37 resultados para Úlceras de pressão


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The strength of respiratory muscle are frequently assessed by maximal inspiratory and expiratory pressure, however, the maneuvers to assess PImax and PEmax are difficult for many patients. The sniff nasal inspiratory pressure (SNIP) is a simple and noninvasive technique use to assess inspiratory muscles strength. Reference values have been previous established for SNIP in adults but no previous studies have provided reference values for SNIP in adult Brazilian population. The main objective of this study were propose reference values of SNIP for Brazilian population through establishment of relationship between anthropometric measurements, physical activity profile and SNIP and at the same time compare the values obtained with reference values previously published. We studied 117 subjects (59 male and 58 female) distributed in different age grouped 20-80 years old. The results showed on significant positive relationship between SNIP and height and negative correlation with age (p<0.05). In the multiple linear regression analysis only age continued to have an independent predictive role for the two dependent variables that correlated with SNIP. The values of SNIP found in Brazilian population were higher when compared with predict values of previous studies. The results of this study provide reference equations of SNIP for health Brazilian population from 20 to 80 years old

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The clinical importance of evaluating the respiratory muscles with a variety of tests has been proposed by several studies, once that the combination of several tests would allow a better diagnosis and therefore, a better clinical follow of disorders of the respiratory muscles. This study aimed to evaluate the feasibility of adapting a national electronic manovacuometer to measure the nasal inspiratory pressure (study 1) and analyze the level of load intensity of maximum voluntary ventilation, as well as the variables that may influence this maneuver in healthy subjects (study 2). We studied 20 healthy subjects by a random evaluation of two measures of SNIP in different equipments: a national and an imported. In study 2 it was analyzed the intensity of the load of MVV test, change in pressure developed during the maneuver, the possible differences between genders, and the correlations between the flow developed in the test and the result of MVV. In study 1 it was found the average for both measures of nasal inspiratory pressures: 125 ± 42.4 cmH2O for the imported equipment and 131.7 ± 28.7 cmH2O for the national one. Pearson analysis showed a significant correlation between the average, with a coefficient r = 0.63. The average values showed no significant differences evaluated by paired t test (p> 0.05). In the Bland-Altman analysis it was found a BIAS = 7 cmH2O, SD 32.9 and a confidence interval of - 57.5 cmH2O up to 71.5 cmH2O. In the second study it was found significant differences between the genders in the air volume moved, being higher in males 150.9 ± 13.1 l / min vs 118.5 ± 15.7 L / min for (p = 0.0002, 95% CI 44.85 to 20:05). Regarding the inspiratory and expiratory loading, they were significantly higher in men than in women, peak inspiratory pressure (34.7 ± 5.3 cmH2O vs 19.5 ± 4.2 cmH2O, 95% CI - 18.0 to -12.3, p <0.0001), peak expiratory (33.8 vs. 23.1 ± 5.9 cmH2O ± 5.4 cmH2O, 95% CI -17.1 to - 4.6, p <0.0001), and the delta pressure (59.7 ± 10 cmH2O vs 36.8 ± 8.3 cmH2O, 95% CI 14.5 to 31.2, p <0.0002). The Pearson correlation showed that the flow generated by the maneuver is strongly correlated with the delta-expiratory pressure / inspiratory (r2= 0.83,R = 0.91, 95%IC 0.72 a 0.97 e p< 0.0001).Through these results we suggest that the national electronic manovacuometer is feasible and safe to perform the sniff test in healthy subjects. For the MVV, there are differences between the genders in the intensity of pressure developed during the maneuver. We found a load intensity considered low during the MVV, and found a strong correlation between the flow generated in the test and the delta pressure expiratory / inspiratory

Relevância:

20.00% 20.00%

Publicador:

Resumo:

observar os efeitos agudos de diferentes intensidades de Pressão Expiratória Positiva (PEP) sobre a cinemática do complexo toracoabdominal de pacientes acometidos por Acidente Vascular Encefálico (AVE). Métodos: Foram selecionados 21 indivíduos com AVE e 16 indivíduos saudáveis pareados por idade sexo e IMC para grupo controle. Avaliamos função pulmonar, pressões dos músculos respiratórios e os volumes pulmonares por meio da Pletismografia Optoeletrônica durante três diferentes intensidades de PEP 10, 15 e 20 cmH2O. Resultados: o efeito da PEP no volume corrente (VC) do grupo AVE em relação ao grupo controle foi diferente. Enquanto o grupo controle aumentou o VC em relação a respiração tranquila em 343%, 395,2% e 431,8% nas PEP10, PEP15 e PEP20 cmH2O o grupo AVE aumento 186%, 218.8% e 209.5% (p < 0.0001). A PEP também influenciou de forma diferente em relação ao Tempo inspiratório com intensidades diferentes no grupo controle e AVE (p < 0.0001). No ciclo de trabalho foi observado um aumento no grupo controle nas PEP10 (p < 0.001) e PEP15 (p < 0.05) e no grupo AVE foi observada uma redução PEP20 (p < 0.01) quando comparada com a respiração tranquila. Os volumes operacionais do grupo AVE foi observado aumento do volume inspiratório final da parede torácica (Vifpt) e do Volume expiratório final da parede torácica (Vefpt) diferente do grupo controle que gerou aumento do Vifpt acompanhado de diminuição do Vefpt durante as três intensidades de PEP. Conclusão: A hiperinsuflação observada no grupo AVE demonstra que essa terapêutica deve ser utilizada com cautela especialmente nas intensidades maiores que 10 cmH2O para essa população

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Venous wounds cause physical, psychological and financial problems that impact the quality of life of patients. Treatment alternatives are investigated in order to reduce healthcare costs and improve quality of life of people affected by this problem. Physical resources, such as therapeutic ultrasound (US), are being considered in the treatment of ulcers as a potential healing agent. This study aimed to investigate the application of US as a treatment for venous ulcers. Subjects were divided into two groups: US group, where treatment consisted of 5 sessions of pulsed US (3 MHz, 1W/cm²) associated with compression and kinesiotherapy; and sham group, where individuals went through the same procedures, but with sham US therapy. Subjects were evaluated for wound size by planimetry and digital photography, visual analogue scale for pain, quality of life by the questionnaires SF- 36 and VEINES-QoL/Sym and enzymatic activity of metalloproteinases 2 and 9 by zymography. It was observed mean reduction in wound area of 41.58±53.8% for the US group and 63.47±37.2% for the placebo group, maintenance of quality of life scores in the US group and significant improvement (p<0.05) in the placebo group by VEINES questionnaire. It was observed decreased perception of pain in the placebo group. Sample feasibility for analysis of the protein activity of metalloproteinases 2 and 9 by zymography collected by swab method was also confirmed. Our data did not give us evidence to support the theory that the US accelerates healing of venous ulcers in a short-term analysis. However, we observed that standard care associated with compression therapy and kinesiotherapy were able to significantly shorten the progression of chronic venous ulcers

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chronic venous disease (CVD) is evident among the chronic diseases and affects the elderly population and primarily is responsible for leg ulcers in this population. The use of dressings in the care of a venous ulcer is a fundamental part of the treatment for healing, however, evidence to assist in choosing the best dressing is scarce. The main objective of this study was to evaluate the effectiveness of treatment with hydrogel in the healing of venous ulcers using search methods, synthesis of information and statistical research through a systematic review and meta-analysis. Randomized controlled trials were selected in the following databases: CENTRAL; DARE; NHS EED; MEDLINE; EMBASE; CINAHL. Beyond these databases three websites were consulted to identify ongoing studies: ClinicalTrials.gov, OMS ICTRP e ISRCTN. The primary outcomes were analyzed: complete wound healing, incidence of wound infection and the secondary were: changes in ulcer size, time to ulcer healing, recurrence of ulcer, quality of life of participants, pain and costs of treatment. Four studies are currently included in the review with a total of 250 participants. The use of hydrogel appears to be superior to conventional dressing, gauze soaked in saline, for the healing of venous leg ulcers; 16/30 patients showed complete healing of ulcers (RR 5,33, 95%CI [1,73,16,42]). The alginate gel was shown to be more effective when compared to the hydrogel dressing in reduction of the wound area; 61,2% (± 26,2%) with alginate e 19,4% (± 24,3%) with hydrogel at the end of four weeks of treatment. Manuka honey has shown to be similar to the hydrogel dressings in percentage of area reduction. This review demonstrated that there is no evidence available about the effectiveness of the hydrogel compared to other types of dressings on the healing of venous leg ulcers of the lower limbs, thus demonstrating the need of future studies to assist health professionals in choosing the correct dressing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In February 2011, the National Agency of Petroleum, Natural Gas and Biofuels (ANP) has published a new Technical Rules for Handling Land Pipeline Petroleum and Natural Gas Derivatives (RTDT). Among other things, the RTDT made compulsory the use of monitoring systems and leak detection in all onshore pipelines in the country. This document provides a study on the method for detection of transient pressure. The study was conducted on a industrial duct 16" diameter and 9.8 km long. The pipeline is fully pressurized and carries a multiphase mixture of crude oil, water and natural gas. For the study, was built an infrastructure for data acquisition and validation of detection algorithms. The system was designed with SCADA architecture. Piezoresistive sensors were installed at the ends of the duct and Digital Signal Processors (DSPs) were used for sampling, storage and processing of data. The study was based on simulations of leaks through valves and search for patterns that characterize the occurrence of such phenomena

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior