22 resultados para Teste crítico


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The technique of ion nitriding, despite being fully consolidated in the industry, has great limitations when applied to the treatment of small parts. This is because effects that occur due to non-uniformity of the electric field, generate localized heating in parts, damaging the uniformity of nitrided layer. In addition, because the samples are treated static parts thereof are untreated. To expand the use of plasma nitriding, this work presents the development, assembly and testing of a prototype plasma reactor with rotatory cathodic cage [patent pending], able to meet these needs, giving the material a uniform treatment and opening doors to industrial scale production. The samples tested with hexagonal nuts are 6.0 mm in diameter, made of stainless steel AISI 304 nitrided at a pressure of 1 mbar in an atmosphere of 20% H2 + 80% N2 for 1 h. After treatment, testing visual inspection, optical microscopy and microhardness were carried out to check the effectiveness of the process for uniformity and hardness of the parts. All samples exhibited uniform color, and matte brownish, unlike the untreated samples, silver color and gloss. The hardness of the surface (top and sides) was 65% and even higher than the original hardness. The nitrided layer showed great uniformity in microstructure and thickness. It is concluded, therefore, that the unit was effective constructed for the purposes for which it was designed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The ability to walk is impaired in obese by anthropometric factors (BMI and height), musculoskeletal pain and level of inactivity. Little is known about the influence of body adiposity and the acute response of the cardiovascular system during whole the 6-minute walk test (6mWT). Objective: To evaluate the effect of anthropometric measures (BMI and WHR waist-to-hip ratio), the effort heart and inactivity in ability to walk the morbidly obese. Materials and Methods: a total 36 morbidly obese (36.23 + 11.82 years old, BMI 49.16 kg/m2) were recruited from outpatient department of treatment of obesity and bariatric surgery in University Hospital Onofre Lopes and anthropometric measurements of obesity (BMI and WHR), pulmonary function, pattern habitual physical activity (Baecke Questionnaire) and walking capacity (6mWT). The patient was checking to measure: heart rate (HR), breathing frequency (BF), peripheral oxygen saturation, level of perceived exertion, systemic arterial pressure and duplo-produto (DP), moreover the average speed development and total distance walking. The data were analysed between gender and pattern of body adiposity, measuring the behavior minute by minute of walking. The Pearson and Spearmam correlation coefficients were calculated, and stepwise multiple Regression examined the predictors of walking capacity. All analyses were performed en software Statistic 6.0. Results: 20 obese patients had abdominal adiposity (WHR = 1.01), waist circumference was 135.8 cm in women (25) and 139.8 cm in men (10). Walked to the end of 6mWT 412.43 m, with no differences between gender and adiposity. The total distance walked by obesity alone was explained by BMI (45%), HR in the sixth minute (43%), the Baecke (24%) and fatigue (-23%). 88.6% of obese (31) performed the test above 60% of maximal HR, while the peak HR achieved at 5-minute of 6mWT. Systemic arterial pressure and DP rised after walking, but with no differences between gender and adiposity. Conclusion: The walk of obese didn´t suffers influence of gender or the pattern of body adiposity. The final distance walked is attributed to excess body weight, stress heart, the feeling of effort required by physical activity and level of sedentary to obese. With a minute of walking, the obeses achieved a range of intensity cardiovascular trainning

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Backgroud: Obesity is a major public health problem and is related to the low physical capacity when obese are compared to no-obese people, however the cause of this limitation is not completely understood. The measurement associated of physiological response to the telemetric 6MWT adds information of metabolic and respiratory system for diagnose of the functional limitation. Objective: Analyze physiological, metabolic and ventilatory responses in women with different body fat during the 6MWT. Methods: 32 women (8 non-obese, 8 Overweight, 8 Obese and 8 morbidly obese) were evaluated for anthropometry, lung function and exercise capacity. Results: Morbidly obese walked the shortest distance (400.2±38.7m), had lower VO2/Kg (12.75±3.20l/Kg/min) and lower R (0.74± 0.11) in the 6MWT compared to other groups. Analyses of metabolic (VO2 and VCO2) and respiratory (VE, VT and BF) during the test did not identify differences between groups. The evaluation of cardiac function (O2 pulse) found higher values in the OM (12.3 ± 4.9ml/bat). Conclusion: The OM had worse performance in the 6MWT compared to other groups. The physical performance may be reduced in this population related to a protocol-dependent response because the speed of 6MWT is self-adjusted allows the individual himself select the intensity of the test, making it set at a speed where there is energy saving

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increase of elderly population in the world and in Brazil has indicated the necessity of health systems capable to evaluate, to diagnose and to intervene in the conditions of health and disease of that segment. During that stage of human development, physical and cognitive changes happen and they are capable to influence the functional acting. It s important to distinguish the limit between the normal and the pathological. Besides the common changes during the aging, biological rhithmicity changes happen, as alterations in the cycle vigil-sleep that can influence in certain tasks performance. This study aimed to verify the influence of the age, of the sex and of the hour in a maze test performance. Eighty individuals were evaluated, 40 youths (20 men and 20 women) and 40 senior (20 men and 20 women). They were separated in 2 different groups that were tested at 9:00 o clock and at 15:00 o clock. Initially they were submitted to health evaluation, cognitive evaluation and of sleep quality and chronotype. They were instructed to accomplish the maze test whose time of execution was timed and registered. Significant differences were observed according to age for the masculine group between elderly in the morning and in the afternoon and in the feminine group between youth and elderly in the test accomplished in the morning and in the afternoon. Significant differences were not observed according to sex and hour of the day and also between attempts. In compare between the 30th and the31st, accomplished in a 15minutes of interval, significant difference was observed just for the elderly group in the morning and in the afternoon. We observed significant correlations in the maze test performance with the cronotype, with the age, with the education and with the cognitive acting. The maze test was capable to detect differences between age in the acting profile and in the evaluation of the information maintenance after 15 minutes, however it was not possible to verify difference between sex and hour of the day. Finally the correlations of the maze test with another varied may indicate your importance as coadjutant instrument in those functions evaluation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigates the chemical species produced water from the reservoir areas of oil production in the field of Monte Alegre (onshore production) with a proposal of developing a model applied to the identification of the water produced in different zones or groups of zones.Starting from the concentrations of anions and cátions from water produced as input parameters in Linear Discriminate Analysis, it was possible to estimate and compare the model predictions respecting the particularities of their methods in order to ascertain which one would be most appropriate. The methods Resubstitution, Holdout Method and Lachenbruch were used for adjustment and general evaluation of the built models. Of the estimated models for Wells producing water for a single production area, the most suitable method was the "Holdout Method and had a hit rate of 90%. Discriminant functions (CV1, CV2 and CV3) estimated in this model were used to modeling new functions for samples ofartificial mixtures of produced water (producedin our laboratory) and samples of mixtures actualproduced water (water collected inwellsproducingmore thanonezone).The experiment with these mixtures was carried out according to a schedule experimental mixtures simplex type-centroid also was simulated in which the presence of water from steam injectionin these tanks fora part of amostras. Using graphs of two and three dimensions was possible to estimate the proportion of water in the production area

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the increasing complexity of software systems, there is also an increased concern about its faults. These faults can cause financial losses and even loss of life. Therefore, we propose in this paper the minimization of faults in software by using formally specified tests. The combination of testing and formal specifications is gaining strength in searches mainly through the MBT (Model-Based Testing). The development of software from formal specifications, when the whole process of refinement is done rigorously, ensures that what is specified in the application will be implemented. Thus, the implementation generated from these specifications would accurately depict what was specified. But not always the specification is refined to the level of implementation and code generation, and in these cases the tests generated from the specification tend to find fault. Additionally, the generation of so-called "invalid tests", ie tests that exercise the application scenarios that were not addressed in the specification, complements more significantly the formal development process. Therefore, this paper proposes a method for generating tests from B formal specifications. This method was structured in pseudo-code. The method is based on the systematization of the techniques of black box testing of boundary value analysis, equivalence partitioning, as well as the technique of orthogonal pairs. The method was applied to a B specification and B test machines that generate test cases independent of implementation language were generated. Aiming to validate the method, test cases were transformed manually in JUnit test cases and the application, created from the B specification and developed in Java, was tested. Faults were found with the execution of the JUnit test cases

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The so-called gravitomagnetic field arised as an old conjecture that currents of matter (no charges) would produce gravitational effects similar to those produced by electric currents in electromagnetism. Hans Thirring in 1918, using the weak field approximation to the Einsteins field equations, deduced that a slowly rotating massive shell drags the inertial frames in the direction of its rotation. In the same year, Joseph Lense applied to astronomy the calculations of Thirring. Later, that effect came to be known as the Lense- Thirring effect. Along with the de Sitter effect, those phenomena were recently tested by a gyroscope in orbit around the Earth, as proposed by George E. Pugh in 1959 and Leonard I. Schiff in 1960. In this dissertation, we study the gravitational effects associated with the rotation of massive bodies in the light of the Einsteins General Theory of Relativity. With that finality, we develop the weak field approximation to General Relativity and obtain the various associated gravitational effects: gravitomagnetic time-delay, de Sitter effect (geodesic precession) and the Lense-Thirring effect (drag of inertial frames). We discus the measures of the Lense-Thirring effect done by LAGEOS Satellite (Laser Geodynamics Satellite) and the Gravity Probe B - GPB - mission. The GPB satellite was launched into orbit around the Earth at an altitude of 642 km by NASA in 2004. Results presented in May 2011 clearly show the existence of the Lense-Thirring effect- a drag of inertial frames of 37:2 7:2 mas/year (mas = milliarcsec)- and de Sitter effect - a geodesic precession of 6; 601:8 18:3 mas/year- measured with an accuracy of 19 % and of 0.28 % respectively (1 mas = 4:84810��9 radian). These results are in a good agreement with the General Relativity predictions of 41 mas/year for the Lense-Thirring effect and 6,606.1 mas/year for the de Sitter effect.