23 resultados para stream function-vorticity-current density


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper proposed the study of the treatment of a synthetic wastewater contaminated with BTX by electro-oxidation batch with the anode of Ti/PbO2, and the adsorption of BTX using expanded perlite as adsorbent material, and to evaluate the best operating conditions both methods in order to perform a sequential treatment (adsorption and electro-oxidation) and achieve greater efficiency in the removal of the compounds. The operating conditions were measured: temperature, current density and applied amount of the adsorbent material, by UV-VIS analysis and Demand Chemical oxygen demand (COD). According to the experimental results, the electro-oxidative treatment was efficient in the degradation of the compounds BTX (benzene, toluene and xylenes) in synthetic sewage due to the electrochemical properties of the anode of Ti/PbO2. The applied current density and temperature promoted increased efficiency of COD removal, reaching obtain percentages greater than 70%. In the adsorption process, the temperature increase was not a factor in the removal of organic matter, while the increase in the amount of adsorbent material led to an increase in the percentage removal, obtaining 66.30% using 2 g of adsorbent. The selected operating conditions of both treatments performed separately take into account the removal efficiency of organic matter, and the low energy consumption and operating costs, so the sequential treatment were satisfactory reaching 87.26% of COD removal using adsorption as a pretreatment. Quantification of BTX through the analysis of gas chromatography at the end of the treatments also confirmed the removal efficiency of organic compounds, giving outstanding advantages to sequential treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The produce of waste and the amount of the water produced coming from activities of petroleum production and extraction has been a biggest challenge for oil companies with respect to environmental compliance due to toxicity. The discard or the reuse this effluent containing organic compounds as BTEX (benzene, toluene, ethylbenzene and xylene) can cause serious environmental and human health problems. Thus, the objective this paper was study the performance of two process (separately and sequential) in one synthetic effluent for the benzene, toluene and xylene removal (volatile hydrocarbons presents in the produced water) through of electrochemical treatment using Ti/Pt electrode and exchange resin ionic used in the adsorption process. The synthetic solution of BTX was prepared with concentration of 22,8 mg L-1, 9,7 mg L-1 e 9,0 mg L-1, respectively, in Na2SO4 0,1 mol L-1. The experiments was developed in batch with 0.3 L of solution at 25ºC. The electrochemical oxidation process was accomplished with a Ti/Pt electrode with different current density (J = 10, 20 e 30 mA.cm-2). In the adsorption process, we used an ionic exchange resin (Purolite MB 478), using different amounts of mass (2,5, 5 and 10 g). To verify the process of technics in the sequential treatment, was fixed the current density at 10 mA cm-2 and the resin weight was 2.5 g. Analysis of UV-VIS spectrophotometry, chemical oxygen demand (COD) and gas chromatography with selective photoionization detector (PID) and flame ionization (FID), confirmed the high efficiency in the removal of organic compounds after treatment. It was found that the electrochemical process (separate and sequential) is more efficient than absorption, reaching values of COD removal exceeding 70%, confirmed by the study of the cyclic voltammetry and polarization curves. While the adsorption (separately), the COD removal did not exceed 25,8%, due to interactions resin. However, the sequential process (electrochemical oxidation and adsorption) proved to be a suitable alternative, efficient and cost-effectiveness for the treatment of effluents petrochemical.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Textile industry has been a cause of environmental pollution, mainly due to the generation of large volumes of waste containing high organic loading and intense color. In this context, this study evaluated the electrochemical degradation of synthetic effluents from textile industry containing Methylene Blue (AM) dye, using Ti/IrO2-Ta2O5 and Ti/Pt anodes, by direct and indirect (active chlorine) electrooxidation. We evaluated the influence of applied current density (20, 40 and 60 mA/cm2 ), and the presence of different concentrations of electrolyte (NaCl and Na2SO4), as well as the neutral and alkaline pH media. The electrochemical treatment was conducted in a continuous flow reactor, in which the electrolysis time of the AM 100 ppm was 6 hours. The performance of electrochemical process was evaluated by UV-vis spectrophotometry, chemical oxygen demand (COD) and total organic carbon (TOC). The results showed that with increasing current density, it was possible to obtain 100 % of color removal at Ti/IrO2-Ta2O5 and Ti/Pt electrodes. Regarding the color removal efficiency, increasing the concentration of electrolyte promotes a higher percentage of removal using 0,02 M Na2SO4 and 0,017 M NaCl. Concerning to the aqueous medium, the best color removal results were obtained in alkaline medium using Ti/Pt. In terms of organic matter, 86 % was achieved in neutral pH medium for Ti/Pt; while a 30 % in an alkaline medium. To understand the electrochemical behavior due to the oxygen evolution reaction, polarization curves were registered, determining that the presence of NaCl in the solution favored the production of active chlorine species. The best results in energy consumption and cost were obtained by applying lower current density (20 mA/cm2 ) in 6 hours of electrolysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work was performing effluent degradation studies by electrochemical treatment. The electrochemical oxidation (EO) hydroquinone (H2Q) was carried out in acid medium, using PbO2 electrode by galvanostatic electrolysis, applying current densities of 10 and 30 mA/cm2 . The concentration of H2Q was monitored by differential pulse voltammetry (DPV). The experimental results showed that the galvanostatic electrolysis process performance significantly depends on the applied current density, achieving removal efficiencies of 100% and 80 % and 10 applying 30 mA/cm2 , respectively. Furthermore, the electroanalytical technique was effective in H2Q be used as a detection method. In order to test the efficiency of PbO2 electrode, the electrochemical treatment was conducted in an actual effluent, leachate from a landfill. The liquid waste leachate (600ml effluent) was treated in a batch electrochemical cell, with or without addition of NaCl by applying 7 mA/cm2 . The efficiency of EO was assessed against the removal of thermo-tolerant coliforms, total organic carbon (TOC), total phosphorus and metals (copper, cobalt, chromium, iron and nickel). These results showed that efficient removal of coliforms was obtained (100%), and was further decrease the concentration of heavy metals by the cathode processes. However, results were not satisfactory TOC, achieving low total removal of dissolved organic load. Because it is considered an effluent complex were developed other tests with this effluent to monitor a larger number of decontamination parameters (Turbidity, Total Solids, Color, Conductivity, Total Organic Carbon (TOC) and metals (barium, chromium, lithium, manganese and Zinc), comparing the efficiency of this type of electrochemical treatment (EO or electrocoagulation) using a flow cell. In this assay was compared to electro streaming. In the case of the OE, Ti/IrO2-TaO5 was used as the anode, however, the electrocoagulation process, aluminum electrodes were used; applying current densities of 10, 20 and 30 mA/cm2 in the presence and absence of NaCl as an electrolyte. The results showed that EO using Ti/IrO2–TaO5 was anode as efficient when Cl- was present in the effluent. In contrast, the electrocoagulation flow reduces the dissolved organic matter in the effluent, under certain experimental conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The textile effluents are a complex mixture of many pollutants that contain high organic loads, severe color and toxic compounds. The high concentration of the textile effluent may cause increased chemical demand (COD) and biochemical (BOD) of oxygen, elevated temperature, acidity or alkalinity, causing damage and environmental problems. In addition to representing a serious threat to human health such effluent is also quite toxic to most aquatic organisms. And for this reason, one must meet the concentration limits for emission sources and sewage system. This study aimed to investigate the performance of electrochemical treatment of a textile effluent for the removal of color, turbidity, dissolved oxygen (DO) and dissolved organic matter by investigating the influence of experimental parameters such as the electrocatalyst materials (Ti/Pt and Ti/Pt-SnSb) and current density in order to compare their efficiency, energy consumption and cost. The dye Novacron Blue CD (NB) was employed in synthetic solution, while the dyes Remazol Yellow 3RS (RY 3RS) Remazol Red RR Gran (RR-RR Gran) and Navy Blue CL-R (NB CL-R) were used to generate simulated textile effluent laboratory. The results showed that the application of electrochemical oxidation process favors the elimination of color effectively independent the electrocatalytic material and current used, as well as treated effluent. However, the influence of electrocatalytic material was crucial to reduction of the organic matter in all cases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hexavalent chromium is a heavy metal present in various industrial effluents, and depending on its concentration may cause irreparable damage to the environment and to humans. Facing this surrounding context, this study aimed on the application of electrochemical methods to determine and remove the hexavalent chromium (Cr6+) in simulated wastewater. To determine was applied to cathodic stripping voltammetry (CSV) using ultra trace graphite electrodes ultra trace (work), Ag/AgCl (reference) and platinum (counter electrode), the samples were complexed with 1,5- diphenylcarbazide and then subjected to analysis. The removal of Cr6+ was applied electrocoagulation process (EC) using Fe and Al electrodes. The variables that constituted the factorial design 24, applied to optimizing the EC process, were: current density (5 and 10 mA.cm-2), temperature (25 and 60 ºC), concentration (50 and 100 ppm) and agitation rate (400 and 600 RPM). Through the preliminary test it was possible the adequacy of applying the CSV for determining of Cr6+, removed during the EC process. The Fe and Al electrodes as anodes sacrifice showed satisfactory results in the EC process, however Fe favored complete removal in 30 min, whereas with Al occurred at 240 min. In the application of factorial design 24 and analysis of Response Surface Methodology was possible to optimize the EC process for removal of Cr6+ in H2SO4 solution (0.5 mol.L-1), in which the temperature, with positive effect, was the variable that presented higher statistical significance compared with other variables and interactions, while in optimizing the EC process for removal of Cr6+ in NaCl solution (0.1 mol.L-1) the current density, with positive effect, and concentration, with a negative effect were the variables that had greater statistical significance with greater statistical significance compared with other variables and interactions. The utilization of electrolytes supports NaCl and Na2SO4 showed no significant differences, however NaCl resulted in rapid improvement in Cr6+ removal kinetics and increasing the NaCl concentration provided an increase in conductivity of the solution, resulting in lower energy consumption. The wear of the electrodes evaluated in all the process of EC showed that the Al in H2SO4 solution (0.5 mol.L-1), undergoes during the process of anodization CE, then the experimental mass loss is less than the theoretical mass loss, however, the Fe in the same medium showed a loss of mass greater experimental estimated theoretically. This fact is due to a spontaneous reaction of Fe with H2SO4, and when the reaction medium was the NaCl and Na2SO4 loss experimental mass approached the theoretical mass loss. Furthermore, it was observed the energy consumption of all processes involved in this study had a low operating cost, thus enabling the application of the EC process for treating industrial effluents. The results were satisfactory, it was achieved complete removal of Cr6+ in all processes used in this study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to evaluate the potential of oxidative electrochemical treatment coupled with adsorption process using expanded perlite as adsorbent in the removal of textile dyes, Red Remazol and Novacron Blue on synthetic effluent. Dyes and perlite were characterized by thermogravimetry techniques (TG), Differential Scanning Calorimetry (DSC), Spectroscopy infrared (IR), Scanning Electron Microscopy (SEM), X-ray diffraction (XRD) and X-ray fluorescence (XRF) techniques. Electrochemical treatments used as anodes, Ti/Pt and Pb/PbO2 under different conditions: 60 minutes, current density 20, 40 e 60 mAcm-2, pH 1, 4.5 e 8 and temperature variation 20, 40 e 60 ºC. In the case of adsorption tests, contact time of 30 minutes for the Remazol Red dye and 20 minutes for Novacron Blue were established, while pH 1, 4.5 e 8, 500 mg adsorbent and temperature variation 20, 40 e 60 ºC were used for both treatments. The results indicated that both treatments, electroxidation/adsorption and the adsorption/electroxidation, were effective for removing color from synthetic solutions. The consumption of electricity allowed to evaluate the applicability of the electrochemical process, providing very acceptable values, which allowed us to estimate the cost. Total organic carbon (TOC) and Gas Chromatography linked mass spectrometer (GC-MS) analyzes were performed, showing that the better combination for removing organic matter is by Pb/PbO2 and perlite. Meanwhile, GC-MS indicated that the by-products formed are benzoic acid, phthalic acid, thiocarbamic acid, benzene, chlorobenzene, phenol-2-ethyl and naphthalene when Remazol Red was degraded. Conversely, aniline, phthalic acid, 1, 6 - dimethylnaphthalene, naphthalene and ion hidroxobenzenosulfonat was detected when Novacron Blue was studied. Analyses obtained through atomic absorption spectrometry showed that there was release of lead in the electrochemical oxidation of analyzes that were performed with the anode Pb/PbO2, but these values are reduced by subjecting the effluent to adsorption analysis. According to these results, sequential techniques electroxidation/adsorption and adsorption/electroxidation are to treat solutions containing dyes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to evaluate the potential of oxidative electrochemical treatment coupled with adsorption process using expanded perlite as adsorbent in the removal of textile dyes, Red Remazol and Novacron Blue on synthetic effluent. Dyes and perlite were characterized by thermogravimetry techniques (TG), Differential Scanning Calorimetry (DSC), Spectroscopy infrared (IR), Scanning Electron Microscopy (SEM), X-ray diffraction (XRD) and X-ray fluorescence (XRF) techniques. Electrochemical treatments used as anodes, Ti/Pt and Pb/PbO2 under different conditions: 60 minutes, current density 20, 40 e 60 mAcm-2, pH 1, 4.5 e 8 and temperature variation 20, 40 e 60 ºC. In the case of adsorption tests, contact time of 30 minutes for the Remazol Red dye and 20 minutes for Novacron Blue were established, while pH 1, 4.5 e 8, 500 mg adsorbent and temperature variation 20, 40 e 60 ºC were used for both treatments. The results indicated that both treatments, electroxidation/adsorption and the adsorption/electroxidation, were effective for removing color from synthetic solutions. The consumption of electricity allowed to evaluate the applicability of the electrochemical process, providing very acceptable values, which allowed us to estimate the cost. Total organic carbon (TOC) and Gas Chromatography linked mass spectrometer (GC-MS) analyzes were performed, showing that the better combination for removing organic matter is by Pb/PbO2 and perlite. Meanwhile, GC-MS indicated that the by-products formed are benzoic acid, phthalic acid, thiocarbamic acid, benzene, chlorobenzene, phenol-2-ethyl and naphthalene when Remazol Red was degraded. Conversely, aniline, phthalic acid, 1, 6 - dimethylnaphthalene, naphthalene and ion hidroxobenzenosulfonat was detected when Novacron Blue was studied. Analyses obtained through atomic absorption spectrometry showed that there was release of lead in the electrochemical oxidation of analyzes that were performed with the anode Pb/PbO2, but these values are reduced by subjecting the effluent to adsorption analysis. According to these results, sequential techniques electroxidation/adsorption and adsorption/electroxidation are to treat solutions containing dyes.