40 resultados para DENTURE STOMATITIS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate the planning and quality of plaster models for fabricati on of removable parti al dentures received from three commercial prosthodonti c laboratories located in the city of João Pessoa, PB, Brazil, which perform the casting procedures in their facilities. Methods: Forty 40 plaster models were photographed per laboratory, totalizing 120 models. The evaluation was performed using two questi onnaires, one designed for the dental prosthesis technicians, and another applied by the investigator for the visual evaluati on of the models. Data were analyzed using the SPSS soft ware version 13.0. Results: Ninety-two (76.7%) models did not present planning. In addition, no model presented references of insertion plane or guide pins. Calculati on of the mouth preparati on index (MPI) to evaluate the distribution of the oclusal and cingulum abutments or rests showed that 86 (71.7%) models were classifi ed as poor, 23 (19.2%) models as good and only 11 (9,.2%) models as acceptable. Defects were found in 102 (85%) models. Conclusion: The prosthodontists are not preparing the mouth of their pati ents, neglecti ng the planning of removable partial dentures, and passing this responsibility to the dental prosthesis technicians. In addition, the quality of the models sent to the laboratories was unsatisfactory.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An appropriate design of a prosthetic rehabilitation should not impute the restoration of occlusal vertical dimension (OVD) to new prostheses, at the risk of the patient does not adapt to a new condition, since a certain amount of time is often necessary for adaptation to a new OVD. This article performed prosthetic rehabilitation with an overlay provisional removable partial denture prior to definitive treatment because the patient showed a considerable decrease in the OVD. Three techniques for OVD determination were used. It is possible to conclude that the use of interim removable partial dentures is of great importance at the beginning of the rehabilitation treatment in order to adapt the patient to a new occlusal condition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An appropriate design of a prosthetic rehabilitation should not impute the restoration of occlusal vertical dimension (OVD) to new prostheses, at the risk of the patient does not adapt to a new condition, since a certain amount of time is often necessary for adaptation to a new OVD. This article performed prosthetic rehabilitation with an overlay provisional removable partial denture prior to definitive treatment because the patient showed a considerable decrease in the OVD. Three techniques for OVD determination were used. It is possible to conclude that the use of interim removable partial dentures is of great importance at the beginning of the rehabilitation treatment in order to adapt the patient to a new occlusal condition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To perform a long-term clinical evaluation of the periodontium of removable parti al denture (RPD) wearers, comparing the direct pillar teeth of tooth-supported and toothtissue supported RPDs. Method: Fifty patients with mean age of 45 years were enrolled in the study. The individuals were examined by a single examiner at the moment of denture installation and after 3, 6, 9 and 12 months. In each exam, the following parameters were verified: gingival recession (GR), probing depth (PD), plaque index (PI), gingival index (GI) e amount kerati nized mucosa (KM). All patients received oral hygiene instructions and prophylaxis and, when necessary, scaling and root planing. An analysis from the confidence interval was done to evaluate the endpoints regarding the type of denture in the direct pillar group. Results: The tooth-tissue supported dentures showed significantly higher GR, GI and PI values, and significantly lower KM values. Over time, neither of the types of denture presented statistically significant difference from the initial to the final examination for the parameters GR, PD, KM and GI, while the PI was significant only for the tooth-supported dentures. Conclusion: Pillar teeth adjacent to free ends presented a less favorable periodontal conditi on than the pillar teeth adjacent to intercalated spaces. However, the use of RPD did not aggravate the initial condition, after a follow-up period of 12 months. The findings of the study indicate that, within 1 year, there were no significant differences between the direct pillars of the toothsupported and tooth-ti ssue supported dentures, and suggest the need of professional follow up for a longer period.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To perform a long-term clinical evaluation of the periodontium of removable parti al denture (RPD) wearers, comparing the direct pillar teeth of tooth-supported and toothtissue supported RPDs. Method: Fifty patients with mean age of 45 years were enrolled in the study. The individuals were examined by a single examiner at the moment of denture installation and after 3, 6, 9 and 12 months. In each exam, the following parameters were verified: gingival recession (GR), probing depth (PD), plaque index (PI), gingival index (GI) e amount kerati nized mucosa (KM). All patients received oral hygiene instructions and prophylaxis and, when necessary, scaling and root planing. An analysis from the confidence interval was done to evaluate the endpoints regarding the type of denture in the direct pillar group. Results: The tooth-tissue supported dentures showed significantly higher GR, GI and PI values, and significantly lower KM values. Over time, neither of the types of denture presented statistically significant difference from the initial to the final examination for the parameters GR, PD, KM and GI, while the PI was significant only for the tooth-supported dentures. Conclusion: Pillar teeth adjacent to free ends presented a less favorable periodontal conditi on than the pillar teeth adjacent to intercalated spaces. However, the use of RPD did not aggravate the initial condition, after a follow-up period of 12 months. The findings of the study indicate that, within 1 year, there were no significant differences between the direct pillars of the toothsupported and tooth-ti ssue supported dentures, and suggest the need of professional follow up for a longer period.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Due to properties such as excellent biocompatibility, high resistance to corrosion and low specific weight, titanium has been considered a material of great interest for Dentistry. It has been widely used in implants and orthognathic surgeries. Recently, titanium has been seen as a feasible alternative for the fabrication of removable partial denture frameworks, either in pure titanium (99.75%) or in titanium alloy forms (Ti-6Al-4V; Ti-6A1-7Nb). Based on a review of the literature, this work studied the use of titanium for the fabrication of removable partial denture frameworks, focusing on its advantages and disadvantages as well as its characteristics. It was concluded that the use of titanium is a convenient option for partially edentulous arches rehabilitation with quite satisfactory and promising clinical results. However, the need for highly-equipped laboratories increases the cost, preventing its large scale use.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Due to properties such as excellent biocompatibility, high resistance to corrosion and low specific weight, titanium has been considered a material of great interest for Dentistry. It has been widely used in implants and orthognathic surgeries. Recently, titanium has been seen as a feasible alternative for the fabrication of removable partial denture frameworks, either in pure titanium (99.75%) or in titanium alloy forms (Ti-6Al-4V; Ti-6A1-7Nb). Based on a review of the literature, this work studied the use of titanium for the fabrication of removable partial denture frameworks, focusing on its advantages and disadvantages as well as its characteristics. It was concluded that the use of titanium is a convenient option for partially edentulous arches rehabilitation with quite satisfactory and promising clinical results. However, the need for highly-equipped laboratories increases the cost, preventing its large scale use.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Traditional methods for dentures fabrication require a wide clinical and laboratory procedures; however, there is no scientific evidence that these methods can produce better results when compared with simplified methods. Aim: To evaluate the effectiveness of a simplified methods for denture fabrication, comparing it to the traditional one through masticatory efficiency and prosthesis quality. Method: A randomized controlled trial was conducted with 50 patients, 25 rehabilitated with prosthesis produced by traditional technique and 25 rehabilitated by a simplified technique. The masticatory efficiency was evaluated by colorimetric method, using chewing capsules. The quality of prosthesis was obtained using a reliable and reproducible instrument. Statistical analysis of the masticatory efficiency and quality of the prosthesis was obtained by the Mann-Whitney test. Results: 39 patients completed the study, 18 on traditional group and 21 on simplified group. There was no difference between groups for the masticatory efficiency (p = 0.835) and the quality of the prosthesis (p = 0672). The evaluation of the overall quality of the prosthesis according to oral conditions, demonstrated significant difference on the height of the mandibular ridges (p = 0.010) and mandibular muscle attachments (p = 0.039). Conclusion: Complete dentures fabricated by simplified method were considered effective from the point of view of masticatory efficiency and quality of prosthetics, with results similar to those made by the traditional method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Traditional methods for dentures fabrication require a wide clinical and laboratory procedures; however, there is no scientific evidence that these methods can produce better results when compared with simplified methods. Aim: To evaluate the effectiveness of a simplified methods for denture fabrication, comparing it to the traditional one through masticatory efficiency and prosthesis quality. Method: A randomized controlled trial was conducted with 50 patients, 25 rehabilitated with prosthesis produced by traditional technique and 25 rehabilitated by a simplified technique. The masticatory efficiency was evaluated by colorimetric method, using chewing capsules. The quality of prosthesis was obtained using a reliable and reproducible instrument. Statistical analysis of the masticatory efficiency and quality of the prosthesis was obtained by the Mann-Whitney test. Results: 39 patients completed the study, 18 on traditional group and 21 on simplified group. There was no difference between groups for the masticatory efficiency (p = 0.835) and the quality of the prosthesis (p = 0672). The evaluation of the overall quality of the prosthesis according to oral conditions, demonstrated significant difference on the height of the mandibular ridges (p = 0.010) and mandibular muscle attachments (p = 0.039). Conclusion: Complete dentures fabricated by simplified method were considered effective from the point of view of masticatory efficiency and quality of prosthetics, with results similar to those made by the traditional method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The cobalt-chromium alloy is extensively used in the Odontology for the confection of metallic scaffolding in partial removable denture. During the last few years, it has been reported an increasing number of premature imperfections, with a few months of prosthesis use. The manufacture of these components is made in prosthetic laboratories and normally involves recasting, using parts of casting alloy and parts of virgin alloy. Therefore, the objective of the present study was to analyze the mechanical properties of a commercial cobalt-chromium alloy of odontological use after successive recasting, searching information to guide the dental prosthesis laboratories in the correct manipulation of the cobalt-chromium alloy in the process of casting and the possible limits of recasting in the mechanical properties of this material. Seven sample groups were confectioned, each one containing five test bodies, divided in the following way: G1: casting only with virgin alloy; G2: casting with 50% of the alloy of the G1 + 50% of virgin alloy; G3: casting with 50% of the alloy of the G2 + 50% of virgin alloy; G4: casting with 50% of the alloy of the G3 + 50% of virgin alloy; G5: 50% of alloy of the G4 + 50% of virgin alloy; G6: 50% of alloy of the G5 + 50% of virgin alloy and finally the G7, only with recasting alloy. The modifications in the mechanical behavior of the alloy were evaluated. Moreover, it was carried the micro structural characterization of the material by optic and electronic scanning microscopy, and X ray diffraction.and fluorescence looking into the correlatation of the mechanical alterations with structural modifications of the material caused by successive recasting process. Generally the results showed alterations in the fracture energy of the alloy after successive recasting, resulting mainly of the increasing presence of pores and large voids, characteristic of the casting material. Thus, the interpretation of the results showed that the material did not reveal significant differences with respect to the tensile strength or elastic limit, as a function of successive recasting. The elastic modulus increased from the third recasting cycle on, indicating that the material can be recast only twice. The fracture energy of the material decreased, as the number of recasting cycles increased. With respect to the microhardness, the statistical analyses showedno significant differences. Electronic scanning microscopy revealed the presence of imperfections and defects, resulting of the recasting process. X ray diffraction and fluorescence did not show alterations in the composition of the alloy or the formation of crystalline phases between the analyzed groups. The optical micrographs showed an increasing number of voids and porosity as the material was recast. Therefore, the general conclusion of this study is that the successive recasting of of Co-Cr alloys affects the mechanical properties of the material, consequently leading to the failure of the prosthetic work. Based on the results, the best recommendadition is that the use of the material should be limited to two recasting cycles