2 resultados para High Performance

em Repositório Digital da UNIVERSIDADE DA MADEIRA - Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work aims to study and analyze strategies and measures to improve energy performance in residential and service buildings, in order to minimize energy losses and energy consumption. Due to the high energy dependence of European Union (EU), including Portugal and Slovenia, and high percentage of energy consumption in the building sector, there was a need to adopt strategies at European level with ambitious goals. This came to force EU - Member States to take measures to achieve the proposed targets for energy consumption reduction. To this end, EU - Member States have adapted the laws to their needs and formed specialized agencies and qualified experts on energy certification, which somehow evaluate buildings according to their performance. In this study, the external characteristics of the building in order to meet its thermal needs and from there to survey the existing and possible constructive solutions to be used at the envelope will be examined, in order to increase comfort and reduce the need of use technical means of air conditioning. The possibility of passive heating and ventilation systems also will be discussed. These techniques are developed in parallel with the deployment and design of the building. In this manner, to reduce the energy consumption, various techniques and technologies exploit natural resources. Thus, appear the more sustainable and efficient buildings, so-called Green Buildings have been appeared. The study ends with the identification of measures used in several buildings, proving the economic return in the medium to long term, as well as the satisfaction of their users.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This manuscript describes the development and validation of an ultra-fast, efficient, and high throughput analytical method based on ultra-high performance liquid chromatography (UHPLC) equipped with a photodiode array (PDA) detection system, for the simultaneous analysis of fifteen bioactive metabolites: gallic acid, protocatechuic acid, (−)-catechin, gentisic acid, (−)-epicatechin, syringic acid, p-coumaric acid, ferulic acid, m-coumaric acid, rutin, trans-resveratrol, myricetin, quercetin, cinnamic acid and kaempferol, in wines. A 50-mm column packed with 1.7-μm particles operating at elevated pressure (UHPLC strategy) was selected to attain ultra-fast analysis and highly efficient separations. In order to reduce the complexity of wine extract and improve the recovery efficiency, a reverse-phase solid-phase extraction (SPE) procedure using as sorbent a new macroporous copolymer made from a balanced ratio of two monomers, the lipophilic divinylbenzene and the hydrophilic N-vinylpyrrolidone (Oasis™ HLB), was performed prior to UHPLC–PDA analysis. The calibration curves of bioactive metabolites showed good linearity within the established range. Limits of detection (LOD) and quantification (LOQ) ranged from 0.006 μg mL−1 to 0.58 μg mL−1, and from 0.019 μg mL−1 to 1.94 μg mL−1, for gallic and gentisic acids, respectively. The average recoveries ± SD for the three levels of concentration tested (n = 9) in red and white wines were, respectively, 89 ± 3% and 90 ± 2%. The repeatability expressed as relative standard deviation (RSD) was below 10% for all the metabolites assayed. The validated method was then applied to red and white wines from different geographical origins (Azores, Canary and Madeira Islands). The most abundant component in the analysed red wines was (−)-epicatechin followed by (−)-catechin and rutin, whereas in white wines syringic and p-coumaric acids were found the major phenolic metabolites. The method was completely validated, providing a sensitive analysis for bioactive phenolic metabolites detection and showing satisfactory data for all the parameters tested. Moreover, was revealed as an ultra-fast approach allowing the separation of the fifteen bioactive metabolites investigated with high resolution power within 5 min.