38 resultados para adaptive thermal comfort models
Resumo:
The recent tendency to utilize parking lots for other purposes has demonstrated that more time has been spent by visitors, mainly in great cities. Therefore, this paper investigates the thermal comfort and the air quality indoors in areas specifically used as parking lots by analyzing the direct relation between such environments and vehicular pollution. The thermal comfort and the quality of air indoors in parking lots with different architectonic typology (ground-floor and underground) are also studied, aiming to contribute to the proposition of suitable new areas designated to human usage. Field research was done, in two distinct periods within different weather conditions (January and July) in, two naturally cooled, parking lots located in Natal - RN. The internal environment agents were measured by using tools for air temperature, humidity, speed and direction; interviews with employees and visitors and chemical analysis through appropriate tools to analyze specific material, carbon monoxide and ozone. The results showed that chemical agents densely concentrate mostly in the closed parking space, aggravated by weather conditions, which dissatisfied the visitors. Still, it was shown that architectonic typology, alongside topographical aspects compromise internal environmental conditions, which increases the retention of pollution, leading to dissatisfactory thermal comfort levels and becoming less suitable for usage by visitors considering air and thermal comfort aspects. Consequently, they are not suitable for human stay due to the poor quality of the indoor air
Resumo:
This study was intended to investigate how the urban form has been influencing the changes in the climate of the city and make a correlation between the climate and the thermal sensation of the users of open spaces. The research was developed in the district of Petrópolis in Natal/ RN whose occupation has been almost consolidated. Among other reasons, this district was selected because it was planned considering the environmental aspects of comfort. The methodologies used are based on KATZSCHNER (1997) and OLIVEIRA (1988) studies, which suggest the drawing and analysis of maps of the area under study, including topography, height of the buildings, land use, green areas, and types of soil pavement, as well as measurement of the environmental variables: air temperature, relative humidity, direction and wind speed for a comparative study. As part of this, study local users of the district were interviewed about their thermal sensations in open spaces. For the statistical analysis, data was collected at 10 distinct points characterized by BUSTOS ROMERO (2002), being 8 within the district and 2 at different places (outside the district), at climatologic stations, in 3 periods (August/2000, January/2002 and June/2002), for 4 consecutive days for each measurement (from Sunday to Wednesday) at the time of lower and higher temperatures in the city, 6:00 am and 1:00 pm, respectively. At the same time interviews were carried out with users of the open spaces in the area, totaling 171 valid formularies. The urban form showed a rather leveled topography, great diversity of land use and height of the buildings, with the existence of an area mostly occupied with high buildings, very little green area and soil practically impermeable. The statistical analysis showed high temperature and humidity levels. The wind direction is predominantly Southeast with extremely variable speeds. When the data from this district is compared with the data from other areas in the city and its outskirt, it was observed that this district is hotter and less ventilated than the others; besides, most users said that they felt uncomfortable in the local environmental conditions. The results of the analysis generated a zoning for the district with recommendations for soil occupation. The profile of the user was defined regarding the thermal comfort, as well as some discussion about the comfort parameters, including the proposal of limiting areas of temperature and humidity for the thermal comfort in the open spaces
Resumo:
Natural air ventilation is the most import passive strategy to provide thermal comfort in hot and humid climates and a significant low energy strategy. However, the natural ventilated building requires more attention with the architectural design than a conventional building with air conditioning systems, and the results are less reliable. Therefore, this thesis focuses on softwares and methods to predict the natural ventilation performance from the point of view of the architect, with limited resource and knowledge of fluid mechanics. A typical prefabricated building was modelled due to its simplified geometry, low cost and occurrence at the local campus. Firstly, the study emphasized the use of computational fluid dynamics (CFD) software, to simulate the air flow outside and inside the building. A series of approaches were developed to make the simulations possible, compromising the results fidelity. Secondly, the results of CFD simulations were used as the input of an energy tool, to simulate the thermal performance under different rates of air renew. Thirdly, the results of temperature were assessed in terms of thermal comfort. Complementary simulations were carried out to detail the analyses. The results show the potentialities of these tools. However the discussions concerning the simplifications of the approaches, the limitations of the tools and the level of knowledge of the average architect are the major contribution of this study
Resumo:
This dissertation of master degree was presented to Post-Graduation Program in Architecture and Planning at UFRN, Brazil. It evaluates 45 one-family housings in the Metropolitan Area of Recife, whose architects consider them to be in conformity with the recommendations contained in Armando de Holanda's book: A Guide to build in the Brazilian Northeast: Architecture as a pleasant place in the sunny tropics , published in 1976 by UFPE. For a long time, it used to be reference in many Architecture and Planning Schools of the Northern Region of Brazil. The research s methodological procedures are based on the Post- Occupancy Evaluation (P.O.E.) with emphasis on the users' thermal comfort of the houses that make part of the sample. Therefore, it has been done technical analyses of the projects, when possible; interviews with the architects; building s inspections; and form applications to the users. The collected data analysis was based on the project recommendations of Holanda s book, they can be synthesized in the principle of Building Leafy". It can not be affirmed that all the houses present the recommendations contained in the guide, but, in many different ways, they exist, sometimes more intensely and sometimes more shyly. However, it can be noticed that in the 45 projects, that the architects perceived the importance of "Building Leafy" on the climatic reality of the Metropolitan Region of Recife
Resumo:
The present work concerns the use of shade elements as architectural elements to block sunlight in public buildings. In a city like Natal, (5o South) the incidence of sunrays in any type of design should be a constant concern for all the architects. Besides, this habit of avoiding insolation in the environment is not a common practice. Within this context, the present work has the objective to dig deep into the knowledge of solar control, studying some cases and verifying its function according to the orientation and the original design of the building, having in mind if the shade elements usually used in the region have achieved their purpose of providing protection against the incidence of direct sun rays. This study considers the position of the shade element (horizontal and vertical), the angle formed between them and the respective facades, and the local of the buildings in relation to their orientation during the summer, winter and equinox solstice. As supporting instruments the solar map of the city and the protractor, for measuring shade angles, were used. It was concluded that in all the cases studied, it was not possible to obtain the maximum use of the elements. It was verified that the best type of shade element (more efficient) for the city of Natal is the mixed type (horizontal and vertical) and that the vertical shade elements are more efficient in the early mornings and late afternoon. The horizontal shade elements are used more effective at midday. We intend to present the results of this study to the architects in the region in order to show them the correct ways of using the shade elements according to the possible orientation on the facade, as a supporting tool at the time of designing a project as well as a subsidy for further discussions on the elaboration of the new urban standards for the city of Natal/RN
Resumo:
A housing unit was built to study the thermal performance, and of material using a composite made of gypsum and EPS ground. We used two techniques of construction, using blocks, and filling on the spot. Two compositions of the composite were studied. The blocks were fixed using conventional mortar. In the technical of filling on the spot were used PET bottles up inside the walls to provide mechanical and thermal resistance. Compression tests were realized according to the ABNT standard of sealing bricks. It is going to be shown an analysis of the thermal comfort through the use of thermocouples placed on the walls of the building, internally and externally. The manufacturing viability of houses, using recyclable materials, through the use of composite materials proposed will be demonstrated. The constructive aspects showing the advantages and disadvantages of the technique used also will be broached. The block used presents structural functions and thermal insulating, is low cost and represents an alternative to the use of EPS and PET bottles which are materials that end up occupying much space in the landfills, giving than an ecologically correct use. The results of thermal analysis shows the thermal comfort provided by the composite by the obtainment of a difference between the internal and external surfaces of the walls more exposed to the sun around 7º C. The average temperature of the air inside the building, around 28.0 º C was below the zone of thermal comfort recommended for countries with hot weather
Resumo:
We built an experimental house on an UFRN´s land using blocks made by a composite consisting of cement, plaster, EPS, crushed rubber and sand. Several blocks were made from various compositions and we made preliminary tests of mechanical and thermal resistance, choosing the most appropriate proportion. PET bottles were used inside the block to provide thermal resistance. In this work, a second function was given to the bottles: to serve as a docking between the blocks, because the ends of the cylinders came out of each block on top as well as at the bottom, with the bottom cut, allowing to fit of the extremities of the upper cylinder of a block in the lower holes of the other one, which were formed by the cutting already mentioned. Minimum compression tests were performed according to ABNT standards for walls closing blocks (fence). With that house built, we did studies of thermal performance in order to ascertain conditions of comfort, checking external and internal temperatures in the walls and in the ambient, among other variables, such as wind speed and relative humidity. The resulting blocks provided adequate thermal insulation to the environment, where the walls presented differences up to 11.7 ºC between the outer and inner faces, getting the maximum temperature inside the house around 31 °C, within the so-called thermal comfort zone for warm climates. At the end of the experiments it was evident the effectiveness of that construction in order to provide thermal comfort in the internal environment of the house, as well as we could confirm the viability of building houses from recyclable materials, reducing the constructive costs, becoming a suitable alternative for low- incoming families. Moreover, besides the low cost, the proposal represents an alternative use of various recyclable materials, therefore considered an ecological solution
Resumo:
Space Science was built using a composite made of plaster, EPS, shredded tires, cement and water. Studies were conducted to thermal and mechanical resistance. Inside the mold EPS plates were placed in order to obtain a higher thermal resistance on the wall constructed, as well as to give it an end environmentally friendly in view of both the tire and the EPS occupy a large space in landfills and year need to be degraded when released into the environment. Compression tests were performed according to ABNT blocks to seal, measurements of the temperature variation in the external and internal walls using a laser thermometer and check the temperature of the indoor environment using a thermocouple attached to a digital thermometer. The experiments demonstrated the heat provided by the composite values from the temperature difference between the internal and external surfaces on the walls, reaching levels of 12.4 ° C and room temperature in the interior space of the Science of 33.3 ° C, remaining within the zone thermal comfort for hot climate countries. It was also demonstrated the proper mechanical strength of such a composite for sealing walls. The proposed use of the composite can contribute to reducing the extreme housing shortage in our country, producing popular homes at low cost and with little time to work
Resumo:
This dissertation focuses on rock thermal conductivity and its correlations with petrographic, textural, and geochemical aspects, especially in granite rocks. It aims at demonstrating the relations of these variables in an attempt to enlighten the behavior of thermal effect on rocks. Results can be useful for several applications, such as understanding and conferring regional thermal flow results, predicting the behavior of thermal effect on rocks based upon macroscopic evaluation (texture and mineralogy), in the building construction field in order to provide more precise information on data refinement on thermal properties emphasizing a rocky material thermal conductivity, and especially in the dimension stone industry in order to open a discussion on the use of these variables as a new technological parameter directly related to thermal comfort. Thermal conductivity data were obtained by using Anter Corporation s QuicklineTM -30 a thermal property measuring equipment. Measurements were conducted at temperatures ranging between 25 to 38 OC in samples with 2cm in length and an area of at least 6cm of diameter. As to petrography data, results demonstrated good correlations with quartz and mafics. Linear correlation between mineralogy and thermal conductivity revealed a positive relation of a quartz percentage increase in relation to a thermal conductivity increase and its decrease with mafic minerals increase. As to feldspates (K-feldspate and plagioclase) they show dispersion. Quartz relation gets more evident when compared to sample sets with >20% and <20%. Sets with more than 20% quartz (sienogranites, monzogranites, granodiorites, etc.), exhibit to a great extent conductivity values which vary from 2,5 W/mK and the set with less than 20% (sienites, monzonites, gabbros, diorites, etc.) have an average thermal conductivity below 2,5 W/mK. As to textures it has been verified that rocks considered thick/porphyry demonstrated in general better correlations when compared to rocks considered thin/medium. In the case of quartz, thick rocks/porphyry showed greater correlation factors when compared to the thin/medium ones. As to feldspates (K-feldspate and plagioclase) again there was dispersion. As to mafics, both thick/porphyry and thin/medium showed negative correlations with correlation factor smaller than those obtained in relation to the quartz. As to rocks related to the Streckeisen s QAP diagram (1976), they tend to fall from alcali-feldspates granites to tonalites, and from sienites to gabbros, diorites, etc. Thermal conductivity data correlation with geochemistry confirmed to a great extent mineralogy results. It has been seen that correlation is linear if there is any. Such behavior could be seen especially with the SiO2. In this case similar correlation can be observed with the quartz, that is, thermal conductivity increases as SiO2 is incremented. Another aspect observed is that basic to intermediate rocks presented values always below 2,5 W/mK, a similar behavior to that observed in rocks with quartz <20%. Acid rocks presented values above 2,5 W/mK, a similar behavior to that observed in rocks with quartz >20% (granites). For all the other cases, correlation factors are always low and present opposite behavior to Fe2O3, CaO, MgO, and TiO2. As to Al2O3, K2O, and Na2O results are not conclusive and are statistically disperse. Thermal property knowledge especially thermal conductivity and its application in the building construction field appeared to be very satisfactory for it involves both technological and thermal comfort aspects, which favored in all cases fast, cheap, and precise results. The relation between thermal conductivity and linear thermal dilatation have also shown satisfactory results especially when it comes to the quartz role as a common, determining phase between the two variables. Thermal conductivity studies together with rocky material density can function as an additional tool for choosing materials when considering structural calculation aspects and thermal comfort, for in the dimension stone case there is a small density variation in relation to a thermal conductivity considerable variation
Resumo:
The Portalegre shear zone (ZCPa), which is located in the Rio Grande do Norte and Paraíba states (Northeastern Brazil), is na important right-lateral, northeast-trending lineament formed during the Brazilian Orogenic Cicle). The ZCPa experienced na important brittle reactivation from the Mesozoic until the present. This reactivation led to the formation of the Gangorra, Pau dos Ferros, Coronel João Pessoa, Icozinho and Rio do Peixe basins. The reactivation northern parto f the ZCPa that marks the boundary of the Potiguar Basin is denominated Carnaubais Fault. Several fracture patterns were mapped along the ZCPa. Samples were collected in Neoproterozoic granite outcrops, along the ZCPa. These samples yielded AFT ages from 86±13 to 376±57 Ma, and the mean track length from 10.9±0.8 to 12.9±1.5 mm. Samples from the East block yielded mean ages of 103 Ma, mean track lengtn 12,1mm, and mean altitude 250m, whereas samples from West block yielded mean ages of 150 Ma, which reach 345 Ma and 220 Ma in the Pau dos Ferros and Coronel João Pessoa basins, respectively. Thermal history models were sorted out for each crustal block. Samples from West block recorded a thermal history from Carboniferous Period until the Permiano, when the block experienced gradual uplift until the Cretaceous, when it underwent downfaulting and heating until the Tertiary, and it eventually experienced a rapid uplift movement until recent times. Samples from the East block presented the same cooling and heating events, but at they occurred different times. The East block thermal record started ~140 Ma, when this block experienced cooling until ~75 Ma. Both blocks show a denundacion/erosional history more similar in the Tertiary. The AFT data indicate an important tectonic event ~140 Ma, when the West block experienced downfaulting and the East block experienced uplift. This tectonic process led to the generation of several sedimentary basins in the region, including the Potiguar basin. This tectonic event is also interpreted as a rift process caused by an E-W-trending extension. It the Tertiary, some heating events can be tentatively attributed to the macau volcanic event
Resumo:
This work describes the design process of a small recreational gated community in Pium, Nísia Floresta/RN, from concept to final design stages, with emphasis on low environmental impact, thermal comfort and the spatial quality of housing. The process consisted in a review of the literature and relevant standards, studies of design references and architectural programming. The project development was initially focused on the project’s feasibility, with the definition of the number of units, implantation, size and location of the dwellings and the common areas of the development. Two types of houses (four low rise and five duplex units) have been proposed in order to attend the premises of architectural programming. The conception of the architectural design began with the rooms’ zoning according to the lots. This resulted in the pre-selection of three alternatives that were evaluated in terms of spatial quality and environmental performance. The development of sketches focused on the envelope consistent with the bioclimatic guidelines and on the language of the compatible proposal with the lowest possible environmental impact of the building system, which resulted in the selection of the eucalyptus wood type. During the working drawings, the Quality Technical Regulation for the Level of Energy Efficiency Residential Buildings (RTQ -R) was adopted for the evaluation of the envelope, which resulted in "B" level of efficiency for the first case. After minor adjustments, mainly in frames, the efficiency level rose to "A", demonstrating that early project decisions contributed to the envelope energy performance. Besides the design of the two types of units, the final proposal of the gated community includes the design of the equipment for the common areas (entrance, multipurpose room and support and service sector), and the descriptive texts explaining the project and construction’s details.
Resumo:
In the design of a building process must consider climatic variations in the region, the external conditions and the use of available resources in nature, like the sun, vegetation, rain and winds, to provide a built environment with comfort and environment reduced energy expenditure. However, increasing urbanization, often with an occupancy of disordered ground comes disregarding this knowledge and disregarding local characteristics, drastically reducing the green areas. This disordered occupation associated with the reduction of green spaces, is modifying aspects of climate and thus, damaging the thermal comfort of users. Given this situation was born the question: What projetuais strategies can bring better thermal conditions to an educational building located in a region of hot and humid weather? Thus, faced with two important issues , education and environmental comfort , the research is justified by the fact that there is a large national demand for expansions and renovations in its public schools , but not in most areas provides students with quality for good learning development. This paper aims to draw up a project for establishment of Primary Education with the application of the concepts of bioclimatic, highlighting the use of vegetation as a regulatory element of the climate. Initially we carried out a literature search; we analyzed architectural solutions and set up the site. The next phases, called understanding, were raised with the laws, rules and environmental restrictions. Subsequently, the program needs and the development of architectural design was defined. The conclusion of this paper presents the definition of criteria and solutions for the use of vegetation to design of bioclimatic architecture in hot and humid climates and contributes a catalog of plant species for schools in the metropolitan region of Natal, RN.
Resumo:
The demand for environmental comfort in construction systems within the insulation and thermal comfort, plus the advent of new laws regulating the minimum requirements of comfort, disposal of solid industrial waste, construction waste, the requirements of consumers by adopting construction methods "cleaner", encouraged the development of this work. Aims technologically characterize the composite proposed in three types of samples (10%, 30% and 50% of thermoset plastic industrial waste) and raw materials: gypsum waste, cement and plastic thermosetting industrial waste in order to produce the composite with properties of thermal insulation: conductivity, thermal diffusivity, specific heat and resistivity. The physical, structural and morphological properties of the raw materials were investigated by thermogravimetry analysis (TG / DSC), X-ray diffraction (DRX), X-ray fluorescence (FXR) and scanning electron microscopy (MEV). Obtaining mechanical properties through the compression strength test. The analysis results indicate characteristics suitable for cement matrix composite production with the addition of thermosetting plastic industrial waste and gypsum waste, with potential application of these materials in composites with properties of thermal insulation. Finally, assessing what proportion showed up with better performance. Considering the analysis and testing carried out.
Resumo:
The demand for environmental comfort in construction systems within the insulation and thermal comfort, plus the advent of new laws regulating the minimum requirements of comfort, disposal of solid industrial waste, construction waste, the requirements of consumers by adopting construction methods "cleaner", encouraged the development of this work. Aims technologically characterize the composite proposed in three types of samples (10%, 30% and 50% of thermoset plastic industrial waste) and raw materials: gypsum waste, cement and plastic thermosetting industrial waste in order to produce the composite with properties of thermal insulation: conductivity, thermal diffusivity, specific heat and resistivity. The physical, structural and morphological properties of the raw materials were investigated by thermogravimetry analysis (TG / DSC), X-ray diffraction (DRX), X-ray fluorescence (FXR) and scanning electron microscopy (MEV). Obtaining mechanical properties through the compression strength test. The analysis results indicate characteristics suitable for cement matrix composite production with the addition of thermosetting plastic industrial waste and gypsum waste, with potential application of these materials in composites with properties of thermal insulation. Finally, assessing what proportion showed up with better performance. Considering the analysis and testing carried out.
Resumo:
Natural ventilation is an efficient bioclimatic strategy, one that provides thermal comfort, healthful and cooling to the edification. However, the disregard for quality environment, the uncertainties involved in the phenomenon and the popularization of artificial climate systems are held as an excuse for those who neglect the benefits of passive cooling. The unfamiliarity with the concept may be lessened if ventilation is observed in every step of the project, especially in the initial phase in which decisions bear a great impact in the construction process. The tools available in order to quantify the impact of projected decisions consist basically of the renovation rate calculations or computer simulations of fluids, commonly dubbed CFD, which stands for Computational Fluid Dynamics , both somewhat apart from the project s execution and unable to adapt for use in parametric studies. Thus, we chose to verify, through computer simulation, the representativeness of the results with a method of simplified air reconditioning rate calculation, as well as making it more compatible with the questions relevant to the first phases of the project s process. The case object consists of a model resulting from the recommendations of the Código de Obras de Natal/ RN, customized according to the NBR 15220. The study has shown the complexity in aggregating a CFD tool to the process and the need for a method capable of generating data at the compatible rate to the flow of ideas and are discarded during the project s development. At the end of our study, we discuss the necessary concessions for the realization of simulations, the applicability and the limitations of both the tools used and the method adopted, as well as the representativeness of the results obtained