33 resultados para Carvão do lodo de esgoto doméstico
Resumo:
In wastewater treatment, activated sludge systems have been a technology widely applied as secondary treatment. During this step, which has a strong biological aspect, it is necessary to introduce oxygen supply for the maintenance of metabolic activity of the bacteria through the aerators. Aeration devices are responsible for most of the energy consumption in this stage. In this background, the influence of three aeration intensities (atmospheric air flow 3.5, 7.0 and 10.5 L.min-1) and the concentration of dissolved oxygen (DO) on the dimension of activated sludge flocs as well as on the efficiency of organic matter removal were assessed using a traditional activated sludge system which was fed with synthetic domestic wastewater. Samples were taken weekly from the three units that make up the system feed, aeration and storage tank in order to verify the Chemical Oxygen Demand (COD). It was established the process efficiency through a comparison between the initial and final COD. Besides the parameters already mentioned, this monitoring work on activated sludge batch system was also observed by Mixed Liquor Suspend Solids (MLSS), Volatile Suspend Solids (VSS), pH and temperature measures. The results have showed a maximum removal efficiency around 75% in the first aeration sequence and approximately 85% for the second and third one. For the first aeration, the DO concentration remained higher than 3.0 mg.L-1 and a diameter range from 10 to 60 μm was observed. In the second e third sequence, the DO concentration remained higher than 4.0 mg.L-1 with a diameter range of 10 until 200 μm. Although the sequence 1 and 2 have presented similar performances for organic matter removal, the sequence 2 promoted a regular floc size distribution and with lower values of Sludge Volumetric Index (SVI) meaning a better flocculating ability. In addition, the results reaffirmed what the literature has reported: higher DO concentrations produce flocs with greater dimensions
Resumo:
Stabilization ponds are an effective sewage treatment alternative for the climatic conditions prevailing in Brazil. In the present work, a primary facultative pond was studied, in the city of Natal, Rio Grande do Norte, Northeast Brazil. The aim of this study was to evaluate the sedimentation dynamics in the facultative pond. The pond was divided in three section or zones along its length starting from the inlet end namely A1, A2 and A3. The research was accomplished in three phases. In the first the mapping of the sludge layer was done, sludge core samples were also collected for analysis for total, fixed and volatile solids and the depth of the sludge layer was determined using a portable echo sounder. In the second solids sedimentation rates were measured using traps placed in the inlet and outlet zones and in the third phase resuspension sludge was evaluate using a tracer. The amount accumulated sludge since the start operation was 13.583 m3. The sedimentation constant averages changed between 0.93 to 2.94 and 3.90 to 5.80 for the depths of 0.5 and 1.0 m respectively. The relationship between volatile and fixed solids (SV/SF) increased along the pond. The removal efficiencies were 52.12%, 36.09%, and 37.50% for BOD, COD and SS, respectively. The sludge accumulation model proposed had a good adjustment with 0.17 m3/hab.year rate. The results presented here demonstrated that the wind had a direct influence on the sedimentation of solids in this pond affecting the efficiency and sludge accumulation
Resumo:
In the urban areas of the cities a larger problem of destiny of effluents of the treatment stations is verified due to the junction of the sewages in great volumes. This way the hidroponic cultive becomes important, for your intensive characteristic, as alternative of reuse. This work presents as objective the improvement of the relation hidric-nutritious of the hidroponic cultive of green forage (FVH) using treaty sewage. The production of forage was with corn (Zea mays L.), using double hybrid AG1051, in the experimental field of the Federal University of Rio Grande do Norte (UFRN), in the city of Natal-RN-Brazil. The treated effluent essentially domestic had origin of anaerobic reactor, type decant-digester of two cameras in series followed by anaerobic filters drowned. The hidroponic experimental system was composed of 08 stonemasons, with limited contours for masonry of drained ceramic brick, measuring each one 2,5 meters in length for 1,0 meter of width, with inclination of 4% (m/m) in the longitudinal sense, leveled carefully, in way to not to allow preferential roads in the flow. These dimensions, the useful area of Isow was of 2 square meters. The stonemasons of cultive were waterproof (found and lateral) with plastic canvas of 200 micres of thickness, in the white color. Controlled the entrance and exit of the effluente in the stonemasons, with cycles of 12,68 minutes, it being water of 1,18 minutes. The treatments were constituted of: T1 - 24 hours/day under it waters with flow of 2 L/min; T2 - 12 hours/day under waters with flow of 4 L/min; T3 - 12 hours/day under waters with flow of 2 L/min; and T4 - 16 hours/day under waters with flow of 3 L/min. There were evaluations of the evapotranspirometric demand, of hidroponic system affluent and effluent seeking to characterize and to monitor physical-chemical parameters as: pH, temperature, Electric Conductivity and Fecal Coliforms. This last one was analyzed to the 11 days after isow (DAS) and to the 14 DAS. The others were analyzed daily. I sow it was accomplished in the dates of February 21, 2007, first experiment, and April 10, 2007, second experiment. The density of Isow was of 2 kg of seeds, germinated before 48 hours, for square meter of stonemason. The statistic delineament was it casual entirely with two repetitions, in two experiments. It was applied Tukey test of average to five percent of probability. The cultivation cycle was of 14 DAS with evapotranspirometric demand maximum, reached by T1, of 67,44 mm/day. The analyzed parameters, as mass of green matter - Kg, productivity-Kg/m2 and reason of production of seed FVH/Kg used in Isow, the best result was presented by T1, obtaining value of up to 19,01 Kg/m2 of cultive. Without significant difference, the T4 presented greats values with 16 hours under cycle of water. The Treatments 2 and 3 with 12 hours under cycle of water, they obtained inferior results to the other Treatments. As treatment system, came efficient in the reduction of the salinity. T1 obtained reduction medium maxim of 62,5%, to the 7 DAS, in the amount of salts that enter in the system in they are absorbed in the cultivation. The cultivation FVH acted reducing the microbiologic load. Significant percentile of reduction they were reached, with up to 90,23% of reduction of Units of Colonies (UFC), constituting, like this, the Hidroponic System as good alternative of treatment of effluents of Reactors of high Efficiency
Resumo:
The struvite precipitation in wastewater treatments plants offer advantages to obtaining a economically viable product, containing phosphorus, nitrogen and magnesium, in a bioavailable conditions to plants. The precipitation process requires ideal conditions, but all of these aspects are difficult to obtain and may result in resistance to collect crystals during the sedimentation process. Therefore, instead find the best conditions for precipitation, we propose the dissolved air flotation as another method to retrieve the crystals. The application of dissolved air flotation method to promote separation of struvite crystals from sewage supernatant, was evaluated in a precipitation-flotation reactor (flotatest) and were compared with the precipitation-sedimentation assays (jar test). Finally, were observed that the dissolved air flotation process was as feasible as sedimentation to promote struvite crystals separation, and the pH are the most influencer factor for an efficient separation
Resumo:
In the state of Rio Grande do Norte (RN), Brazil, there are about 80 sewage treatment systems being the predominant technology waste stabilization ponds. The Baldo s WWTP , due to its location and low availability of area, was designed as a hybrid conventional system (UASB reactor followed by activated sludge with biodiscs) at a tertiary level, being the most advanced WWTP in the State and also with the larger treatment capacity (1620 m3/h) .The paper presents the results of its performance based on samples collections from May to December 2012. Composite samples of the effluent of the grit chamber, UASB reactors, anoxic chambers, aeration tanks and treated effluent were collected weekly, every 4 hours for 24 hours. The results showed that the WWTP effluent presented adequate ranges of temperatures, pH and DO, however removal efficiencies of BOD and TSS were below the predicted by design. The UASB reactors also showed removals of BOD and TSS less than expected, due to the accumulation of sludge in the reactors, which eventually, was washed out in the effluent. The nitrification process was not satisfactory mainly due to problems in the oxygen distribution in the aeration tanks. The removal of ammonia and TKN were high, probably by the assimilation process
Resumo:
This paper evaluate the performance of a Wastewater Treatment Plant (WWTP) in sequential batch activated sludge modality with tertiary treatment step, located in high temperature region. It also presents the analysis of organic matter’s removal and the evaluation of sludge sedimentation conditions through reactors in bench scale, fed with different substrate’s and biomass’ concentrations, from the WWTP in study. The results showed high efficiency and stability of the treatment process using Sequential Batch Reactors for domestic sewage, even with sudden changes of organic and hydraulic load, reaching more than 90% of efficiency in the removal of biodegradable organic matter. The removal of organic matter and sedimentation tests in bench reactors showed the good performance in respect of the organic matter’s removal, however, the high concentration of micro-organism results in a lower sludge sedimentation rate, which can compromise the quality of the final effluent. The relation Food/Microorganism in the conditions of the WWTP’s current operation showed a value of 0.06 gCOD/gVSS.d. and zonal sedimentation velocity of 0.59 m/h, the great ratio of the concentration of the substrate by biomass concentration, which obtained the maximum operational efficiency, showed a value of 0.09 gCOD/gVSS.d. and zonal sedimentation velocity of 1.4 m/h.
Resumo:
This paper evaluate the performance of a Wastewater Treatment Plant (WWTP) in sequential batch activated sludge modality with tertiary treatment step, located in high temperature region. It also presents the analysis of organic matter’s removal and the evaluation of sludge sedimentation conditions through reactors in bench scale, fed with different substrate’s and biomass’ concentrations, from the WWTP in study. The results showed high efficiency and stability of the treatment process using Sequential Batch Reactors for domestic sewage, even with sudden changes of organic and hydraulic load, reaching more than 90% of efficiency in the removal of biodegradable organic matter. The removal of organic matter and sedimentation tests in bench reactors showed the good performance in respect of the organic matter’s removal, however, the high concentration of micro-organism results in a lower sludge sedimentation rate, which can compromise the quality of the final effluent. The relation Food/Microorganism in the conditions of the WWTP’s current operation showed a value of 0.06 gCOD/gVSS.d. and zonal sedimentation velocity of 0.59 m/h, the great ratio of the concentration of the substrate by biomass concentration, which obtained the maximum operational efficiency, showed a value of 0.09 gCOD/gVSS.d. and zonal sedimentation velocity of 1.4 m/h.
Resumo:
The WTP produce many kinds of residue on your treatment stages, but the sludge is the more problematic from the final disposition point view. The actual rate of residue production deriving from technological evolution and the crescent population needs prevents the subtle equilibrium generation between consumption and recycling/reuse, creating problems of pollution resulting from inappropriate management of residues. Thus, is necessary achieve a new equilibrium between the grow from raw materials and energy and the residue generation. This equilibrium should be achieved by technical and economic feasibility of environmental supported models through recycling and reuse. The red ceramic industry stand out in residue absorption question as raw material due their clay mass heterogeneity, constituted by clay minerals and non-clay minerals with wide mineralogical variation, allowing residue inclusion which act like plastic or non-plastic materials, contributing to retain heavy metals contained in residues in the vitreous mass formed during the burning of the ceramic bodies. This work propose the study of the influence of incorporation of 25 wt.% sludge from wastewater treatment plant, according preliminary results, in the mass to produce ceramic bodies. The raw materials was characterized through chemical composition analyses by XRF, mineralogical analyses by XRD, thermal analyses by TG and DTA, Atterberg limits and thermodilatometry. Subsequently was composed the mass with 75 wt.% of clay and 25 wt.% of dried wastewater sludge from UFRN WWTP. Samples with 6,0 x 2,0 x 0,5 cm was produced with unidirectional compacting under pressure of 20MPa and burned in temperatures between 950 and 1,200ºC. After fired, the ceramic bodies have been submitted to physical and mechanical analyses through the measure of firing shrinkage, water absorption, density, apparent porosity and flexural strength; crystallographic analyses through XRD and microstructure analyses by SEM. The technological properties obtained was satisfactory to production of roof tiles with 25 wt.% at 1,200 ºC, but the production of others products at lower temperatures was not feasible
Resumo:
In this work we thought about the social use of the domestic space and, specifically, the space destined to the preparation of food. The kitchen is a creative space of social relationships. There the families exchange daily interaction with the neighbors, in a collective of the space reserved to the making of food. Our empiric research was in the Mutamba da Caieira community, located in the county of Assu (RN). The data was collected through the etnographic method aided by the photographic resources. In the discussion, we delimitated at the house three types of kitchens: one reserved to the family, another kitchen in the terrace and yet another kitchen in the yard. They are kitchens that link amongst themselves with activities and differentiated temporalities. In the daily social exchange, the kitchen imposes itself as a social space through the conditions that it offers for the production of the foods, the circulation of domestic objects, the communication of knowledge around the cookery, operating a group of symbolic and ritual actions combined with appropriate techniques for the transformation of the foods. The study reveals that the domestic chores accomplished amon relatives and friends form webs of intracommunitary relationships in the use of the three kitchens, and that the social network is updated in a singular moment that usually happens in the community, the Game of Pacará
Resumo:
I propose with this paper a reflection on the experiences contained in the creation of the body- in-art (FERRACINI, 2006a, b) that originated the show Rosmaninhos... This process was developed within the coletivo UZUME teatro from João Pessoa PB, through recreations and resignifications of the corporeity and physicality contained in the steps, loas, aboios, songs and choreography observed in the manners that Mestre Zequinha plays in his group of Cavalo Marinho (Sea Horse), resident in the city of Bayeux - PB, and starting from the appropriation of the text Hamlet of William Shakespeare. The body-in-art is understood in this work as a vectorial body that dilates its daily functionality, recognizing a potential learning area capable to generate creative escape lines that destabilize the "subject centered in an individuality and identity" (FOUCAULT apud FERRACINI, 2006b, p.14), being open to the differentiation of itself, indicating the possible existence of an itself-other and of the exchange-in-art space. This process of construction of the body-in-art based on Master Zequinha s ways of playing the Cavalo Marinho was methodically guided by the appropriation of the coletivo UZUME teatro of the stages of Observation, Codification and Theatricalization contained in the technique of corporal mimeses proposed by the LUME Teatro (Campinas - SP). That use resulted in two phases: Active Observation and Composition of the body-in-art. Through the repetition of these aesthetic matrixes of the Cavalo Marinho, the actors discovered actions that when, codified and organized, can configure their body-in-art, which created a vectorial exchange-in-art space to what was found in the Cavalo Marinho party. This search proposed the means of potentiating the actors' work when it comes to a preparation that allowed to dilate the scenic presence and stimulated the production of actions, which culminated in the mounting of the show Rosmaninhos...
Resumo:
This work demonstrates important aspects of domestic work performed by adolescents between 16 and 18 years in residential spaces. This is to highlight the process of naturalization of invisibility, their source of insecurity and social exclusion, in view of the strong personal relationship of domination. Pointing out the relations of pseudo-affection that can obscure the exploitation of domestic labor. Highlight a preliminary discussion on the composition of social relations embedded in the context of domestic work, with emphasis on reflection on the condition of subordination of young domestic workers as a result of a process of socialization consists of relations of domination - gender and social class, resulting in formation of social identity-forming negative stigma. This paper results from a survey of the work of young maids, held in the city of Aracaju, whose main objective was to understand how they operated the differences and inequalities in the relations of domestic based, including information on adolescents' own. Fieldwork was conducted from August 2009 to January 2010 and data collection techniques were used oral history / life history, questionnaires and use of semi-structured interviews, as well as secondary data from PNAD / IBGE which formed the basis of comparative national situation and local context. It emphasizes the links of domestic work involving teenagers question the lifestyles of working class who are confronted by the various "systems" for each home, which leads to the development of adaptation strategies that make possible the coexistence of a stranger the house at the other. It focuses on how the work goes into their lives in terms of socialization offered by working families to their children's, and as this class habitus is adequate for the job market in domestic employment through a socialization process that sometimes opposes and now reinforces the practices and values seized in family socialization
Resumo:
This research this based on the seminar on Use of Natural Fluids in Refrigeration and Air-Conditioning Systems conducted in 2007 in Sao Paulo. The event was inserted in the National Plan for Elimination of CFCs, coordinated by the Ministry of Environment and implemented by the United Nations Development Programme (UNDP). The objective of this research is analyze the performance of the hydrocarbons application as zeotropic mixtures in domestic refrigerator and validate the application of technical standards for pull down and cycling (on-off) tests to the mixture R290/R600a (50:50) in domestic refrigerator. It was first developed an computational analysis of R290/R600a (50:50) compared to R134a and other mass fractions of the hydrocarbons mixtures in the standard ASHRAE refrigeration cycle in order to compare the operational characteristics and thermodynamic properties of fluids based on the software REFPROP 6.0. The characteristics of the Lorenz cycle is presented as an application directed to zeotropic mixtures. Standardized pull down and cycling (on-off) tests were conducted to evaluate the performance of the hydrocarbons mixture R290/R600a (50:50) as a drop-in alternative to R134a in domestic refrigerator of 219 L. The results showed that the use of R290/R600a (50:50) with a charge of refrigerant reduced at 53% compared to R134a presents reduced energy performance than R134a. The COP obtained with hydrocarbon mixture was about 13% lower compared to R134a. Pull down times in the refrigerator compartments for fluids analyzed were quite close, having been found a 4,7% reduction in pull down time for the R290/R600a compared to R134a, in the freezer compartment. The data indicated a higher consumption of electric current from the refrigerator when operating with the R290/R600a. The values were higher than about 3% compared to R134a. The charge of 40 g of R290/R600a proved very low for the equipment analyzed
Resumo:
The technology of anaerobic reactors for sanitary wastewater treatment has been extensively developed in Brazil, and today it is practically consolidated. They present several advantages, such as low construction and operating costs, and low sludge production, the anaerobic reactors are an attractive alternative to minimize problematic lack of basic sanitation in urban areas, and also of the rural areas. The anaerobic filters have been widely used in Brazil. It produces an effluent with low concentration of organic matter and solids suspended, besides conserving the nutrients, therefore, it is good for use in irrigation, but the practice must be associated with knowledge of the pathogens presence. The main objective of this study was to evaluate the efficiency of anaerobic filters in removal faecal coliforms and helminth eggs, and to verify if the effluent can be used for agricultural purposes, according to the World Organization of Health (WHO, 1989). The protocol used to enumerate helminths eggs was the modified Bailenger method, (Ayres and Mara, 1996) recommended by WHO for evaluation of raw effluent and treated effluent. The membrane filtration method was utilized to determine the concentrations of faecal coliforms. Three different systems of sewer treatment composed by anaerobic filters were analyzed. The results, in a general analysis, showed that all the researched systems reached a larger removal than 93% to helminth eggs, resulting in an effluent with smaller average than 1 egg/L. One of these systems, Sistema RN, reached a larger removal than 99%, confirming the good performance of the anaerobic filters in removal helminths eggs. Even with low concentrations of eggs in the influent, the filters were capable to remove this parameter efficiently. About faecal coliforms, it was observed for all the researched systems an effluent with 106 CFU/100mL. The high concentrations to faecal coliforms in the effluent just allow reuse for restricted irrigation, in agreement with the guidelines of WHO. Although the researched systems have not removed faecal coliforms efficiently, the results indicated a good efficiency of the anaerobic filters in removal helminth eggs
Resumo:
Only 32% of the population of Natal is attended by sewage, while the remaining population use pits and septic tanks. The characterization of the contents of septic tanks and pits contributes to the performance of such system and may guide the decision on treatment of these contents. The main of this research is to characterize the contents of interior residential pits and septic tanks in the greater Natal, with the following specific goals: to develop and manufacture a sampler capable of collecting a representative sample of the entire column (the surface scum, the clarified liquid and sludge bottom); to compare the contents of the tanks with the pits; to compare the contents of the septage from vacuum trucks; to relate the composition content with socioeconomic characteristics of households; to compare the content in both chambers of the septic tanks in series; to assess the situation of the content before and six months after the cleanness; and ultimately propose a pilot scale plant for treatment of septage. Once the sampler was developed, samples were collected within 14 septic tanks and 10 pits in many districts of Natal. Medians of the 24 systems were obtained: temperature, pH, conductivity, oil and grease, total solids, total suspended solids and sediments of 28.0 °C, 6.95; 882 mS/cm, 75.2 mg/L; 10,169 mg/L, 6,509 mg/L and 175 mL/L respectively; 111.0 mgN/L for ammonia, 130.5 mgN/ L for organic nitrogen, 0.2 mgN/L for nitrite, 0.4 mg/L for nitrate; 8935 mgO2/L for COD, 29.2 mgP/L for total phosphorus, thermotolerant coliforms from 9.95 E +06 CFU/100mL helminth eggs and 9.2 eggs/L with a maximum concentration of 688 eggs/L and minimum of 0 eggs/L. Medians of organic nitrogen and TKN were significantly different between groups of tanks and pits. The systems with cleanness gap from 11 and 20 years presented the higher concentrations for most variables. The effluent from the toilets and bathrooms participate more effectively in contributing fractions of solids, alkalinity, nitrogen, COD, total phosphorus, thermotolerant coliforms and helminth eggs. The systems used by socioeconomics class with income from R$ 3,700.00 to R$ 7,600.00, presented higher concentrations for COD, nitrogen, solids and helminth eggs. The first of the two chambers had always presented higher concentrations over the second compartment. The analysis of variance for most variables, showed that the values of septic tanks, pits and septage from vacuum trucks belong to the same group. In the samples taken after cleanness, the median of pH and temperature increased, while alkalinity, COD, organic nitrogen, total phosphorus, ammonia and helminth eggs decreased. The oils and greases and thermotolerant coliforms had slightly varied due to the continuous release of sewage into the systems that maintained their steady state concentrations.
Resumo:
The improper disposal of nitrogen in receiving water courses causes problems such as toxicity to living beings through the consumption of oxygen to meet the nitrogen demand, eutrophication and nitrate contamination of aquifers. For this reason it is often necessary to be carried out complementary treatment of wastewater to eliminate or reduce the concentration of this compound in the wastewater. The objective of this study is to evaluate the biological removal of nitrogen compounds using submerged aerated and anoxic filters as post-treatment of an anaerobic system, with low cost and innovative technology, which in previous studies has shown high removal efficiency of organic matter and great potential biological nitrogen compounds removal. The simple design with perforated hoses for air distribution and filling with plastic parts proved to be very efficient in relation to organic matter removal and nitrification. The system presented, in the best stage, efficiency in converting ammonia to nitrate by 71%, and produced a final effluent concentration below 10 mg / L of NH3-N. In addition, carbon concentration was removed by 77%, producing final effluent with 24 mg/L COD. However, denitrification in anoxic filter was not effective even with the addition of an external carbon source. There was a reduction of up to 56% of nitrogen caused by the process of simultaneous nitrification and denitrification (SND). The high voids space presented by this type of support material coupled with direct aeration of the sludge, allows the respiration of biomass retained between the endogenous phase, increased cell retention time and sludge retention capacity, producing a final effluent with turbidity less than 5 UT and total suspended solids around 5.0 mg/L