23 resultados para Transmissão vetorial
Resumo:
The use of middleware technology in various types of systems, in order to abstract low-level details related to the distribution of application logic, is increasingly common. Among several systems that can be benefited from using these components, we highlight the distributed systems, where it is necessary to allow communications between software components located on different physical machines. An important issue related to the communication between distributed components is the provision of mechanisms for managing the quality of service. This work presents a metamodel for modeling middlewares based on components in order to provide to an application the abstraction of a communication between components involved in a data stream, regardless their location. Another feature of the metamodel is the possibility of self-adaptation related to the communication mechanism, either by updating the values of its configuration parameters, or by its replacement by another mechanism, in case of the restrictions of quality of service specified are not being guaranteed. In this respect, it is planned the monitoring of the communication state (application of techniques like feedback control loop), analyzing performance metrics related. The paradigm of Model Driven Development was used to generate the implementation of a middleware that will serve as proof of concept of the metamodel, and the configuration and reconfiguration policies related to the dynamic adaptation processes. In this sense was defined the metamodel associated to the process of a communication configuration. The MDD application also corresponds to the definition of the following transformations: the architectural model of the middleware in Java code, and the configuration model to XML
Resumo:
The scarcity of occurrence records of culicid species, transmitting insects of etiologic agents for arboviruses, protozoan diseases and philarioses, and lack of information about their interactions with the forest environment make the Caatinga one of the most unknown biomes in Brazil. The aim of this study was to identify culicid species in a conservation unit located in a preserved area of the Caatinga and the possible associations with local abiotic factors, as well as characterize the natural and artificial ecotopes present in the Caatinga of Rio Grande do Norte state. The Ecological Station of Serido (ESEC-Seridó) is a Caatinga Conservation Unit located in a rural area of Rio Grande do Norte. The hot and dry climate of the Caatinga, along with a short rainy season, favor the adaptation and resistance of plants, resulting in completely distinct landscapes over the course of the year. The study took place over the course of one year, with monthly collections between 10h-12h, 14h-16h and 18h-20h. Adult mosquitoes were collected in a forest area using a manual suction trap with human bait as attractant at the three times and a Shannon trap for night collections. During the rainy season ovitraps were randomly distributed at different sites. The different capture sites were observed and photographed. Immature and adult insects captured were taken to the laboratory for identification. Of the 5081 insects collected in human-bait and Shannon traps, 75% were Mansonia wilsoni. In addition, Aedeomyia, Aedes, Anopheles, Coquillettidia, Culex, Haemagogus, Mansonia and Psorophora were identified. Of the 92 Haemagogus eggs found, 71 were collected on the banks of a reservoir. Mosquito larvae were found and photographed in an artificial breeding site of a neighboring rural area. Humidity had the greatest influence on culicid density in the Caatinga. Rain was important in the appearance of Haemagogus, Anopheles, Aedes and Psorophora. Temperature had a negative influence on Anopheles triannulatus. The occurence of important vector species of diseases in a little known preserved area of the Caatinga as well as environmental and sociocultural questions are factors that favor the emergence of transmitting insects, making these areas potential subject to the resurgence of diseases
Resumo:
This work an algorithm for fault location is proposed. It contains the following functions: fault detection, fault classification and fault location. Mathematical Morphology is used to process currents obtained in the monitored terminals. Unlike Fourier and Wavelet transforms that are usually applied to fault location, the Mathematical Morphology is a non-linear operation that uses only basic operation (sum, subtraction, maximum and minimum). Thus, Mathematical Morphology is computationally very efficient. For detection and classification functions, the Morphological Wavelet was used. On fault location module the Multiresolution Morphological Gradient was used to detect the traveling waves and their polarities. Hence, recorded the arrival in the two first traveling waves incident at the measured terminal and knowing the velocity of propagation, pinpoint the fault location can be estimated. The algorithm was applied in a 440 kV power transmission system, simulated on ATP. Several fault conditions where studied and the following parameters were evaluated: fault location, fault type, fault resistance, fault inception angle, noise level and sampling rate. The results show that the application of Mathematical Morphology in faults location is very promising
Resumo:
In this dissertation, are presented two microstrip antennas and two arrays for applications in wireless communication systems multiband. Initially, we studied an antenna and a linear array consisting of two elements identical to the patch antenna isolated. The shape of the patch used in both structures is based on fractal geometry and has multiband behavior. Next a new antenna is analyzed and a new array such as initial structure, but with the truncated ground plane, in order to obtain better bandwidths and return loss. For feeding the structures, we used microstrip transmission line. In the design of planar structures, was used HFSS software for the simulation. Next were built and measures electromagnetic parameters such as input impedance and return loss, using vector network analyzer in the telecommunications laboratory of Federal University of Rio Grande do Norte. The experimental results were compared with the simulated and showed improved return loss for the first array and also appeared a fourth band and increased directivity compared with the isolated antenna. The first two benefits are not commonly found in the literature. For structures with a truncated ground planes, the technique improved impedance matching, bandwidth and return loss when compared to the initial structure with filled ground planes. Moreover, these structures exhibited a better distribution of frequency, facilitating the adjustment of frequencies. Thus, it is expected that the planar structures presented in this study, particularly arrays may be suitable for specific applications in wireless communication systems when frequency multiband and wideband transmission signals are required.
Resumo:
This work deals with the specification and the implementation of a protocol for controlling communication between two programmable interface microcontrollers (PIC), using power line communication (PLC), making communication more secure and economically viable. The Protocol was implemented in C language, with reference to some protocols developed for automotive use. A circuit to test the communication between the PLC and the Protocol was also implemented.
Resumo:
The performance of algorithms for fault location i n transmission lines is directly related to the accuracy of its input data. Thus, fa ctors such as errors in the line parameters, failures in synchronization of oscillographic recor ds and errors in measurements of voltage and current can significantly influence the accurac y of algorithms that use bad data to indicate the fault location. This work presents a new method ology for fault location in transmission lines based on the theory of state estimation in or der to determine the location of faults more accurately by considering realistic systematic erro rs that may be present in measurements of voltage and current. The methodology was implemente d in two stages: pre-fault and post- fault. In the first step, assuming non-synchronized data, the synchronization angle and positive sequence line parameters are estimated, an d in the second, the fault distance is estimated. Besides calculating the most likely faul t distance obtained from measurement errors, the variance associated with the distance f ound is also determined, using the errors theory. This is one of the main contributions of th is work, since, with the proposed algorithm, it is possible to determine a most likely zone of f ault incidence, with approximately 95,45% of confidence. Tests for evaluation and validation of the proposed algorithm were realized from actual records of faults and from simulations of fictitious transmission systems using ATP software. The obtained results are relevant to show that the proposed estimation approach works even adopting realistic variances, c ompatible with real equipments errors.
Resumo:
The classifier support vector machine is used in several problems in various areas of knowledge. Basically the method used in this classier is to end the hyperplane that maximizes the distance between the groups, to increase the generalization of the classifier. In this work, we treated some problems of binary classification of data obtained by electroencephalography (EEG) and electromyography (EMG) using Support Vector Machine with some complementary techniques, such as: Principal Component Analysis to identify the active regions of the brain, the periodogram method which is obtained by Fourier analysis to help discriminate between groups and Simple Moving Average to eliminate some of the existing noise in the data. It was developed two functions in the software R, for the realization of training tasks and classification. Also, it was proposed two weights systems and a summarized measure to help on deciding in classification of groups. The application of these techniques, weights and the summarized measure in the classier, showed quite satisfactory results, where the best results were an average rate of 95.31% to visual stimuli data, 100% of correct classification for epilepsy data and rates of 91.22% and 96.89% to object motion data for two subjects.
Resumo:
American visceral leishmaniasis is a zoonosis caused by Leishmania infantum and transmitted by the bite of the sand flies Lutzomia longipalpis.The main domestic reservoir is the dog, while foxes and opposums are the known wild reservoirs. However, identification of natural infections with L. infantum in rodents appears for need of investigating the participation of these rodents how source of infection of the parasite. In the present work the Leishmania infantum infection was investigated in rodents captured in Rio Grande do Norte, aiming at to offer subsidies to the understanding of the epidemic chains of LVA in the State. Thirteen Galea spixii were distributed in four groups, being G1 the group control with four animals and the others, G2, G3 and G4, with three animals each. Those animals were intraperitoneally inoculated with 107 promastigotas of L. infantum and accompanied for, respectively, 30, 90 and 180 days. Weekly the animals were monitored as for the corporal weight and rectal temperature. At the end of each stipulated period the animals were killed. Blood were used for determination of the parameters biochemical and haematological, PCR, ELISA, microscopic examination and cultivation in NNN medium. Liver, spleen and lymph node were used in Giemsa-stained impression and cultivation in NNN medium. Liver and spleen fragments were still used in PCR and histopathological, respectively. At the same time 79 rodents of the species Rattus rattus, Bolomys lasiurus, Oligoryzomys nigripis, Oryzomys subflavus and Trichomys apereoides were captured in the Municipal districts of Brejinho, Campo Grande, Coronel Ezequiel, Passa e Fica and Vázea for identification of natural infection with L. infantum. Evidence of infection was checked by direct examination of Giemsa-stained impression of liver, spleen and blood and culture of these tissues in NNN medium. Antibodies were researched by ELISA. They were not found differences among the weigh corporal final, rectal temperature and biochemical and haematological parameters of the Galea spixii controls and infected. The rectal temperature of the animals varied from 36OC to 40OC. For the first time values of the haematocrit (33,6% to 42,8%), hemoglobin (10,2 to 14,5g/dl), erythrocyts number (4,67x106 to 6,90x106/mm3), total leukocytes (0,9x103 to 9,2x103/mm3), platelets (49x103 to 509x103/mm3) total proteins (1,56 to 6,06 g/dl), albumin (1,34 to 3,05 g/dl) and globulins (0,20 to 3,01 g/dl) of the Galea spixii were determined. The lymphocytes were the most abundant leucocytes. Infection for L. infantum was diagnosed in two animals euthanasied 180 days after the infection. In one of the animals was also identified antibodies anti-Leishmania. The parasite was not found in none of the five other species of rodents captured. Galea spixii are resistant to the infection for L. infantum and they are not good models for the study for visceral leishmaniose, although they can act as infection sources. More studies are necessary to determine the paper of the rodents in the epidemic chain of transmission of the visceral leishmaniose in the State of Rio Grande do Norte