30 resultados para Prosthesis
Resumo:
The aim of this work was to study a series of 11 different compositions of Ti-Zr binary alloys resistance to aggressive environment, i. e., their ability to keep their surface properties and mass when exposed to them as a way to evaluate their performance as biomaterials. The first stage was devoted to the fabrication of tablets from these alloys by Plasma-Skull casting method using a Discovery Plasma machine from EDG Equipamentos, Brazil. In a second stage, the chemical composition of each produced tablet was verified. In a third stage, the specimen were submitted to: as-cast microstructure analysis via optical and scanning electron microscopy (OM and SEM), x-ray dispersive system (EDS) chemical analysis via SEM, Vickers hardness tests for mechanical evaluation and corrosion resistence tests in a 0.9% NaCl solution to simulate exposition to human saliva monitored by open circuit potential and polarization curves. From the obtained results, it was possible to infer that specimens A1 (94,07 wt% Ti and 5,93% wt% Zr), A4 (77,81 wt % Ti and 22,19 wt % Zr) and A8 (27,83 wt% Ti and 72,17 wt% Zr), presented best performance regarding to corrosion resistance, homogeneity and hardness which are necessary issues for biomaterials to be applied as orthopedic and odontological prosthesis
Resumo:
This study aimed to evaluate patients who underwent placement of zygomatic implants technique by Stella & Warner, considering the survival of conventional and zygomatic implants, sinus health and level of patient satisfaction in relation to oral rehabilitation. We evaluated 28 patients where 14 had received conventional and zygomatic implants, being rehabilitated with implant-fixed dentures (group 1) and 14 were rehabilitated only with conventional implants and implant-fixed dentures (group 2). The study had four phases, represented by radiographic evaluation of implants (stage I), clinical evaluation (stage II), assessing the health of the maxillary sinus (stage III) and a questionnaire to measure satisfaction of rehabilitation with fixed prosthesis implant Total -backed (stage IV). Group 2 underwent only stage IV, while group 1 participated in all stages. Descriptive analysis and statistics were performed, using the t test for independent samples in the evaluation of phase IV. The results demonstrated that the technique of Stella & Warner proved effective, allowing a high survival rate of conventional implants and zygomatic (100%), considering a minimum follow-up of 15 months and maximum 53 months after prosthetic rehabilitation. There were no pathological changes in tissues periimplants conventional and zygomatic implants analyzed. Radiographic findings showed satisfactory levels bone implants in the oral rehabilitation with conventional zygomatic implants and a good positioning of the apex of the zygomatic implants over the zygomatic bone. The presence of the zygomatic implant did not cause sinus and the t test showed a satisfaction index lower in group 1 compared with group 2. The zygomatic implant placement technique by Stella & Warner proved to be a predictable technique with high survival rate in patients with atrophic jaws, necessitating long-term follow-up to confirm the initial findings of the study
Resumo:
The evaluation criteria of the cases treated with dental implants are based on clinical and radiographic tests. In this context it is important to conduct research to determine prognosis of different types of prosthetic rehabilitation and determination of the main problems affecting this type of treatment. Thus, the objective of this study was to assess the prosthetic conditions of individuals rehabilitated with implant-supported prosthesis. In this cross-sectional study 153 patients were treated, accounting for a sample of 509 implants. The failures were observed by clinical and radiographic examination. The results showed that the fracture (0.2%) loss (0.4%) and loosening of the screws (3.3%) were failures are less frequent. The fracture structures as the resin (12.4%), porcelain (5.5%) and metallic (1.5%), loss of resin that covers the screw (23.8%) and loss of retention overdentures on implants (18.6%) had a higher occurrence. The failure of adaptation between the abutment and the implant (6.9%) and especially between the prosthesis and the abutment (25.4%) had a high prevalence and, when related to other parameters showed a significant association, particularly with the cemented prosthesis (OR = 6.79). It can be concluded that to minimize the appearance of failures, protocols must be observed from diagnosis to the settlement and control of prostheses on implants, particularly with respect to technical steps of the making of the prosthesis and care in radiographic evaluating the fit between their components
Resumo:
The aim of this study was to compare the misfit vertical, horizontal and passivity of zirconia and cobalt-chromium frameworks fabricated for CAD / CAM technology and conventional method of casting. Sixteen frameworks in one-piece, were obtained from a metallic matrix containing three Brånemark compatible implants with regular platform (Titamax Cortical Ti, Neodent). Eight frameworks were fabricated by CAD / CAM system (NeoShape, Neodent): four in zirconia (ZirCAD) and four cobalt-chromium (CoCrcad). Eight other frameworks were obtained by conventional casting method: four cobalt-chromium with UCLA abutment premachined Co-Cr (CoCrUCci) and four cobalt-chromium with UCLA abutment castable (CoCrUCc). The fit vertical, horizontal and passivity by one-screw test were measured using scanning electron microscopy with magnification of 250x. Initially evaluated the passivity by one-screw test and subsequently to assess the vertical and horizontal misfit, tightened all the screws with a torque of 20 Ncm. Mean, standard deviation, minimum and maximum values were calculated for each group. Measurements of horizontal misfit were transformed into cumulative frequency for categorization of the variable and the group later comparison groups. To evaluate the existence of quantitative differences between the groups tested for vertical misfit and passivity, we used the Kruskal-Wallis test. The Mann-Whitney test was used to compare group to group statistical differences (p <0.05). Were observed the respective mean and standard deviation for vertical misfit and passivity in micrometers: ZirCAD (5.9 ± 3.6, 107.2 ± 36), CoCrcad (1.2 ± 2.2, 107.5 ± 26 ), CoCrUCci (11.8 ± 9.8, 124.7 ± 74), CoCrUCc (12.9 ± 11.0, 108.8 ± 85). There were statistical differences in measures of vertical misfit (p = 0.000). The Mann-Whitney test revealed statistical differences (p <0.05) between all groups except between CoCrUCci and CoCrUCc (p = 0.619). No statistical difference was observed for the passivity. In relation to the horizontal misfit groups ZirCAD and CoCrcad did not show best values in relation to CoCrUCci and CoCrUCc. Based on the results it can be concluded that frameworks fabricated by CAD / CAM technology had better values of vertical fit than those manufactured by the casting method, nevertheless, the passivity was not influenced by manufacturing technique and material used. The horizontal fit obtained by frameworks manufactured by CAD / CAM was not superior to those manufactured by casting. A lower variability in vertical adjustment and passivity was observed when frameworks were fabricated by CAD / CAM technology
Falhas e complicações com o uso de prótese parcial removível inferior de extremidade livre bilateral
Resumo:
Aim: To determine the frequency and type of complications related to removable partial denture (RPD) less, Kennedy Class I, over time . Materials and Methods: This observational study consisted of a sample of 65 users PPR lower arches in Kennedy Class I and dentures, rehabilitated in the Department of Dentistry, Federal University of Rio Grande do Norte (UFRN). Patients were followed through periodic controls during periods of 60 days, 6 months and 1 year from installation. After the first year of control had other returns annually. The occurrence of complications or prosthetic failure was observed and recorded in a specific clinical record over 39 months. The patterns of failures observed were classified in the following situations: occurrence of traumatic ulcers after 2 months of installation, lack of retention, fracture or caries in the rest, fracture or dislocation of the artificial teeth, the larger connector fracture, fracture clip fracture support, poor support (need to reline the denture) and prosthesis fracture. Results: The incidence of complications was low frequency, being higher in the second year of use of the prosthesis. Among the complications that occurred more is the loss of retention (31.57%). Failures more severe and difficult to solve as the fracture elements of the metal structure of the PPR had low occurrence and were represented by only one case of the larger connector (5.3%) fractures. Conclusion: Removable partial dentures mandibular free end opposing of the conventional dentures have a low complication rate after 39 months of use when subjected to periodic controls
Resumo:
The objective of this research was to evaluate the passivity and strain induced in infrastructures screwed on abutments, made by CAD/CAM technology, and to compare these samples with parts manufactured by conventional casting. Using CAD/CAM technology, 4 samples were made from zirconia (Zircad) and 4 samples were manufactured from cobaltchrome (CoCrcad). The control groups were 4 specimens of cobalt-chrome, made by onepiece casting (CoCrci), for a total of 12 infrastructures. To evaluate the passivity, the infraestructures were installed on the abutments. One end was tightened and the vertical gap between the infrastructure and the prosthetic abutment was measured with scanning electron microscopy (250×). The mean strain in these infrastructures was analyzed via the photoelasticity test. A significant difference (p = 0.000) in passivity was observed between the control (CoCrci) and sample groups (CoCrcad and CoCrci). CoCrcad exhibited the best value of passivity (48.76 ± 13.45 μm) and CoCrci the worst (187.55 ± 103.63 μm), Zircad presented an intermediate value (103.81 ± 43.15 μm). When compared to the other groups, CoCrci showed the highest mean strain around the implants (17.19 ± 7.22 kPa). It was concluded that the zirconia infrastructure made by CAD / CAM showed a higher vertical marginal misfit than those made in cobalt-chromium alloy with the same methodology, however, the tension generated in the implants was similar. The CAD/CAM technology is more accurate for passivity and mean strain of infrastructure screwed on abutments than conventional manufacturing techniques
Resumo:
Objectives To evaluate the change in masticatory efficiency and quality of life of patients treated with mandibular Kennedy class I removable partial dentures (RPDs) and maxillary complete dentures at the Department of Dentistry of the Federal University of Rio Grande do Norte. Materials and methods A total of 33 Kennedy class I patients were rehabilitated with maxillary complete dentures, and mandibular RPDs were selected for this non-randomized prospective intervention study. The patients had a mean age of 59.1 years. Masticatory efficiency was evaluated by colorimetric assay using fuchsin capsules. The measurements were conducted at baseline and 2 and 6 months after prosthesis insertion. Quality of life was evaluated using the Oral Health Impact Profile (OHIP-14) at baseline and 6 months after denture insertion. The Kolmogorov-Smirnov normality test was applied. Masticatory efficiency was evaluated by repeated measures ANOVA. Oral health-related quality of life was compared using the paired t test. Results There was no statistically significant difference in masticatory efficiency after denture insertion (p = 0.101). Significant differences were found (p = 0.010) for oral health-related quality of life. A significant improvement in psychological discomfort (p < 0.01) and psychological disability (p < 0.01) was observed. Mean difference value (95 % confidence interval) was 6.8 (3.8 to 9.7) points, reflecting a low impact of oral health on quality of life, considering the 0–56 range of variation of the OHIP-14 and a Cohen’s d of 1.13. Conclusion According to the results of the present study, rehabilitation with Kennedy class I RPDs and complete dentures did not influence masticatory efficiency but improved oral health-related quality of life. Clinical relevance The association between the patient’s quality of life and the masticatory efficiency is important for treatment predictability.
Resumo:
This study presents a simple, fast and low cost technique for fabrication new conventional dentures from the duplication of old prosthesis in use by the patient. Colorless acrylic resin was poured into the moulds obtained by duplication of prosthesis. With the replicas obtained a functional impressions using polyether should be performed and they are stabilized with occlusal registration in acrylic resin. The molds need to be castings and mounted on an semi-adjustable articulator. The artificial teeth are positioned with the assistance of a guide made condensation silicone to reproduce the positioning of the teeth of the old prosthesis and fixed with wax 7. After approval of the teeth on the trial in wax, without adjustment of the planes, the prosthesis may be processed in the laboratory. After occlusal adjustment in the articulator the same can be installed.
Resumo:
Objective: To evaluate the planning and quality of plaster models for fabricati on of removable parti al dentures received from three commercial prosthodonti c laboratories located in the city of João Pessoa, PB, Brazil, which perform the casting procedures in their facilities. Methods: Forty 40 plaster models were photographed per laboratory, totalizing 120 models. The evaluation was performed using two questi onnaires, one designed for the dental prosthesis technicians, and another applied by the investigator for the visual evaluati on of the models. Data were analyzed using the SPSS soft ware version 13.0. Results: Ninety-two (76.7%) models did not present planning. In addition, no model presented references of insertion plane or guide pins. Calculati on of the mouth preparati on index (MPI) to evaluate the distribution of the oclusal and cingulum abutments or rests showed that 86 (71.7%) models were classifi ed as poor, 23 (19.2%) models as good and only 11 (9,.2%) models as acceptable. Defects were found in 102 (85%) models. Conclusion: The prosthodontists are not preparing the mouth of their pati ents, neglecti ng the planning of removable partial dentures, and passing this responsibility to the dental prosthesis technicians. In addition, the quality of the models sent to the laboratories was unsatisfactory.
Resumo:
Objective: To evaluate the planning and quality of plaster models for fabricati on of removable parti al dentures received from three commercial prosthodonti c laboratories located in the city of João Pessoa, PB, Brazil, which perform the casting procedures in their facilities. Methods: Forty 40 plaster models were photographed per laboratory, totalizing 120 models. The evaluation was performed using two questi onnaires, one designed for the dental prosthesis technicians, and another applied by the investigator for the visual evaluati on of the models. Data were analyzed using the SPSS soft ware version 13.0. Results: Ninety-two (76.7%) models did not present planning. In addition, no model presented references of insertion plane or guide pins. Calculati on of the mouth preparati on index (MPI) to evaluate the distribution of the oclusal and cingulum abutments or rests showed that 86 (71.7%) models were classifi ed as poor, 23 (19.2%) models as good and only 11 (9,.2%) models as acceptable. Defects were found in 102 (85%) models. Conclusion: The prosthodontists are not preparing the mouth of their pati ents, neglecti ng the planning of removable partial dentures, and passing this responsibility to the dental prosthesis technicians. In addition, the quality of the models sent to the laboratories was unsatisfactory.
Resumo:
The gingiva, part of the masticatory mucosa tissue that covers the alveolar process and surrounds the cervical portion of teeth, has a definitive shape and texture associated with the eruption of teeth. Therefore, it must be included in rehabilitative planning, as the absence of papillae induces problems with esthetics, phonetics and food-impaction. The purpose of the present study was to approach the indications, limitations and techniques for making a removable artificial gingiva made of acrylic resin, by reporting on a clinical case. The patient, a 29-year-old woman, with the sequelae of periodontal disease, presented loss of interdental papilla causing “black holes”. She was dissatisfied with the esthetic appearance of her teeth, and also complained of long teeth and air escaping when she spoke. As treatment, prosthetic reconstruction was proposed, by means of a removable artificial gingiva (gingival epithesis) to simulate the presence of interdental papillae, providing better esthetics and phonetics. Gingival epithesis is an easily made, inserted and hygienically cleaned appliance that provides a simple and safe alternative solution for cases in which surgical techniques are limited.
Resumo:
The gingiva, part of the masticatory mucosa tissue that covers the alveolar process and surrounds the cervical portion of teeth, has a definitive shape and texture associated with the eruption of teeth. Therefore, it must be included in rehabilitative planning, as the absence of papillae induces problems with esthetics, phonetics and food-impaction. The purpose of the present study was to approach the indications, limitations and techniques for making a removable artificial gingiva made of acrylic resin, by reporting on a clinical case. The patient, a 29-year-old woman, with the sequelae of periodontal disease, presented loss of interdental papilla causing “black holes”. She was dissatisfied with the esthetic appearance of her teeth, and also complained of long teeth and air escaping when she spoke. As treatment, prosthetic reconstruction was proposed, by means of a removable artificial gingiva (gingival epithesis) to simulate the presence of interdental papillae, providing better esthetics and phonetics. Gingival epithesis is an easily made, inserted and hygienically cleaned appliance that provides a simple and safe alternative solution for cases in which surgical techniques are limited.
Resumo:
Background The chronic cumulative nature of caries makes treatment needs a severe problem in adults. Despite the fact that oral diseases occur in social contexts, there are few studies using multilevel analyses focusing on treatment needs. Thus, considering the importance of context in explaining oral health related inequalities, this study aims to evaluate the social determinants of dental treatment needs in 35–44 year old Brazilian adults, assessing whether inequalities in needs are expressed at individual and contextual levels. Methods The dependent variables were based on the prevalence of normative dental treatment needs in adults: (a) restorative treatment; (b) tooth extraction and (c) prosthetic treatment. The independent variables at first level were household income, formal education level, sex and race. At second level, income, sanitation, infrastructure and house conditions. The city-level variables were the Human Development Index (HDI) and indicators related to health services. Exploratory analysis was performed evaluating the effect of each level through calculating Prevalence Ratios (PR). In addition, a three-level multilevel modelling was constructed for all outcomes to verify the effect of individual characteristics and also the influence of context. Results In relation to the need for restorative treatment, the main factors implicated were related to individual socioeconomic position, however the city-level contextual effect should also be considered. Regarding need for tooth extraction, the contextual effect does not seem to be important and, in relation to the needs for prosthetic treatment, the final model showed effect of individual-level and city-level. Variables related to health services did not show significant effects. Conclusions Dental treatment needs related to primary care (restoration and tooth extraction) and secondary care (prosthesis) were strongly associated with individual socioeconomic position, mainly income and education, in Brazilian adults. In addition to this individual effect, a city-level contextual effect, represented by HDI, was also observed for need for restorations and prosthesis, but not for tooth extractions. These findings have important implications for the health policy especially for financing and planning, since the distribution of oral health resources must consider the inequalities in availability and affordability of dental care for all.
Resumo:
Traditional methods for dentures fabrication require a wide clinical and laboratory procedures; however, there is no scientific evidence that these methods can produce better results when compared with simplified methods. Aim: To evaluate the effectiveness of a simplified methods for denture fabrication, comparing it to the traditional one through masticatory efficiency and prosthesis quality. Method: A randomized controlled trial was conducted with 50 patients, 25 rehabilitated with prosthesis produced by traditional technique and 25 rehabilitated by a simplified technique. The masticatory efficiency was evaluated by colorimetric method, using chewing capsules. The quality of prosthesis was obtained using a reliable and reproducible instrument. Statistical analysis of the masticatory efficiency and quality of the prosthesis was obtained by the Mann-Whitney test. Results: 39 patients completed the study, 18 on traditional group and 21 on simplified group. There was no difference between groups for the masticatory efficiency (p = 0.835) and the quality of the prosthesis (p = 0672). The evaluation of the overall quality of the prosthesis according to oral conditions, demonstrated significant difference on the height of the mandibular ridges (p = 0.010) and mandibular muscle attachments (p = 0.039). Conclusion: Complete dentures fabricated by simplified method were considered effective from the point of view of masticatory efficiency and quality of prosthetics, with results similar to those made by the traditional method.
Resumo:
Traditional methods for dentures fabrication require a wide clinical and laboratory procedures; however, there is no scientific evidence that these methods can produce better results when compared with simplified methods. Aim: To evaluate the effectiveness of a simplified methods for denture fabrication, comparing it to the traditional one through masticatory efficiency and prosthesis quality. Method: A randomized controlled trial was conducted with 50 patients, 25 rehabilitated with prosthesis produced by traditional technique and 25 rehabilitated by a simplified technique. The masticatory efficiency was evaluated by colorimetric method, using chewing capsules. The quality of prosthesis was obtained using a reliable and reproducible instrument. Statistical analysis of the masticatory efficiency and quality of the prosthesis was obtained by the Mann-Whitney test. Results: 39 patients completed the study, 18 on traditional group and 21 on simplified group. There was no difference between groups for the masticatory efficiency (p = 0.835) and the quality of the prosthesis (p = 0672). The evaluation of the overall quality of the prosthesis according to oral conditions, demonstrated significant difference on the height of the mandibular ridges (p = 0.010) and mandibular muscle attachments (p = 0.039). Conclusion: Complete dentures fabricated by simplified method were considered effective from the point of view of masticatory efficiency and quality of prosthetics, with results similar to those made by the traditional method.