20 resultados para coliformes totais
Resumo:
The National School Nutrition Program is the oldest program in the country directed at food and nutrition safety. Its aims are to offer nutritional food as a supplement to students of public and philanthropic schools. Studying school nutrition transcends the investigation as a purely social program, given that it reaches the fields of public health, nutrition and food, using a wide variety of approaches. Thus, it is characterized by a multidisciplinary study, where the disciplines work side by side in distinct aspects of a single problem. Aim: This study aims to assess hygiene practices during the preparation of meat-based meals in public schools in the city of Natal, Brazil. Methods: A list was applied at 27 schools to identify the procedures of good food preparation practices. In addition, cooking and meal distribution temperature were measured and a microbiological analysis of the final preparation and of the water used in preparing it was performed. For microbiological analyses of the food, we analyzed coliforms at 45°C, coliforms at 35°C and Enterococcus, and for the water, we analyzed thermotolerant coliforms and total coliforms, using the methods recommended by APHA, 1995. Results: Most of the schools did not meet the required standards in all the variables related to good food preparation practices, except for the time spent preparing the meat, in which 89% were within the norm. Cooking temperature of the meals was within the standard; however, the temperature at distribution and the time spent dispensing the meals were inadequate. Of the 27 schools, 22 (81.5%) showed the presence of coliforms at 35° C in at least one meal sample and 18 (66.7%) had values above the recommended limit for coliforms at 45°C. The presence of E. coli was identified in 6.1% of the samples analyzed. The presence of Enterococcus was not found at any of the schools. With respect to the water, the North district of the city was the only one that did not meet the standards for the two indicators evaluated. The contamination found was not associated with the hygiene or food storage problems observed. Conclusions: The results show that the hygiene-sanitary conditions of meat-based public school meals were unsatisfactory, demonstrating the need for improvements in the production process to preserve the health of the student population. Multidisciplinarity: Researchers from the areas of food microbiology, nutrition, public health and statistics took part in this study, a decisive factor for characterizing the research as multidisciplinary
Resumo:
The urban drainage is one of the powers of environmental sanitation and its scope is the quantitative and qualitative aspects. In decision making of managers and the engineering aspects of design are almost always taken into account only the quantitative aspects. However, the waters of the runoff have the highest concentrations of pollutants at the beginning of precipitation. Thus, if the plot pollution removed, the remaining portion can be used for other purposes. This work has aimed to present the variation of water quality of two drainage basins in the city of Natal / RN-Brazil to support the implementation of drainage to consider the qualitative aspect, and identify potential for the use of water. The basins (M and C) are analyzed closed-type, are in the urban area, are predominantly residential occupation and its waters are used for detention ponds and infiltration. The samples were divided into three phases, the first two direct to final points in a basin and the third in traps distributed over the surface drainage. The parameters had been analyzed were pH, conductivity, dissolved oxygen, Color, Turbidity, COD, Ammonia, nitrite, nitrate, total phosphorus, orthophosphate, Sediments solids, total solids, chloride, sulfate, alkalinity, calcium, magnesium, sodium, potassium, Heavy Metals (Chromium, Cadmium, Lead, Zinc and Copper), Eschichia coli and total coliforms. The parameters studied showed high initial pollution load, events and located in different proportions, except nitrite, heavy metals and biological indicators. The size of the surface drainage and topographic its features influence the quality of water. However, the form of sampling is crucial in the qualitative study in the basin. The samplers developed at work, were generated economic and representative results. The urban rainwater presents organic faecal indicators. The runoff of water from both basins shows no risk of salinity and sodicity for use in irrigation, should be noted the content of chloride in the choice of method of irrigation
Análise da toxicidade no açude Riacho da Cachoeira, Lajes Pintadas (RN): um desafio interdisciplinar
Resumo:
Contamination by complex mixtures of various origins has been explored and studied for decades. Radon is a naturally occurring environmental contaminant that causes carcinogenic effects. These emissions can cause mutations in the lung tissue, which can initiate a carcinogenic process. Thus the dam Creek Falls, located in the municipality of Lajes Pintadas, was chosen for the development of this study, since cancer rates in the region reach 9% of the population annually, with this, the main objective of this study was evaluate the mutagenicity and toxicity of Riacho da Cachoeira damunder the influence of radon. The methodology ecotoxicological tests were performed with Ceriodaphinia dubia, as well as tests with Tradescantia pallida genotoxicologicos and Oreochromis niloticus. To understand how the population of Pintadas Slabs realizes the environment, we performed a study of environmental perception. The test results indicated that the reservoir water is toxic to test organimos exposed, found heavy metals, chloride, total and fecal coliforms as well as radon levels above the maximum allowed under Brazilian law. These results can be justified because it is so complex samples composed of different compounds that interact only with each other or causing synergistic effects. It was concluded that the dam Creek Waterfall, is contaminated with radon, as well as heavy metals, coliforms and chloride, causing toxic effects to the natural community. Thus, further studies should be performed with the human population of the region, to verify that the high rates of cancer in the population of the municipality may be linked to the presence of natural radiation. Thus, it is expected that the competent bodies that administer the municipality of Lajes Pintadas take reasonable steps to minimize risks and ensure the health of the community that still makes use of the weir
Resumo:
Garanhuns City, in Pernambuco, undergoes a rapid, polluting and non-organized urban development affecting its freshwater springs around the urban environment. These sources are of great importance to the district as well as to the hydrographic basin of the Mundaú River. In this view, this paper aims at analyzing the socio-environmental problems resulting from the urban expansion surrounding the Garanhuns’ sources. The study considers the social and environmental dynamics and follows the theoretical contributions of socio-environmental geography proposed by Mendonça’s Urban Environmental System methodological and theoretical model (2004), as well as the conceptual values of Santos’ space theory (2002a). The data treatment included bibliographical and documental research, evaluation of environmental impact, and water analysis. It revealed that Garanhuns possesses many local environmental traits favoring the coming out of freshwater springs and that these sources have played an important role in the making and development of that village. The environmental impacts on freshwater springs, like Olho D’água, Bom Pastor, Vila Maria, Pau Amarelo and Pau Pombo have been evaluated through the environmental impact score IIAN. It put alight serious cases of socio-environmental impacts on the dynamics of the freshwater springs. In the period of April 2013 and April 2014, it monitored the superficial water quality expelled by the Pau Pombo, Pau Amarelo e Vila Maria water sources, and the analyses of the contents followed the determinations of the Environmental National Board, whose parameters are dissolved oxygen, biochemical demand of oxygen, nitrate, total coliforms, faecal coliforms, and electrical conductivity. The results recollected suggest the existence of organic pollution and deep alteration in the water coming out from the sources. In consequence, it seems important the putting out of measures destined to stop those impacts and guaranteeing protection and maintenance of the freshwater springs and their micro-basins.
Resumo:
Cinquenta amostras de camarão fresco e refrigerado (Litopenaeus vannamei) foram coletadas em diferentes pontos de comercialização na cidade de Natal RN. As amostras foram maceradas em um gral estéril e 25 gramas semeadas em 225mL de APA contendo 1% de NaCl e 25g em 225mL de CL incubadas a 35ºC - 24 horas. O crescimento em APA foi semeado em placas de Ágar TCBS, incubadas a 35ºC-24h para isolamento de Vibrio e Aeromonas. O crescimento do CL foi semeado em Agar EAM, para isolamento de coliformes. Dos 102 isolados, 91 (89,2%) pertenciam ao gênero Vibrio e 11 (10,8%) ao gênero Aeromonas, com predominância de V. cholerae não O1/não O139, V. alginolyticus, V. carchariae e V. parahaemolyticus K- e A. veronii biogrupo sobria , A. jandaei, A. schubertii, A. veronii biogrupo veronii e A. hydrophila. A menor eficiência entre os antimicrobianos foi da AMP (57,8% de resistência) seguida da AMK (29,4%) e TCY (21,6%). As 39 cepas de Vibrio e Aeromonas multirresistentes se distribuíram em 10 perfis distintos, sendo que um revelou cinco marcos (AMP, CHL, NIT, SXT e TCY) em um isolado de V. carchariae de camarão, adquirido em supermercados. O índice MAR, nas 39 cepas variou de 0,28 a 0,42, sugerindo que são de risco na transferência e difusão da resistência na cadeia alimentar. Após a cura plasmidial pelo tratamento com AO de 24 cepas multirresistentes e com resistência intermediária de víbrio e aeromonas escolhidas aleatoriamente, 13 perderam totalmente a resistência e 7 perderam parcialmente, sendo que o maior percentual de perda da resistência ocorreu nas cepas de V. cholerae não O1 e não O139 (6 cepas), se concentrando nos marcos de resistência a AMP (13), AMK (11), TCY(8) e CIP(3). Os resultados da conjugação realizada entre amostras de Vibrio xvi curadas e a E. coli K12C600 demonstraram que 78,5% das culturas de Vibrio testadas revelaram capacidade de transferência para o gene que confere resistência a AMP e 28,5% para a TCY. Dos coliformes, E. coli foi a mais frequente, seguida de Citrobacter spp, isoladas em 40,3% e 27,5% das amostras respectivamente. AMP foi o antimicrobiano menos eficaz, seguido de TCY. As 11 cepas multirresistentes se distribuíram em 9 perfis distintos, um deles constituído de cinco marcos (AMP, NIT, TCY, CHL, SXT), albergados em uma cepa de Klebsiella spp, oriunda de camarão adquirido em supermercado, similar ao resultado obtido em V. carchariae. Conclui-se que, os camarões marinhos frescos e refrigerados, comercializados em Natal-RN evidenciaram contaminação com coliformes, víbrios e aeromonas multirresistentes a antimicrobianos comumente utilizados na terapia médica e veterinária, e que, possivelmente, a transferência de genes de resistência entre bactérias se constitui um sério problema de saúde pública
Resumo:
The great diversity of the textile industries activities causes the formation of wastewaters with high complex characteristics during the productive process, according to the industrial process used. The principal aim of the present work is the characterization of the wastewater from the textile industry that process the indigo, located in the Industrial District of Natal-RN, to know the contaminante load of each stage of the process and the framing of the wastewater with the standards of act of receiving of the System of Treatment of Wastewater of the Industrial District of Natal-RN SITEL-DIN, operated for the Company of Waters and Sewers of the RN CAERN. It was analyzed the following properties and pollutants agents: temperature; pH; alcalinity; color; COD (Chemical Oxygen Demand); total and suspended solids; heavy metals, thermotolerants coliformes, turbidity, dissolved oxygen and electrical conductivity. As conclusion it is distinguished that the wastewater did not get resulted satisfactory, according to comparisons with other sources, in only three parameters: turbidity, dissolved oxygen and electrical conductivity, however none of these parameters is criteria of acts of receiving of the SITEL-DIN,therefore the wastewater if finds inside of normality. After the analysis of the obtained results it was verified that SITEL-DIN is indispensable for completing the wastewater treatment
Resumo:
Among the main challenges in the beer industrial production is the market supply at the lowest cost and high quality, in order to ensure the expectations of customers and. consumers The beer fermentation stage represents approximately 70% of the whole time necessary to its production, having a obligatoriness of strict process controls to avoid becoming bottleneck in beer production. This stage is responsible for the formation of a series of subproducts, which are responsible for the composition of aroma/bouquet existing in beer and some of these subproducts, if produced in larger quantities, they will confer unpleasant taste and odor to the final product. Among the subproducts formed during the fermentation stage, total vicinal diketones is the main component, since it is limiting for product transfusion to the subsequent steps, besides having a low perception threshold by the consumer and giving undesirable taste and odor. Due to the instability of main raw materials quality and also process controls during fermentation, the development of alternative forms of beer production without impacting on total fermentation time and final product quality is a great challenge to breweries. In this work, a prior acidification of the pasty yeast was carried out, utilizing for that phosphoric acid, food grade, reducing yeast pH of about 5.30 to 2.20 and altering its characteristic from flocculent to pulverulent during beer fermentation. An increase of six times was observed in amount of yeast cells in suspension in the second fermentation stage regarding to fermentations by yeast with no prior acidification. With alteration on two input variables, temperature curve and cell multiplication, which goal was to minimize the maximum values for diketones detected in the fermenter tank, a reduction was obtained from peak of formed diacetyl and consequently contributed to reduction in fermentation time and total process time. Several experiments were performed with those process changes in order to verify the influence on the total fermentation time and total vicinal diketones concentration at the end of fermentation. This experiment reached as the best production result a total fermentation time of 151 hours and total vicinal diketone concentration of 0.08 ppm. The mass of yeast in suspension in the second phase of fermentation increased from 2.45 x 106 to 16.38 x 106 cells/mL of yeast, which fact is key to a greater efficiency in reducing total vicinal diketones existing in the medium, confirming that the prior yeast acidification, as well as the control of temperature and yeast cell multiplication in fermentative process enhances the performance of diketones reduction and consequently reduce the total fermentation time with diketones concentration below the expected value (Max: 0.10 ppm)
Resumo:
The technology of anaerobic reactors for sanitary wastewater treatment has been extensively developed in Brazil, and today it is practically consolidated. They present several advantages, such as low construction and operating costs, and low sludge production, the anaerobic reactors are an attractive alternative to minimize problematic lack of basic sanitation in urban areas, and also of the rural areas. The anaerobic filters have been widely used in Brazil. It produces an effluent with low concentration of organic matter and solids suspended, besides conserving the nutrients, therefore, it is good for use in irrigation, but the practice must be associated with knowledge of the pathogens presence. The main objective of this study was to evaluate the efficiency of anaerobic filters in removal faecal coliforms and helminth eggs, and to verify if the effluent can be used for agricultural purposes, according to the World Organization of Health (WHO, 1989). The protocol used to enumerate helminths eggs was the modified Bailenger method, (Ayres and Mara, 1996) recommended by WHO for evaluation of raw effluent and treated effluent. The membrane filtration method was utilized to determine the concentrations of faecal coliforms. Three different systems of sewer treatment composed by anaerobic filters were analyzed. The results, in a general analysis, showed that all the researched systems reached a larger removal than 93% to helminth eggs, resulting in an effluent with smaller average than 1 egg/L. One of these systems, Sistema RN, reached a larger removal than 99%, confirming the good performance of the anaerobic filters in removal helminths eggs. Even with low concentrations of eggs in the influent, the filters were capable to remove this parameter efficiently. About faecal coliforms, it was observed for all the researched systems an effluent with 106 CFU/100mL. The high concentrations to faecal coliforms in the effluent just allow reuse for restricted irrigation, in agreement with the guidelines of WHO. Although the researched systems have not removed faecal coliforms efficiently, the results indicated a good efficiency of the anaerobic filters in removal helminth eggs
Resumo:
In Natal still dominates the use of individual disposal systems for domestic sewage, once only 29% of the city has a sewarage system. Wastes that are accumulated in these individual treatment systems should be exhausted periodically, service provided by collector entrepreneurs. Some of these companies causing major damage to the environment. In Natal, only two companies have their own septage (RESTI) treatment system, which were designed with parameters from domestic sewage generating strain and inefficient systems. Therefore, the characterization becomes essential as a source of parameters for their design. Thus, this work presents the physical-chemical and microbiological characterization of waste pumped from individual sewage treatment systems. Samples collections were made weekly from 5 different trucks at the reception point on the treatment plant on the point of the preliminary treatment. From each truck it was taken 5 samples during the discharge in order to make a composite sample. Afterwards, samples were carried out to laboratory and analyses for determination of temperature, pH, conductivity, BOD, COD, nitrogen (ammonia e organic), alkalinity, oils, phosphorus, solids, faecal coliforms and helminth egg. The results were treated as a single database, and ranked according to its generating source (multi and single house, lodging, health, services and / or food), area of origin (metropolitan, south and north) and type of system (cesspits, septic tank and / or sink). Through these data it was possible to verify that the type of system adopted by most in Natal and the metropolitan region is cesspit, besides to confirm the difference between the septage of areas with a population have different social and economical characteristics. It was found that the septage have higher concentrations than domestic sewage, except for thermotolerant coliforms that showed concentrations of 1,38E+07. Among the parameters studied, is the median values identified for COD (3,549 mg / L), BOD (973mg / L) and total solids (3.557mg / L). The volatile fraction constitutes about 70% of the total solids of the septage. For helminths has been a median of 7 eggs/L. In general, the characteristics of the waste followed the variability found in the literature reviewed for all variables, showing high amplitudes
Resumo:
Because of disability in public policy development in mind to attend issues of sanitation in the municipalities, companies known as "clean-blue" appeared proposing to solve a simple collection and management of wastewater produced in single or multifamily residences, commercial, hospitals, etc. In the case of an activity in which there are no worries about the fate of sewage, emerged some doubts about the degree of health and environmental safety in these companies. Traditionally, most of them makes the provision of waste depleted soil or wetland, open, usually located on the outskirts of cities (MENESES, 2001). In turn, the sludge from septic tanks exhausted, provided no technical criteria - in the soil, rivers and as an agricultural fertilizer put in risk the health of the population and environmental quality. This work was entered in the search network 5 of the Notice of the Research Program in Sanitation - PROSAB-5, aimed to study the theme 'Characterization and study of alternative ways of treating sludge from septic tanks in the city of Natal, RN', proposing to evaluate the performance of the use of stabilization ponds as a system to handle waste from septic tanks exhausted. A series of lakes studied belong to one of the largest clean-pit of Natal, consisting of two anaerobic ponds, one facultative and maturation, and a tank disinfection, the wastewater being released in the Potengi River. Samples were collected between the months of October 2007 to October 2008, at six points previously defined and judged as more appropriate to what is proposed study. The analysis results in field and laboratory showed the most significant removal of COD (88.93%), total suspended solids (94.87%), organic nitrogen (66.87%) and thermotolerant coliforms (99.88%). Some results have not reached the expected because the system under study had operating problems that have undermined the efficiency of the reactors
Resumo:
Only 32% of the population of Natal is attended by sewage, while the remaining population use pits and septic tanks. The characterization of the contents of septic tanks and pits contributes to the performance of such system and may guide the decision on treatment of these contents. The main of this research is to characterize the contents of interior residential pits and septic tanks in the greater Natal, with the following specific goals: to develop and manufacture a sampler capable of collecting a representative sample of the entire column (the surface scum, the clarified liquid and sludge bottom); to compare the contents of the tanks with the pits; to compare the contents of the septage from vacuum trucks; to relate the composition content with socioeconomic characteristics of households; to compare the content in both chambers of the septic tanks in series; to assess the situation of the content before and six months after the cleanness; and ultimately propose a pilot scale plant for treatment of septage. Once the sampler was developed, samples were collected within 14 septic tanks and 10 pits in many districts of Natal. Medians of the 24 systems were obtained: temperature, pH, conductivity, oil and grease, total solids, total suspended solids and sediments of 28.0 °C, 6.95; 882 mS/cm, 75.2 mg/L; 10,169 mg/L, 6,509 mg/L and 175 mL/L respectively; 111.0 mgN/L for ammonia, 130.5 mgN/ L for organic nitrogen, 0.2 mgN/L for nitrite, 0.4 mg/L for nitrate; 8935 mgO2/L for COD, 29.2 mgP/L for total phosphorus, thermotolerant coliforms from 9.95 E +06 CFU/100mL helminth eggs and 9.2 eggs/L with a maximum concentration of 688 eggs/L and minimum of 0 eggs/L. Medians of organic nitrogen and TKN were significantly different between groups of tanks and pits. The systems with cleanness gap from 11 and 20 years presented the higher concentrations for most variables. The effluent from the toilets and bathrooms participate more effectively in contributing fractions of solids, alkalinity, nitrogen, COD, total phosphorus, thermotolerant coliforms and helminth eggs. The systems used by socioeconomics class with income from R$ 3,700.00 to R$ 7,600.00, presented higher concentrations for COD, nitrogen, solids and helminth eggs. The first of the two chambers had always presented higher concentrations over the second compartment. The analysis of variance for most variables, showed that the values of septic tanks, pits and septage from vacuum trucks belong to the same group. In the samples taken after cleanness, the median of pH and temperature increased, while alkalinity, COD, organic nitrogen, total phosphorus, ammonia and helminth eggs decreased. The oils and greases and thermotolerant coliforms had slightly varied due to the continuous release of sewage into the systems that maintained their steady state concentrations.
Resumo:
The Serido is a region of northeastern Brazil highlighted by its problems related to water scarcity because of its semi-arid region, large rates of evaporation and rainfall irregular and scarce. Thus, the underground dams, become a strategically important resource with a simple and inexpensive technique for storage of water. They act in a positive way in the development of inland cities that suffer from drought, because in addition to exercise a great improvement in the social role of these families, can enjoy the type of soil (silt) and provides water for both irrigation and for human consumption throughout the year. Is therefore essential to its monitoring and studies to assess its effectiveness in accordance with its purposes, along with their wells Amazons, as can occur in conditions of physical degradation, chemical and microbiological appropriate, according to the Ordinance No 518/04 Ministry of Health, however, the proposed work aims to analyze the underground dams in the municipality of Sierra Negra North-RN (semi-arid region) as to their uses and their influences on the quality and quantity of water in periods of drought and rain. Analyzing monthly these parameters: determination of pH, conductivity, calcium, magnesium, sodium, potassium, chloride, sulfate, RAS (sodium adsorption ratio), turbidity, total iron, nitrite, nitrate, total dissolved solids (STD), bicarbonate (HCO3), fecal coliform and pesticides compared to the standards allowed by the Ordinance in force for quality for human consumption. While at the risk of salinity and sodicity on the model proposed by the United Salinity Laboratory (USSL). Although efficient, it was found that results varied annually on water quality which may influence their specific uses, whether or irrigation water supply in the city
Resumo:
The detention and infiltration ponds of urban drainage system has function to protect the population from undesirable effects of floods. In general these ponds are not completly used and it potential is wasted. As it are disseminated at different places at cities it can reduce costs with water transport and permit water preservation of best quality. Some it utilities includes use in green areas irrigation, industrial among than cooling towers and boiler, soil compaction, cleaning urban road, pisciculture and fire fighting system. The quality these water is influenced by anauthorized sewage in the drainage system. This study was performed in six detention and infiltration ponds at drainage system of Natal, which aim was to verify the non-portable use these ponds on urban environment. As indirect aim would to incentive the water utilization these ponds as a water source to another uses in urban environment. These ponds represents the characteristics of detention and infiltration of Natal city and consequently of Brazil. As the water quality, the ponds presents following characteristics: three has apparently good quality, other showed intermediate condition and two had water polluted. Were performed twenty sample in each ponds and the following parameters assessed: pH, temperature, dissolved oxygen, turbidity, electrical conductivity, coliform thermotolerant, ammonia, organic nitrogen, TKN, nitrate, total phosphorus and alkalinity, bicarbonate, chloride, total hardness, calcium and magnesium hardness, total solids, TSS, TDS, COD and SAR°. To utilization on pisciculture we recommend use in ponds which presents the best quality. Only one pond presented higher pollutants and it not being appropriated for use in cooling tower. The content of solids suspension restricted the water use in all ponds in boilers. As water use in soil compaction, cleaning urban road and fire fighting system the water from these ponds are not appropriated. However, the recommended limits from literature are to domestic sewage, due to this, the parameters are restrictive to diminish the sanitary risk that could be offered with it utilization. The infiltration velocity of water these assessed ponds restrict a moderato use, however the effects are potentiated only in soil less sandy, which not occur in Natal. It is recommend the unrestricted irrigation utilization in ponds with best quality of water, and a restricted irrigation to ponds with worst quality of water. As load of pollutants, it is recommended a complementary treatment in those ponds whit higher load to diminish sanitary risks. In only one pond was found one helminth eggs and due to the convention formula of results, it was found for all ponds less than 1 helminth/liter eggs.
Resumo:
Stabilization pond system consisting in more sewage treatment used in Rio Grande do Norte (RN), Brazil, representing about 90% of all systems. Fecal bacteria are removed mainly facultative ponds and in maturation ponds. Many factors influence bacterial decay, such as the levels of pH and DO, temperature, light intensity, HDT and nutrient availability. The bacterial decay rate (Kb) is calculated considering many variables, but the hydraulic regime is a significant influence for microorganisms removal, and the dispersed flow which best characterizes a stabilization pond. However, some authors developed equations for the Kb accordant plug flow and complete mixing. This research study aimed to evaluate the bacterial decay of fecal coliform and Enterococcus sp. in stabilization ponds designed to treat domestic sewage, full-scale, in RN. All systems have assessed pretreatment, a facultative pond (LF) followed by two maturation (LM1 and LM2). The parameters availed were: temperature, pH, DO, BOD5, COD, fecal coliform, Enterococcus sp., Chlorophyll a, total suspended solids, fixed and volatile. In general, there were not significant differences for pH, DO and temperature in the ponds, except for the new systems, since they have low flow and hydraulic loads. The removal of organic matter in the ponds was low, about 70%, and nearly all are overloaded organic and operational problems. The bacterial removals were low, with average 96% for LF for fecal coliform, and 98% for Enterococcus sp.; LM1 were in itself a removal for fecal coliform about 71%, and 81% for Enterococcus sp.; LM2 have efficiency of 69% for fecal coliform, and 68% for Enterococcus sp. The equation proposed by Von Sperling (1999), according to the dispersed flow regime, generated empirical values of Kb more approximate to calculated values of Kb. On average, the calculated Kb to coliforms in the LF was 0.31 d-1, and for both maturation ponds were 0.35 d-1. For Enterococcus sp. the average was 0.40 d-1 for LF, 0.55 d-1 for LM1, and 0.58 d-1 for LM2. These results also showed that the Kb obtained in full-scale systems are smaller than those found in pilot-scale ponds. Moreover, one can say that the equation proposed by Marais (1974), according to the complete-mix regime, overestimates Kb. Actual results of Kb indicated that fecal coliforms are more resistant to adverse conditions present in stabilization ponds than Enterococcus sp., therefore, an indicator of microbiological safety and efficiency. The factors significant interventions in the rate of bacterial decay were concentrations of COD, the organic loading and HDT. The few Kb relationship between pH, DO and temperature were not significant. Finally, we conclude that it s essential to correct operation and maintenance, for not performing these activities is one of the main factors contributing to low rates of bacterial decay.
Resumo:
Waste stabilization ponds are the main technology in use for domestic sewage treatment in Rio Grande do Norte State (RN), northeast Brazil. The are around 80 systems, constructed mainly by municipal city halls, being series comprised by a primary facultative pond followed by two maturation ponds the most used configuration. Due to problems related with the production and destination of sludge and generation of bad odors, the designers have avoided the use of anaerobic lagoons. The majority of systems are rarely monitored to verify their efficiencies and to get new project parameters for future designing. This work has as purpose to make a diagnosis of efficiency of three series of waste stabilization pond series (WSPS) of Jardim Lola 1, Jardim Lola 2 and Beira Rio, located in the North Zone of the city of the Natal/RN, treating domestic raw sewage, on the removal of organic matter and thermotolerant coliform, comparing the operational conditions of the systems this inside of the bands foreseen in the project, through parameters BOD5, QOD, thermotolerant coliforms, dissolved oxygen, pH, temperature, ammoniac nitrogen, total and suspended solids. The work was carried through in the WSPS, all constituted by a primary facultative pond followed by two maturation ponds. Socioeconomic characteristics of population are predominantly low and all the plants are very near of the contributing basins. The series were monitored from of May the November of 2002, totalizing 20 collections of grab samples of raw sewage and ponds effluents between 8:00 and 9:50 h. The main aspect to be detached by the results was the great concentration of organic matter (BOD and COD) and microorganisms the raw sewage which were around two times more concentrated than those values foreseen one in project. Considering all series the highest removals of organic matter were observed in system Beira Rio (84 and 78% of BOD and COD, respectively), which presented high hydraulic detention time (TDH = 89 days). On the other hand, Jardim Lola 1 and Jardim Lola 2 presented a much lower values of HDT (36 days and 18 days respectively) and their removals of BOD and COD were the same (76% and 60%, respectively). The Beira Rio WSPS, was the most efficient verified in relation to solids and ammonia, proving the great influence of the operational variables such as HDT and applied surface organic loadings on the performance of pond series. Although the treatment plants have reached efficiencies of thermotolerant coliforms around 99,999%, the concentrations in the final effluent can be considered very high for launching in aquatic bodies, particularly those produced by Jardim Lola 1 and Jardim Lola 2 series