23 resultados para Pond-Nuki
Resumo:
Leachates are effluent produced by decomposition of solid waste, they have complex composition and can be highly toxic. Therefore such percolated liquid should be collected and treated properly to avoid environmental contamination of soil and of water bodies. The objective of this study was to evaluate the toxicity through ecotoxicological tests with Ceriodaphnia dubia (Cladocera - Crustacea) of percolated liquids generated in two different systems of municipal solid waste (MSW) disposal in the city of Natal/ RN: A Sanitary Landfill in the Metropolitan Region of Natal/ RN, and in a dump off area. Furthermore, it was evaluated the possible contamination of the underground water of the dump off area. Two monthly samples were taken at four points between the months of May/2009 and January/2010. The Point "A" corresponds to the end of the pond leachate treatment in ASRMN; The Point "B" corresponds to a containment pond at the dump. The Point "C" is an area near one of the cells of the dump off area where the leachate outcrops; The Point "D" stands for an underground water well at the area. The last point, called "E" was sampled only once and corresponds to the slurry produced by temporary accumulation of solid waste in the open area of the dump. The ecotoxicological tests, acute and chronic, followed the ABNT 13373/2005 rules, with some modifications. The samples were characterized by measuring the pH number, the dissolved oxygen (DO), the salinity, BOD5, COD, Cd, Cu, Pb, Cr, Fe, Mg, Ni, and Zn. At Point A, the average number of EC50-48h ranged between 1.0% and 2.77% (v/v), showing a high toxicity of the leachate to C.dubia in all months. To this point, positive correlations were found between the EC50- 48 with precipitation. Negative correlations were found between the EC50- 48h with salinity. At point B there was no response of the acute exposure of organisms to the test samples. At point C the EC50-48h ranged from 17.68% to 35.36% in just two months of the five ones analyzed, not correlated meaning. Point D, the EC50-48h level ranged between 12.31% and 71.27%, showed a negative correlation with, only, precipitation. Although it was observed toxicity of underground water in the Landfill Area, there was no evidence of water contamination by leachate, however, due to the toxic character of this water, additional tests should be conducted to confirm the quality of water that is used for human supply. At point E there was no acute toxicity. These results support the dangers of inappropriate disposal of MSW to water bodies due to the high toxicity of the leachate produced highlighting the necessity of places of safe confinement and a treatment system more effective to it
Resumo:
Untreated effluents that reach surface water affect the aquatic life and humans. This study aimed to evaluate the wastewater s toxicity (municipal, industrial and shrimp pond effluents) released in the Estuarine Complex of Jundiaí- Potengi, Natal/RN, through chronic quantitative e qualitative toxicity tests using the test organism Mysidopsis Juniae, CRUSTACEA, MYSIDACEA (Silva, 1979). For this, a new methodology for viewing chronic effects on organisms of M. juniae was used (only renewal), based on another existing methodology to another testorganism very similar to M. Juniae, the M. Bahia (daily renewal).Toxicity tests 7 days duration were used for detecting effects on the survival and fecundity in M. juniae. Lethal Concentration 50% (LC50%) was determined by the Trimmed Spearman-Karber; Inhibition Concentration 50% (IC50%) in fecundity was determined by Linear Interpolation. ANOVA (One Way) tests (p = 0.05) were used to determinate the No Observed Effect Concentration (NOEC) and Low Observed Effect Concentration (LOEC). Effluents flows were measured and the toxic load of the effluents was estimated. Multivariate analysis - Principal Component Analysis (PCA) and Correspondence Analysis (CA) - identified the physic-chemical parameters better explain the patterns of toxicity found in survival and fecundity of M. juniae. We verified the feasibility of applying the only renewal system in chronic tests with M. Juniae. Most efluentes proved toxic on the survival and fecundity of M. Juniae, except for some shrimp pond effluents. The most toxic effluent was ETE Lagoa Aerada (LC50, 6.24%; IC50, 4.82%), ETE Quintas (LC50, 5.85%), Giselda Trigueiro Hospital (LC50, 2.05%), CLAN (LC50, 2.14%) and COTEMINAS (LC50, IC50 and 38.51%, 6.94%). The greatest toxic load was originated from ETE inefficient high flow effluents, textile effluents and CLAN. The organic load was related to the toxic effects of wastewater and hospital effluents in survival of M. Juniae, as well as heavy metals, total residual chlorine and phenols. In industrial effluents was found relationship between toxicity and organic load, phenols, oils and greases and benzene. The effects on fertility were related, in turn, with chlorine and heavy metals. Toxicity tests using other organisms of different trophic levels, as well as analysis of sediment toxicity are recommended to confirm the patterns found with M. Juniae. However, the results indicate the necessity for implementation and improvement of sewage treatment systems affluent to the Potengi s estuary
Resumo:
The objective of this study was to examine the growth of Gracilaria cervicornis cultured in a shrimp (Litopenaeus vannamei) pond and to determine the absorption efficiency and the kinetics parameters (Vmax, Ks e Vmax:Ks) of this macroalgae for the nutrients N-NO3-, N-NH4+ and P-PO4-3, aiming at its use as bioremediatory of eutrophicated environments. For this study, two experiments (field and laboratory) were developed. In the field study, the seaweed was examined in relation to the growth and the biomass. In the laboratory experiment, the absorption efficiency of G. cervicornis was measured through the monitoring of the concentration of the three nutrients (N-NO3-, N-NH4+ e P-PO4-3) during 5 hours and the kinetic parameters were determined through the formula of Michaelis-Menten. The results obtained in this study demonstrated that G. cervicornis benefited from the available nutrients in the pond, increasing 52.4% of its biomass value after 30 days of culture. It was evidenced that the variability of the biomass could be explained through the salinity, availability of light (transparency and solid particle in suspension) and concentration of N-NO3- in the environment. In the laboratory experiment, the highest absorption efficiency was found in the treatments with low concentration (5 µmol.L-1), being evidenced a reduction of up to 85,3%, 97,5% and 81,2% of N-NH4+, N-NO3- and P-PO43-, respectively. Regarding the kinetic parameters, G. cervicornis presented better ability in absorbing N-NH4+ in high concentrations (Vmax = 158,5 µmol g-1 dry wt h-1) and P-PO43- in low concentrations (Ks = 5 µmol.L-1 e Vmax:Ks = 10,3). The results of this study show that G. cervicornis could be cultivated in shrimp ponds, presents a good capacity of absorption for the tested nutrients and is a promising candidate for biorremediation in shrimp pond effluent
Resumo:
The main problem faced by the shrimp industry are the infectious diseases. The hypodermal and hematopoietic necrosis infection (IHHN) is one of the major cause of disease in the cultured shrimp, Litopenaeus vannamei. Environmental changes involving water quality, oxygen concentration, salinity, temperature, stocking density, presence of pathogens, among others, triggering a stressing condition for the cultured shrimp, weakening them and allowing the outbreak of diseases. The stress on the animal leads to a change in the molecules immune response components, which can be used as indicators of shrimp health. Thus, the objective of the present study was to evaluate the effect of salinity, stocking density and IHHNV infection on the L. vannamei shrimp. The immune parameters used to check the shrimp health were the total hemocytes counts (THC), the agglutinating activity (AA) and the clotting time (CT) of the serum of shrimp. These parameters were analyzed in healthy and IHHNV-infected shrimp, grown in low (0-0.5 ), medium (19-24 ) and high (> 38 ) salinity, and extensive (7-12 cam.m-2), semi-intensive (15-25 cam.m-2) and intensive (33-45 cam.m -2) stocking density. The IHHNV infection rate was significantly higher in low salinity (P<0.005) and intensive density (P<0.005), both stressful conditions for L. vannamei. Low salinity significantly increased THC (P<0.05) and decreased and CT (P<0.05) in healthy and infected shrimp, but AA (P<0.05) significantly decreased in healthy shrimp at medium salinity. Culture intensification did not affect the THC, AA and CT of healthy and infected shrimp (P>0.05). The IHHNV infection did not affect any immune parameters of shrimp cultured at different salinities and stocking densities. It is necessary to emphasize that this study was conducted in shrimp grown in ponds, where several environmental factors are acting simultaneously. Thus, further studies are needed about the influence of other environmental factors on the immune parameters of shrimp cultured in pond
Resumo:
Stabilization ponds are an effective sewage treatment alternative for the climatic conditions prevailing in Brazil. In the present work, a primary facultative pond was studied, in the city of Natal, Rio Grande do Norte, Northeast Brazil. The aim of this study was to evaluate the sedimentation dynamics in the facultative pond. The pond was divided in three section or zones along its length starting from the inlet end namely A1, A2 and A3. The research was accomplished in three phases. In the first the mapping of the sludge layer was done, sludge core samples were also collected for analysis for total, fixed and volatile solids and the depth of the sludge layer was determined using a portable echo sounder. In the second solids sedimentation rates were measured using traps placed in the inlet and outlet zones and in the third phase resuspension sludge was evaluate using a tracer. The amount accumulated sludge since the start operation was 13.583 m3. The sedimentation constant averages changed between 0.93 to 2.94 and 3.90 to 5.80 for the depths of 0.5 and 1.0 m respectively. The relationship between volatile and fixed solids (SV/SF) increased along the pond. The removal efficiencies were 52.12%, 36.09%, and 37.50% for BOD, COD and SS, respectively. The sludge accumulation model proposed had a good adjustment with 0.17 m3/hab.year rate. The results presented here demonstrated that the wind had a direct influence on the sedimentation of solids in this pond affecting the efficiency and sludge accumulation
Resumo:
Waste stabilization ponds (WSP) have been widely used for sewage treatment in hot climate regions because they are economic and environmentally sustainable. In the present study a WSP complex comprising a primary facultative pond (PFP) followed by two maturation ponds (MP-1 and MP-2) was studied, in the city of Natal-RN. The main objective was to study the bio-degradability of organic matter through the determination of the kinetic constant k throughout the system. The work was carried out in two phases. In the first, the variability in BOD, COD and TOC concentrations and an analysis of the relations between these parameters, in the influent raw sewage, pond effluents and in specific areas inside the ponds was studied. In the second stage, the decay rate for organic matter (k) was determined throughout the system based on BOD tests on the influent sewage, pond effluents and water column samples taken from fixed locations within the ponds, using the mathematical methods of Least Squares and the Thomas equation. Subsequently k was estimated as a function of a hydrodynamic model determined from the dispersion number (d), using empirical methods and a Partial Hydrodynamic Evaluation (PHE), obtained from tracer studies in a section of the primary facultative pond corresponding to 10% of its total length. The concentrations of biodegradable organic matter, measured as BOD and COD, gradually reduced through the series of ponds, giving overall removal efficiencies of 71.95% for BOD and of 52.45% for COD. Determining the values for k, in the influent and effluent samples of the ponds using the mathematical method of Least Squares, gave the following values respectively: primary facultative pond (0,23 day-1 and 0,09 day-1), maturation 1 (0,04 day-1 and 0,03 day-1) and maturation 2 (0,03 day-1 and 0,08 day-1). When using the Thomas method, the values of k in the influents and effluents of the ponds were: primary facultative pond (0,17 day-1 and 0,07 day-1), maturation 1 (0,02 day-1 and 0,01 day-1) and maturation 2 (0,01 day-1 and 0,02 day-1). From the Partial Hydrodynamic Evaluation, in the first section of the facultative pond corresponding to 10% of its total length, it can be concluded from the dispersion number obtained of d = 0.04, that the hydraulic regime is one of dispersed flow with a kinetic constant value of 0.20 day-1
Resumo:
The Pitimbu River Basin is concern reason, therefore this is one of the mains freshwater sources for the Natal city supplying. The Pitimbu waters river flow into Jiqui pond, as the main supplier of this, that supplies 16% of Natal population and there is a bigger importance despite the supplying of a parcel of Natal city made joining underground waters with the water proceeding from the Jiqui pond, being used for dilution waters of contaminated wells with nitrate. Even with the importance of the Pitimbu, there is a strong pressure of occupation of its edge according to a critical urban growth, becoming the situation worse and increasing the necessity of management of the use and occupation of the ground and keeping the control of the prompt pollution, as punctual as diffuse. There are many studies about Pitimbu River Basin, however they summarize themselves to some months or even in a few years. This work, that gathers these information, increasing the amplitude and making possible an evaluation of the attitude of the water in a period extended for an evaluation of values of variable quality of water referring to the standards, that usually happens about the variable frequency distribution, central tendency and measures of dispersion, as the coefficient of variation, coefficient of skewness and the coefficient of determination of certain variable on another one. This work to evaluates the quality conditions of the Pitimbu river waters by analyzing thirty five (35) variables Physical, chemical and biological in eight (8) points of water course since 1993 to 2007. Given this situation, all knowledge about the waters quality conditions obtained in this work, is a strong subsidy for management of use and ground occupation, considering the river basin as territorial unit of management, and as the water is public good domain, being a priority human use, It is necessary to guarantee to current and the future generations available water resources in appropriate standards of quality as the established standard and identifying possible reasons of pollution through statistics analysis
Resumo:
The detention and infiltration ponds of urban drainage system has function to protect the population from undesirable effects of floods. In general these ponds are not completly used and it potential is wasted. As it are disseminated at different places at cities it can reduce costs with water transport and permit water preservation of best quality. Some it utilities includes use in green areas irrigation, industrial among than cooling towers and boiler, soil compaction, cleaning urban road, pisciculture and fire fighting system. The quality these water is influenced by anauthorized sewage in the drainage system. This study was performed in six detention and infiltration ponds at drainage system of Natal, which aim was to verify the non-portable use these ponds on urban environment. As indirect aim would to incentive the water utilization these ponds as a water source to another uses in urban environment. These ponds represents the characteristics of detention and infiltration of Natal city and consequently of Brazil. As the water quality, the ponds presents following characteristics: three has apparently good quality, other showed intermediate condition and two had water polluted. Were performed twenty sample in each ponds and the following parameters assessed: pH, temperature, dissolved oxygen, turbidity, electrical conductivity, coliform thermotolerant, ammonia, organic nitrogen, TKN, nitrate, total phosphorus and alkalinity, bicarbonate, chloride, total hardness, calcium and magnesium hardness, total solids, TSS, TDS, COD and SAR°. To utilization on pisciculture we recommend use in ponds which presents the best quality. Only one pond presented higher pollutants and it not being appropriated for use in cooling tower. The content of solids suspension restricted the water use in all ponds in boilers. As water use in soil compaction, cleaning urban road and fire fighting system the water from these ponds are not appropriated. However, the recommended limits from literature are to domestic sewage, due to this, the parameters are restrictive to diminish the sanitary risk that could be offered with it utilization. The infiltration velocity of water these assessed ponds restrict a moderato use, however the effects are potentiated only in soil less sandy, which not occur in Natal. It is recommend the unrestricted irrigation utilization in ponds with best quality of water, and a restricted irrigation to ponds with worst quality of water. As load of pollutants, it is recommended a complementary treatment in those ponds whit higher load to diminish sanitary risks. In only one pond was found one helminth eggs and due to the convention formula of results, it was found for all ponds less than 1 helminth/liter eggs.
Resumo:
Stabilization pond system consisting in more sewage treatment used in Rio Grande do Norte (RN), Brazil, representing about 90% of all systems. Fecal bacteria are removed mainly facultative ponds and in maturation ponds. Many factors influence bacterial decay, such as the levels of pH and DO, temperature, light intensity, HDT and nutrient availability. The bacterial decay rate (Kb) is calculated considering many variables, but the hydraulic regime is a significant influence for microorganisms removal, and the dispersed flow which best characterizes a stabilization pond. However, some authors developed equations for the Kb accordant plug flow and complete mixing. This research study aimed to evaluate the bacterial decay of fecal coliform and Enterococcus sp. in stabilization ponds designed to treat domestic sewage, full-scale, in RN. All systems have assessed pretreatment, a facultative pond (LF) followed by two maturation (LM1 and LM2). The parameters availed were: temperature, pH, DO, BOD5, COD, fecal coliform, Enterococcus sp., Chlorophyll a, total suspended solids, fixed and volatile. In general, there were not significant differences for pH, DO and temperature in the ponds, except for the new systems, since they have low flow and hydraulic loads. The removal of organic matter in the ponds was low, about 70%, and nearly all are overloaded organic and operational problems. The bacterial removals were low, with average 96% for LF for fecal coliform, and 98% for Enterococcus sp.; LM1 were in itself a removal for fecal coliform about 71%, and 81% for Enterococcus sp.; LM2 have efficiency of 69% for fecal coliform, and 68% for Enterococcus sp. The equation proposed by Von Sperling (1999), according to the dispersed flow regime, generated empirical values of Kb more approximate to calculated values of Kb. On average, the calculated Kb to coliforms in the LF was 0.31 d-1, and for both maturation ponds were 0.35 d-1. For Enterococcus sp. the average was 0.40 d-1 for LF, 0.55 d-1 for LM1, and 0.58 d-1 for LM2. These results also showed that the Kb obtained in full-scale systems are smaller than those found in pilot-scale ponds. Moreover, one can say that the equation proposed by Marais (1974), according to the complete-mix regime, overestimates Kb. Actual results of Kb indicated that fecal coliforms are more resistant to adverse conditions present in stabilization ponds than Enterococcus sp., therefore, an indicator of microbiological safety and efficiency. The factors significant interventions in the rate of bacterial decay were concentrations of COD, the organic loading and HDT. The few Kb relationship between pH, DO and temperature were not significant. Finally, we conclude that it s essential to correct operation and maintenance, for not performing these activities is one of the main factors contributing to low rates of bacterial decay.
Resumo:
Urban stormwater can be considered as potential water resources as well as problems for the proper functioning of the manifold activities of the city, resulting from inappropriate use and occupation of the soil, usually due to poor planning of the occupation of the development areas, with little care for the environmental aspects of the drainage of surface runoff. As a basic premise, we must seek mechanisms to preserve the natural flow in all stages of development of an urban area, preserving the soil infiltration capacity in the scale of the urban area, comprising the mechanisms of natural drainage, and noting preserving natural areas of dynamic water courses, both in the main channel and in the secondary. They are challenges for a sustainable urban development in a harmonious coexistence of modern developmental, which are consistent with the authoritative economic environmental and social quality. Integrated studies involving the quantity and quality of rainwater are absolutely necessary to achieve understanding and obtaining appropriate technologies, involving both aspects of the drainage problems and aspects of use of water when subjected to an adequate management of surface runoff , for example, the accumulation of these reservoirs in detention with the possibility of use for other purposes. The purpose of this study aims to develop a computer model, adjusted to prevailing conditions of an experimental urban watershed in order to enable the implementation of management practices for water resources, hydrological simulations of quantity and, in a preliminary way, the quality of stormwater that flow to a pond located at the downstream end of the basin. To this end, we used in parallel with the distributed model SWMM data raised the basin with the highest possible resolution to allow the simulation of diffuse loads, heterogeneous characteristics of the basin both in terms of hydrological and hydraulic parameters on the use and occupation soil. The parallel work should improve the degree of understanding of the phenomena simulated in the basin as well as the activity of the calibration models, and this is supported by monitoring data acquired during the duration of the project MAPLU (Urban Stormwater Management) belonging to the network PROSAB (Research Program in Basic Sanitation) in the years 2006 to 2008
Resumo:
Stabilization pond is the main technology used for treatment wastewater, in northeast Brazil, due to lower cost of deployment, operation and maintenance compared to other technologies. Most systems of stabilization ponds has been in operation for some time, on average 10 years of operation, receiving high organic loads and do not have good removal efficiencies of the main parameters for which have been designed. Therefore it is necessary to work to quantify the efficiency of current systems. This study evaluated the biodegradability of organic matter in raw sewage, the removal of organic matter in reactors and determination of the kinetic constant removal of organic matter (k), both in reactors and in raw sewage, based on the analysis made in the laboratory and through mathematical methods proposed in the literature, in nine systems stabilization ponds, located in Rio Grande do Norte. In relation the degradation kinetics in stabilization ponds, it was observed that many papers published in the literature were obtained in pilot-scale systems, which often, due to the action of external factors such as wind and temperature, these can t be considered as a reference in the analysis of the kinetic constant K, so the need for more research into systems of scale. This study had three distinct phases and simultaneous, routine monitoring, study of the daily cycle and the determination of kinetic constant of degradation of organic matter (K). The monitoring showed that the removal efficiencies of organic matter on most systems were lower than suggested by the literature, the best efficiencies of around 76% (BOD) and 72% (COD) and the worst of the order of 48% (BOD) and 55% (COD). The calculation of K in raw sewage (Ke) was within the range of variation expected in the literature (0.35 to 0.60 days-1). Already for the results obtained for K in the reactors (Kr), there were well below the values recommended in the literature (0.25 to 0.40 d-1 for complete mix and from 0.13 to 0.17 d-1 for flow dispersed), in line with the overloads that organic systems are subject
Resumo:
The simulation of SES-Natal Ponta Negra: mitigation of environmental risks and predictive maintenance strategy was developed in the context of several operational irregularities in the pumping stations and sewage systems in the system Ponta Negra. Thus, the environmental risks and complaints against the company due to overflows of sewage into the public thoroughfare became common. This neighborhood has shown in recent years an increase of resident higher than the initial expectation of growth. In this sense presumed the large population growth and generation of sewers higher than expected, associated to the use of corrective maintenance and misuse of the system may be the main causes of operational failures occurring in the SES. This study aimed at analyzing the hydraulic behavior of SES Ponta Negrathrough numerical simulation of its operation associated to future scenarios of occupation. The SES Ponta Negra has a long lengthof collection networks and 6 pumping stations interconnected, being EE 1, 2, 4 coastal way, and beach Shopping interconnected EE3 to receives all sewers pumped from the rest pumping station and pumped to the sewage treatment station of neighborhood which consists of a facultative pond followed by three maturation ponds with disposal of treated effluent into infiltration ditches. Oncethey are connected with each other, the study was conducted considering the days and times of higher inflow for all lifts. Furthermore, with the aim of measuring the gatherer network failures were conducted data survey of on the networks. Thephysical and operational survey data was conducted between January/2011 and janeiro/2012. The simulation of the SES was developed with the aim ofdemonstrating its functioning, eithercurrently and in the coming years, based in population estimates and sewage flow. The collected data represents the current framework of the pumping stations of the SES Ponta Negra and served as input to the model developed in MS Excel ® spreadsheet which allowed simulating the behavior of SES in future scenarios. The results of this study show thatBeach Shopping Pumping Station is actually undersized and presents serious functioning problemsthatmay compromise the environmental quality of surrounding area. The other pumping stations of the system will reach itsmaximum capacity between 2013 and 2015, although the EE1 and EE3 demonstrateoperation capacity, even precariously, until 2017. Moreover, it was observed that the misuse of the network system, due to the input of both garbage and stormwater, are major factors of failures that occur in the SES. Finally, it was found that the corrective maintenance appliance, rather than predictive,has proven to beinefficient because of the serious failuresin the system, causing damage to the environment and health risks to users
Resumo:
Experience in the use of stabilization ponds shows that this is a system with low cost, easy operation and maintenance and suitable for tropical countries. One of its disadvantages is due to high concentrations of suspended solids, mainly due to algal biomass in the effluents. Accordingly, the dissolved air flotation has been shown to be an efficient post-treatment technology. However, the efficiency of this process is related to coagulation and flocculation steps, as well as the adjustment of the involved variables in the process. The objective of this work was to evaluate the algae removal efficiency from wastewater stabilization ponds and the influence of the factors involved in the process using dissolved air flotation. For this, we used primary facultative and maturation effluents of ETE Ponta Negra in Natal. We did tests of coagulation, flocculation and flotation with the samples, using the equipment flotatest. In this process were tested coagulants aluminum sulfate and ferric chloride, and varied the factors pH, coagulant concentration, polymer concentration and rate of recirculation. At the end of the experiments were analyzed turbidity, suspended solids, color, COD and chlorophyll "a". These results were submitted to descriptive statistics to verify the efficiency of the process in general, and regression analysis to identify models that describe the process and demonstrate the factors that have greater influence on flotation. After step methodology, high values were found removal efficiency of suspended solids, reaching values greater than 90% in the best cases. It was concluded that flotation is more efficient in the facultative pond effluent using ferric chloride, and the variability of algae may negatively influence the process. Regression analyzes showed that pH is the most influential variable in the coagulation-flocculation-flotation, and its optimal value among the tested is 5.5 for both coagulants
Resumo:
Stabilization pond is the most used sewage treatment system in the country, corresponding to approximately 90% of all systems. The systems evaluated were stabilization ponds system of sewage treatment in the city of Natal / RN. This research aimed to analyze the possible uses through physical-chemical and bacteriological of these final effluent ponds for urban uses depending on the characteristics after passage around the treatment system. The parameters used were chosen according to those established by Chernicharo et al. (2006), in order to characterize the effluent. The parameters evaluated were: DO, temperature, pH, conductivity, organic nitrogen, ammonia, NTK, total phosphorus, and series of solid fecal coliforms. Generally, the characteristics of the effluent followed variability found in the literature. The results showed an efficiency that is technically feasible to use the effluent end of some of STPs analyzed when checked parameters alone, if fitting in unrestricted urban use, restricted use and urban land use
Resumo:
The sludge generated in stabilization ponds can be designed for various purposes, among them we mention agricultural use, recovery of degraded areas and civil construction. The choice of these alternatives should be made based on qualitative and quantitative characteristics of the sludge. In this context, this study characterized the digested sludge from an anaerobic lagoon in Cidade do Natal/RN, which deals exclusively with residues of depleted septic tanks and pits. The sludge showed levels of macro and micronutrients that confirm its potential for agriculture, with 139.49 g.kg -1 organic matter, 15.40 g.kg-1 nitrogen and metal concentrations below those required by Resolution No. 375/06 of CONAMA, besides the absence of fecal coliform and less than 0.15 viable helminthes eggs/g, on average. The particle size distribution showed that most of the particles have a diameter similar to the sand, allowing the replacement of this input, for example. Analysis of the leachate and of the sludge solubilized classified as non-inert and non-hazardous according to NBR 10.004/04. The volume produced in three years of operation by the pond was 1903.50m³, equivalent to approximately 400 kg of dry sludge. Overall, the concentrations of the parameters were similar to literature, although none of them addresses sludge anaerobic pond treating sewer from septic tanks and pits.The sludgepresents technical feasibility to various types of use, however the cost of dewatering and especially with transport can derail it. It needs to be made a more thorough study of the costs to prove its economic viability