64 resultados para Cícero As catilinárias


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Eutrophication is a growing process present in the water sources located in the northeast of Brazil. Among the main consequences of these changes in trophic levels of a water source, stands out adding complexity to the treatment to achieve water standards. By these considerations, this study aimed to define, on a laboratory scale, products and operational conditions to be applied in the processing steps using raw water from Gargalheiras dam, RN, Brazil. The dam mentioned shows a high number of cyanobacteria, with a concentration of cells / ml higher than that established by Decree No. 518/04 MS. The same source was also considered by the state environmental agency in 2009 as hypereutrophic. The static tests developed in this research simulated direct filtration (laboratory filters) and pre-oxidation with chlorine and powdered activated carbon adsorption. The research included the evaluation of the coagulants aluminum hydrochloride (HCA) and alum (SA). The development of the research investigated the conditions for rapid mixing, the dosages of coagulants and pHs of coagulation by the drawing of diagrams. The interference of filtration rate and particle size of filtering means were evaluated as samples and the time of contact were tested with chlorine and activated carbon. By the results of the characterization of the raw water source it was possible to identify the presence of a high pH (7.34). The true color was significant (29 uH) in relation to the apparent color and turbidity (66 uH and 13.60 NTU), reflecting in the measurement of organic matter: MON (8.41 mg.L-1) and Abs254 (0.065 cm-1). The optimization of quick mix set time of 17", the speed gradient of 700 s-1 in the coagulation with HCA and the time of 20" with speed gradient of 800 s-1 for SA. The smaller particle sizes of sand filtering means helped the treatment and the variation in filtration rate did not affect significantly the efficiency of the process. The evaluation of the processing steps found adjustment in standard color and turbidity of the Decree nº 518/04 MS, taking in consideration the average values found in raw water. In the treatment using the HCA for direct filtration the palatable pattern based on the apparent color can be achieved with a dose of 25 mg L-1. With the addition of pre-oxidation step, the standard result was achieved with a reduced dose for 12 mgHCA.L-1. The turbidity standard for water was obtained by direct filtration when the dose exceeds 25 mg L-1 of HCA. With pre-oxidation step there is the possibility of reducing the dose to 20 mg L-1.The addition of CAP adsorption, promoted drinking water for both parameters, with even lower dosage, 13 mg L-1 of HCA. With coagulation using SA removal required for the parameter of apparent color it was achieved with pre-oxidation and 22 mgSA.L-1. Despite the satisfactory results of treatment with the alum, it was not possible to provide water with turbidity less than 1.00 NTU even with the use of all stages of treatment

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aims to assess the potential for industrial reuse of textile wastewater, after passing through a physical and chemical pretreatment, into denim washing wet processing operations in an industrial textile laundry, with no need for complementary treatments and dilutions. The methodology and evaluation of the proposed tests were based on the production techniques used in the company and upgraded for the experiments tested. The characterization of the treated effluent for 16 selected parameters and the development of a monitoring able to tailor the treated effluent for final disposal in accordance with current legislation was essential for the initiation of testing for reuse. The parameters color, turbidity, SS and pH used were satisfactory as control variables and presents simple determination methods. The denim quality variables considered were: color, odor, appearance and soft handle. The tests were started on a pilot scale following complexity factors attributed to the processes, in denim fabric and jeans, which demonstrated the possibility of reuse, because there was no interference in the processes and at quality of the tested product. Industrial scale tests were initiated by a step control that confirmed the methodology efficiency applied to identify the possibility of reuse by tests that precede each recipe to be processed. 556 replicates were performed in production scale for 47 different recipes of denim washing. The percentage of water reuse was 100% for all processes and repetitions performed after the initial adjustment testing phase. All the jeans were framed with the highest quality for internal control and marketed, being accepted by contractors. The full-scale use of treated wastewater, supported by monitoring and evaluation and control methodology suggested in this study, proved to be valid in textile production, not given any negative impact to the quality the produced jeans under the presented conditions. It is believed that this methodology can be extrapolated to other laundries to determine the possibility of reuse in denim washing wet processing with the necessary modifications to each company.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study that resulted in this dissertation was developed at OU RNCE PETROBRAS, in Natal, which implemented a project of rational use and reuse of water, including use of wastewater from a Sewage Treatment Plant (STP) already in place, diluted with water from own wells for irrigation of green area of the building complex corporate enterprise. Establish a methodology that can serve as guidelines for future projects controlled reuse of water like this was the objective of this research. Been proposed, implemented and evaluated three instruments of sanitary and environmental control: 1) adaptation of sewage treatment plant and quality control of the treated effluent 2) analysis of soil-nutrient interaction in the irrigated area, 3) knowledge of the local hydrogeology, especially with regard to the direction of flow of the aquifer and location of collection wells of Companhia de Águas e Esgotos do Rio Grande do Norte (CAERN) situated in the surroundings. These instruments have proven sufficient and appropriate to ensure the levels of sanitary and environmental control proposed and studied, which were: a) control of water quality off the STP and the output of the irrigation reservoir, b) control of water quality sub surface soil and assessment of progress on soil composition, c) assessment of water quality in the aquifer. For this, we must: 1) establishing the monitoring plan of the STP and its effluent quality sampling points and defining the parameters of analysis, improve the functioning of that identifying the adequacy of flow and screening as the main factors of operational control, and increase the efficiency of the station to a relatively low cost, using additional filters, 2) propose, implement and adapt simple collectors to assess the quality of water percolating into the soil of the irrigated area, 3) determine the direction of groundwater flow in the area study and select the wells for monitoring of the aquifer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The detention and infiltration ponds of urban drainage system has function to protect the population from undesirable effects of floods. In general these ponds are not completly used and it potential is wasted. As it are disseminated at different places at cities it can reduce costs with water transport and permit water preservation of best quality. Some it utilities includes use in green areas irrigation, industrial among than cooling towers and boiler, soil compaction, cleaning urban road, pisciculture and fire fighting system. The quality these water is influenced by anauthorized sewage in the drainage system. This study was performed in six detention and infiltration ponds at drainage system of Natal, which aim was to verify the non-portable use these ponds on urban environment. As indirect aim would to incentive the water utilization these ponds as a water source to another uses in urban environment. These ponds represents the characteristics of detention and infiltration of Natal city and consequently of Brazil. As the water quality, the ponds presents following characteristics: three has apparently good quality, other showed intermediate condition and two had water polluted. Were performed twenty sample in each ponds and the following parameters assessed: pH, temperature, dissolved oxygen, turbidity, electrical conductivity, coliform thermotolerant, ammonia, organic nitrogen, TKN, nitrate, total phosphorus and alkalinity, bicarbonate, chloride, total hardness, calcium and magnesium hardness, total solids, TSS, TDS, COD and SAR°. To utilization on pisciculture we recommend use in ponds which presents the best quality. Only one pond presented higher pollutants and it not being appropriated for use in cooling tower. The content of solids suspension restricted the water use in all ponds in boilers. As water use in soil compaction, cleaning urban road and fire fighting system the water from these ponds are not appropriated. However, the recommended limits from literature are to domestic sewage, due to this, the parameters are restrictive to diminish the sanitary risk that could be offered with it utilization. The infiltration velocity of water these assessed ponds restrict a moderato use, however the effects are potentiated only in soil less sandy, which not occur in Natal. It is recommend the unrestricted irrigation utilization in ponds with best quality of water, and a restricted irrigation to ponds with worst quality of water. As load of pollutants, it is recommended a complementary treatment in those ponds whit higher load to diminish sanitary risks. In only one pond was found one helminth eggs and due to the convention formula of results, it was found for all ponds less than 1 helminth/liter eggs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stabilization pond system consisting in more sewage treatment used in Rio Grande do Norte (RN), Brazil, representing about 90% of all systems. Fecal bacteria are removed mainly facultative ponds and in maturation ponds. Many factors influence bacterial decay, such as the levels of pH and DO, temperature, light intensity, HDT and nutrient availability. The bacterial decay rate (Kb) is calculated considering many variables, but the hydraulic regime is a significant influence for microorganisms removal, and the dispersed flow which best characterizes a stabilization pond. However, some authors developed equations for the Kb accordant plug flow and complete mixing. This research study aimed to evaluate the bacterial decay of fecal coliform and Enterococcus sp. in stabilization ponds designed to treat domestic sewage, full-scale, in RN. All systems have assessed pretreatment, a facultative pond (LF) followed by two maturation (LM1 and LM2). The parameters availed were: temperature, pH, DO, BOD5, COD, fecal coliform, Enterococcus sp., Chlorophyll a, total suspended solids, fixed and volatile. In general, there were not significant differences for pH, DO and temperature in the ponds, except for the new systems, since they have low flow and hydraulic loads. The removal of organic matter in the ponds was low, about 70%, and nearly all are overloaded organic and operational problems. The bacterial removals were low, with average 96% for LF for fecal coliform, and 98% for Enterococcus sp.; LM1 were in itself a removal for fecal coliform about 71%, and 81% for Enterococcus sp.; LM2 have efficiency of 69% for fecal coliform, and 68% for Enterococcus sp. The equation proposed by Von Sperling (1999), according to the dispersed flow regime, generated empirical values of Kb more approximate to calculated values of Kb. On average, the calculated Kb to coliforms in the LF was 0.31 d-1, and for both maturation ponds were 0.35 d-1. For Enterococcus sp. the average was 0.40 d-1 for LF, 0.55 d-1 for LM1, and 0.58 d-1 for LM2. These results also showed that the Kb obtained in full-scale systems are smaller than those found in pilot-scale ponds. Moreover, one can say that the equation proposed by Marais (1974), according to the complete-mix regime, overestimates Kb. Actual results of Kb indicated that fecal coliforms are more resistant to adverse conditions present in stabilization ponds than Enterococcus sp., therefore, an indicator of microbiological safety and efficiency. The factors significant interventions in the rate of bacterial decay were concentrations of COD, the organic loading and HDT. The few Kb relationship between pH, DO and temperature were not significant. Finally, we conclude that it s essential to correct operation and maintenance, for not performing these activities is one of the main factors contributing to low rates of bacterial decay.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The improper disposal of nitrogen in receiving water courses causes problems such as toxicity to living beings through the consumption of oxygen to meet the nitrogen demand, eutrophication and nitrate contamination of aquifers. For this reason it is often necessary to be carried out complementary treatment of wastewater to eliminate or reduce the concentration of this compound in the wastewater. The objective of this study is to evaluate the biological removal of nitrogen compounds using submerged aerated and anoxic filters as post-treatment of an anaerobic system, with low cost and innovative technology, which in previous studies has shown high removal efficiency of organic matter and great potential biological nitrogen compounds removal. The simple design with perforated hoses for air distribution and filling with plastic parts proved to be very efficient in relation to organic matter removal and nitrification. The system presented, in the best stage, efficiency in converting ammonia to nitrate by 71%, and produced a final effluent concentration below 10 mg / L of NH3-N. In addition, carbon concentration was removed by 77%, producing final effluent with 24 mg/L COD. However, denitrification in anoxic filter was not effective even with the addition of an external carbon source. There was a reduction of up to 56% of nitrogen caused by the process of simultaneous nitrification and denitrification (SND). The high voids space presented by this type of support material coupled with direct aeration of the sludge, allows the respiration of biomass retained between the endogenous phase, increased cell retention time and sludge retention capacity, producing a final effluent with turbidity less than 5 UT and total suspended solids around 5.0 mg/L

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stabilization pond is the main technology used for treatment wastewater, in northeast Brazil, due to lower cost of deployment, operation and maintenance compared to other technologies. Most systems of stabilization ponds has been in operation for some time, on average 10 years of operation, receiving high organic loads and do not have good removal efficiencies of the main parameters for which have been designed. Therefore it is necessary to work to quantify the efficiency of current systems. This study evaluated the biodegradability of organic matter in raw sewage, the removal of organic matter in reactors and determination of the kinetic constant removal of organic matter (k), both in reactors and in raw sewage, based on the analysis made in the laboratory and through mathematical methods proposed in the literature, in nine systems stabilization ponds, located in Rio Grande do Norte. In relation the degradation kinetics in stabilization ponds, it was observed that many papers published in the literature were obtained in pilot-scale systems, which often, due to the action of external factors such as wind and temperature, these can t be considered as a reference in the analysis of the kinetic constant K, so the need for more research into systems of scale. This study had three distinct phases and simultaneous, routine monitoring, study of the daily cycle and the determination of kinetic constant of degradation of organic matter (K). The monitoring showed that the removal efficiencies of organic matter on most systems were lower than suggested by the literature, the best efficiencies of around 76% (BOD) and 72% (COD) and the worst of the order of 48% (BOD) and 55% (COD). The calculation of K in raw sewage (Ke) was within the range of variation expected in the literature (0.35 to 0.60 days-1). Already for the results obtained for K in the reactors (Kr), there were well below the values recommended in the literature (0.25 to 0.40 d-1 for complete mix and from 0.13 to 0.17 d-1 for flow dispersed), in line with the overloads that organic systems are subject

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigated the influence of the molar ratio, the phosphorus initial concentration, the mixture gradient, mixing time, pH and the secondary nucleation on struvite s crystallization in synthetic water in batch reactors. The study was divided into two stages. The first investigated struvite s crystallization at different Mg:N:P molar ratios and at different initial concentrations of magnesium, nitrogen and phosphorus. It was also evaluated the importance of secondary nucleation on the struvite s crystallization. In the second, five parameters were tested to evaluate their influence on the struvite s crystallization, which were: Mg:N:P molar ratio, initial concentration of phosphate, mixing time, mixture gradient and pH. The best conditions for struvite s crystallization were: Mg:N:P = 1,3:1:1 molar ratio; mixture gradient = 60 rpm, pH = 10.0, mixing time = 5 minutes and high initial concentrations of the constituent ions of struvite. Furthermore, the use of struvite crystals as seed influenced positively on the struvite s crystallization

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The struvite precipitation in wastewater treatments plants offer advantages to obtaining a economically viable product, containing phosphorus, nitrogen and magnesium, in a bioavailable conditions to plants. The precipitation process requires ideal conditions, but all of these aspects are difficult to obtain and may result in resistance to collect crystals during the sedimentation process. Therefore, instead find the best conditions for precipitation, we propose the dissolved air flotation as another method to retrieve the crystals. The application of dissolved air flotation method to promote separation of struvite crystals from sewage supernatant, was evaluated in a precipitation-flotation reactor (flotatest) and were compared with the precipitation-sedimentation assays (jar test). Finally, were observed that the dissolved air flotation process was as feasible as sedimentation to promote struvite crystals separation, and the pH are the most influencer factor for an efficient separation

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Experience in the use of stabilization ponds shows that this is a system with low cost, easy operation and maintenance and suitable for tropical countries. One of its disadvantages is due to high concentrations of suspended solids, mainly due to algal biomass in the effluents. Accordingly, the dissolved air flotation has been shown to be an efficient post-treatment technology. However, the efficiency of this process is related to coagulation and flocculation steps, as well as the adjustment of the involved variables in the process. The objective of this work was to evaluate the algae removal efficiency from wastewater stabilization ponds and the influence of the factors involved in the process using dissolved air flotation. For this, we used primary facultative and maturation effluents of ETE Ponta Negra in Natal. We did tests of coagulation, flocculation and flotation with the samples, using the equipment flotatest. In this process were tested coagulants aluminum sulfate and ferric chloride, and varied the factors pH, coagulant concentration, polymer concentration and rate of recirculation. At the end of the experiments were analyzed turbidity, suspended solids, color, COD and chlorophyll "a". These results were submitted to descriptive statistics to verify the efficiency of the process in general, and regression analysis to identify models that describe the process and demonstrate the factors that have greater influence on flotation. After step methodology, high values were found removal efficiency of suspended solids, reaching values greater than 90% in the best cases. It was concluded that flotation is more efficient in the facultative pond effluent using ferric chloride, and the variability of algae may negatively influence the process. Regression analyzes showed that pH is the most influential variable in the coagulation-flocculation-flotation, and its optimal value among the tested is 5.5 for both coagulants

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This research evaluated the microalgae removal produced in a stabilization pond system using biofilters as post-treatment, besides characterizing the effluents of stabilization ponds and filters in relation to concentrations of algal biomass (chlorophyll a and suspended solids), organic matter (BOD and COD), total phosphorus, orthophosphate, pH and dissolved oxygen, and tried to correlate physicochemical parameters with chlorophyll "a". It was held at the Ponta Negra ETE which is constituted by three stabilization ponds, with a primary facultative pond and two of maturation. For the algae removal were used two submerged bio-filters: the filter FPF (Facultative Pond Filter), fed with facultative pond effluent; and the filter MPF (Maturation Pond Filter), fed with second maturation pond effluent. The filling material of both filters was predominantly gravel no. 2, although it contains portions of gravel no. 1 and no. 3. The filters operating conditions were bad, they were nearly 10 years without maintenance, without cleaning or removal of sludge since the time of its construction, and part of the filling material may be obstruct. Despite poor operating conditions were obtained satisfactory results, in level of posttreatment. Removal efficiencies in relation to BOD and COD were 7 and 25% in FPF and 9 and 19% and in MPF, respectively. In relation to TSS efficiencies in MPF and FPF were 37 and 20%, respectively. As for the chlorophyll "a" removal, the FPF efficiency was 44% and the MPF was 40%. There was 50% of consumption of dissolved oxygen, on average, within the filters. Two profiles were performed in the filters, and it was possible to conclude that variations throughout the day were not statistically significant, and that, regardless of the time of collection, they would have the same representation comparing to the time of data collection (7 am) and the daily average, although individual variations throughout the day have been shown to be significant. Another important observation is that the correlations between Chlorophyll a and TSS were bigger and more significant in the effluent of the filters than in the effluent of the ponds

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of membrane filters in the post-treatment of sewage has been increasingly employed to obtain water quality, applicable to various forms of reuse. Despite the advantages presented using the permeate membranes, such as saving water and reducing water pollution, the concentrate generated in the process ends up being an inconvenience to the deployment of this technology due to lack of sustainable solutions for their management. Thus, the main objective of this research was to evaluate the use of membranes for microfiltration, ultrafiltration, nanofiltration and reverse osmosis concentrated in agriculture, using it as liquid fertilizer. The permeated membranes were also assessed in order to identify activities in which they could be reused. Five configurations were established from four types of membranes, so that each configuration represents a different system. The tests were conducted in batch mode, with triplicate for each configuration. The results indicated that permeated the microfiltration and ultrafiltration can be used in urban areas, in non-potable uses. Have the nanofiltration permeate can be reused in the industry, replacement cooling towers, and other non -potable uses required in the manufacturing unit. The permeate obtained in reverse osmosis met the intended uses for nanofiltration as well as the standards required for boiler feed, adding alkalizing being required to raise the pH to the recommended value. Concentrates generated in nanofiltration and reverse osmosis can be availed as liquid fertilizer in agriculture, but they must be diluted in the irrigation water, in order to adjust the salt concentration allowed for the least tolerant crops patterns

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work intends to develop an approach based through scientific criteria in the operational diagnosis of ponds of stabilization, starting from analyses accomplished in loco and in laboratory of 78 systems of sewer treatment through ponds of stabilization in the State of Rio Grande do Norte. The objectives of the research are: to map, to evaluate and to diagnose the operational acting of the ponds of stabilization of the state of Rio Grande do Norte, through visits in loco and analyses laboratory; to build a SIG, through the map rain, locate the points of releases of sewages of the systems of existent ponds in Rio Grande do Norte, as well as operational data and his/her respective efficiency diagnosis in the removal of BOD and Coliforms Termotolerantes; to evaluate, in real scale, three systems of ponds of stabilization of RN in the operational efficiency for the parameters BOD5, COD, pH, Temperature, OD and Coliforms Termotolerantes. Of 78 ETEs of appraised RN just, 9% or 7 had maximum concepts in what concerns the removal of BOD and Coliforms Termotolerantes and 41% or 32, they had the worst concepts in term of operational efficiency. The flowing concentrations ETEs of RN of BOD and Coliforms were of 410mg/L and 2,50x107UFC/100ml, the predominant configuration is of the type F1+M1+M2, the relationship BOD/COD revealed for the sewer tributary characteristic biodegradable high. For the study of case of 3 ETEs, the best operational efficiencies in decreasing order were: Cidade (Municipal district), it Roça (State) and São Miguel (SAAE). The removals of final BOD were 51,6mg/L; 108,27mg/L and 62,6mg/L, tends efficiency of 82%; 74% and 81%. In term of coliforms removal in the final effluentes were 1,90x103UFC/100ml; 1,50x104UFC/100ml and 3,10x104UFC/100ml, tends efficiencies of 99,99%; 99,95% and 99,90%. In what it concerns the practice of agricultural reúso of cultures consumed raw, none of 3 ETEs assisted the parameters of the Resolution CONAMA 357/05, for other reúso practices, all assisted the categories B and C of OMS. For release in body receiving ETE Cidade just, they assist the demands of the resolution of CONAMA 357/05, by study of purification solemnity of the receiving body. The maintenance lack and operation; exclusive operator in ETEs and operation knowledge was the contributory factors for the operational fall in appraised ETEs of RN

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of the present work is to verify the effects of Rural Social welfare in the family agriculture of the microrregião Serra de São Miguel-RN. The study based on available bibliography on the theme, in secondary data and in a rising amostral accomplished in three municipal districts (Encanto, São Miguel and Riacho de Santana) of the microrregião. The universe of the study was the establishments of the family agriculture appeared in the Agricultural Census of 2006, in those municipal districts. The unit of considered analysis was the rural family, with the interviews being applied close to the farmers' families with and without retired rural. The sample was of 94 present families in the family establishments. The results demonstrate that the Rural Precaution reaches a significant covering degree in the rural area of the researched municipal districts, with an average of 1,57 beneficiaries for home in the families with retired. The data of the research attest that the family agriculture in the microrregião Serra de São Miguel-RN it has few favorable conditions for his/her development, once, besides the shortage of lands and of the climatic factor of the area, the returned public politics the family farmers' totality - like PRONAF and PAA -, it has been unable to give effective answers for the improvement of the life conditions in the rural way, have seen the minimum amount of families reached by those politics, be in function of the drawing or of the atmosphere where they are done. In this context, he/she stands out the importance of the Rural Precaution that, in function of the application of the constitutional devices that you/they guaranteed his/her universalization, it has been the only relevant public politics that, in fact, it has been reaching her/it all their beneficiary potentials. Given the general situation of the family agriculture of the microrregião and of the specific characteristics of the researched family establishments, the hypothesis was corroborated that the rural retirement doesn't contribute directly to the increase / making possible of the family agriculture. In spite of 57,4% of the families with retired have declared to use resources of the retirement in the costing of the rural activity carried out by the family, the annual medium value of the expense just located around 7,02% of the annual value of the retirements gained by the families in the year of 2010. Data the low levels in that the social reproduction of the great majority of the family establishments of the microrregião, the maintenance of the families is operated represents the main destiny of the resources precautions. It was also confirmed the hypothesis that the Rural Precaution constitutes the main monetary contribution of the families with retired. For more than 93% of the families with retired, the retirements doing 50% or more of the total of the family monetary income, and in the composition of the rural income of the families with retired and pensioners, the originating from income the rural retirements are equal to 65,24% of the total of the annual income obtained by the families. It is ended, because, that the rural precaution, given to the adversities for the development of the family agriculture, of the operational inefficacy of the public politics and of the few opportunities of generation of existent income in the local savings, it is the main responsible for the reduction of the poverty and, consequently, for the improvements of the conditions of life of the families of and with seniors in the rural way of the microrregião Serra de São Miguel-RN

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lucrèce, penseur latin du siècle I, avant J.C., écrire que le peur de la mort imputé par la religion et la superstition, nourrit le souhait à la richesse, l'ambition du pouvoir et les actes insensés, dont les conséquences se reflètent dans les maladies de l'âme. La terreur qui s'installe chez l'homme, à l'être confronté au décès, est aussi un obstacle à la liberté et à la vie équilibrée. Les craintes sans fondement seulement seraient surmonter, avec la compréhension de la nature et du mouvement de l'âme, en percevant leur génération, corporéité et finitude. Pour cela, la compréhension des atomes et du vide, les éléments primordiaux de la nature se basent tout la connaissance de l'âme. L'objectif de ce travail est enquêter la nature de l'âme dans Lucrèce, en présentant une réflexion sur les craintes sans fondement et la peur de la mort, comme une manière de percevoir le mouvement de la vie elle-même, et de que manière sa philosophie affronte à la crainte de la mort.