59 resultados para Ventilação pulmonar
Resumo:
The clinical importance of evaluating the respiratory muscles with a variety of tests has been proposed by several studies, once that the combination of several tests would allow a better diagnosis and therefore, a better clinical follow of disorders of the respiratory muscles. This study aimed to evaluate the feasibility of adapting a national electronic manovacuometer to measure the nasal inspiratory pressure (study 1) and analyze the level of load intensity of maximum voluntary ventilation, as well as the variables that may influence this maneuver in healthy subjects (study 2). We studied 20 healthy subjects by a random evaluation of two measures of SNIP in different equipments: a national and an imported. In study 2 it was analyzed the intensity of the load of MVV test, change in pressure developed during the maneuver, the possible differences between genders, and the correlations between the flow developed in the test and the result of MVV. In study 1 it was found the average for both measures of nasal inspiratory pressures: 125 ± 42.4 cmH2O for the imported equipment and 131.7 ± 28.7 cmH2O for the national one. Pearson analysis showed a significant correlation between the average, with a coefficient r = 0.63. The average values showed no significant differences evaluated by paired t test (p> 0.05). In the Bland-Altman analysis it was found a BIAS = 7 cmH2O, SD 32.9 and a confidence interval of - 57.5 cmH2O up to 71.5 cmH2O. In the second study it was found significant differences between the genders in the air volume moved, being higher in males 150.9 ± 13.1 l / min vs 118.5 ± 15.7 L / min for (p = 0.0002, 95% CI 44.85 to 20:05). Regarding the inspiratory and expiratory loading, they were significantly higher in men than in women, peak inspiratory pressure (34.7 ± 5.3 cmH2O vs 19.5 ± 4.2 cmH2O, 95% CI - 18.0 to -12.3, p <0.0001), peak expiratory (33.8 vs. 23.1 ± 5.9 cmH2O ± 5.4 cmH2O, 95% CI -17.1 to - 4.6, p <0.0001), and the delta pressure (59.7 ± 10 cmH2O vs 36.8 ± 8.3 cmH2O, 95% CI 14.5 to 31.2, p <0.0002). The Pearson correlation showed that the flow generated by the maneuver is strongly correlated with the delta-expiratory pressure / inspiratory (r2= 0.83,R = 0.91, 95%IC 0.72 a 0.97 e p< 0.0001).Through these results we suggest that the national electronic manovacuometer is feasible and safe to perform the sniff test in healthy subjects. For the MVV, there are differences between the genders in the intensity of pressure developed during the maneuver. We found a load intensity considered low during the MVV, and found a strong correlation between the flow generated in the test and the delta pressure expiratory / inspiratory
Resumo:
Introduction: The leukemias are the most common malignancy in children and adolescents. With the improvement in outcomes, there is a need to consider the morbidity to generate the protocols used in children under treatment. Aim: To evaluate pulmonary function in children with acute leukemia. Method: This study is an observational cross sectional. We evaluated 34 children distributed in groups A and B. Group A comprised 17 children with acute leukemia in the maintenance phase of chemotherapy treatment and group B with 17 healthy students from the public in the city of Natal / RN, matched for gender, age and height. The thoracic mobility was evaluated by thoracic expansion in the axillary and xiphoid levels. Spirometry was measured using a spirometer Microloop Viasys ® following the rules of the ATS and ERS. Maximal respiratory pressures were measured with digital manometer MVD300 (Globalmed ®). The maximal inspiratory pressure (MIP) and maximal expiratory pressure (MEP) were measured from residual volume and total lung capacity, respectively. The data were analyzed using the SPSS 17.0 software assigning the significance level of 5%. Descriptive analysis was expressed as mean and standard deviation. T'student test was used to compare unpaired values found in group A with group B values, as well as with the reference values used. To compare the respiratory coefficients in the axillary level with the xiphoid in each group, we used paired testing t student. Results: Group A was significantly decreased thoracic mobility and MIP compared to group B, and MIP compared to baseline. There was no significant difference between spirometric data from both groups and the values of group A with the reference values Mallozi (1995). There was no significant difference between the MIP and MEP values and lower limits of reference proposed by Borja (2011). Conclusion: Children with acute leukemia, myeloid or lymphoid, during maintenance phase of chemotherapy treatment have reduced thoracic mobility and MIP. However, to date, completion of clinical treatment, the spirometric variables and the strength of the expiratory muscles appear to remain preserved in children between five and ten years
Resumo:
Pulmonary Rehabilitation, especially due to aerobic exercise, positive impact in reducing morbidity/mortality of patients with COPD, however the economic impact with costs of implementing simple programs of aerobic exercise are scarce. This is a blind randomized clinical trials, which aimed to evaluate the costs and benefits of a simple program of aerobic exercise in individuals with COPD, considering the financial costs of the Public Health System and its secondary endpoints. We evaluated lung function, the distance walked during six minutes of walking, the respiratory and peripheral muscle strength, quality of life related to health (QLRH), body composition and level of activity of daily living (ADL) before and after eight weeks of an aerobic exercise program consisting of educational guidance for both groups, control and intervention and supervised walks to the intervention group. The health costs generated in both groups were calculated following table Brazilian Public Health System. The sample consisted of forty patients, two being excluded in the initial phase of desaturation during the walk test six minutes. Were randomized into control and intervention group thirty-eight patients, three were excluded from the control group and one was excluded from the intervention group. At the end, thirty-four COPD comprised the sample, 16 in the control group and 18 in the intervention group (FEV1: 50.9 ± 14% pred and FEV1: 56 ± 0.5% pred, respectively). After for intervention, the intervention group showed improvement in meters walked, the sensation of dyspnea and fatigue at work, BODE index (p <0.01) in QLRH, ADL level (p <0.001) as well as increased strength lower limbs (p <0.05). The final cost of the program for the intervention group was R $ 148.75, including: assessments, hiking supervised by a physiotherapist and reassessments. No patient had exacerbation of IG, while 2 patients in the CG exacerbated, generating an average individual cost of R $ 689.15. The aerobic exercises in the form of walking showed significant clinical benefits and economic feasibility of its implementation, due to low cost and easy accessibility for patients, allowing them to add their daily practice of aerobic exercises
Resumo:
Introdução: A obesidade infantil apresenta incidência crescente e as possíveis comorbidades, como alteração da função respiratória, estão cada vez mais presente nessa faixa etária. O tecido adiposo impõe carga ao sistema respiratório o que leva a um padrão restritivo. Essa condição sofre alterações com as mudanças posturais, onde a gravidade influencia o padrão respiratório de acordo com o posicionamento adotado. Objetivo: Avaliar a distribuição dos volumes total e regional e o movimento tóracoabdominal de crianças e adolescentes que estão acima do peso nas posturas supino e sentado. Métodos: Cinqüenta e duas crianças/adolescentes (8-12 anos) divididas em três grupos: Grupo Obeso (GO=22); Grupo Sobrepeso (GSP=9); Grupo Controle (GC=21) foram avaliadas quanto às medidas antropométricas, teste de função pulmonar, exame das pressões respiratórias máxima e a pletismografia optoeletrônica em duas posturas, supino e sentado, durante a respiração tranquila. Resultados: As crianças que estão obesas apresentaram maiores valores em relação ao GSP e GC das seguintes variáveis espirométricas: volume expiratório forçado no primeiro segundo (VEF1) (p<0.05) e capacidade vital forçada (CVF) (p<0.01). No exame de manovacuometria o GO apresentou um aumento na pressão inspiratória máxima (PImáx) (p<0.01) em comparação com os outros grupos. Quanto à distribuição do volume corrente, o GO possui uma maior contribuição do compartimento abdominal (AB) na postura supina (p<0.05) em relação ao GC e GSP, enquanto que na postura sentada os grupos não diferiram em relação à distribuição dos volumes. O GO apresentou maior assincronia na postura supina (p<0.05) e maior velocidade de encurtamento (p<0.05) em relação os outros grupos. Conclusão: A obesidade em crianças/adolescentes não provoca prejuízos na função pulmonar, incrementa a força muscular inspiratória, aumenta a participação do compartimento AB e a assincronia no MTA na postura em supino, conclui-se que a postura supina associada à obesidade provoca aumento da sobrecarga do diafragma, desfavorecendo o desempenho do sistema respiratório.
Resumo:
This work analyses a study on natural ventilation and its relation to the urban legislation versus the building types in an urban fraction of coastal area of Praia do Meio in the city of Natal/RN, approaching the type or types of land use most appropriate to this limited urban fraction. The objective of this study is to analyse the effects of the present legislation as well as the types of buildings in this area on the natural ventilation. This urban fraction was selected because it is one of the sites from where the wind flows into the city of Natal. This research is based on the hypothesis stating that the reduction on the porosity of the urban soil (decrease in the set back/boundary clearance), and an increase in the form (height of the buildings) rise the level of the ventilation gradient, consequently causing a reduction on the wind speed at the lowest part of the buildings. Three-dimensional computational models were used to produce the modes of occupation allowed in the urban fraction within the area under study. A Computational Fluid Dynamics (CFD) software was also used to analyse the modes of land occupation. Following simulation, a statistical assessment was carried out for validation of the hypothesis. It was concluded that the reduction in the soil porosity as a consequence of the rates that defined the minimum boundary clearance between the building and the boundary of the plot (and consequently the set back), as well as the increase in the building form (height of the buildings) caused a reduction in the wind speed, thus creating heat islands
Resumo:
Natural ventilation is an efficient bioclimatic strategy, one that provides thermal comfort, healthful and cooling to the edification. However, the disregard for quality environment, the uncertainties involved in the phenomenon and the popularization of artificial climate systems are held as an excuse for those who neglect the benefits of passive cooling. The unfamiliarity with the concept may be lessened if ventilation is observed in every step of the project, especially in the initial phase in which decisions bear a great impact in the construction process. The tools available in order to quantify the impact of projected decisions consist basically of the renovation rate calculations or computer simulations of fluids, commonly dubbed CFD, which stands for Computational Fluid Dynamics , both somewhat apart from the project s execution and unable to adapt for use in parametric studies. Thus, we chose to verify, through computer simulation, the representativeness of the results with a method of simplified air reconditioning rate calculation, as well as making it more compatible with the questions relevant to the first phases of the project s process. The case object consists of a model resulting from the recommendations of the Código de Obras de Natal/ RN, customized according to the NBR 15220. The study has shown the complexity in aggregating a CFD tool to the process and the need for a method capable of generating data at the compatible rate to the flow of ideas and are discarded during the project s development. At the end of our study, we discuss the necessary concessions for the realization of simulations, the applicability and the limitations of both the tools used and the method adopted, as well as the representativeness of the results obtained
Resumo:
The building envelope is the principal mean of interaction between indoors and environment, with direct influence on thermal and energy performance of the building. By intervening in the envelope, with the proposal of specific architectural elements, it is possible to promote the use of passive strategies of conditioning, such as natural ventilation. The cross ventilation is recommended by the NBR 15220-3 as the bioclimatic main strategy for the hot and humid climate of Natal/RN, offering among other benefits, the thermal comfort of occupants. The analysis tools of natural ventilation, on the other hand, cover a variety of techniques, from the simplified calculation methods to computer fluid dynamics, whose limitations are discussed in several papers, but without detailing the problems encountered. In this sense, the present study aims to evaluate the potential of wind catchers, envelope elements used to increase natural ventilation in the building, through CFD simplified simulation. Moreover, it seeks to quantify the limitations encountered during the analysis. For this, the procedure adopted to evaluate the elements implementation and efficiency was the CFD simulation, abbreviation for Computer Fluid Dynamics, with the software DesignBuilder CFD. It was defined a base case, where wind catchers were added with various settings, to compare them with each other and appreciate the differences in flows and air speeds encountered. Initially there has been done sensitivity tests for familiarization with the software and observe simulation patterns, mapping the settings used and simulation time for each case simulated. The results show the limitations encountered during the simulation process, as well as an overview of the efficiency and potential of wind catchers, with the increase of ventilation with the use of catchers, differences in air flow patterns and significant increase in air speeds indoors, besides changes found due to different element geometries. It is considered that the software used can help designers during preliminary analysis in the early stages of design
Resumo:
The present work studies the natural ventilation and its relationship with the urban standards, which establishes the form of occupation and use of the land in our cities. The method simulates the application of the urban standards of the City Master Plan over the last three years. The simulation takes place in the District of Petrópolis, in the city of Natal , Brazil and analyses the effects of the standards of natural ventilation. The formulated hypothesis states that the reductions in the urban spaces between buildings rises up the vertical profile of ventilation, reducing, therefore, the velocity of the wind at the lower levels of the buildings. To develop the study, occupation models were built, using computerized, three-dimensional models. These occupation models were analyzed using the CFD (Computational Fluid Dynamics) code. The conclusion is that the more we reduce the urban space between buildings, the more we reduce the wind speed in constructed areas, increasing, therefore, the possibility to generate heat islands
Resumo:
Seeds from legumes including the Glycine max are known to be a rich source of protease inhibitors. The soybean Kunitz trypsin inhibitor (SKTI) has been well characterised and has been found to exhibit many biological activities. However its effects on inflammatory diseases have not been studied to date. In this study, SKTI was purified from a commercial soy fraction, enriched with this inhibitor, using anion exchange chromatography Resource Q column. The purified protein was able to inhibit human neutrophil elastase (HNE) and bovine trypsin. . Purified SKTI inhibited HNE with an IC50 value of 8 µg (0.3 nM). At this concentration SKTI showed neither cytotoxic nor haemolytic effects on human blood cell populations. SKTI showed no deleterious effects on organs, blood cells or the hepatic enzymes alanine amine transferase (ALT) and aspartate amino transferase (AST) in mice model of acute systemic toxicity. Human neutrophils incubated with SKTI released less HNE than control neutrophils when stimulated with PAF or fMLP (83.1% and 70% respectively). These results showed that SKTI affected both pathways of elastase release by PAF and fMLP stimuli, suggesting that SKTI is an antagonist of PAF/fMLP receptors. In an in vivo mouse model of acute lung injury, induced by LPS from E. coli, SKTI significantly suppressed the inflammatory effects caused by elastase in a dose dependent manner. Histological sections stained by hematoxylin/eosin confirmed this reduction in inflammation process. These results showed that SKTI could be used as a potential pharmacological agent for the therapy of many inflammatory diseases
Resumo:
PEDRINI, Aldomar; SZOKOLAY, Steven. Recomendações para o desenvolvimento de uma ferramenta de suporte às primeiras decisões projetuais visando ao desempenho energético de edificações de escritório em clima quente. Ambiente Construído, Porto Alegre, v. 5, n. 1, p.39-54, jan./mar. 2005. Trimestral. Disponível em:
Resumo:
Objetivou-se avaliar os aspectos sociais e de saúde e a percepção diante do diagnóstico de indivíduos com a coinfecção HIV/tuberculose. Estudo descritivo, com abordagem quantiqualitativa, realizado em hospital de referência em Fortaleza, Ceará, de janeiro a abril de 2009, utilizando-se entrevista semiestruturada em ambiente privativo. Os dados foram analisados de modo descritivo e por análise de conteúdo. Participaram 16 pacientes com coinfecção HIV/tuberculose, 56,25% do sexo masculino, com faixa etária predominante entre 31 a 39 anos (43,75%), com pouca escolaridade e renda familiar mensal de aproximadamente um salário mínimo. A forma predominante da apresentação da tuberculose foi a pulmonar (62,50%). A percepção sobre a descoberta da coinfecção foi demonstrada por duas categorias: Medo e angústia face ao diagnóstico e Mudanças nos hábitos de saúde e no estilo de vida. Urge, diante dos achados, a promoção do bem-estar psicológico e físico desses pacientes, por meio de ações políticas e de saúde
Resumo:
Investigar a qualidade de vida de pacientes com coinfecção HIV/ tuberculose e apreender as mudanças impostas para viver simultaneamente com estas doenças transmissíveis. Métodos: Pesquisa com abordagem qualiquantitativa, realizada em ambulatório especializado em Fortaleza, Brasil, entre 2009 e 2010, com 34 coinfectados. Para coleta de dados foi utilizada uma escala de qualidade de vida, denominada HAT-QoL que possui 42 itens e questões abertas para possibilitar perceber as mudanças em face das doenças. Resultados: A maioria dos participantes tinha tuberculose na forma pulmonar, eram homens, com pouca escolaridade. A qualidade de vida mostrou-se prejudicada nos domínios relacionados às questões econômicas, sexuais e de sigilo. Ainda, foi evidenciado, que a coinfecção impõe mudanças no cotidiano que corroboram e ampliam o comprometimento da qualidade de vida. Conclusão: Vivenciar a coinfecção, mesmo com terapêutica adequada, produz alterações na vida dos infectados, cujas repercussões podem ser amenizadas com intervenções que promovam a saúde
Resumo:
This research has as its object study focus bioclimatic in architecture and its conection with projects decisions, on what regards to environmental comfort for single-family dwelling. From the analysis of five architectural projects inserted in Natal/RN, warm-moist weather, this research gather informations regarding architectural features guided by shape and space arrengement, which embody important elements for the project design development. Computer simulations assisted as foundation to verify the efficiency grade for these projects strategies from shading analysis. Related strategies for the demands of natural ventilation circulation and thermal mass for refrigeration were analysed as well. Results show that there is an hierarchizing of priorities for the decisions made when it comes to shape and space disposition variables, as well as the way these variables will consider the bioclimatic demands. The analysis, even, show that there is no single way to respond to specific bioclimatic demands, as it points out the value of examination of the projectual solutions throughtout the conception process, in order to achieve an efficient project performance for the envimonment comfort
Resumo:
This research presents a study investigating the correlation between the environmental-physycal charcateristics of cities and the formation of its micro-climates. The study was conducted in the central area of Fortaleza characterized as a stable and consolidated area, where the city originated and currently faces serious problems in its urban dynamics. The points of measurements were determined by the elaboration and analysis of topography maps, height of buildings, land use, type of surface coating and vegetation, following the methodology of Katzschner (1997). A zoning map was then determined, according to common morphological characteristics of the 12 measurement points, which were based on a set of Romero s (2001) bioclimatic criteria. Air measurements, temperature, humidity, intensity and direction of winds were made in transect form in two different circuits in the study area, with six points of data collection in each area, in three different times: 6:00 am, 1:00pm and 7:00pm, during two periods of the year: August 2008 and March 2009. The results verified the influence of different environmental-physical types in the behavior of the climatic variables that were collected. A verticalização tão condenada em algumas situações se bem equilibrada e controlada pode reduzir as temperaturas do ar através do sombreamento dos espaços urbanos e possibilidade de maior permeabilidade a ventilação natural. The highest average air temperature and lower humidity were recorded at the point I at all times. This situation may have been in result of the high density, poor vegetation and extended paving of the ground. According to the results, it s clear the positive influence vegetation has on easing air temperature. Another indicator observed that areas with a greater variation in building heights tend to present decreased average air temperature. High rise structure, planned in accordance to urban air quality parameters, can reduce air temperatures by the shading of urban spaces and the possibility of greater penetration of natural ventilation
Resumo:
This research covers the topic of social housing and its relation to thermal comfort, so applied to an architectural and urban intervention in land situated in central urban area of Macaíba/RN, Brazil. Reflecting on the role of design and use of alternative building materials in the search for better performance is one of its main goals. The hypothesis is that by changing design parameters and choice of materials, it is possible to achieve better thermal performance results. Thus, we performed computer simulations of thermal performance and natural ventilation using computational fluid dynamics or CFD (Computational Fluid Dynamics). The presentation of the thermal simulation followed the methodology proposed in the dissertation Negreiros (2010), which aims to find the percentage of the amount of hours of comfort obtained throughout the year, while data analysis was made of natural ventilation from images generated by the images extracted from the CFD. From model building designed, was fitted an analytical framework that results in a comparison between three different proposals for dwellings housing model, which is evaluated the question of the thermal performance of buildings, and also deals with the spatial variables design, construction materials and costs. It is concluded that the final report confirmed the general hypotheses set at the start of the study, it was possible to quantify the results and identify the importance of design and construction materials are equivalent, and that, if combined, lead to gains in thermal performance potential.