30 resultados para Thínk tank


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Flex-fuel vehicles are equipped with Otto Cycle internal combustion engines and have the capability of functioning with more than one type of fuel, mixed at the same tank and burned in the combustion chamber simultaneously. This sort of motorization is a world pattern due to the scarcity of petroleum, the trade of several types of fuels, technology advances and the restriction imposed to gas emissions to the atmosphere. In Brazil, the Flexfuel vehicles are a reality, specially the ones using fuel with 20 to 25% anhydrous alcohol mixed with gasoline and those that use natural gas or original liquid fuel (gasoline or hydrated ethanol). The Brazilian model Fiat Siena, the object of this present scientific investigation, is equipped with a unique electronic central capable of managing the liquid or gaseous fuels. The purpose of this research was to perform a comparative analysis in terms of performance (in terms of both potency and consumption) of a tetra-fuel vehicle - using a chassis dynamometer, operating with different fuels: common gasoline, premium gasoline, Podium gasoline, ethanol or natural gas. It became necessary to develop a bench of tests and trials procedures, as well as to know the functioning of the electronic management of the vehicle under analysis. The experiments were performed at the automotive laboratory in CTGAS-ER (Center of Gas Technologies and Renewable energies) at the light of Brazilian standard ABNT, NBR 7024: Light on-road vehicles - measurement of fuel consumption. The essay results on specific fuel consumption using common gasoline, premium gasoline and Podium gasoline have shown similar results, both for urban and road driving cycles

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Among the main challenges in the beer industrial production is the market supply at the lowest cost and high quality, in order to ensure the expectations of customers and. consumers The beer fermentation stage represents approximately 70% of the whole time necessary to its production, having a obligatoriness of strict process controls to avoid becoming bottleneck in beer production. This stage is responsible for the formation of a series of subproducts, which are responsible for the composition of aroma/bouquet existing in beer and some of these subproducts, if produced in larger quantities, they will confer unpleasant taste and odor to the final product. Among the subproducts formed during the fermentation stage, total vicinal diketones is the main component, since it is limiting for product transfusion to the subsequent steps, besides having a low perception threshold by the consumer and giving undesirable taste and odor. Due to the instability of main raw materials quality and also process controls during fermentation, the development of alternative forms of beer production without impacting on total fermentation time and final product quality is a great challenge to breweries. In this work, a prior acidification of the pasty yeast was carried out, utilizing for that phosphoric acid, food grade, reducing yeast pH of about 5.30 to 2.20 and altering its characteristic from flocculent to pulverulent during beer fermentation. An increase of six times was observed in amount of yeast cells in suspension in the second fermentation stage regarding to fermentations by yeast with no prior acidification. With alteration on two input variables, temperature curve and cell multiplication, which goal was to minimize the maximum values for diketones detected in the fermenter tank, a reduction was obtained from peak of formed diacetyl and consequently contributed to reduction in fermentation time and total process time. Several experiments were performed with those process changes in order to verify the influence on the total fermentation time and total vicinal diketones concentration at the end of fermentation. This experiment reached as the best production result a total fermentation time of 151 hours and total vicinal diketone concentration of 0.08 ppm. The mass of yeast in suspension in the second phase of fermentation increased from 2.45 x 106 to 16.38 x 106 cells/mL of yeast, which fact is key to a greater efficiency in reducing total vicinal diketones existing in the medium, confirming that the prior yeast acidification, as well as the control of temperature and yeast cell multiplication in fermentative process enhances the performance of diketones reduction and consequently reduce the total fermentation time with diketones concentration below the expected value (Max: 0.10 ppm)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The oil industry, experiencing a great economic and environmental impact, has increasingly invested in researches aiming a more satisfactory treatment of its largest effluent, i.e., produced water. These are mostly discarded at sea, without reuse and after a basic treatment. Such effluent contains a range of organic compounds with high toxicity and are difficult to remove, such as polycyclic aromatic hydrocarbons, salts, heavy metals, etc.. The main objective of this work was to study the solar distillation of produced water pre-treated to remove salts and other contaminants trough of a hybrid system with a pre-heater. This developed apparatus was called solar system, which consists of a solar heater and a conventional distillation solar still. The first device consisted of a water tank, a solar flat plate collector and a thermal reservoir. The solar distillator is of simple effect, with 1m2 of flat area and 20° of inclination. This dissertation was divided in five steps: measurements in the solar system, i.e. temperatures and distillate flow rate and weather data; modeling and simulation of the system; study of vapor-liquid equilibrium of the synthetic wastewater by the aqueous solution of p-xylene; physical and chemical analyses of samples of the feed, distillate and residue, as well as climatology pertinent variables of Natal-RN. The solar system was tested separately, with the supply water, aqueous NaCl and synthetic oil produced water. Temperature measurements were taken every minute of the thermal reservoir, water tank and distillator (liquid and vapor phases). Data of solar radiation and rainfall were obtained from INPE (National Institute for Space Research). The solar pre-heater demonstrated to be effective for the liquid systems tested. The reservoir fluid had an average temperature of 58°C, which enabled the feed to be pre-heated in the distillator. The temperature profile in the solar distillator showed a similar behavior to daily solar radiation, with temperatures near 70°C. The distillation had an average yield of 2.4 L /day, i.e., an efficiency of 27.2%. Mathematical modeling aided the identification of the most important variables and parameters in the solar system. The study of the vapor-liquid equilibrium from Total Organic Carbon (TOC) analysis indicated heteroazeotropia and the vapor phase resulted more concentrated in p-xylene. The physical-chemical analysis of pH, conductivity, Total Dissolved Solids (TDS), chlorides, cations (including heavy metals) and anions, the effluent distillate showed satisfactory results, which presents a potential for reuse. The climatological study indicates the region of Natal-RN as favorable to the operation of solar systems, but the use of auxiliary heating during periods of higher rainfall and cloud cover is also recommended

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In wastewater treatment, activated sludge systems have been a technology widely applied as secondary treatment. During this step, which has a strong biological aspect, it is necessary to introduce oxygen supply for the maintenance of metabolic activity of the bacteria through the aerators. Aeration devices are responsible for most of the energy consumption in this stage. In this background, the influence of three aeration intensities (atmospheric air flow 3.5, 7.0 and 10.5 L.min-1) and the concentration of dissolved oxygen (DO) on the dimension of activated sludge flocs as well as on the efficiency of organic matter removal were assessed using a traditional activated sludge system which was fed with synthetic domestic wastewater. Samples were taken weekly from the three units that make up the system feed, aeration and storage tank in order to verify the Chemical Oxygen Demand (COD). It was established the process efficiency through a comparison between the initial and final COD. Besides the parameters already mentioned, this monitoring work on activated sludge batch system was also observed by Mixed Liquor Suspend Solids (MLSS), Volatile Suspend Solids (VSS), pH and temperature measures. The results have showed a maximum removal efficiency around 75% in the first aeration sequence and approximately 85% for the second and third one. For the first aeration, the DO concentration remained higher than 3.0 mg.L-1 and a diameter range from 10 to 60 μm was observed. In the second e third sequence, the DO concentration remained higher than 4.0 mg.L-1 with a diameter range of 10 until 200 μm. Although the sequence 1 and 2 have presented similar performances for organic matter removal, the sequence 2 promoted a regular floc size distribution and with lower values of Sludge Volumetric Index (SVI) meaning a better flocculating ability. In addition, the results reaffirmed what the literature has reported: higher DO concentrations produce flocs with greater dimensions

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The disposal of sewage sludge is a growing problem face up to management of sanitary sevices. Otherwise, because its making process characteristic, the Ceramic Industry can tolerate the presence of this wastes as raw material. This study has as object to confirm the use of the sewage sluge in the Ceramic Industry like a sustentable alternative for its disposal. Futhermore, this study quests to evaluate the maximum proportion for incorporation of sludge wich result in technically and enviromentally suitable bricks. For found this proportion, the research consisted of (1) making of bricks in full scale, adde up 0%, 5%,10%, 15%, 20%, 25%,30%, 35% e 40% sludge, with size 220x105x45 mm, hand-molded by rammer and baked by industrial kiln; and (2) tecnical and enviromental evaluation of this bricks, according to Brazilian norms. The raw material uses were two distinct clays come from Goianinha/RN and sewage comes from a septic system tank and pumped into tank vehicle, of Natal/RN. The technical evaluation allowed to conclude the addiotion of the sludge brings about signifcant lost of mass and the water absorption grew up according to increase of sludge: every sludge-amended clay bricks absorved more water than control group. Thus, the compressive strength was signicantly decreased because the increase of sludge: bricks with 5% sludge added lost 45% of strength achieved at control group; the bricks made with 10 and 20% lost almost 70% of bigger strength. With up to 25% sludge added to the bricks, the streght decreased over 90%. Concerning heavy metal leaching, the two maximum proportion wich have tecnical approval, it means bricks sludge added with 15 and 20%, can say there is no risk of enviromental contamination using those bricks. This way, in this work context, it can to conclude the maximum proportion atends the technical and enviromental criterion is 20%

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In northeastern semiarid, seasonality on precipitation temporal distribution, high intensity storm events and inadequate management of native vegetation can promote soil erosion. Vegetation removal causes soil surface exposure, reduces soil water storage capacity and can be the source degradation processes. In this context, this approach aims to analyze water and soil erosion processes on a 250 m2 undisturbed experimental plot with native vegetation, slope 2.5% by using 2006 and 2007 monitoring data. The site was instrumented to monitor rainfall, overland flow runoff and erosion by using a 5 m³ tank downstream the plot. Soil erosion monitoring was made by transported sediment and organic matter collection after each event. Field infiltration experiments were made at 16 points randomly distributed within the plot area by using a constant head infiltrometer during drought and rainy seasons, respectively. Infiltration data revealed high spatial and temporal variability. It was observed that during the beginning of the rainy period, 77% of the events showed runoff coefficient less than 0.05. As the rainy season began, soil water increase produced annual species germination. High intensity storms resulted in runoff coefficients varying between 0.33 and 0.42. Once the annual species was established, it was observed that approximately 39% of the events produced no runoff, which reflects an increase on soil water retention capacity caused by the vegetation. A gradual runoff reduction during the rainy season emphasizes the effect of vegetative density increase. Soil erosion observed data allowed to fit an empirical relationship involving soil loss and precipitation height, which was used to analyze the plot installation impact on soil erosion. Observed soil loss in 2006 and 2007 was 230 Kg/ha and 54 Kg/ha, respectively

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In Natal still dominates the use of individual disposal systems for domestic sewage, once only 29% of the city has a sewarage system. Wastes that are accumulated in these individual treatment systems should be exhausted periodically, service provided by collector entrepreneurs. Some of these companies causing major damage to the environment. In Natal, only two companies have their own septage (RESTI) treatment system, which were designed with parameters from domestic sewage generating strain and inefficient systems. Therefore, the characterization becomes essential as a source of parameters for their design. Thus, this work presents the physical-chemical and microbiological characterization of waste pumped from individual sewage treatment systems. Samples collections were made weekly from 5 different trucks at the reception point on the treatment plant on the point of the preliminary treatment. From each truck it was taken 5 samples during the discharge in order to make a composite sample. Afterwards, samples were carried out to laboratory and analyses for determination of temperature, pH, conductivity, BOD, COD, nitrogen (ammonia e organic), alkalinity, oils, phosphorus, solids, faecal coliforms and helminth egg. The results were treated as a single database, and ranked according to its generating source (multi and single house, lodging, health, services and / or food), area of origin (metropolitan, south and north) and type of system (cesspits, septic tank and / or sink). Through these data it was possible to verify that the type of system adopted by most in Natal and the metropolitan region is cesspit, besides to confirm the difference between the septage of areas with a population have different social and economical characteristics. It was found that the septage have higher concentrations than domestic sewage, except for thermotolerant coliforms that showed concentrations of 1,38E+07. Among the parameters studied, is the median values identified for COD (3,549 mg / L), BOD (973mg / L) and total solids (3.557mg / L). The volatile fraction constitutes about 70% of the total solids of the septage. For helminths has been a median of 7 eggs/L. In general, the characteristics of the waste followed the variability found in the literature reviewed for all variables, showing high amplitudes

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Because of disability in public policy development in mind to attend issues of sanitation in the municipalities, companies known as "clean-blue" appeared proposing to solve a simple collection and management of wastewater produced in single or multifamily residences, commercial, hospitals, etc. In the case of an activity in which there are no worries about the fate of sewage, emerged some doubts about the degree of health and environmental safety in these companies. Traditionally, most of them makes the provision of waste depleted soil or wetland, open, usually located on the outskirts of cities (MENESES, 2001). In turn, the sludge from septic tanks exhausted, provided no technical criteria - in the soil, rivers and as an agricultural fertilizer put in risk the health of the population and environmental quality. This work was entered in the search network 5 of the Notice of the Research Program in Sanitation - PROSAB-5, aimed to study the theme 'Characterization and study of alternative ways of treating sludge from septic tanks in the city of Natal, RN', proposing to evaluate the performance of the use of stabilization ponds as a system to handle waste from septic tanks exhausted. A series of lakes studied belong to one of the largest clean-pit of Natal, consisting of two anaerobic ponds, one facultative and maturation, and a tank disinfection, the wastewater being released in the Potengi River. Samples were collected between the months of October 2007 to October 2008, at six points previously defined and judged as more appropriate to what is proposed study. The analysis results in field and laboratory showed the most significant removal of COD (88.93%), total suspended solids (94.87%), organic nitrogen (66.87%) and thermotolerant coliforms (99.88%). Some results have not reached the expected because the system under study had operating problems that have undermined the efficiency of the reactors

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Only 32% of the population of Natal is attended by sewage, while the remaining population use pits and septic tanks. The characterization of the contents of septic tanks and pits contributes to the performance of such system and may guide the decision on treatment of these contents. The main of this research is to characterize the contents of interior residential pits and septic tanks in the greater Natal, with the following specific goals: to develop and manufacture a sampler capable of collecting a representative sample of the entire column (the surface scum, the clarified liquid and sludge bottom); to compare the contents of the tanks with the pits; to compare the contents of the septage from vacuum trucks; to relate the composition content with socioeconomic characteristics of households; to compare the content in both chambers of the septic tanks in series; to assess the situation of the content before and six months after the cleanness; and ultimately propose a pilot scale plant for treatment of septage. Once the sampler was developed, samples were collected within 14 septic tanks and 10 pits in many districts of Natal. Medians of the 24 systems were obtained: temperature, pH, conductivity, oil and grease, total solids, total suspended solids and sediments of 28.0 °C, 6.95; 882 mS/cm, 75.2 mg/L; 10,169 mg/L, 6,509 mg/L and 175 mL/L respectively; 111.0 mgN/L for ammonia, 130.5 mgN/ L for organic nitrogen, 0.2 mgN/L for nitrite, 0.4 mg/L for nitrate; 8935 mgO2/L for COD, 29.2 mgP/L for total phosphorus, thermotolerant coliforms from 9.95 E +06 CFU/100mL helminth eggs and 9.2 eggs/L with a maximum concentration of 688 eggs/L and minimum of 0 eggs/L. Medians of organic nitrogen and TKN were significantly different between groups of tanks and pits. The systems with cleanness gap from 11 and 20 years presented the higher concentrations for most variables. The effluent from the toilets and bathrooms participate more effectively in contributing fractions of solids, alkalinity, nitrogen, COD, total phosphorus, thermotolerant coliforms and helminth eggs. The systems used by socioeconomics class with income from R$ 3,700.00 to R$ 7,600.00, presented higher concentrations for COD, nitrogen, solids and helminth eggs. The first of the two chambers had always presented higher concentrations over the second compartment. The analysis of variance for most variables, showed that the values of septic tanks, pits and septage from vacuum trucks belong to the same group. In the samples taken after cleanness, the median of pH and temperature increased, while alkalinity, COD, organic nitrogen, total phosphorus, ammonia and helminth eggs decreased. The oils and greases and thermotolerant coliforms had slightly varied due to the continuous release of sewage into the systems that maintained their steady state concentrations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although the good performance in organic matter and suspended solids removal, the anaerobic reactors are unable to remove ammonia nitrogen from sewage, which makes indispensable to include a step of post-treatment for removal of ammonia or nitrate as necessary. This paper presents the performance of a new variant technology, where the nitrification unit, preceded by anaerobic units, is a submerged aerated biological filter, without continuous sludge discharge in their daily operation. The oxygenation system is very simple and inexpensive, consisting of perforated hoses and compressors. The anaerobic reactors are a septic tank with two chambers followed (8.82 m³) and two parallel anaerobic filters (36 m³ each) filled with ceramic bricks and conics plastic parts. Both followed aerated filters were filled with cut corrugated conduit. The study evaluated the behavior of the system with constant domestic sewage flow (10 m³/d) and different aeration conditions, are these: stage 01, when applied air flow of 0.01 m³ air/min in both aerated filter; stage 02, remained in the initial air flow rate in the second aerated filter and increased at the first to 0.05 m³ air/min; at last, at last, in stage 03, the air flow rate of first aerated filter was 0.10 m³ air/min and on the second remained at 0.01 m³ air/min. The filter FA1 received load of 0.41 kg COD/m³.d, 0.37 kg COD/m³.d and 0.26 kg COD/m³.d on phases 01, 02 and 03, respectively. The FA2 received loads of 0.25 kg COD/m³.d, 0.18 kg COD/m³.d and 0.14 kg COD/m³.d on phases 01, 02 and 03, respectively. During stage 01, were found the following results: 98% removals of BODtotal and 92% of CODtotal, with effluent presenting 9 mg/L of BODtotal final average and 53 mg/L of CODtotal average; suspended solids removals of 93%, with a mean concentration of 10 mg/L in the final effluent; 47% reduction of ammonia of FA2 to FAN 's, presenting average of 28 mg NNH3/ L of ammonia in the effluent with; the dissolved oxygen levels always remained around 2.0 mg/L. During stage 02, were found removals of 97% and 95% to BODtotal and suspended solids, respectively, with average final concentrations of 8 and 7 mg/L, respectively; was removed 60% of ammonia, whose final concentration was 16.3 mg NNH3/ L, and nitrate was increased to a final average concentration of 16.55 mg N-NO3/L. Finally, the stage 03 provided 6 mg/L of DBOtotal (98% removal) and 23 mg/L of CODtotal (95% removal) of final effluent concentrations average. At this stage was identified the higher ammonia oxidation (86%), with final effluent showing average concentration of 6.1 mg N-NH3/L, reaching a minimum of 1.70 mg N-NH3/L. In some moments, during stage 03, there was a moderate denitrification process in the last aerated filter. The average turbidity in the effluent showed around 1.5 NTU, proving the good biomass physical stability. Therefore, the results demonstrate the submerged biological filters potential, filled with high void ratio material (98%), and aerated with hoses and compressor adoption, in the carbonaceous and nitrogenous matter oxidation, also generating an effluent with low concentration of solids

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stabilization pond is the most used sewage treatment system in the country, corresponding to approximately 90% of all systems. The systems evaluated were stabilization ponds system of sewage treatment in the city of Natal / RN. This research aimed to analyze the possible uses through physical-chemical and bacteriological of these final effluent ponds for urban uses depending on the characteristics after passage around the treatment system. The parameters used were chosen according to those established by Chernicharo et al. (2006), in order to characterize the effluent. The parameters evaluated were: DO, temperature, pH, conductivity, organic nitrogen, ammonia, NTK, total phosphorus, and series of solid fecal coliforms. Generally, the characteristics of the effluent followed variability found in the literature. The results showed an efficiency that is technically feasible to use the effluent end of some of STPs analyzed when checked parameters alone, if fitting in unrestricted urban use, restricted use and urban land use

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In Natal/RN, 68% of the population uses some kind of individual system for their domestic sewers treatment, being that the most used it is septic tank, followed by sumidouro. Every treatment system of sewers, usually used, generates a by-product denominated sludge. That residue presents some components, in its constitution, undesirable under the environmental and sanitary point of view. In such case, to assure that the system treatment has satisfactory results, it is necessary to do the adjusted disposition of the sludge sewage. Several countries are looking for technical alternatives for the use and disposition of residues. Under technical and environmental conditions appropriate, these materials can be used, decreasing the consumption of the natural resources and the treatment need, storage or elimination of the wastes, what decrease the risks created. Some of the alternatives of recycling of the sludge sewage are: the application in the agriculture, in the production of energy and as raw material in the civil construction. This study evaluated asphalt mixtures behavior that partially substituted conventional aggregates by septic tank sludge. The septic tank sludge gave origin to two raw materials called raw sludge and sludge ash. The raw sludge was put as a small aggregate and the sludge ash as filler. In the first experiment it was made a comparison between the mixture with conventional aggregates and the mixtures that replaced sand by raw sludge in the proportions from 5% to 40%. In the second experiment, it was made comparison between mixtures with 1%, 2% and 3% of sludge ash and cement. The stages developed along the study were: physical characterization of the conventional materials; physical, chemistry, thermal, mineralogical characterizations and analysis of environmental risk of the raw sludge; physical characterization and analysis of environmental risk of the sludge ash; analysis of the mixtures performance through its volumetric and mechanical characteristics; forecast of the mixtures susceptibility in the moisture presence. For the grain size composition used and with the percentage asphalt adopted, the mixtures with up to 7,5% of raw sludge in his composition attend to the National Department of Transports Infrastructure (DNIT) specifications. However, in agreement with the mixtures susceptibility in the moisture presence, the mixtures with addition of raw sludge don't present satisfactory acting. In such case, they could be used in arid and semi-arid areas. The raw sludge application in mixtures increased their voids volume and their stability. However, it damaged mixtures adhesiveness. Mixtures with sludge ash and with cement presented similar behavior. However, mixtures with sludge ash presented a better performance than mixtures with cement as for their stability and their tensile strength ratio. The mixture with 1% of sludge ash is better. The wastes studied don't represent environmental risk

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The metal concentrations (Al, Ba, Cd, Cr, Cu, Fe, Mn, Ni, Pb, Zn ) and phosforus(P) had been determined analyzed through Plasma Inductively Coupled Plasme Mass Spectrometer for fine fraction, < 0,63 mm in 22 samples. The sample preparation for analysis had been make in the laboratories of geology of the UFRN. This samples procedures consists in register, dry, bolt and send to analysis in external laboratory (LAKEFIELD GEOSOL) in Belo Horizonte (MG, Brazil). The studied area involves the rivers Trairi, Ararí and Nísia Floresta lagoon, that empties in the sea, situated in the Rio Grande do Norte State. The study objects (Rivers Trairí, Ararí and Nísia Floresta lagoon) receive influences from urban dumpies, agrotoxics and fertilizer, shrimps tank, pastoral, with this, the concentrations of metals (Al, Ba, Cd, Cr, Cu, Fe, Mn, Ni, Pb, P, Zn) (except phosforus) in some points of the study area had been above of the value of reference what it leads to classify them as not polluted to moderately polluted, as the calculated Igeo. In front of discussed, can say about the environmental problems found in Trairi, Ararí and Nísia Floresta Lagoon are still in small scale, since when regard the studied área is over human activity effects

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We analyzed the quality of raw milk from eight dairy farms in Rio Grande do Norte stored in a cooling tank , in order to evaluate methods for determining somatic cell counts (SCC). The Somaticell® kit and a portable Direct Cell Counter (DCC) were compared with each other and with the MilkoScanTM FT+ (FOSS Denmark), which uses Fourier Transform Infrared (FTIR) spectroscopy). Direct cell counter data were processed for somatic cell scores (log-transformed somatic cell count) and analyzed with the SAS®, statistical package , Statistical Analysis System, (SAS, INSTITUTE, 1998). Comparison of means and correlation of somatic cell scores were conducted using Pearson s correlation coefficient and the Tukey Test at 1 %. No significant difference was observed for comparison of means. The correlation between somatic cell scores was significant, that is, 0.907 and 0.876 between the MilkoScanTM FT+ and the Somaticell® kit and Direct Cell Count (DCC) respectively, and 0.943 between the Somaticell® kit and Direct Cell Count (DCC). The methods can be recommended for monitoring the quality of raw milk kept in a cooling tank in the production unit

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to evaluate the influence of milking procedures on the levels of total bacterial count (TBC) in bovine milk. In the first study the influences of procedures for hygienic milking, cleaning of milking equipment and milk cooling tanks on the TBC levels were evaluated. Four bulk samples of milk were collected from each tank in eight properties for TBC analysis, employing the flow cytometry method. A questionnaire was applied in each property to assess the current situation of milking procedures on each production system that took part on this research, followed by training of employees in good agricultural practices in the production of milk and monitoring of the TBC measurements. The methodology for analysis of longitudinal data was considered, focusing on random effects models. The results showed that the handling procedures for milking and the cleanliness of the cooling tank contributed to a further reduction in the levels of TBC raw milk cooling tanks. The second study aimed to describe the percentage of the properties that comply with the Normative Instruction Nº 51 (Brazil s IN 51) with regard to total bacterial count (TBC) in bovine milk. The study was conducted from January 2010 to July 2011. Milk samples were collected from the eight properties selected for TBC analysis by the flow cytometry method. Again, on each property a questionnaire was applied to assess the current situation of milking procedures on each production system that took part on this research, followed by training of employees in good agricultural practices in the production of milk and monitoring of the TBC measurements. The methodology of marginal models based on Generalized Estimate Equations (GEEs) was followed in the statistical analysis. The results showed that the handling procedures of the milking and the cleanliness of the cooling tanks contributed to a considerable percentage of the properties that reached the limits of TBC established by IN 51