28 resultados para Dinamómetro portátil


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The Pilates Method is a modality of exercise that has been growing in recent decades, but few researches has been conducted with elderly and little is known about its benefits in this population. Objective: To evaluate the effect of a program of Mat Pilates exercises in muscle performance and postural balance in elderly women. Materials and Method: This is a randomized controlled trial that evaluated the muscle performance (isokinetic dynamometer Biodex System 3 Pro®) and postural balance (Balance Master System®) of 33 women aged 65-80 years. The experimental group (EG) participated of a 12-week program of Mat Pilates exercises with two weekly sessions. Data normality was verified by the Shapiro - Wilk test and were adopted p value < 0.05 as significance level. Results: There were no differences between groups after training. However, the EG showed an increase in the values of extension and flexion average power to 60 ° / s after training (32.19 W to 37.04 W and 14.48 W to 17.56 W, respectively). Conclusion: The proposed exercise program was not effective in the total work and average power of flexor and extensor of the knee, as well as static and dynamic balance of participants

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to investigate the immediate effects of laser therapy on neuromuscular performance in healthy subjects after a muscle fatigue. This is a clinical trial, controlled, randomized, blinded, attended by 80 volunteers of both genders, healthy, with ages between 18 to 28 years. Initially the volunteers performed an initial evaluation (EV1) using electromyography in the biceps muscle, associated with assessment in isokinetic dynamometry with 5 concentric contractions (60 °/s) for elbow flexion. The subjects were randomly allocated into 4 groups: G1 (control, n = 20), G2 (placebo, n = 20), G3 (pre-fatigue laser, n = 20), and G4 (post fatigue laser, n = 20). The muscular fatigue protocol had 30 concentric isokinetic contractions (120 °/s). We used a 808 nm laser, power of 100 mW, applied at the belly of the biceps muscle. After the speeches the volunteers performed a final evaluation (EV2). Test was applied to two-way ANOVA with post hoc Turkey, with a significance level of 5%. There was no significant difference in electromyographic evaluation. In dynamometric evaluation showed a drop in peak torque, peak torque normalized to body weight (p <0.001) and average power (p <0, 05) between the initial and final evaluations in control. Among the groups there was a significant difference between the control and the other groups in relation to peak torque (p <0.05), peak torque to body weight (p <0.001) and average power (p <0.05). Therefore, the low intensity laser therapy does not alter the immediate neuromuscular performance after fatigue

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Exercise-induced muscle damage mainly affects individuals who returned to physical activity after a time without practicing it or had some kind of exhaustive exercise, particularly eccentric exercise. To evaluate the effect of cryotherapy and laser therapy in response to muscle damage induced by eccentric exercise on the biceps muscle. This was a randomized clinical trial consisting of 60 female subjects. All subjects initially underwent an evaluation consisting of perimetry, measurement of pain sensation (via algometry and visual analogue scale), electromyography and dynamometry. Then the subjects performed an exercise protocol on the isokinetic dynamometer consisting of 2 sets of 10 eccentric elbow flexors contraction at 60 °/s. Completed this protocol, an intervention was held according to a previously random group distribution: control group (no intervention), cryotherapy group and laser therapy group. Finally, subjects were re-evaluated immediately and 48 hours after the intervention protocol, except for Visual Analogue Scale (VAS), which was also evaluated 24 hours after exercise. The circumference of the limb, the pain sensation (VAS and algometry), the muscle activation amplitude (via Root Mean Square - RMS), median frequency, peak torque normalized per body weight, average peak torque, power and work were analyzed. The median frequency immediately after the intervention protocol on the cryotherapy group was the only variable that showed inter and intra-group differences; the remaining variables showed only intragroup differences. The perimetry values did not change immediately after the protocol on the groups which underwent cryotherapy and laser therapy, however, there was an increase after 48 hours; algometry values decreased in all groups for 48 hours and the VAS values increased 24 and 48 hours also for all groups. Regarding RMS no significant change was observed. For dynamometry, peak torque normalized per body weight and average peak torque had a similar behavior, with a reduction in the post protocol that has remained after 48 hours. For the power and work, a decrease was observed immediately after the protocol with a further reduction after 48 hours. Cryotherapy and laser therapy does not alter the muscle damage response, except for the perimetry values immediately after exercise.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We analyzed the quality of raw milk from eight dairy farms in Rio Grande do Norte stored in a cooling tank , in order to evaluate methods for determining somatic cell counts (SCC). The Somaticell® kit and a portable Direct Cell Counter (DCC) were compared with each other and with the MilkoScanTM FT+ (FOSS Denmark), which uses Fourier Transform Infrared (FTIR) spectroscopy). Direct cell counter data were processed for somatic cell scores (log-transformed somatic cell count) and analyzed with the SAS®, statistical package , Statistical Analysis System, (SAS, INSTITUTE, 1998). Comparison of means and correlation of somatic cell scores were conducted using Pearson s correlation coefficient and the Tukey Test at 1 %. No significant difference was observed for comparison of means. The correlation between somatic cell scores was significant, that is, 0.907 and 0.876 between the MilkoScanTM FT+ and the Somaticell® kit and Direct Cell Count (DCC) respectively, and 0.943 between the Somaticell® kit and Direct Cell Count (DCC). The methods can be recommended for monitoring the quality of raw milk kept in a cooling tank in the production unit

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The literature concerning color vision shows a trichromatic advantage in detecting ripe fruits and young leaves, but there are contradictory results. There is also the suggestion of this type of vision being adapted to perceive socio-sexual signals. Indeed, Old World primates utilize the skin color of conspecifics as a factor of attraction. But in New World primates there is no record of a coloration signal in the body that can be utilized by other group members. The present study aims to: 1- test whether there is a relation between coloration of body regions and ovulatory cycle in female Callithrix jacchus; 2- Determine if this species uses visual signals to choose mates that are sexually receptive. We collected feces from six females during one month to quantify progesterone concentration by EIA. Body region coloration was measured using a portable spectrometer and modeled to obtain the quantum catch of each photoreceptor, the opponency channels and chromatic distance between the points in units of JND. We recorded the behavior of six males exposed to three pairs of females with a cycling and a non-cycling female in each pair using a transparent plexiglass apparatus. The color of different body regions presented a correlation between progesterone concentration and the yellow-blue and red-green visual axes, with the genitalia as the region showing the highest correlation. The visual axis more apt to see the color variations was the yellow-blue in dichromats, and in trichromats were the red-green to face, yellow-blue to abdomen and both chromatic axes to genitalia. There was no difference in the signal detectability between trichromats and dichromats, but the perception pattern differed between the phenotypes, with a better signal detection by the dichromat phenotype 562 and the trichromat phenotype 543/562. During the behavioral experiments males presented longer gaze duration in periods of experimental manipulation and gaze duration was always longer towards cycling females compared to non-cycling females. Male locomotion during experimental manipulation was greater than in the control only during the periovulatory period of the female, indicating greater excitement. The behavior of cycling females was more active than the behavior of the non-cycling ones regarding locomotion and touching of the plexiglass division of the apparatus. Male gaze duration to cycling females increased with decreasing progesterone concentration, but none of the coloration parameters was correlated to the mate preference exhibited. This coloration signal can transmit information to animals of the group about fertility of female. Different from the intense red of the genitalia swellings of Old World primates, marmoset female genitalia became more bluish-green in the fertile period. Males chose fertile females and were able to visually identify the periovulatory period of females. Choice is related to progesterone concentration, but our results do not show relation between coloration and mate preference. Maybe some behavioral measure is associated with the choice

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Shift work consists of an array of unusual work hours, such as evenings and weekends, and increasing workload, in order to meet the uninterrupted production, which leads to changes in the quality, duration and regularity of sleep. Research indicates that sleep alteration cause cognitive processes to become slower, unstable and prone to errors, leading to loss of cognitive functions such as visuospatial perception. In this sense, this research aimed to evaluate sleep quality and its relation to visuospatial perception in workers in alternating shifts. Participants were 21 panel operators in a petrochemical company, male, aged 19-53 years. All participants were subjected to schedules of alternating shifts (day and night) of 12 nonstop hours and data were collected from 10 workers who were assigned to the day shift and 11 workers assigned to the night shift. For the sleep evaluation were used the Sleep Diary, the Sleep Habits Questionnaire, the Chronotype Identification Questionnaire and the Pittsburgh Sleep Quality Index (PSQI). The visuospatial skills were assessed using the Rey Complex Figure Test and attention was assessed using a portable version of the Psychomotor Vigilance Task (PVT). The results showed that the general sample of workers obtained poor sleep quality on working days and good sleep quality during the work break. There was shortened sleep duration in the work week and appropriate duration in the work break. No losses were found in the workers visuospatiality, but the good quality of sleep during the work break was correlated to adequate visuospatial performance, for the day shift workers. The attention performance oscillated throughout the work hours, especially on the night shift. It is concluded that the alternating shifts work scheme can be detrimental to the sleep quality workers and a good sleep quality can contribute to a better visuospatial performance

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study analyzed measurements of the aeolian transport using vertical sand traps across the field dunes of Jenipabu, in the municipality of Extremoz, Rio Grande do Norte state to the North of Natal city. These measurements were used as parameters for the sand aeolian transport in the region. Before the field trips a map of landscape units was made. Three visits to the field were done in September 2011 (field a - the 13th, field b - the 21st, field c - the 29th), period of the year with the highest wind speed, and another in December 8th, 2011 (field d ) when the wind speed starts to decrease. The sand traps used were of the type "I" with collecting opening of 25 cm from the surface level, and type "S" with collecting opening of 25 cm located 25 cm from the surface level in six collecting points in two of the visits (fields a and d ), and sand traps of the type "T" with the collecting opening of 50 cm from the surface level in the other field trips (fields "b" and "c"). A set of records was also collected by using a portable meteorological station complemented with information such as frequency and intensity of winds, precipitation and relative air humidity in the region, from the Estação Meteorológica de Natal , located 12 km from the study area. The sediments collected were treated and the data obtained permitted calculating the ratio of sediment transport. In September, the sedimentation ratio varied from 0.01 to 11.39 kg.m-1.h-1 and in December this ratio varied from 0.33 to 1.30 kg.m-1.h-1 in the type T collectors. In type I collectors they ranged from 0.01 to 11.39 kg.m-1.h-1, while the same parameters varied from 0.01 to 0.73 kg.m-1.h-1 in type S collector. Based on the statistical analysis done, we concluded that the sediment transport increased proportionally to the wind speed 25 cm from the surface. However, this is not true above 25 cm from the surface. The transport of sediments is more intense near the surface where sedimentation ratios greater than 10 kg.m-1.h-1 were found, whilst a maximum value of 3 kg.m-1.h-1 was observed 25 cm below the surface. The volume of sediments collected increases with the increasing wind speed at the surface level, whereas this relationship is opposed far away from that surface

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we present the methodological procedures involved in the digital imaging in mesoscale of a block of travertines rock of quaternary age, originating from the city of Acquasanta, located in the Apennines, Italy. This rocky block, called T-Block, was stored in the courtyard of the Laboratório Experimental Petróleo "Kelsen Valente" (LabPetro), of Universidade Estadual de Campinas (UNICAMP), so that from it were performed Scientific studies, mainly for research groups universities and research centers working in brazilian areas of reservoir characterization and 3D digital imaging. The purpose of this work is the development of a Model Solid Digital, from the use of non-invasive techniques of digital 3D imaging of internal and external surfaces of the T-Block. For the imaging of the external surfaces technology has been used LIDAR (Light Detection and Range) and the imaging surface Interior was done using Ground Penetrating Radar (GPR), moreover, profiles were obtained with a Gamma Ray Gamae-spectômetro laptop. The goal of 3D digital imaging involved the identification and parameterization of surface geological and sedimentary facies that could represent heterogeneities depositional mesoscale, based on study of a block rocky with dimensions of approximately 1.60 m x 1.60 m x 2.70 m. The data acquired by means of terrestrial laser scanner made available georeferenced spatial information of the surface of the block (X, Y, Z), and varying the intensity values of the return laser beam and high resolution RGB data (3 mm x 3 mm), total points acquired 28,505,106. This information was used as an aid in the interpretation of radargrams and are ready to be displayed in rooms virtual reality. With the GPR was obtained 15 profiles of 2.3 m and 2 3D grids, each with 24 sections horizontal of 1.3 and 14 m vertical sections of 2.3 m, both the Antenna 900 MHz to about 2600 MHz antenna. Finally, the use of GPR associated with Laser Scanner enabled the identification and 3D mapping of 3 different radarfácies which were correlated with three sedimentary facies as had been defined at the outset. The 6 profiles showed gamma a low amplitude variation in the values of radioactivity. This is likely due to the fact of the sedimentary layers profiled have the same mineralogical composition, being composed by carbonate sediments, with no clay in siliciclastic pellitic layers or other mineral carrier elements radioactive

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The motion capture is a main tool for quantitative motion analyses. Since the XIX century, several motion caption systems have been developed for biomechanics study, animations, games and movies. The biomechanics and kinesiology involves and depends on knowledge from distinct fields, the engineering and health sciences. A precise human motion analysis requires knowledge from both fields. It is necessary then the use of didactics tools and methods for research and teaching for learning aid. The devices for analysis and motion capture currently that are found on the market and on educational institutes presents difficulties for didactical practice, which are the difficulty of transportation, high cost and limited freedom for the user towards the data acquisition. Therefore, the motion analysis is qualitatively performed or is quantitatively performed in highly complex laboratories. Based is these problems, this work presents the development of a motion capture system for didactic use hence a cheap, light, portable and easily used device with a free software. This design includes the selection of the device, the software development for that and tests. The developed system uses the device Kinect, from Microsoft, for its low cost, low weight, portability and easy use, and delivery tree-dimensional data with only one peripheral device. The proposed programs use the hardware to make motion captures, store them, reproduce them, process the motion data and graphically presents the data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The high-intensity interval exercise has been described as an option for increasing physical activity and its use also being suggested in the therapeutic management of many conditions such as diabetes mellitus and heart failure. However, the knowledge of its physiological effects and parameters that can assure greater safety for interval exercise prescription; especially its effect on short- and medium-term (24 hours after exercise) exercise recovery, need to be clarified. This study objective was to evaluate the effect of continuous and interval aerobic exercise on the cardiac autonomic control immediate and medium term (24 hours), by assessing heart rate variability (HRV). The present study is a randomized crossover clinical trial in which healthy young individuals with low level of physical activity had the VFC 24 hours measured by a heart rate sensor and portable accelerometer (3D eMotion HRV, Kuopio, Finland) before and after continuous aerobic exercise (60-70% HR max, 21 min.) and interval exercise (cycle 1 min. 80-90% HR max, 2 min. at 50-60% HR max, duration 21 min.). HRV was measured in the time and frequency domain and the sympathovagal balance determined by the ratio LF / HF. Nonlinear evaluation was calculated by Shannon entropy. The data demonstrated delayed heart rate recovery immediate after exercise and lower HR after 24 hours compared to pre intervention values, especially in the interval exercise group. There was a tendency to higher predominance and representatives index values of sympathetic stimulation during the day in interval exercise group; however, without statistical significance. The study results help to clarify the effects of interval exercise on the 24 hours following interval exercise, setting parameters for prescription and for further evaluation of groups with metabolic and cardiovascular diseases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BRUNO, S. S. ; SOUSA, M. B. C. . Modulação pela progesterona da sensibilidade dolorosa a estímulos mecânicos e isquêmicos em mulheres saudáveis e jovens. RBGO. Revista Brasileira de Ginecologia e Obstetrícia , v. 30, p. 306-311, 2008

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aims to compare the thermal performance of tiles made from recycled material (waste packaging cardboard with aluminized film) with the tiles of fiber and bitumen, fiber cement and red ceramic with the aim of verifying the suitability of tile to be used in hot and humid climate of low latitude. The samples were selected according to the availability from Natal - RN market, as they are sold to the consumers. The methodology was based on studies that used experimental apparatus composed of thermal chambers heated by banks of incandescent bulbs, to analyze the thermal performance of materials. The tiles in the study were submitted to analysis of thermal performance, thermophysical properties and absorptance, using chambers of thermal performance, measuring the thermophysical properties and portable spectrometer, respectively. Comparative analysis of thermal performance between two samples of the recycled material with dimple sizes and different amounts of aluminum were made, in order to verify, if these characteristics had some interference on the thermal performance of them; the results showed no significant performance differences between the samples. The data obtained in chambers of thermal performance and confirmed by statistical analysis, showed, that the tile of recycled material have similar thermal performance to the tile of fiber cement. In addition to these tests was carried out the automatic monitoring of a building covered with tiles of recycled material, to verify its thermal performance in a real situation. The results showed that recycled shingles must be used with technical criteria similar to those used for fiber cement tiles, with regard to the heat gain into the building. Within these criteria should be taken into account local characteristics, especially in regions with hot and humid climate, and its use must be associated, according to the literature, to elements of thermal insulation and use of passive techniques such as vented attics, ceilings and right foot higher

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Efforts in research and development of new technologies to reduce emission levels of pollutant gases in the atmosphere has intensified in the last decades. In this context, it can be highlighted the modern systems of electronic engine management, new automotive catalysts and the use of renewable fuels which contributes to reduce the environmental impact. The purpose of this study was a comparative analysis of gas emissions from a automotive vehicle, operating with different fuels: natural gas, AEHC or gasoline. To execute the experimental tests, a flex vehicle was installed on a chassis dynamometer equipped with a gas analyzer and other complementary accessories according to the standard guidelines of emission and security procedures. Tests were performed according to NBR 6601 and NBR 7024, which define the urban and road driving cycle, respectively. Besides the analysis of exhaust gases in the discharge tube, before and after the catalyst, using the suction probe of the gas analyzer to simulate the vehicle in urban and road traffic, were performed tests of fuel characterization. Final results were conclusive in indicating leaded gasoline as the fuel which most contributed with pollutant emissions in atmosphere and the usual gasoline being the fuel which less contributed with pollutant emissions in atmosphere