26 resultados para clima


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The farm’s rural dwellings of creation from the Seridó Potiguar microregion, built in the nineteenth century, became a reference by its vernacular character, i.e. these buildings, besides having recognized relevance to the identity of the region, they are adapted to the conditions of the place in many aspects (economic, cultural, construction, physical, et.) and consist in protective spaces in relation to hostile characteristics of Seridó’s climate. Considering the above premise, the following question arises: What characteristics of the nineteenth century Seridó Potiguar’s cattle farms are crucial for them to be a protective space in relation to the semiarid climate? In order to answer the question, this research aim to identify which particularities of the Seridó’s farmhouses that contribute to adaptability in these buildings to semiarid climate, as protection environments; and contribute to the stock valuation of the architectural heritage concerned. Therefore, procedures were adopted divided into two stages. Were first identified the recurring characteristics in the studied buildings, through typological study performed from existing inventories (DINIZ, 2008; FEIJÓ, 2002; IPHAN, 2012). To define the type it worked up with the concept that merges Durand’s analytical typology that identifies the similarities and differences to classify buildings, having the character of historical survey and architectural documentation, with the definition proposed by Argan (1963) that the type is not defined a priory, but the deduction from a number of illustrative cases which have formal and functional similarity with each other. Then worked up in a sample of five different types with each other, defined by the possibility of access to the interior of the houses, proximity to other copies, good state of conservation and preservation. The contemplated farms were: Pitombeiras, Agenus e Garrotes in Acari’s town, and the municipality of Caicó, Palma and Penedo. The second stage consists of the architectural survey, photographic record, digital three-dimensional modeling (aiming to expand the existing documentation and registration) and thermal monitoring over approximately a representative day in five farmhouses, relating the thermal performance of the houses with their individual characteristics. The selected variables for analysis monitoring are based on the thermal comfort adaptive model (SPAGNOLO and DE DEAR, 2003 apud NEGREIROS, 2010). The characteristics of the houses were analyzed as meeting the passive thermal conditioning strategies recommended by NBR 15220 (ABNT, 2005), for the bioclimatic zone 7 where the municipalities of Caicó and Acari are located. The house’s analysis of the operating temperatures revealed that 90% of the times of day the environments are within the comfort range. The farmhouses, which had a higher degree of compliance with recommended bioclimatic strategies, had the best thermal performance. In environments (usually the kitchen and rooms with low ceiling heights, exposed to west radiation) which still had discomfort hours, the thermal comfort can be reached with air movement approximately 1,0 m/s.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The farm’s rural dwellings of creation from the Seridó Potiguar microregion, built in the nineteenth century, became a reference by its vernacular character, i.e. these buildings, besides having recognized relevance to the identity of the region, they are adapted to the conditions of the place in many aspects (economic, cultural, construction, physical, et.) and consist in protective spaces in relation to hostile characteristics of Seridó’s climate. Considering the above premise, the following question arises: What characteristics of the nineteenth century Seridó Potiguar’s cattle farms are crucial for them to be a protective space in relation to the semiarid climate? In order to answer the question, this research aim to identify which particularities of the Seridó’s farmhouses that contribute to adaptability in these buildings to semiarid climate, as protection environments; and contribute to the stock valuation of the architectural heritage concerned. Therefore, procedures were adopted divided into two stages. Were first identified the recurring characteristics in the studied buildings, through typological study performed from existing inventories (DINIZ, 2008; FEIJÓ, 2002; IPHAN, 2012). To define the type it worked up with the concept that merges Durand’s analytical typology that identifies the similarities and differences to classify buildings, having the character of historical survey and architectural documentation, with the definition proposed by Argan (1963) that the type is not defined a priory, but the deduction from a number of illustrative cases which have formal and functional similarity with each other. Then worked up in a sample of five different types with each other, defined by the possibility of access to the interior of the houses, proximity to other copies, good state of conservation and preservation. The contemplated farms were: Pitombeiras, Agenus e Garrotes in Acari’s town, and the municipality of Caicó, Palma and Penedo. The second stage consists of the architectural survey, photographic record, digital three-dimensional modeling (aiming to expand the existing documentation and registration) and thermal monitoring over approximately a representative day in five farmhouses, relating the thermal performance of the houses with their individual characteristics. The selected variables for analysis monitoring are based on the thermal comfort adaptive model (SPAGNOLO and DE DEAR, 2003 apud NEGREIROS, 2010). The characteristics of the houses were analyzed as meeting the passive thermal conditioning strategies recommended by NBR 15220 (ABNT, 2005), for the bioclimatic zone 7 where the municipalities of Caicó and Acari are located. The house’s analysis of the operating temperatures revealed that 90% of the times of day the environments are within the comfort range. The farmhouses, which had a higher degree of compliance with recommended bioclimatic strategies, had the best thermal performance. In environments (usually the kitchen and rooms with low ceiling heights, exposed to west radiation) which still had discomfort hours, the thermal comfort can be reached with air movement approximately 1,0 m/s.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PEDRINI, Aldomar; SZOKOLAY, Steven. Recomendações para o desenvolvimento de uma ferramenta de suporte às primeiras decisões projetuais visando ao desempenho energético de edificações de escritório em clima quente. Ambiente Construído, Porto Alegre, v. 5, n. 1, p.39-54, jan./mar. 2005. Trimestral. Disponível em: . Acesso em: 04 out. 2010.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study is to investigate if exist relationship between organizational culture and the organizational climate, having as research s locus three dairy industries in the Rio Grande do Norte State. As such, an exploratory-descriptive and conclusive-causal study, with a sample composed of 211 employees of all firms hierarchical levels was undertaken. By way the data collection, the employees personal characteristics, the predominant organizational culture profile and the predominant organizational climate in the industries researched were identified. In order to analyse the organizational culture, the Competing Value Model (CAMERON; QUINN, 2006), with adaptations by Santos (1998, 2000), was used. In order to analyse the organizational climate, the Organizational Climate Measurement Scale, proposed by Martins (et al., 2004, 2008), with modifications, was used. The data were submitted to quantitative statistical analyses, firstly to the set of firms and afterwards to the firms alone, that permitted arrival to the following conclusions: the cultural profiles was met in a balanced way in the researched organizations, with emphasis to clan culture and market culture profiles; the researched organizations have a good organizational climate, based in the Martins (2008) classification, with emphasis to boss and organization s support and physical comfort , being these factors coherent whit the clan culture profile; the personal variables are correlated with the cultural profiles and with the organizational climate factors, however, each organization show its singular form of relation; and the cultural profiles showed influence on organizational climate factors. Thus, the results permitted to conclude that there are relations between the cultural profiles and the organizational climate factors in the researched organizations

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nowadays, evaluation methods to measure thermal performance of buildings have been developed in order to improve thermal comfort in buildings and reduce the use of energy with active cooling and heating systems. However, in developed countries, the criteria used in rating systems to asses the thermal and energy performance of buildings have demonstrated some limitations when applied to naturally ventilated building in tropical climates. The present research has as its main objective to propose a method to evaluate the thermal performance of low-rise residential buildings in warm humid climates, through computational simulation. The method was developed in order to conceive a suitable rating system for the athermal performance assessment of such buildings using as criteria the indoor air temperature and a thermal comfort adaptive model. The research made use of the software VisualDOE 4.1 in two simulations runs of a base case modeled for two basic types of occupancies: living room and bedroom. In the first simulation run, sensitive analyses were made to identify the variables with the higher impact over the cases´ thermal performance. Besides that, the results also allowed the formulation of design recommendations to warm humid climates toward an improvement on the thermal performance of residential building in similar situations. The results of the second simulation run was used to identify the named Thermal Performance Spectrum (TPS) of both occupancies types, which reflect the variations on the thermal performance considering the local climate, building typology, chosen construction material and studied occupancies. This analysis generates an index named IDTR Thermal Performance Resultant Index, which was configured as a thermal performance rating system. It correlates the thermal performance with the number of hours that the indoor air temperature was on each of the six thermal comfort bands pre-defined that received weights to measure the discomfort intensity. The use of this rating system showed to be appropriated when used in one of the simulated cases, presenting advantages in relation to other evaluation methods and becoming a tool for the understanding of building thermal behavior

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research consists in studying the influence of the various type of construction systems of roofs with their energy efficiency as well as on the cost benefit for the commercial buildings on the temperatures condition of the city of Natal/RN. The main goal of this research is to analyze the cost benefit of the construction systems of roofs available on the market, taking into consideration the energy efficiency of the commercial buildings artificially air conditioned in order to be used by the projectors and to be adequated to the temperatures condition of the city of Natal/RN. The method of valuation of the cost benefit of roof systems consists in six steps: Features and simulation of the reference building; Analyze of sensitivity; Analyzes, features and simulation of alternatives of roof construction systems; Analyze of the cost of implementation; Analyze of the benefits of the alternatives comparing to the base case; And finally the analyze of the cost benefit. The model type chosen as reference was stores with pre molded buildings and system of roof with fiber ciment and ceiling . The thermal results showed the influence of the roof system on the energy efficiency of the building. The Final results of the simulations of the alternatives comes to a conclusion that the absortance is the variable that presents the best cost benefit relation and the reduction on the thermal transmittance still has limitations because of the high cost

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The assessment of building thermal performance is often carried out using HVAC energy consumption data, when available, or thermal comfort variables measurements, for free-running buildings. Both types of data can be determined by monitoring or computer simulation. The assessment based on thermal comfort variables is the most complex because it depends on the determination of the thermal comfort zone. For these reasons, this master thesis explores methods of building thermal performance assessment using variables of thermal comfort simulated by DesignBuilder software. The main objective is to contribute to the development of methods to support architectural decisions during the design process, and energy and sustainable rating systems. The research method consists on selecting thermal comfort methods, modeling them in electronic sheets with output charts developed to optimize the analyses, which are used to assess the simulation results of low cost house configurations. The house models consist in a base case, which are already built, and changes in thermal transmittance, absorptance, and shading. The simulation results are assessed using each thermal comfort method, to identify the sensitivity of them. The final results show the limitations of the methods, the importance of a method that considers thermal radiance and wind speed, and the contribution of the chart proposed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This master thesis introduces assessment procedures of daylighting performance in office rooms with shaded opening, recommendations for Natal-RN (Latitude 05,47' S, Longitude 35,11' W). The studies assume the need of window exterior shading in hot and humid climate buildings. The daylighting performance analyses are based on simulated results for three levels of illuminance (300,500 e 1000 lux) between 08h00 e 16h00, in rooms with 2,80 m height, 6 m large and 4 m, 6 m e 8 m depths, with a centered single opening, window wall ratio (20%, 40% e 60%), four orientations (North, East, South and West), and two types of sky (clear and partially cloudy). The sky characteristics were statistically determined based on hourly data from INPE-CRN solar and daylighting weather station. The lighting performance is resulted from dynamic computer simulation of 72 models using Troplux 3.12. The simulation results were assessed using a new parameter to quantify the use of interior daylighting, the useful percentage of daylight (PULN), which corresponds to the time fraction with satisfactory light, in accordance with the illuminance design. The passive zone depths are defined based on the PULN. Despite the failures of illuminance data from the weather station, the analyses ratified the high potential of daylighting for shaded rooms. The most influential variables on the lighting performance are the opening size and the illuminance of design, while the orientation is a little influential

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study deals with the relationship between urban vegetation and climate. The process whereby the Parque das Dunas a 1,172 ha green area in the city of Natal, State of Rio Grande do Norte exerts influence on the climate of the city is analyzed. The hypothesis on which the present work rests is that the green area referred to acts upon the climate of the city. The study is based on the analysis of climatic factors and elements of this green area and of the city of Natal. In order to give rise to final recommendations, a methodology grounded on a quantitative and qualitative standpoint has been used. The data were collected both within and without the limits of the Parque das Dunas area. Secondary and primary data resulting from the measurements taken by the researcher and her work group have been used. The aim was to contribute to the understanding of the influence of vegetation on the climate of a city having a warm and humid climate. A historical and environmental characterization of the Parque das Dunas was then sought. The local climatic factors and the elements of the climate have been studied within the scope of the city of Natal. A comparative study between the climatic elements within and without the limits of the Parque das Dunas area from the survey of technical data and the systematization of the information collected has been made, aiming at proposing a set of bioclimatic recommendations for the urban design in Natal. The results of such work allowed for the validation of the important role that the Parque das Dunas plays in the climate of Natal. This has led to the acknowledgement of the relevance of the green areas on the climate of cities. They bring about important benefits to the process of rendering agreeable the climate in the urban environment by providing pleasant microclimates that give a valuable contribution to the environmental comfort of urban nuclei having the same size of Natal

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Natural air ventilation is the most import passive strategy to provide thermal comfort in hot and humid climates and a significant low energy strategy. However, the natural ventilated building requires more attention with the architectural design than a conventional building with air conditioning systems, and the results are less reliable. Therefore, this thesis focuses on softwares and methods to predict the natural ventilation performance from the point of view of the architect, with limited resource and knowledge of fluid mechanics. A typical prefabricated building was modelled due to its simplified geometry, low cost and occurrence at the local campus. Firstly, the study emphasized the use of computational fluid dynamics (CFD) software, to simulate the air flow outside and inside the building. A series of approaches were developed to make the simulations possible, compromising the results fidelity. Secondly, the results of CFD simulations were used as the input of an energy tool, to simulate the thermal performance under different rates of air renew. Thirdly, the results of temperature were assessed in terms of thermal comfort. Complementary simulations were carried out to detail the analyses. The results show the potentialities of these tools. However the discussions concerning the simplifications of the approaches, the limitations of the tools and the level of knowledge of the average architect are the major contribution of this study

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This master thesis aims to assess the influence of the design decisions on the energy building performance of hotels. The research is based on the integration of field study and computer simulation. Firstly, a detailed field study is carried out to identify the characteristics of hotels in Natal, Rio Grande do Norte. The items assessed are occupancies, light and equipment densities, types of air conditioning, total and monthly energy consumption, among others. A second and more comprehensive field study is carried out to identify the range of occurrence of architectural variables, with a larger number of buildings. A base case is modelled in VisualDOE, based on the first field study. Then, a first set of simulations are run to explore the sensitivity of the variables on the energy consumption. The results analyses were the base of a second set of simulations, which combined the most influential variables. The results of 384 models were assessed, and the impacts of design decisions were quantified. The study discusses tendencies and recommendations, as well as the methods advantages and disadvantages