg/L for nitrate; 8935 mgO2/L for COD, 29.2 mgP/L for total phosphorus, thermotolerant coliforms from 9.95 E +06 CFU/100mL helminth eggs and 9.2 eggs/L with a maximum concentration of 688 eggs/L and minimum of 0 eggs/L. Medians of organic nitrogen and TKN were significantly different between groups of tanks and pits. The systems with cleanness gap from 11 and 20 years presented the higher concentrations for most variables. The effluent from the toilets and bathrooms participate more effectively in contributing fractions of solids, alkalinity, nitrogen, COD, total phosphorus, thermotolerant coliforms and helminth eggs. The systems used by socioeconomics class with income from R$ 3,700.00 to R$ 7,600.00, presented higher concentrations for COD, nitrogen, solids and helminth eggs. The first of the two chambers had always presented higher concentrations over the second compartment. The analysis of variance for most variables, showed that the values of septic tanks, pits and septage from vacuum trucks belong to the same group. In the samples taken after cleanness, the median of pH and temperature increased, while alkalinity, COD, organic nitrogen, total phosphorus, ammonia and helminth eggs decreased. The oils and greases and thermotolerant coliforms had slightly varied due to the continuous release of sewage into the systems that maintained their steady state concentrations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the contemporary world to the deterioration of semi-arid areas of the planet has been the focus of media attention and the scientific community. Brazil has a semiarid, considered the most problematic of the world, either by pressure from physical factors, whether as a result of misguided public policies, has over time been suffering from the consequences of a deterioration that expands over the years. Methodologies, that amidst the problems of semi-arid, come against the deteriorating local, have a good chance to be reapplied in other contexts around the world. This research, based on methodological model for analyzing environmental deterioration, introduced and examined the applicability of the methodology in the semi-arid region of Rio Grande do Norte - Brazil. Although the results provide guidelines for the introduction of underground dams, the application of the methodology was ineffective, given the high rates of forest cover that gave low values for the physical diagnosis conservationist

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although the good performance in organic matter and suspended solids removal, the anaerobic reactors are unable to remove ammonia nitrogen from sewage, which makes indispensable to include a step of post-treatment for removal of ammonia or nitrate as necessary. This paper presents the performance of a new variant technology, where the nitrification unit, preceded by anaerobic units, is a submerged aerated biological filter, without continuous sludge discharge in their daily operation. The oxygenation system is very simple and inexpensive, consisting of perforated hoses and compressors. The anaerobic reactors are a septic tank with two chambers followed (8.82 m³) and two parallel anaerobic filters (36 m³ each) filled with ceramic bricks and conics plastic parts. Both followed aerated filters were filled with cut corrugated conduit. The study evaluated the behavior of the system with constant domestic sewage flow (10 m³/d) and different aeration conditions, are these: stage 01, when applied air flow of 0.01 m³ air/min in both aerated filter; stage 02, remained in the initial air flow rate in the second aerated filter and increased at the first to 0.05 m³ air/min; at last, at last, in stage 03, the air flow rate of first aerated filter was 0.10 m³ air/min and on the second remained at 0.01 m³ air/min. The filter FA1 received load of 0.41 kg COD/m³.d, 0.37 kg COD/m³.d and 0.26 kg COD/m³.d on phases 01, 02 and 03, respectively. The FA2 received loads of 0.25 kg COD/m³.d, 0.18 kg COD/m³.d and 0.14 kg COD/m³.d on phases 01, 02 and 03, respectively. During stage 01, were found the following results: 98% removals of BODtotal and 92% of CODtotal, with effluent presenting 9 mg/L of BODtotal final average and 53 mg/L of CODtotal average; suspended solids removals of 93%, with a mean concentration of 10 mg/L in the final effluent; 47% reduction of ammonia of FA2 to FAN 's, presenting average of 28 mg NNH3/ L of ammonia in the effluent with; the dissolved oxygen levels always remained around 2.0 mg/L. During stage 02, were found removals of 97% and 95% to BODtotal and suspended solids, respectively, with average final concentrations of 8 and 7 mg/L, respectively; was removed 60% of ammonia, whose final concentration was 16.3 mg NNH3/ L, and nitrate was increased to a final average concentration of 16.55 mg N-NO3/L. Finally, the stage 03 provided 6 mg/L of DBOtotal (98% removal) and 23 mg/L of CODtotal (95% removal) of final effluent concentrations average. At this stage was identified the higher ammonia oxidation (86%), with final effluent showing average concentration of 6.1 mg N-NH3/L, reaching a minimum of 1.70 mg N-NH3/L. In some moments, during stage 03, there was a moderate denitrification process in the last aerated filter. The average turbidity in the effluent showed around 1.5 NTU, proving the good biomass physical stability. Therefore, the results demonstrate the submerged biological filters potential, filled with high void ratio material (98%), and aerated with hoses and compressor adoption, in the carbonaceous and nitrogenous matter oxidation, also generating an effluent with low concentration of solids

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Anthropic disturbances in watersheds, such as inappropriate building development, disorderly land occupation and unplanned land use, may strengthen the sediment yield and the inflow into the estuary, leading to siltation, changes in the reach channel conformation, and ecosystem/water quality problems. Faced with such context, this study aims to assess the applicability of SWAT model to estimate, even in a preliminary way, the sediment yield distribution along the Potengi River watershed, as well as its contribution to the estuary. Furthermore, an assessment of its erosion susceptibility was used for comparison. The susceptibility map was developed by overlaying rainfall erosivity, soil erodibility, the slope of the terrain and land cover. In order to overlap these maps, a multi-criteria analysis through AHP method was applied. The SWAT was run using a five year period (1997-2001), considering three different scenarios based on different sorts of human interference: a) agriculture; b) pasture; and c) no interference (background). Results were analyzed in terms of surface runoff, sediment yield and their propagation along each river section, so that it was possible to find that the regions in the extreme west of the watershed and in the downstream portions returned higher values of sediment yield, reaching respectively 2.8 e 5.1 ton/ha.year, whereas central areas, which were less susceptible, returned the lowest values, never more than 0.7 ton/ha.ano. It was also noticed that in the west sub-watersheds, where one can observe the headwaters, sediment yield was naturally forced by high declivity and weak soils. In another hand, results suggest that the eastern part would not contribute to the sediment inflow into the estuary in a significant way, and the larger part of the sediment yield in that place is due to anthropic activities. For the central region, the analysis of sediment propagation indicates deposition predominance in opposition to transport. Thus, it s not expected that isolated rain storms occurring in the upstream river portions would significantly provide the estuary with sediment. Because the model calibration process hasn t been done yet, it becomes essential to emphasize that values presented here as results should not be applied for pratical aims. Even so, this work warns about the risks of a growth in the alteration of natural land cover, mainly in areas closer to the headwaters and in the downstream Potengi River

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Digital Elevation Models (DEM) are numerical representations of a portion of the earth surface. Among several factors which affect the quality of a DEM, it should be emphasized the attention on the input data and the choice of the interpolating algorithm. On the other hand, several numerical models are used nowadays to characterize nearshore hydrodynamics and morphological changes in coastal areas, whose validation is based on field data collection. Independent on the complexity of the physical processes which are modeled, little attention has been given to the intrinsic bathymetric interpolation built within the numerical models of the specific application. Therefore, this study aims to investigate and to quantify the influence of the bathymetry, as obtained by a DEM, on the hydrodynamic circulation model at a coastal stretch, off the coast of the State of Rio Grande do Norte, Northeast Brazil. This coastal region is characterized by strong hydrodynamic and littoral processes, resulting in a very dynamic morphology with shallow coastal bathymetry. Important economic activities, such as oil exploitation and production, fisheries, salt ponds, shrimp farms and tourism, also bring impacts upon the local ecosystems and influence themselves the local hydrodynamics. This fact makes the region one of the most important for the development of the State, but also enhances the possibility of serious environmental accidents. As a hydrodynamic model, SisBaHiA® - Environmental Hydrodynamics System ( Sistema Básico de Hidrodinâmica Ambiental ) was chosen, for it has been successfully employed at several locations along the Brazilian coast. This model was developed at the Coastal and Oceanographical Engineering Group of the Ocean Engineering Program at the Federal University of Rio de Janeiro. Several interpolating methods were tested for the construction of the DEM, namely Natural Neighbor, Kriging, Triangulation with Linear Interpolation, Inverse Distance to a Power, Nearest Neighbor, and Minimum Curvature, all implemented within the software Surfer®. The bathymetry which was used as reference for the DEM was obtained from nautical charts provided by the Brazilian Hydrographic Service of the Brazilian Navy and from a field survey conducted in 2005. Changes in flow velocity and free surface elevation were evaluated under three aspects: a spatial vision along three profiles perpendicular to the coast and one profile longitudinal to the coast as shown; a temporal vision from three central nodes of the grid during 30 days; a hodograph analysis of components of speed in U and V, by different tidal cycles. Small, but negligible, variations in sea surface elevation were identified. However, the differences in flow and direction of velocities were significant, depending on the DEM

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Provide data and information on watershed becomes important since the knowledge of their physical characteristics, land use, etcetera, allows for better planning and sustainable use of economically, socially and environmentally in this area. The investigation of the physical environment has been commonly given with the use of geoprocessing, which has proved a very efficient tool. Within this context, this research aims at analyzing the river basin Punaú (located in the cities of Touros, Rio do Fogo and Pureza, state of Rio Grande do Norte) in several aspects, using geoprocessing as a tool of work, to provide information about the entire watershed. Specifically, this study aimed to update pre-existing maps, such as geological, geomorphological and land use, generating map of environmental vulnerability, under the aspect of erosion susceptibility of the area, generating map of legal incompatibility, identifying areas that are already being employed in breach of environmental legislation; propose solutions to the occupation of the river basin Punaú, focused on environmental planning. The methodology was based on the use of geoprocessing tools for data analysis and to make maps of legal incompatibility and environmental vulnerability. For the first map was taken into account the environmental legislation regarding the protection of watersheds. For the vulnerability analysis, the generated map was the result of crossing the maps of geology, geomorphology, soils and land use, having been assigned weights to different attributes of thematic maps, generating a map of environmental vulnerability in relation to susceptibility to erosion. The analysis results indicate that agriculture is the most significant activity in the basin, in total occupied area, which confers a high degree of environmental vulnerability in most of the basin, and some agricultural areas eventually develop in a manner inconsistent with Brazilian environmental legislation. It is proposed to consider deploying a measure of revitalization of the watershed in more critical areas and conservation through mitigation measures on the causes of environmental degradation, such as protection of water sources, protection and restoration of riparian vegetation, protection of permanent preservation areas, containment of erosion processes in general, and others listed or not in specific laws, and even the establishment of a committee of basins in the area

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This research study deals with the production and distribution of drinking water with quality and safety in order to meet the needs of the Man. Points out the limitations of the methodology for assessing water quality in use today. Approaches the recommendations of the World Health Organization (WHO) for adoption, by the companies responsible for producing and distributing water, of assessment methodologies and risk management (HACCP), in order to ensure the quality and safety of water drinking. Suggests strategies for implementing the plan for water safety plan. Uses the process of water production, composed by Maxaranguape river basin, the water treatment plant and distribution system, which is part of the Plan for Expansion of the Supply System of Natal, as case study. The results, it was possible to devise strategies for implementation of the Water Safety Plan (WSP), which comprises the following steps: a) a preliminary stage. b) assessment system. c) process monitoring. d) management plan and e) validation and verification of the PSA. At each stage are included actions for its implementation. The implementation of the PSA shows a new type of water production, in which the fountain as a whole (watershed and point of capture), the Water Treatment Plant (WTP) and distribution, shall compose the production process, over which to build quality and safety of the final product (drinking water)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Eutrophication is a growing process present in the water sources located in the northeast of Brazil. Among the main consequences of these changes in trophic levels of a water source, stands out adding complexity to the treatment to achieve water standards. By these considerations, this study aimed to define, on a laboratory scale, products and operational conditions to be applied in the processing steps using raw water from Gargalheiras dam, RN, Brazil. The dam mentioned shows a high number of cyanobacteria, with a concentration of cells / ml higher than that established by Decree No. 518/04 MS. The same source was also considered by the state environmental agency in 2009 as hypereutrophic. The static tests developed in this research simulated direct filtration (laboratory filters) and pre-oxidation with chlorine and powdered activated carbon adsorption. The research included the evaluation of the coagulants aluminum hydrochloride (HCA) and alum (SA). The development of the research investigated the conditions for rapid mixing, the dosages of coagulants and pHs of coagulation by the drawing of diagrams. The interference of filtration rate and particle size of filtering means were evaluated as samples and the time of contact were tested with chlorine and activated carbon. By the results of the characterization of the raw water source it was possible to identify the presence of a high pH (7.34). The true color was significant (29 uH) in relation to the apparent color and turbidity (66 uH and 13.60 NTU), reflecting in the measurement of organic matter: MON (8.41 mg.L-1) and Abs254 (0.065 cm-1). The optimization of quick mix set time of 17", the speed gradient of 700 s-1 in the coagulation with HCA and the time of 20" with speed gradient of 800 s-1 for SA. The smaller particle sizes of sand filtering means helped the treatment and the variation in filtration rate did not affect significantly the efficiency of the process. The evaluation of the processing steps found adjustment in standard color and turbidity of the Decree nº 518/04 MS, taking in consideration the average values found in raw water. In the treatment using the HCA for direct filtration the palatable pattern based on the apparent color can be achieved with a dose of 25 mg L-1. With the addition of pre-oxidation step, the standard result was achieved with a reduced dose for 12 mgHCA.L-1. The turbidity standard for water was obtained by direct filtration when the dose exceeds 25 mg L-1 of HCA. With pre-oxidation step there is the possibility of reducing the dose to 20 mg L-1.The addition of CAP adsorption, promoted drinking water for both parameters, with even lower dosage, 13 mg L-1 of HCA. With coagulation using SA removal required for the parameter of apparent color it was achieved with pre-oxidation and 22 mgSA.L-1. Despite the satisfactory results of treatment with the alum, it was not possible to provide water with turbidity less than 1.00 NTU even with the use of all stages of treatment

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Serido is a region of northeastern Brazil highlighted by its problems related to water scarcity because of its semi-arid region, large rates of evaporation and rainfall irregular and scarce. Thus, the underground dams, become a strategically important resource with a simple and inexpensive technique for storage of water. They act in a positive way in the development of inland cities that suffer from drought, because in addition to exercise a great improvement in the social role of these families, can enjoy the type of soil (silt) and provides water for both irrigation and for human consumption throughout the year. Is therefore essential to its monitoring and studies to assess its effectiveness in accordance with its purposes, along with their wells Amazons, as can occur in conditions of physical degradation, chemical and microbiological appropriate, according to the Ordinance No 518/04 Ministry of Health, however, the proposed work aims to analyze the underground dams in the municipality of Sierra Negra North-RN (semi-arid region) as to their uses and their influences on the quality and quantity of water in periods of drought and rain. Analyzing monthly these parameters: determination of pH, conductivity, calcium, magnesium, sodium, potassium, chloride, sulfate, RAS (sodium adsorption ratio), turbidity, total iron, nitrite, nitrate, total dissolved solids (STD), bicarbonate (HCO3), fecal coliform and pesticides compared to the standards allowed by the Ordinance in force for quality for human consumption. While at the risk of salinity and sodicity on the model proposed by the United Salinity Laboratory (USSL). Although efficient, it was found that results varied annually on water quality which may influence their specific uses, whether or irrigation water supply in the city

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aims to assess the potential for industrial reuse of textile wastewater, after passing through a physical and chemical pretreatment, into denim washing wet processing operations in an industrial textile laundry, with no need for complementary treatments and dilutions. The methodology and evaluation of the proposed tests were based on the production techniques used in the company and upgraded for the experiments tested. The characterization of the treated effluent for 16 selected parameters and the development of a monitoring able to tailor the treated effluent for final disposal in accordance with current legislation was essential for the initiation of testing for reuse. The parameters color, turbidity, SS and pH used were satisfactory as control variables and presents simple determination methods. The denim quality variables considered were: color, odor, appearance and soft handle. The tests were started on a pilot scale following complexity factors attributed to the processes, in denim fabric and jeans, which demonstrated the possibility of reuse, because there was no interference in the processes and at quality of the tested product. Industrial scale tests were initiated by a step control that confirmed the methodology efficiency applied to identify the possibility of reuse by tests that precede each recipe to be processed. 556 replicates were performed in production scale for 47 different recipes of denim washing. The percentage of water reuse was 100% for all processes and repetitions performed after the initial adjustment testing phase. All the jeans were framed with the highest quality for internal control and marketed, being accepted by contractors. The full-scale use of treated wastewater, supported by monitoring and evaluation and control methodology suggested in this study, proved to be valid in textile production, not given any negative impact to the quality the produced jeans under the presented conditions. It is believed that this methodology can be extrapolated to other laundries to determine the possibility of reuse in denim washing wet processing with the necessary modifications to each company.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study that resulted in this dissertation was developed at OU RNCE PETROBRAS, in Natal, which implemented a project of rational use and reuse of water, including use of wastewater from a Sewage Treatment Plant (STP) already in place, diluted with water from own wells for irrigation of green area of the building complex corporate enterprise. Establish a methodology that can serve as guidelines for future projects controlled reuse of water like this was the objective of this research. Been proposed, implemented and evaluated three instruments of sanitary and environmental control: 1) adaptation of sewage treatment plant and quality control of the treated effluent 2) analysis of soil-nutrient interaction in the irrigated area, 3) knowledge of the local hydrogeology, especially with regard to the direction of flow of the aquifer and location of collection wells of Companhia de Águas e Esgotos do Rio Grande do Norte (CAERN) situated in the surroundings. These instruments have proven sufficient and appropriate to ensure the levels of sanitary and environmental control proposed and studied, which were: a) control of water quality off the STP and the output of the irrigation reservoir, b) control of water quality sub surface soil and assessment of progress on soil composition, c) assessment of water quality in the aquifer. For this, we must: 1) establishing the monitoring plan of the STP and its effluent quality sampling points and defining the parameters of analysis, improve the functioning of that identifying the adequacy of flow and screening as the main factors of operational control, and increase the efficiency of the station to a relatively low cost, using additional filters, 2) propose, implement and adapt simple collectors to assess the quality of water percolating into the soil of the irrigated area, 3) determine the direction of groundwater flow in the area study and select the wells for monitoring of the aquifer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The detention and infiltration ponds of urban drainage system has function to protect the population from undesirable effects of floods. In general these ponds are not completly used and it potential is wasted. As it are disseminated at different places at cities it can reduce costs with water transport and permit water preservation of best quality. Some it utilities includes use in green areas irrigation, industrial among than cooling towers and boiler, soil compaction, cleaning urban road, pisciculture and fire fighting system. The quality these water is influenced by anauthorized sewage in the drainage system. This study was performed in six detention and infiltration ponds at drainage system of Natal, which aim was to verify the non-portable use these ponds on urban environment. As indirect aim would to incentive the water utilization these ponds as a water source to another uses in urban environment. These ponds represents the characteristics of detention and infiltration of Natal city and consequently of Brazil. As the water quality, the ponds presents following characteristics: three has apparently good quality, other showed intermediate condition and two had water polluted. Were performed twenty sample in each ponds and the following parameters assessed: pH, temperature, dissolved oxygen, turbidity, electrical conductivity, coliform thermotolerant, ammonia, organic nitrogen, TKN, nitrate, total phosphorus and alkalinity, bicarbonate, chloride, total hardness, calcium and magnesium hardness, total solids, TSS, TDS, COD and SAR°. To utilization on pisciculture we recommend use in ponds which presents the best quality. Only one pond presented higher pollutants and it not being appropriated for use in cooling tower. The content of solids suspension restricted the water use in all ponds in boilers. As water use in soil compaction, cleaning urban road and fire fighting system the water from these ponds are not appropriated. However, the recommended limits from literature are to domestic sewage, due to this, the parameters are restrictive to diminish the sanitary risk that could be offered with it utilization. The infiltration velocity of water these assessed ponds restrict a moderato use, however the effects are potentiated only in soil less sandy, which not occur in Natal. It is recommend the unrestricted irrigation utilization in ponds with best quality of water, and a restricted irrigation to ponds with worst quality of water. As load of pollutants, it is recommended a complementary treatment in those ponds whit higher load to diminish sanitary risks. In only one pond was found one helminth eggs and due to the convention formula of results, it was found for all ponds less than 1 helminth/liter eggs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stabilization pond system consisting in more sewage treatment used in Rio Grande do Norte (RN), Brazil, representing about 90% of all systems. Fecal bacteria are removed mainly facultative ponds and in maturation ponds. Many factors influence bacterial decay, such as the levels of pH and DO, temperature, light intensity, HDT and nutrient availability. The bacterial decay rate (Kb) is calculated considering many variables, but the hydraulic regime is a significant influence for microorganisms removal, and the dispersed flow which best characterizes a stabilization pond. However, some authors developed equations for the Kb accordant plug flow and complete mixing. This research study aimed to evaluate the bacterial decay of fecal coliform and Enterococcus sp. in stabilization ponds designed to treat domestic sewage, full-scale, in RN. All systems have assessed pretreatment, a facultative pond (LF) followed by two maturation (LM1 and LM2). The parameters availed were: temperature, pH, DO, BOD5, COD, fecal coliform, Enterococcus sp., Chlorophyll a, total suspended solids, fixed and volatile. In general, there were not significant differences for pH, DO and temperature in the ponds, except for the new systems, since they have low flow and hydraulic loads. The removal of organic matter in the ponds was low, about 70%, and nearly all are overloaded organic and operational problems. The bacterial removals were low, with average 96% for LF for fecal coliform, and 98% for Enterococcus sp.; LM1 were in itself a removal for fecal coliform about 71%, and 81% for Enterococcus sp.; LM2 have efficiency of 69% for fecal coliform, and 68% for Enterococcus sp. The equation proposed by Von Sperling (1999), according to the dispersed flow regime, generated empirical values of Kb more approximate to calculated values of Kb. On average, the calculated Kb to coliforms in the LF was 0.31 d-1, and for both maturation ponds were 0.35 d-1. For Enterococcus sp. the average was 0.40 d-1 for LF, 0.55 d-1 for LM1, and 0.58 d-1 for LM2. These results also showed that the Kb obtained in full-scale systems are smaller than those found in pilot-scale ponds. Moreover, one can say that the equation proposed by Marais (1974), according to the complete-mix regime, overestimates Kb. Actual results of Kb indicated that fecal coliforms are more resistant to adverse conditions present in stabilization ponds than Enterococcus sp., therefore, an indicator of microbiological safety and efficiency. The factors significant interventions in the rate of bacterial decay were concentrations of COD, the organic loading and HDT. The few Kb relationship between pH, DO and temperature were not significant. Finally, we conclude that it s essential to correct operation and maintenance, for not performing these activities is one of the main factors contributing to low rates of bacterial decay.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The groundwater quality has been compromised as a result of the intensification of human activities over the years. Groundwater contamination by nitrate is one of the effects of this degradation, a socio-environmental problem that affects many regions of the world and particular the city of Natal (RN). Developing techniques for nitrate removal in water is intended to eliminate or reduce the concentration of this compound, and those that involve biological processes have produced economic and environmental advantages. This study proposes a technology for biological removal of nitrate in water supply for humans, using the endocarp s coconut as a carbon source and bacteria support. The experiments were performed in pilot scale anoxic, testing different areas of the substrate surface. Results showed high rates nitrate removal during the monitoring period, noting the occurrence of denitrification after the beginning of system operation. The best performance was achieved in the treatment system containing substrate surface area increased, indicating that the decrease in the endocarp size contributed to increased bacterial activity, improving the ability to remove nitrate. About the quality analyzed aspects of water, it was found that the proposed technology has the potential water use for human consumption