22 resultados para Superfície de impasse


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The structural knowledge of the western portion of the Potiguar Basin is still in its infancy, especially these related to NW-trending fault systems. This paper analyzes the Poço Verde-Caraúbas Fault System, which was initially recognized in subsurface. The activities involved in this study correspond to remote-sensing analysis and, in particular, to the geometric and kinematic analysis of post-rift sequences of the basin. In addition, the study aimed to determine the stress fields operating in the area. The studies were carried out in an area of 1,000 km², located in the western portion of Potiguar Basin along the Poço Verde-Caraúbas Fault System, Rio Grande do Norte State. The remote sensing imagery indicates a predominance of NW-SE-trending lineaments, consistent with the fault system under study, followed by the NE-SW, N-S and E-W directions. The tectonic structures mapped were analyzed only in outcrops of the Jandaíra Formantion. They are joints (filled or not) in all directions, but with predominance of the NW-trending joints. Faults are usually N-S-trending normal faults and NW-SE and NE-SW-trending strike-slip faults. Geodynamic analysis identified two tectonic stress fields: the first field, "Field 1" is represented by an N-S-trending horizontal compression and E-W-trending horizontal extension. This field affected the Potiguar Basin at least until the Miocene. The second field, "Field 2", is represented by an E-W-trending horizontal compression and N-S-trending horizontal extension. This is the present-day stress field and has affected the Potiguar basin since the Pliocene

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to analyze the biological response of titanium surfaces modified by plasma Ar + N2 + H2. Titanium disks grade II received different surface treatments Ar + N2 + H2 plasma, constituting seven groups including only polished samples used as standard. Before and after treatment the samples were evaluated in terms of topography, crystal structure and wettability, using atomic force microscopy, X-ray diffraction, Raman spectroscopy and testing of the sessile drop, respectively. Rich plasma (PRP) was applied to the surfaces modified in culture plates. Images obtained by scanning electron microscopy of the adhered platelets were analyzed to verify the behavior of platelets in the different experimental conditions. We verified that the adition of H2 on plasma atmosphere resulted in more rough surfaces, with round tops. These surfaces, in contrast to that surfaces treated with high concentration of N2, are less propense to platelet aggregation and, consequently, to the formation of thrombus when applied in biomedical devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim : To evaluate and to standardize surface electromyography (sEMG) normalization procedures for respiratory muscles by comparing muscle activation during Maximal Voluntary Isometric Contraction (MVIC) and Maximal Respiratory Pressures (MIP, MEP and sniff test). Methods: Healthy subjects were evalua ted regarding demographics, spirometry and sEMG during the five maneuvers: sniff test, MIP , MEP and Maximal Voluntary Isometric C ontraction (MVIC) of RA, SCM and SC A . For electrode placement, skin was prepared with abrasion, followed by shaving in the foll owing regions for acquisition of el ectromyographic signals: (1) SC M: lower third of the distance between the mastoid process and t he sternoclavicular joint; (2) SC A : 5 cm to the right from the sternoclavicular joint and at this point, up to 2 cm; and (3 ) RA: the level of umbilicus, 4 cm to the right. In electromyographic variables analysis , the data normality was assessed by Shapiro - Wilk test. Comparisons among studied maneuvers were performed by Friedman Test and Dunn’s post - hoc for multiple comparisons a mong inspiratory maneuvers, and Mann Whitney test for expiratory maneuvers. Subgroups differences between genders were performed by Student's t test or Mann - Whitney test according to data normality. Results: 35 subjects participated in the study, b ut 5 we re excluded (BMI> 25 kg/ m²). Sample consisted of 30 subjects (1 5 women), mean age 27.3±7.43 years, BMI 22.2 ± 1.69 kg/m² and spirometric indices within normal limits. Specific MVIC for SCM, SCA and RA showed the highest RMS. When we grouped sample into gender we found no difference among RMS values for the studied SCM maneuvers, while for SCA, MVIC SCM / SCA was the one with the highest RMS and for RA, MVIC RA in men. Once considering women, MVIC SCM/SCA showed the highest RMS for SCM, SCA and MVIC RA showed t he highest value for RA. Conclusion: MVIC for SCM, SCA and RA muscles showed the highest RMS values. When comparing RMS between the studied groups, there was no significant difference between men and women.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to evaluate the microclimate changes surrounding the wind farm Macau Pilot / RN, present in the municipality of the same name. To achieve this goal made use of remote sensing techniques using Landsat - 5 TM and 7 ETM +, from which made it possible evaluation of temperature changes on the surface, this around the park in periods prior to its implementation, to the today. For evaluation of the temperature data that has been generated by applying a template was performed its correlation with field data collection and evaluated the degree of correlation, in order to confirm the validity of the data acquired by satellite. Also held was a characterization of the climate of the region based on the data of this climatological station in Macau. Once collected this data made possible the evaluation of climate change policy in the study region. After validation of the temperature models, an analysis of the generated temperature histograms was performed visually could not identify any significant change. However when analyzing the temperature data at a higher level of detail, a data pattern of behavior was detected for both periods evaluated, yet could not see a distinction between the periods of pre-operation of the park, and post-operation . From this result was levantas hypotheses to explain the behavior of the data, the first of which is the presence of moisture in the soil, and the second to the soil composition. In order to validate the hypotheses were applied PDI techniques, involving a combination of different RGB bands of Landsat 5 and the implementation of Reason bands procedure that might show the elements present on the soil surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aims to develop a methodology for analysis of images using overlapping, which assists in identification of microstructural features in areas of titanium, which may be associated with its biological response. That way, surfaces of titanium heat treated for 08 (eight) different ways have been subjected to a test culture of cells. It was a relationship between the grain, texture and shape of grains of surface of titanium (attacked) trying to relate to the process of proliferation and adhesion. We used an open source software for cell counting adhered to the surface of titanium. The juxtaposition of images before and after cell culture was obtained with the aid of micro-hardness of impressions made on the surface of samples. From this image where there is overlap, it is possible to study a possible relationship between cell growth with microstructural characteristics of the surface of titanium. This methodology was efficient to describe a set of procedures that are useful in the analysis of surfaces of titanium subjected to a culture of cells

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The corrosive phenomenon on reinforced concrete structures is one of the most founded pathologies on the coastal area. With the objective to prevent the process development, or even, retard its beginning, it was studied the application of inorganic covering over concrete surfaces, after its cure, as well as, evaluate the efficiency of the covering applied on the concrete in reducing its porosity of concrete preventing the entrance of aggressive agents to preserve the integrity of the existing armor inside it, comparing the result obtained with the body-of-proof reference, that didn´t receive covering protection. On the concrete production it was used Portland Cement CP II 32, coarse aggregate, fine aggregate and water from the local distributive. Two types of covering were used, one resin based of silicon and solvent and other white cement based, selected sands and acrylic resin. The concrete mixture adopted was 1:1,5:2,5 (cement, fine aggregate, coarse aggregate) and 0.50 water/cement ratio. With the concrete on fresh state was made the experiment test to determinate the workability. On the hardened state was made the concrete resistance experiment, absorption of water and electrochemical experiments, through polarization curves. Also was held optical microscopy and Scanning Electron Microscopy experiments to analyze the layer of the covering applied to the concrete surface and the interface between the concrete and the layer. The obtained results shows that the covering applied to the concrete surface didn´t affect the resistance towards compression. On the absorption of water occurred a diminution of the percentage absorbed, improving the concrete development by making it more impermeable towards the entrance of aggressive agents. The electrochemical experiment results confirmed the water absorption results; the body-of-proof covered presented larger protection towards the development of corrosives process and retarded the evolution of the corrosive phenomenon

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The technique of plasma nitriding by the cathode cage mainly stands out for its ability to produce uniform layers, even on parts with complex geometries. In this study, it was investigated the efficiency of this technique for obtaining duplex surface, when used, simultaneously, to nitriding treatment and thin film deposition at temperatures below 500°C. For this, were used samples of AISI 41 0 Martensitic Stainless Steel and performed plasma treatment, combining nitriding and deposition of thin films of Ti and/or TiN in a plasma atmosphere containing N2-H2. It was used a cathodic cage of titanium pure grade II, cylindrical with 70 mm diameter and 34 mm height. Samples were treated at temperature 420ºC for 2 and 12 hours in different working pressures. Optical Microscopy (OM), Scanning Electron Microscopy (SEM) with micro-analysis by Energy Dispersive Spectroscopy (EDS), X-Ray Diffraction (XRD), Atomic Force Microscopy (AFM) and analysis of Vickers Microhardness were used to investigate coating properties such as homogeneity and surface topography, chemical composition, layer thickness, crystalline phase, roughness and surface microhardness. The results showed there is a direct proportionality between the presence of H2 in plasma atmosphere and the quantity of titanium in surface chemical composition. It was also observed that the plasma treatment at lowpressure is more effective in formation of TiN thin film