21 resultados para Performance Measurement System, PMS, review PMS, KPIs
Resumo:
This paper presents the validation of the Performance Indicator System for Projects under Construction - SIDECC. The goal was to develop a system of performance indicators from the macroergonômica approach, considering criteria of usefulness, practicality and applicability and the concept of continuous improvement in the construction industry. The validation process SIDECC consisted of three distinct models. Modeling I corresponded to the theoretical development and validation of a system of indicators. Modeling II concerns the development and validation of multi- indicator system. For this modeling, we used the Mother of Use and Importance and Multivariate Analysis. Modeling III corresponded to the validation situated, which consisted of a case study of a work of construction of buildings, which were applied and analyzed the results of modeling II. This work resulted in the development of an applied and tested for the construction of an integrated system of performance indicators methodology, involving aspects of production, quality, environmental, health and safety. It is inferred that the SIDECC can be applied, in full or in part, the construction companies as a whole, as well as in other economic sectors
Resumo:
Composites based on PEEK + PTFE + CARBON FIBER + Graphite (G_CFRP) has increased application in the top industries, as Aerospace, Aeronautical, Petroleum, Biomedical, Mechanical and Electronics Engineering challenges. A commercially available G_CFRP was warmed up to three different levels of thermal energy to identify the main damage mechanisms and some evidences for their intrinsic transitions. An experimental test rig for systematize a heat flux was developed in this dissertation, based on the Joule Effect. It was built using an isothermal container, an internal heat source and a real-time measurement system for test a sample by time. A standard conical-cylindrical tip was inserted into a soldering iron, commercially available and identified by three different levels of nominal electrical power, 40W (manufacturer A), 40W (manufacturer B), 100W and 150W, selected after screening tests: these power levels for the heat source, after one hour of heating and one hour of cooling in situ, carried out three different zones of degradation in the composite surface. The bench was instrumented with twelve thermocouples, a wattmeter and a video camera. The twelve specimens tested suffered different degradation mechanisms, analyzed by DSC (Differential Scanning Calorimetry) and TG (Thermogravimetry) techniques, Scanning Electron Microscopy (SEM) and Energy-Dispersive X-Rays (EDX) Analysis. Before and after each testing, it was measured the hardness of the sample by HRM (Hardness Rockwell M). Excellent correlations (R2=1) were obtained in the plots of the evaporated area after one hour of heating and one hour of cooling in situ versus (1) the respective power of heat source and (2) the central temperature of the sample. However, as resulting of the differential degradation of G_CFRP and their anisotropy, confirmed by their variable thermal properties, viscoelastic and plastic properties, there were both linear and non-linear behaviour between the temperature field and Rockwell M hardness measured in the radial and circumferential directions of the samples. Some morphological features of the damaged zones are presented and discussed, as, for example, the crazing and skeletonization mechanism of G_CFRP
Resumo:
The continuous development of instruments and equipment used as tools or torque measurement in the industry is demanding more accurate techniques in the use of this kind instrumentation, including development of metrological characteristics in torque measurement. The same happens with the needs in calibration services. There is a diversity of methods of hand torque tools in the market with different measuring range but without complaining with technical standards in terms of requirements of quality and reliability. However, actually there is no choice of a torque measuring standard that fulfils, with low cost, the needs for the calibration of hand torque tools in a large number of ranges. The objective of this thesis is to show the development and evaluation of a torque measuring standard device with a conception to allow the calibration of hand torque tools with three levels of torque with an single instrument, promoting reduction of costs and time in the calibration, also offering reliability for the evaluation of torque measuring instrument. To attend the demand in the calibration of hand torque tools it is necessary that the calibration laboratories have a big collection of torque measuring standards, to fulfills the needs of the costumer, what is very costly. The development of this type of torque measuring standard revealed a viable technique and economically making possible the calibration of hand torque tools in different nominal ranges through a single measurement system versatile, efficient and of easy operation
Resumo:
This paper prese nts the validation of the Performance Indicator System for Projects under Construction - SIDECC. The goal was to develop a system of performance indicators from the macroergonômica approach, con sidering criteria of usefulness , practicality and applicabilit y and the concept of continuous improveme nt in the construction industry . The validation process SIDECC consisted of three disti nct models . Modeling I corresponded to the theoretical development and valid ation of a system of indicators . Modeling II concern s the development and valida tion of multi - indicator system . For this modeling, we used the Mother of Use and Importance and Multivariate Analysis . Modeling III correspo nded to the validation situated , which consisted of a case study of a wo rk of construct ion of buildings , which were applied and anal yzed the results of modeling II . This work resulted in the development of an applied and tested for the construction of an integrated system of per formance indicators methodology , involving aspects of production , quality , e nvironmental, health and safety . It is inferred that the SIDECC can be applied, in full or in part , the construction companies as a whole, as we ll as in other economic sectors .
Resumo:
The aim of this study was to propose a Performance Evaluation System for outsourced employees of the University Restaurant of the Federal University of Rio Grande do Norte to supply the lack of evaluative instruments. According to Provision of Services Contract nº050/2010 and nº055/2011 of FURN with SAFE LOCAÇÃO DE MÃO DE OBRA LTDA ME, it is the hired company to promote periodic functional performance evaluation of the outsourced employees, but this is not done. The performance evaluation process serves to evaluate if the employees are making their tasks according to the organizations’ objectives and goals, besides that helps to find service failures and capacity of employees demands, thus contributing to improve work conditions and the global performance of the organizations. To elaborate the proposal of evaluation, it was chosen an action research with the participation of all stakeholders, employees and managers from UR. On data collect, first, outsourced employees and management servers were interviewed, in order to raise existing perceptions about performance evaluation aspects. From these data and the work routine observation, a proposal of performance evaluation was elaborated, that was appreciated, criticized and adjusted by the actors involved (employees and managers) to the final formulation of the instrument. This study also presents the necessary steps to the implementation of the Performance Evaluation System. The proposed Performance Evaluation System can be applied to the FURN assuming this process, after modification of contract terms and the approval by the ADCON. It also can serve as an example to others units that works with the provision of outsourced services, enabling so the performance evaluation to be part of the management policy of all people working in FURN.
Resumo:
Nowadays, evaluation methods to measure thermal performance of buildings have been developed in order to improve thermal comfort in buildings and reduce the use of energy with active cooling and heating systems. However, in developed countries, the criteria used in rating systems to asses the thermal and energy performance of buildings have demonstrated some limitations when applied to naturally ventilated building in tropical climates. The present research has as its main objective to propose a method to evaluate the thermal performance of low-rise residential buildings in warm humid climates, through computational simulation. The method was developed in order to conceive a suitable rating system for the athermal performance assessment of such buildings using as criteria the indoor air temperature and a thermal comfort adaptive model. The research made use of the software VisualDOE 4.1 in two simulations runs of a base case modeled for two basic types of occupancies: living room and bedroom. In the first simulation run, sensitive analyses were made to identify the variables with the higher impact over the cases´ thermal performance. Besides that, the results also allowed the formulation of design recommendations to warm humid climates toward an improvement on the thermal performance of residential building in similar situations. The results of the second simulation run was used to identify the named Thermal Performance Spectrum (TPS) of both occupancies types, which reflect the variations on the thermal performance considering the local climate, building typology, chosen construction material and studied occupancies. This analysis generates an index named IDTR Thermal Performance Resultant Index, which was configured as a thermal performance rating system. It correlates the thermal performance with the number of hours that the indoor air temperature was on each of the six thermal comfort bands pre-defined that received weights to measure the discomfort intensity. The use of this rating system showed to be appropriated when used in one of the simulated cases, presenting advantages in relation to other evaluation methods and becoming a tool for the understanding of building thermal behavior