4 resultados para Method of quantification
em Repositório Digital da UNIVERSIDADE DA MADEIRA - Portugal
Resumo:
This paper reports on the development and optimization of a modified Quick, Easy, Cheap Effective, Rugged and Safe (QuEChERS) based extraction technique coupled with a clean-up dispersive-solid phase extraction (dSPE) as a new, reliable and powerful strategy to enhance the extraction efficiency of free low molecular-weight polyphenols in selected species of dietary vegetables. The process involves two simple steps. First, the homogenized samples are extracted and partitioned using an organic solvent and salt solution. Then, the supernatant is further extracted and cleaned using a dSPE technique. Final clear extracts of vegetables were concentrated under vacuum to near dryness and taken up into initial mobile phase (0.1% formic acid and 20% methanol). The separation and quantification of free low molecular weight polyphenols from the vegetable extracts was achieved by ultrahigh pressure liquid chromatography (UHPLC) equipped with a phodiode array (PDA) detection system and a Trifunctional High Strength Silica capillary analytical column (HSS T3), specially designed for polar compounds. The performance of the method was assessed by studying the selectivity, linear dynamic range, the limit of detection (LOD) and limit of quantification (LOQ), precision, trueness, and matrix effects. The validation parameters of the method showed satisfactory figures of merit. Good linearity (View the MathML sourceRvalues2>0.954; (+)-catechin in carrot samples) was achieved at the studied concentration range. Reproducibility was better than 3%. Consistent recoveries of polyphenols ranging from 78.4 to 99.9% were observed when all target vegetable samples were spiked at two concentration levels, with relative standard deviations (RSDs, n = 5) lower than 2.9%. The LODs and the LOQs ranged from 0.005 μg mL−1 (trans-resveratrol, carrot) to 0.62 μg mL−1 (syringic acid, garlic) and from 0.016 μg mL−1 (trans-resveratrol, carrot) to 0.87 μg mL−1 ((+)-catechin, carrot) depending on the compound. The method was applied for studying the occurrence of free low molecular weight polyphenols in eight selected dietary vegetables (broccoli, tomato, carrot, garlic, onion, red pepper, green pepper and beetroot), providing a valuable and promising tool for food quality evaluation.
Resumo:
A method for the simultaneous determination of major and minor volatiles composition in different types (dry, medium dry, sweet and medium sweet) of a young Tinta Negra Mole (TNM) monovarietal red wine from 2003 harvest has been validated. Wine samples preparation includes a dichloromethane liquid–liquid extraction followed by concentration under a nitrogen atmosphere. The extracted fraction was analysed by gas chromatography–mass spectrometry and give quantitative information for more than 86 analytes whose concentration range from few μg l−1 to 259.1 mg l−1. The method enables high recovery of volatile compounds in wine good linearity with (r2) values higher than 0.980 and good sensitivity. The limits of detection range from 0.003 to 0.534 mg l−1 and limits of quantification from 0.009 to 1.170 mg l−1. The method allows satisfactory determination of more than 80 compounds in the TNM red wines. These wines are characterized by a high content of higher alcohols, ethyl esters, fatty acids and lactones. The levels of sulphur compounds in Tinta Negra Mole medium sweet wines are very low, but they have the highest concentration of carbonyl compounds. Quantitative analysis of the main odorants followed by the determination of aroma index allow us elucidate the aroma of these varieties. On the basis of their odour description and odour threshold, the most powerful odorants of Tinta Negra Mole wines were tentatively established.
Resumo:
Tomato (Lycopersicon esculentum L.) is one of the main constituents of the Mediterranean diet. Its consumption has been proposed to reduce the risk of cardiovascular diseases and certain types of cancer. It is therefore one of the most popular and extensively consumed vegetable crop worldwide. To gain insights on the potential of Lycopersicon esculentum L. as bioactive food, two analytical methodologies were developed to determine the levels of the lipophilic -tocopherol, α-tocopherol, β-carotene, lycopene; and hydrophilic antioxidants ascorbic acid. The quantification of total carotenoids (β-carotene and lycopene) was assessed through a liquid–liquid ultrasound assisted extraction (LL-USAE) in combination with ultraviolet-visible spectroscopy (UV-Vis), according to method of mean, for total carotenoids (λmáx = 450 nm. The ultra-high performance liquid chromatographic using both photodiode array and fluorescence detection (UHPLC-PDA/FLR), allows the identification and quantification of the target lipophilic and hydrophilic antioxidants. This methodology UHPLC-PDA/FLR is fast, simple and revealed a high sensitivity for the compounds under study. The limits of detection (LODs) and quantification (LOQs) obtained were much lower (about 10 times) than the reported in literature. The method LL-USAE/UV-Vis was validated and applied to different tomato foodstuffs. The results reveal a small increase of carotenoids content during maturation, reaching the maximum level when ripe. These results complement those obtained by the ORAC and TBARS assays that show an increase of antioxidant capacity during maturation. The LODs ans LOQs obtained were also about 10 times lower than reported in literature. The carotenoid content was also evaluated by LL-USAE/UV-Vis in different tomatoes varieties. Regional variety present the high carotenoid level, followed by campari and gordal, and at last grape. This methodology was also applied to different processed food samples containing tomatoes derivatives. Highest carotenoids content were obtained in concentrated tomato foodstuffs.
Resumo:
A large number of evidences correlate elevated levels of homocysteine (Hcys) with a higher cardiovascular diseases (CVDs) risk, especially, atherosclerosis. Similarly, abnormal low levels of the vitamins B6, B9 and B12 are associated to an instability in the methionine cycle with an over production of Hcys. Thus, biomedical sciences are looking forward for a cheaper, faster, precise and accurate analytical methodology to quantify these compounds in a suitable format for the clinical environment. Therefore the objective of this study was the development of a simple, inexpensive and appropriate methodology to use at the clinical level. To achieve this goal, a procedure integrating a digitally controlled (eVol®) microextraction by packed sorbent (MEPS) and an ultra performance liquid chromatography (UPLC) coupled to a photodiode array detector (PDA) was developed to identify and quantify Hcys vitamins B6, B9 and B12. Although different conditions were assayed, we were not able to combine Hcys with the vitamins in the same analytical procedure, and so we proceeded to the optimization of two methods differing only in the composition of the gradient of the mobile phase and the injected volume. It was found that MEPS did not bring any benefit to the quantification of the Hcys in the plasma. Therefore, we developed and validate an alternative method that uses the direct injection of treated plasma (reduced and precipitated). This same method was evaluated in terms of selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), matrix effect and precision (intra-and inter-day) and applied to the determination of Hcys in a group composed by patients presenting augmented CVD risk. Good results in terms of selectivity and linearity (R2> 0.9968) were obtained, being the values of LOD and LOQ 0.007 and 0.21 mol / L, respectively. The intra-day precision (1.23-3.32%), inter-day precision (5.43-6.99%) and the recovery rate (82.5 to 93.1%) of this method were satisfactory. The matrix effect (>120%) was, however, higher than we were waiting for. Using this methodology it was possible to determine the amount of Hcys in real plasma samples from individuals presenting augmented CVD risk. Regarding the methodology developed for vitamins, despite the optimization of the extraction technique and the chromatographic conditions, it was found that the levels usually present in plasma are far below the sensitivity we obtained. Therefore, further optimizations of the methodology developed are needed. As conclusion, part of the objectives of this study was achieved with the development of a quick, simple and cheaper method for the quantification of Hcys.