2 resultados para Load-cycle analysis
em Repositório Digital da UNIVERSIDADE DA MADEIRA - Portugal
Resumo:
In a world where organizations are ever more complex the need for the knowledge of the organizational self is a growing necessity. The DEMO methodology sets a goal in achieving the specification of the organizational self capturing the essence of the organization in way independent of its implementation and also coherent, consistent, complete, modular and objective. But having such organization self notion is of little meaning if this notion is not shared by the organization actors. To achieve this goal in a society that has grown attached to technology and where time is of utmost importance, using a tool such as a semantic Wikipedia may be the perfect way of making the information accessible. However, to establish DEMO methodology in such platform there is a need to create bridges between its modeling components and semantic Wikipedia. It’s in that aspect that our thesis focuses, trying to establish and implement, using a study case, the principles of a way of transforming the DEMO methodology diagrams in comprehensive pages on semantic Wikipedia but keeping them as abstract as possible to allow expansibility and generalization to all diagrams without losing any valuable information so that, if that is the wish, those diagrams may be recreated from the semantic pages and make this process a full cycle.
Resumo:
A new approach based on microextraction by packed sorbent (MEPS) and reversed-phase high-throughput ultra high pressure liquid chromatography (UHPLC) method that uses a gradient elution and diode array detection to quantitate three biologically active flavonols in wines, myricetin, quercetin, and kaempferol, is described. In addition to performing routine experiments to establish the validity of the assay to internationally accepted criteria (selectivity, linearity, sensitivity, precision, accuracy), experiments are included to assess the effect of the important experimental parameters such as the type of sorbent material (C2, C8, C18, SIL, and C8/SCX), number of extraction cycles (extract-discard), elution volume, sample volume, and ethanol content, on the MEPS performance. The optimal conditions of MEPS extraction were obtained using C8 sorbent and small sample volumes (250 μL) in five extraction cycle and in a short time period (about 5 min for the entire sample preparation step). Under optimized conditions, excellent linearity View the MathML source(Rvalues2>0.9963), limits of detection of 0.006 μg mL−1 (quercetin) to 0.013 μg mL−1 (myricetin) and precision within 0.5–3.1% were observed for the target flavonols. The average recoveries of myricetin, quercetin and kaempferol for real samples were 83.0–97.7% with relative standard deviation (RSD, %) lower than 1.6%. The results obtained showed that the most abundant flavonol in the analyzed samples was myricetin (5.8 ± 3.7 μg mL−1). Quercetin (0.97 ± 0.41 μg mL−1) and kaempferol (0.66 ± 0.24 μg mL−1) were found in a lower concentration. The optimized MEPSC8 method was compared with a reverse-phase solid-phase extraction (SPE) procedure using as sorbent a macroporous copolymer made from a balanced ratio of two monomers, the lipophilic divinylbenzene and the hydrophilic N-vinylpyrrolidone (Oasis HLB) were used as reference. MEPSC8 approach offers an attractive alternative for analysis of flavonols in wines, providing a number of advantages including highest extraction efficiency (from 85.9 ± 0.9% to 92.1 ± 0.5%) in the shortest extraction time with low solvent consumption, fast sample throughput, more environmentally friendly and easy to perform.