21 resultados para Biscayne aquifer


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study area is within the Pirangi River Basin, eastern sector of Rio Grande do Norte state, where is located of the Parnamirim city. It has an area of approximately 370 km². Urbanization has developed much fast without an appropriate infrastructure, mainly by the lack of sewage systems, with risks of contamination of groundwater that may cause serious damage to the health of the population. The Barreiras Aquifer System groundwater in the area represents the main source of water supply for urban and rural populations. The use of groundwater occurs without adequate planning and therefore, important recharge areas are being occupied. This study was conducted to quantify the use and evaluation of the potential of groundwater, in order to increase good water quality supply and lower risks of being affected by polluting activities. With these objectives, the following activities were carried out: 268 points of water have been registered; characterization of the lithological, thickness and hydrogeological structure of the Barreiras aquifer, based on the correlation of well logs; and evaluation of hydrodynamic parameters of the aquifer, from the interpretation of results well pumping tests. It was found that the saturated thickness increases from west to east towards the sea, with values ranging from 15,47-56,5 m with an average of 32,45 m. The hydrodynamic parameters using Cooper-Jacob method were: average transmissivity of 5,9x10-3 m²/s and average hydraulic conductivity 2,82x10-4 m/s. The effective porosity is of 15%, obtained by applying Biecinski equation. The potentiometric map shows the main direction of groundwater flow, from west to east, and identifies the recharge areas corresponding to the region of the tablelands of the "Barreiras". The river valleys refer to the discharge areas of the aquifer system. The Recharge was estimated at 253 mm/year, which corresponds to the 16.4% rate of infiltration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study area is within the Pirangi River Basin, eastern sector of Rio Grande do Norte state, where is located of the Parnamirim city. It has an area of approximately 370 km². Urbanization has developed much fast without an appropriate infrastructure, mainly by the lack of sewage systems, with risks of contamination of groundwater that may cause serious damage to the health of the population. The Barreiras Aquifer System groundwater in the area represents the main source of water supply for urban and rural populations. The use of groundwater occurs without adequate planning and therefore, important recharge areas are being occupied. This study was conducted to quantify the use and evaluation of the potential of groundwater, in order to increase good water quality supply and lower risks of being affected by polluting activities. With these objectives, the following activities were carried out: 268 points of water have been registered; characterization of the lithological, thickness and hydrogeological structure of the Barreiras aquifer, based on the correlation of well logs; and evaluation of hydrodynamic parameters of the aquifer, from the interpretation of results well pumping tests. It was found that the saturated thickness increases from west to east towards the sea, with values ranging from 15,47-56,5 m with an average of 32,45 m. The hydrodynamic parameters using Cooper-Jacob method were: average transmissivity of 5,9x10-3 m²/s and average hydraulic conductivity 2,82x10-4 m/s. The effective porosity is of 15%, obtained by applying Biecinski equation. The potentiometric map shows the main direction of groundwater flow, from west to east, and identifies the recharge areas corresponding to the region of the tablelands of the "Barreiras". The river valleys refer to the discharge areas of the aquifer system. The Recharge was estimated at 253 mm/year, which corresponds to the 16.4% rate of infiltration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of chemical fertilization in arable perimeters provides increased productivity, though it can eventually lead to a qualitative depreciation of groundwater sources, especially if such sources are unconfined in nature. In this context, this thesis presents results from an analysis of the level of natural protection of the Barreiras Aquifer in an area located on the eastern coast of the Rio Grande do Norte State - Brazil. Such an aquifer is clastic in nature and has an unconfined hydraulic character, which clearly makes it susceptible to contamination from surface ground loads with contaminants associated with the leaching of excess fertilizers not absorbed by ground vegetation. The methodology used was based on the use of hydro-geophysical data, particularly inverse models of vertical electrical soundings (VES) and information from well profiles, allowing the acquisition of longitudinal conductance cartographies (S), data in mili-Siemens (mS), and the vulnerability of the aquifer. Such maps were prepared with emphasis to the unsaturated overlying zone, highlighting in particular its thickness and occurrence of clay lithologies. Thus, the longitudinal conductance and aquifer vulnerability reveal areas more susceptible to contamination in the northeast and east-central sections of the study area, with values equal to or less than 10mS and greater than or equal to 0,50, respectively. On the other hand, the southwestern section proved to be less susceptible to contamination, whose longitudinal conductance and vulnerability indices are greater than or equal to 30mS and less than or equal to 0,40, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of chemical fertilization in arable perimeters provides increased productivity, though it can eventually lead to a qualitative depreciation of groundwater sources, especially if such sources are unconfined in nature. In this context, this thesis presents results from an analysis of the level of natural protection of the Barreiras Aquifer in an area located on the eastern coast of the Rio Grande do Norte State - Brazil. Such an aquifer is clastic in nature and has an unconfined hydraulic character, which clearly makes it susceptible to contamination from surface ground loads with contaminants associated with the leaching of excess fertilizers not absorbed by ground vegetation. The methodology used was based on the use of hydro-geophysical data, particularly inverse models of vertical electrical soundings (VES) and information from well profiles, allowing the acquisition of longitudinal conductance cartographies (S), data in mili-Siemens (mS), and the vulnerability of the aquifer. Such maps were prepared with emphasis to the unsaturated overlying zone, highlighting in particular its thickness and occurrence of clay lithologies. Thus, the longitudinal conductance and aquifer vulnerability reveal areas more susceptible to contamination in the northeast and east-central sections of the study area, with values equal to or less than 10mS and greater than or equal to 0,50, respectively. On the other hand, the southwestern section proved to be less susceptible to contamination, whose longitudinal conductance and vulnerability indices are greater than or equal to 30mS and less than or equal to 0,40, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electrical resistive heating (ERH) is a thermal method used to improve oil recovery. It can increase oil rate and oil recovery due to temperature increase caused by electrical current passage through oil zone. ERH has some advantage compared with well-known thermal methods such as continuous steam flood, presenting low-water production. This method can be applied to reservoirs with different characteristics and initial reservoir conditions. Commercial software was used to test several cases using a semi-synthetic homogeneous reservoir with some characteristics as found in northeast Brazilian basins. It was realized a sensitivity analysis of some reservoir parameters, such as: oil zone, aquifer presence, gas cap presence and oil saturation on oil recovery and energy consumption. Then it was tested several cases studying the electrical variables considered more important in the process, such as: voltage, electrical configurations and electrodes positions. Energy optimization by electrodes voltage levels changes and electrical settings modify the intensity and the electrical current distribution in oil zone and, consequently, their influences in reservoir temperature reached at some regions. Results show which reservoir parameters were significant in order to improve oil recovery and energy requirement in for each reservoir. Most significant parameters on oil recovery and electrical energy delivered were oil thickness, presence of aquifer, presence of gas cap, voltage, electrical configuration and electrodes positions. Factors such as: connate water, water salinity and relative permeability to water at irreducible oil saturation had low influence on oil recovery but had some influence in energy requirements. It was possible to optimize energy consumption and oil recovery by electrical variables. Energy requirements can decrease by changing electrodes voltages during the process. This application can be extended to heavy oil reservoirs of high depth, such as offshore fields, where nowadays it is not applicable any conventional thermal process such as steam flooding

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In Brazil and around the world, oil companies are looking for, and expected development of new technologies and processes that can increase the oil recovery factor in mature reservoirs, in a simple and inexpensive way. So, the latest research has developed a new process called Gas Assisted Gravity Drainage (GAGD) which was classified as a gas injection IOR. The process, which is undergoing pilot testing in the field, is being extensively studied through physical scale models and core-floods laboratory, due to high oil recoveries in relation to other gas injection IOR. This process consists of injecting gas at the top of a reservoir through horizontal or vertical injector wells and displacing the oil, taking advantage of natural gravity segregation of fluids, to a horizontal producer well placed at the bottom of the reservoir. To study this process it was modeled a homogeneous reservoir and a model of multi-component fluid with characteristics similar to light oil Brazilian fields through a compositional simulator, to optimize the operational parameters. The model of the process was simulated in GEM (CMG, 2009.10). The operational parameters studied were the gas injection rate, the type of gas injection, the location of the injector and production well. We also studied the presence of water drive in the process. The results showed that the maximum vertical spacing between the two wells, caused the maximum recovery of oil in GAGD. Also, it was found that the largest flow injection, it obtained the largest recovery factors. This parameter controls the speed of the front of the gas injected and determined if the gravitational force dominates or not the process in the recovery of oil. Natural gas had better performance than CO2 and that the presence of aquifer in the reservoir was less influential in the process. In economic analysis found that by injecting natural gas is obtained more economically beneficial than CO2