42 resultados para sewage


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The disposal of sewage sludge is a growing problem face up to management of sanitary sevices. Otherwise, because its making process characteristic, the Ceramic Industry can tolerate the presence of this wastes as raw material. This study has as object to confirm the use of the sewage sluge in the Ceramic Industry like a sustentable alternative for its disposal. Futhermore, this study quests to evaluate the maximum proportion for incorporation of sludge wich result in technically and enviromentally suitable bricks. For found this proportion, the research consisted of (1) making of bricks in full scale, adde up 0%, 5%,10%, 15%, 20%, 25%,30%, 35% e 40% sludge, with size 220x105x45 mm, hand-molded by rammer and baked by industrial kiln; and (2) tecnical and enviromental evaluation of this bricks, according to Brazilian norms. The raw material uses were two distinct clays come from Goianinha/RN and sewage comes from a septic system tank and pumped into tank vehicle, of Natal/RN. The technical evaluation allowed to conclude the addiotion of the sludge brings about signifcant lost of mass and the water absorption grew up according to increase of sludge: every sludge-amended clay bricks absorved more water than control group. Thus, the compressive strength was signicantly decreased because the increase of sludge: bricks with 5% sludge added lost 45% of strength achieved at control group; the bricks made with 10 and 20% lost almost 70% of bigger strength. With up to 25% sludge added to the bricks, the streght decreased over 90%. Concerning heavy metal leaching, the two maximum proportion wich have tecnical approval, it means bricks sludge added with 15 and 20%, can say there is no risk of enviromental contamination using those bricks. This way, in this work context, it can to conclude the maximum proportion atends the technical and enviromental criterion is 20%

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the urban areas of the cities a larger problem of destiny of effluents of the treatment stations is verified due to the junction of the sewages in great volumes. This way the hidroponic cultive becomes important, for your intensive characteristic, as alternative of reuse. This work presents as objective the improvement of the relation hidric-nutritious of the hidroponic cultive of green forage (FVH) using treaty sewage. The production of forage was with corn (Zea mays L.), using double hybrid AG1051, in the experimental field of the Federal University of Rio Grande do Norte (UFRN), in the city of Natal-RN-Brazil. The treated effluent essentially domestic had origin of anaerobic reactor, type decant-digester of two cameras in series followed by anaerobic filters drowned. The hidroponic experimental system was composed of 08 stonemasons, with limited contours for masonry of drained ceramic brick, measuring each one 2,5 meters in length for 1,0 meter of width, with inclination of 4% (m/m) in the longitudinal sense, leveled carefully, in way to not to allow preferential roads in the flow. These dimensions, the useful area of Isow was of 2 square meters. The stonemasons of cultive were waterproof (found and lateral) with plastic canvas of 200 micres of thickness, in the white color. Controlled the entrance and exit of the effluente in the stonemasons, with cycles of 12,68 minutes, it being water of 1,18 minutes. The treatments were constituted of: T1 - 24 hours/day under it waters with flow of 2 L/min; T2 - 12 hours/day under waters with flow of 4 L/min; T3 - 12 hours/day under waters with flow of 2 L/min; and T4 - 16 hours/day under waters with flow of 3 L/min. There were evaluations of the evapotranspirometric demand, of hidroponic system affluent and effluent seeking to characterize and to monitor physical-chemical parameters as: pH, temperature, Electric Conductivity and Fecal Coliforms. This last one was analyzed to the 11 days after isow (DAS) and to the 14 DAS. The others were analyzed daily. I sow it was accomplished in the dates of February 21, 2007, first experiment, and April 10, 2007, second experiment. The density of Isow was of 2 kg of seeds, germinated before 48 hours, for square meter of stonemason. The statistic delineament was it casual entirely with two repetitions, in two experiments. It was applied Tukey test of average to five percent of probability. The cultivation cycle was of 14 DAS with evapotranspirometric demand maximum, reached by T1, of 67,44 mm/day. The analyzed parameters, as mass of green matter - Kg, productivity-Kg/m2 and reason of production of seed FVH/Kg used in Isow, the best result was presented by T1, obtaining value of up to 19,01 Kg/m2 of cultive. Without significant difference, the T4 presented greats values with 16 hours under cycle of water. The Treatments 2 and 3 with 12 hours under cycle of water, they obtained inferior results to the other Treatments. As treatment system, came efficient in the reduction of the salinity. T1 obtained reduction medium maxim of 62,5%, to the 7 DAS, in the amount of salts that enter in the system in they are absorbed in the cultivation. The cultivation FVH acted reducing the microbiologic load. Significant percentile of reduction they were reached, with up to 90,23% of reduction of Units of Colonies (UFC), constituting, like this, the Hidroponic System as good alternative of treatment of effluents of Reactors of high Efficiency

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sludge of Wastewater Treatment Plants (WTPs) disposal is a problem for any municipality, for this reason the amount of sludge production is now a key issue in selecting treatment methods. It is necessary to investigate new applications for this waste type, due to the restrictions imposed by the environmental organs. The raw materials used in the Red Ceramic, are generally very heterogeneous, for this reason, such materials can tolerate the presence of different types of wastes. In Rio Grande do Norte, the roof tiles production corresponds to 60,61% from the total of ceramic units produced. Due to the importance of the ceramic industry of roof tiles for the state, allied to the environmental problem of the sludge disposal, this work had for objective to verify the possibility of the incorporation of sewage sludge in ceramic body used for production of roof tiles. In the research, sludge originating from drying beds of WTP of the Central Campus from UFRN and clays originating from a ceramic industry from Goianinha/RN were used. The raw materials were characterized by techniques of: analysis of particles distribution by diffraction to laser; real density; consistence limits; chemical analysis by X-ray fluorescence; mineralogical analysis by X-ray diffraction; organic matter; and solids content. Five batches of roof tiles were manufactured in the approximate dosages of 2%, 4%, 6%, 8% and 10%. To evaluate the properties of each final product, tests of water absorption, impermeability, bending strength, leachability and solubility were accomplished. The roof tiles manufactured with sludge presented characteristics similar to the roof tiles without sludge in relation to the environmental risk. The results showed that it is possible to use approximately up to 4% of sludge in ceramic bodies for production of roof tiles. However, it is observed that the high amount of organic matter (71%) present in the sludge is shown as factor that limits the sludge incorporation in ceramic bodies, worsening the quality of the roof tiles. It is necessary the use of mixtures of different raw materials under point of view of the granulometry and of the other chemical and mineralogical properties for the obtaining of a satisfactory mass to the production of ceramic roof tiles

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In Natal still dominates the use of individual disposal systems for domestic sewage, once only 29% of the city has a sewarage system. Wastes that are accumulated in these individual treatment systems should be exhausted periodically, service provided by collector entrepreneurs. Some of these companies causing major damage to the environment. In Natal, only two companies have their own septage (RESTI) treatment system, which were designed with parameters from domestic sewage generating strain and inefficient systems. Therefore, the characterization becomes essential as a source of parameters for their design. Thus, this work presents the physical-chemical and microbiological characterization of waste pumped from individual sewage treatment systems. Samples collections were made weekly from 5 different trucks at the reception point on the treatment plant on the point of the preliminary treatment. From each truck it was taken 5 samples during the discharge in order to make a composite sample. Afterwards, samples were carried out to laboratory and analyses for determination of temperature, pH, conductivity, BOD, COD, nitrogen (ammonia e organic), alkalinity, oils, phosphorus, solids, faecal coliforms and helminth egg. The results were treated as a single database, and ranked according to its generating source (multi and single house, lodging, health, services and / or food), area of origin (metropolitan, south and north) and type of system (cesspits, septic tank and / or sink). Through these data it was possible to verify that the type of system adopted by most in Natal and the metropolitan region is cesspit, besides to confirm the difference between the septage of areas with a population have different social and economical characteristics. It was found that the septage have higher concentrations than domestic sewage, except for thermotolerant coliforms that showed concentrations of 1,38E+07. Among the parameters studied, is the median values identified for COD (3,549 mg / L), BOD (973mg / L) and total solids (3.557mg / L). The volatile fraction constitutes about 70% of the total solids of the septage. For helminths has been a median of 7 eggs/L. In general, the characteristics of the waste followed the variability found in the literature reviewed for all variables, showing high amplitudes

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Because of disability in public policy development in mind to attend issues of sanitation in the municipalities, companies known as "clean-blue" appeared proposing to solve a simple collection and management of wastewater produced in single or multifamily residences, commercial, hospitals, etc. In the case of an activity in which there are no worries about the fate of sewage, emerged some doubts about the degree of health and environmental safety in these companies. Traditionally, most of them makes the provision of waste depleted soil or wetland, open, usually located on the outskirts of cities (MENESES, 2001). In turn, the sludge from septic tanks exhausted, provided no technical criteria - in the soil, rivers and as an agricultural fertilizer put in risk the health of the population and environmental quality. This work was entered in the search network 5 of the Notice of the Research Program in Sanitation - PROSAB-5, aimed to study the theme 'Characterization and study of alternative ways of treating sludge from septic tanks in the city of Natal, RN', proposing to evaluate the performance of the use of stabilization ponds as a system to handle waste from septic tanks exhausted. A series of lakes studied belong to one of the largest clean-pit of Natal, consisting of two anaerobic ponds, one facultative and maturation, and a tank disinfection, the wastewater being released in the Potengi River. Samples were collected between the months of October 2007 to October 2008, at six points previously defined and judged as more appropriate to what is proposed study. The analysis results in field and laboratory showed the most significant removal of COD (88.93%), total suspended solids (94.87%), organic nitrogen (66.87%) and thermotolerant coliforms (99.88%). Some results have not reached the expected because the system under study had operating problems that have undermined the efficiency of the reactors

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Pirangi beach is located in the eastern coastline of Rio Grande do Norte state, in the municipality of Parnamirim and Nísia Floresta. In it flow into Pirangi Watershed (PW), whose water receives large amounts of pollutants, mainly domestic and industrial sewage from districts where pass the rivers that consist it, compromising, thus, the bathing water quality of the Pirangi beach. Bearing in mind the importance of water sanitary quality to ensure an environment that no present risk to the bathers s health, this work had as main objective to assess the influence of the PW s waters in the bathing water quality of the Pirangi beaches. To that end, were made collections of water in the beaches and in the rivers with the intention of quantify the fecal contamination indicators thermotolerant coliforms and enterococci, to then classify the conditions of bathing water quality according with the CONAMA Resolution number 274 of 2000. For the purposes greater knowledge about the health conditions of the Beaches Pirangi and about the influence the PW s waters exert on it, was done parallely to the study of the water quality, an investigation of the sand sanitary quality. Furthermore, it was made an evaluation of the PW s Water Quality through Water Quality Index (WQI). Starting from the results obtained in the research present was possible to verify, among other aspects, that the entry of the PW s waters in the Pirangi beaches exerts direct influence in the bathing water quality of the same ones, being the North Pirangi beach (point tracking PA-02) the most influenced. There was noticed also a significant reduction in the conditions of bathing water quality of the beaches in the rainy season. However, the precariousness do sewerage system of the Natal metropolitan region and the absence of a right system of treatment an final disposal of domestic sewage and industrial are the main factors responsi le for deterioration of the PW s Water Quality, and as a consequence, compromising the bathing water quality of the Pirangi beaches

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigates a new treatment system of wastewater by anaerobic and aerobic biological filters for nitrogen modification. The main objective of this study was evaluate, on a pilot scale, quantitatively and qualitatively the bacterian nitrifying community in a experimental sewage treatment system made by aerobics biological filters in series, in search of figure out the dynamic of nitrogen modification process. It was collected and laboratorial analysed microbiologically, regarding NMP of Nitrosomonas e Nitrobacter, and physical-chemically considering nitrogen sequence. We conclude that: the association in aerobic biological filters under nutrition controlled conditions and oxygen level allows the appearance of bacterian community responsible for the nitrogen modification; the method used, despite its limitations, provided the selection of autotrophic nitrifying microorganisms, allowing the identification of Nitrosomonas and Nitrobacter; the flow direction tested in the experimental unit did not affect the nitrifying bacterial community, certainly because they were kept drowned and did not occur flow speed that could breake the formed biomass; the nitrification process happened in aerated biological filters in all phases of the research, comproved by microbiological tests; in the third phase of the research the increase of the oxygen rate was significant for the nitrificant bacterian community in the aerate biological filters, allowing its growth, occurring relation between the efficiency of nitrification system and the quantity of organisms responsible for this process; the conduit used in aerated biological filters showed satisfactory performance support material to the nitrifying bacteria development

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Only 32% of the population of Natal is attended by sewage, while the remaining population use pits and septic tanks. The characterization of the contents of septic tanks and pits contributes to the performance of such system and may guide the decision on treatment of these contents. The main of this research is to characterize the contents of interior residential pits and septic tanks in the greater Natal, with the following specific goals: to develop and manufacture a sampler capable of collecting a representative sample of the entire column (the surface scum, the clarified liquid and sludge bottom); to compare the contents of the tanks with the pits; to compare the contents of the septage from vacuum trucks; to relate the composition content with socioeconomic characteristics of households; to compare the content in both chambers of the septic tanks in series; to assess the situation of the content before and six months after the cleanness; and ultimately propose a pilot scale plant for treatment of septage. Once the sampler was developed, samples were collected within 14 septic tanks and 10 pits in many districts of Natal. Medians of the 24 systems were obtained: temperature, pH, conductivity, oil and grease, total solids, total suspended solids and sediments of 28.0 °C, 6.95; 882 mS/cm, 75.2 mg/L; 10,169 mg/L, 6,509 mg/L and 175 mL/L respectively; 111.0 mgN/L for ammonia, 130.5 mgN/ L for organic nitrogen, 0.2 mgN/L for nitrite, 0.4 mg/L for nitrate; 8935 mgO2/L for COD, 29.2 mgP/L for total phosphorus, thermotolerant coliforms from 9.95 E +06 CFU/100mL helminth eggs and 9.2 eggs/L with a maximum concentration of 688 eggs/L and minimum of 0 eggs/L. Medians of organic nitrogen and TKN were significantly different between groups of tanks and pits. The systems with cleanness gap from 11 and 20 years presented the higher concentrations for most variables. The effluent from the toilets and bathrooms participate more effectively in contributing fractions of solids, alkalinity, nitrogen, COD, total phosphorus, thermotolerant coliforms and helminth eggs. The systems used by socioeconomics class with income from R$ 3,700.00 to R$ 7,600.00, presented higher concentrations for COD, nitrogen, solids and helminth eggs. The first of the two chambers had always presented higher concentrations over the second compartment. The analysis of variance for most variables, showed that the values of septic tanks, pits and septage from vacuum trucks belong to the same group. In the samples taken after cleanness, the median of pH and temperature increased, while alkalinity, COD, organic nitrogen, total phosphorus, ammonia and helminth eggs decreased. The oils and greases and thermotolerant coliforms had slightly varied due to the continuous release of sewage into the systems that maintained their steady state concentrations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although the good performance in organic matter and suspended solids removal, the anaerobic reactors are unable to remove ammonia nitrogen from sewage, which makes indispensable to include a step of post-treatment for removal of ammonia or nitrate as necessary. This paper presents the performance of a new variant technology, where the nitrification unit, preceded by anaerobic units, is a submerged aerated biological filter, without continuous sludge discharge in their daily operation. The oxygenation system is very simple and inexpensive, consisting of perforated hoses and compressors. The anaerobic reactors are a septic tank with two chambers followed (8.82 m³) and two parallel anaerobic filters (36 m³ each) filled with ceramic bricks and conics plastic parts. Both followed aerated filters were filled with cut corrugated conduit. The study evaluated the behavior of the system with constant domestic sewage flow (10 m³/d) and different aeration conditions, are these: stage 01, when applied air flow of 0.01 m³ air/min in both aerated filter; stage 02, remained in the initial air flow rate in the second aerated filter and increased at the first to 0.05 m³ air/min; at last, at last, in stage 03, the air flow rate of first aerated filter was 0.10 m³ air/min and on the second remained at 0.01 m³ air/min. The filter FA1 received load of 0.41 kg COD/m³.d, 0.37 kg COD/m³.d and 0.26 kg COD/m³.d on phases 01, 02 and 03, respectively. The FA2 received loads of 0.25 kg COD/m³.d, 0.18 kg COD/m³.d and 0.14 kg COD/m³.d on phases 01, 02 and 03, respectively. During stage 01, were found the following results: 98% removals of BODtotal and 92% of CODtotal, with effluent presenting 9 mg/L of BODtotal final average and 53 mg/L of CODtotal average; suspended solids removals of 93%, with a mean concentration of 10 mg/L in the final effluent; 47% reduction of ammonia of FA2 to FAN 's, presenting average of 28 mg NNH3/ L of ammonia in the effluent with; the dissolved oxygen levels always remained around 2.0 mg/L. During stage 02, were found removals of 97% and 95% to BODtotal and suspended solids, respectively, with average final concentrations of 8 and 7 mg/L, respectively; was removed 60% of ammonia, whose final concentration was 16.3 mg NNH3/ L, and nitrate was increased to a final average concentration of 16.55 mg N-NO3/L. Finally, the stage 03 provided 6 mg/L of DBOtotal (98% removal) and 23 mg/L of CODtotal (95% removal) of final effluent concentrations average. At this stage was identified the higher ammonia oxidation (86%), with final effluent showing average concentration of 6.1 mg N-NH3/L, reaching a minimum of 1.70 mg N-NH3/L. In some moments, during stage 03, there was a moderate denitrification process in the last aerated filter. The average turbidity in the effluent showed around 1.5 NTU, proving the good biomass physical stability. Therefore, the results demonstrate the submerged biological filters potential, filled with high void ratio material (98%), and aerated with hoses and compressor adoption, in the carbonaceous and nitrogenous matter oxidation, also generating an effluent with low concentration of solids

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study that resulted in this dissertation was developed at OU RNCE PETROBRAS, in Natal, which implemented a project of rational use and reuse of water, including use of wastewater from a Sewage Treatment Plant (STP) already in place, diluted with water from own wells for irrigation of green area of the building complex corporate enterprise. Establish a methodology that can serve as guidelines for future projects controlled reuse of water like this was the objective of this research. Been proposed, implemented and evaluated three instruments of sanitary and environmental control: 1) adaptation of sewage treatment plant and quality control of the treated effluent 2) analysis of soil-nutrient interaction in the irrigated area, 3) knowledge of the local hydrogeology, especially with regard to the direction of flow of the aquifer and location of collection wells of Companhia de Águas e Esgotos do Rio Grande do Norte (CAERN) situated in the surroundings. These instruments have proven sufficient and appropriate to ensure the levels of sanitary and environmental control proposed and studied, which were: a) control of water quality off the STP and the output of the irrigation reservoir, b) control of water quality sub surface soil and assessment of progress on soil composition, c) assessment of water quality in the aquifer. For this, we must: 1) establishing the monitoring plan of the STP and its effluent quality sampling points and defining the parameters of analysis, improve the functioning of that identifying the adequacy of flow and screening as the main factors of operational control, and increase the efficiency of the station to a relatively low cost, using additional filters, 2) propose, implement and adapt simple collectors to assess the quality of water percolating into the soil of the irrigated area, 3) determine the direction of groundwater flow in the area study and select the wells for monitoring of the aquifer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The detention and infiltration ponds of urban drainage system has function to protect the population from undesirable effects of floods. In general these ponds are not completly used and it potential is wasted. As it are disseminated at different places at cities it can reduce costs with water transport and permit water preservation of best quality. Some it utilities includes use in green areas irrigation, industrial among than cooling towers and boiler, soil compaction, cleaning urban road, pisciculture and fire fighting system. The quality these water is influenced by anauthorized sewage in the drainage system. This study was performed in six detention and infiltration ponds at drainage system of Natal, which aim was to verify the non-portable use these ponds on urban environment. As indirect aim would to incentive the water utilization these ponds as a water source to another uses in urban environment. These ponds represents the characteristics of detention and infiltration of Natal city and consequently of Brazil. As the water quality, the ponds presents following characteristics: three has apparently good quality, other showed intermediate condition and two had water polluted. Were performed twenty sample in each ponds and the following parameters assessed: pH, temperature, dissolved oxygen, turbidity, electrical conductivity, coliform thermotolerant, ammonia, organic nitrogen, TKN, nitrate, total phosphorus and alkalinity, bicarbonate, chloride, total hardness, calcium and magnesium hardness, total solids, TSS, TDS, COD and SAR°. To utilization on pisciculture we recommend use in ponds which presents the best quality. Only one pond presented higher pollutants and it not being appropriated for use in cooling tower. The content of solids suspension restricted the water use in all ponds in boilers. As water use in soil compaction, cleaning urban road and fire fighting system the water from these ponds are not appropriated. However, the recommended limits from literature are to domestic sewage, due to this, the parameters are restrictive to diminish the sanitary risk that could be offered with it utilization. The infiltration velocity of water these assessed ponds restrict a moderato use, however the effects are potentiated only in soil less sandy, which not occur in Natal. It is recommend the unrestricted irrigation utilization in ponds with best quality of water, and a restricted irrigation to ponds with worst quality of water. As load of pollutants, it is recommended a complementary treatment in those ponds whit higher load to diminish sanitary risks. In only one pond was found one helminth eggs and due to the convention formula of results, it was found for all ponds less than 1 helminth/liter eggs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stabilization pond system consisting in more sewage treatment used in Rio Grande do Norte (RN), Brazil, representing about 90% of all systems. Fecal bacteria are removed mainly facultative ponds and in maturation ponds. Many factors influence bacterial decay, such as the levels of pH and DO, temperature, light intensity, HDT and nutrient availability. The bacterial decay rate (Kb) is calculated considering many variables, but the hydraulic regime is a significant influence for microorganisms removal, and the dispersed flow which best characterizes a stabilization pond. However, some authors developed equations for the Kb accordant plug flow and complete mixing. This research study aimed to evaluate the bacterial decay of fecal coliform and Enterococcus sp. in stabilization ponds designed to treat domestic sewage, full-scale, in RN. All systems have assessed pretreatment, a facultative pond (LF) followed by two maturation (LM1 and LM2). The parameters availed were: temperature, pH, DO, BOD5, COD, fecal coliform, Enterococcus sp., Chlorophyll a, total suspended solids, fixed and volatile. In general, there were not significant differences for pH, DO and temperature in the ponds, except for the new systems, since they have low flow and hydraulic loads. The removal of organic matter in the ponds was low, about 70%, and nearly all are overloaded organic and operational problems. The bacterial removals were low, with average 96% for LF for fecal coliform, and 98% for Enterococcus sp.; LM1 were in itself a removal for fecal coliform about 71%, and 81% for Enterococcus sp.; LM2 have efficiency of 69% for fecal coliform, and 68% for Enterococcus sp. The equation proposed by Von Sperling (1999), according to the dispersed flow regime, generated empirical values of Kb more approximate to calculated values of Kb. On average, the calculated Kb to coliforms in the LF was 0.31 d-1, and for both maturation ponds were 0.35 d-1. For Enterococcus sp. the average was 0.40 d-1 for LF, 0.55 d-1 for LM1, and 0.58 d-1 for LM2. These results also showed that the Kb obtained in full-scale systems are smaller than those found in pilot-scale ponds. Moreover, one can say that the equation proposed by Marais (1974), according to the complete-mix regime, overestimates Kb. Actual results of Kb indicated that fecal coliforms are more resistant to adverse conditions present in stabilization ponds than Enterococcus sp., therefore, an indicator of microbiological safety and efficiency. The factors significant interventions in the rate of bacterial decay were concentrations of COD, the organic loading and HDT. The few Kb relationship between pH, DO and temperature were not significant. Finally, we conclude that it s essential to correct operation and maintenance, for not performing these activities is one of the main factors contributing to low rates of bacterial decay.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wetlands systems are considered nowadays as a treatment method that uses simple, easy operation and low cost technology, which has been used in various parts of the world and also in Brazil. Used alone or as a complement to other types of treatment systems, once it effectively removes nutrients, pathogens and other pollutants in the water. Due to the high complexity found in wetlands, making it difficult to predict the response of the system to treat wastewater, one should consider as ideal to base the sizing of the wetland system over the necessary removal of this parameter instead of scaling it from empiricism. The study was conducted to determine the coefficient of bacterial decrease in the Wetland unit located at Ponta Negra Station Sewage Treatment, located in Natal, the coastal region of Rio Grande do Norte. The most representative model to determine the bacterial decrease in this system was the one from Chick for hydraulic piston system. Kb of 0.37 d-1 were found for the flow rate of 15m³/d, while for the system operating at maximum design flow, 30m³/d, the Kb of 0.98 d-1 was found

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stabilization pond is the main technology used for treatment wastewater, in northeast Brazil, due to lower cost of deployment, operation and maintenance compared to other technologies. Most systems of stabilization ponds has been in operation for some time, on average 10 years of operation, receiving high organic loads and do not have good removal efficiencies of the main parameters for which have been designed. Therefore it is necessary to work to quantify the efficiency of current systems. This study evaluated the biodegradability of organic matter in raw sewage, the removal of organic matter in reactors and determination of the kinetic constant removal of organic matter (k), both in reactors and in raw sewage, based on the analysis made in the laboratory and through mathematical methods proposed in the literature, in nine systems stabilization ponds, located in Rio Grande do Norte. In relation the degradation kinetics in stabilization ponds, it was observed that many papers published in the literature were obtained in pilot-scale systems, which often, due to the action of external factors such as wind and temperature, these can t be considered as a reference in the analysis of the kinetic constant K, so the need for more research into systems of scale. This study had three distinct phases and simultaneous, routine monitoring, study of the daily cycle and the determination of kinetic constant of degradation of organic matter (K). The monitoring showed that the removal efficiencies of organic matter on most systems were lower than suggested by the literature, the best efficiencies of around 76% (BOD) and 72% (COD) and the worst of the order of 48% (BOD) and 55% (COD). The calculation of K in raw sewage (Ke) was within the range of variation expected in the literature (0.35 to 0.60 days-1). Already for the results obtained for K in the reactors (Kr), there were well below the values recommended in the literature (0.25 to 0.40 d-1 for complete mix and from 0.13 to 0.17 d-1 for flow dispersed), in line with the overloads that organic systems are subject

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The simulation of SES-Natal Ponta Negra: mitigation of environmental risks and predictive maintenance strategy was developed in the context of several operational irregularities in the pumping stations and sewage systems in the system Ponta Negra. Thus, the environmental risks and complaints against the company due to overflows of sewage into the public thoroughfare became common. This neighborhood has shown in recent years an increase of resident higher than the initial expectation of growth. In this sense presumed the large population growth and generation of sewers higher than expected, associated to the use of corrective maintenance and misuse of the system may be the main causes of operational failures occurring in the SES. This study aimed at analyzing the hydraulic behavior of SES Ponta Negrathrough numerical simulation of its operation associated to future scenarios of occupation. The SES Ponta Negra has a long lengthof collection networks and 6 pumping stations interconnected, being EE 1, 2, 4 coastal way, and beach Shopping interconnected EE3 to receives all sewers pumped from the rest pumping station and pumped to the sewage treatment station of neighborhood which consists of a facultative pond followed by three maturation ponds with disposal of treated effluent into infiltration ditches. Oncethey are connected with each other, the study was conducted considering the days and times of higher inflow for all lifts. Furthermore, with the aim of measuring the gatherer network failures were conducted data survey of on the networks. Thephysical and operational survey data was conducted between January/2011 and janeiro/2012. The simulation of the SES was developed with the aim ofdemonstrating its functioning, eithercurrently and in the coming years, based in population estimates and sewage flow. The collected data represents the current framework of the pumping stations of the SES Ponta Negra and served as input to the model developed in MS Excel ® spreadsheet which allowed simulating the behavior of SES in future scenarios. The results of this study show thatBeach Shopping Pumping Station is actually undersized and presents serious functioning problemsthatmay compromise the environmental quality of surrounding area. The other pumping stations of the system will reach itsmaximum capacity between 2013 and 2015, although the EE1 and EE3 demonstrateoperation capacity, even precariously, until 2017. Moreover, it was observed that the misuse of the network system, due to the input of both garbage and stormwater, are major factors of failures that occur in the SES. Finally, it was found that the corrective maintenance appliance, rather than predictive,has proven to beinefficient because of the serious failuresin the system, causing damage to the environment and health risks to users