17 resultados para Screw Dislocation


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to compare the misfit vertical, horizontal and passivity of zirconia and cobalt-chromium frameworks fabricated for CAD / CAM technology and conventional method of casting. Sixteen frameworks in one-piece, were obtained from a metallic matrix containing three Brånemark compatible implants with regular platform (Titamax Cortical Ti, Neodent). Eight frameworks were fabricated by CAD / CAM system (NeoShape, Neodent): four in zirconia (ZirCAD) and four cobalt-chromium (CoCrcad). Eight other frameworks were obtained by conventional casting method: four cobalt-chromium with UCLA abutment premachined Co-Cr (CoCrUCci) and four cobalt-chromium with UCLA abutment castable (CoCrUCc). The fit vertical, horizontal and passivity by one-screw test were measured using scanning electron microscopy with magnification of 250x. Initially evaluated the passivity by one-screw test and subsequently to assess the vertical and horizontal misfit, tightened all the screws with a torque of 20 Ncm. Mean, standard deviation, minimum and maximum values were calculated for each group. Measurements of horizontal misfit were transformed into cumulative frequency for categorization of the variable and the group later comparison groups. To evaluate the existence of quantitative differences between the groups tested for vertical misfit and passivity, we used the Kruskal-Wallis test. The Mann-Whitney test was used to compare group to group statistical differences (p <0.05). Were observed the respective mean and standard deviation for vertical misfit and passivity in micrometers: ZirCAD (5.9 ± 3.6, 107.2 ± 36), CoCrcad (1.2 ± 2.2, 107.5 ± 26 ), CoCrUCci (11.8 ± 9.8, 124.7 ± 74), CoCrUCc (12.9 ± 11.0, 108.8 ± 85). There were statistical differences in measures of vertical misfit (p = 0.000). The Mann-Whitney test revealed statistical differences (p <0.05) between all groups except between CoCrUCci and CoCrUCc (p = 0.619). No statistical difference was observed for the passivity. In relation to the horizontal misfit groups ZirCAD and CoCrcad did not show best values in relation to CoCrUCci and CoCrUCc. Based on the results it can be concluded that frameworks fabricated by CAD / CAM technology had better values of vertical fit than those manufactured by the casting method, nevertheless, the passivity was not influenced by manufacturing technique and material used. The horizontal fit obtained by frameworks manufactured by CAD / CAM was not superior to those manufactured by casting. A lower variability in vertical adjustment and passivity was observed when frameworks were fabricated by CAD / CAM technology

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To determine the frequency and type of complications related to removable partial denture (RPD) less, Kennedy Class I, over time . Materials and Methods: This observational study consisted of a sample of 65 users PPR lower arches in Kennedy Class I and dentures, rehabilitated in the Department of Dentistry, Federal University of Rio Grande do Norte (UFRN). Patients were followed through periodic controls during periods of 60 days, 6 months and 1 year from installation. After the first year of control had other returns annually. The occurrence of complications or prosthetic failure was observed and recorded in a specific clinical record over 39 months. The patterns of failures observed were classified in the following situations: occurrence of traumatic ulcers after 2 months of installation, lack of retention, fracture or caries in the rest, fracture or dislocation of the artificial teeth, the larger connector fracture, fracture clip fracture support, poor support (need to reline the denture) and prosthesis fracture. Results: The incidence of complications was low frequency, being higher in the second year of use of the prosthesis. Among the complications that occurred more is the loss of retention (31.57%). Failures more severe and difficult to solve as the fracture elements of the metal structure of the PPR had low occurrence and were represented by only one case of the larger connector (5.3%) fractures. Conclusion: Removable partial dentures mandibular free end opposing of the conventional dentures have a low complication rate after 39 months of use when subjected to periodic controls