2 resultados para Field-stepped direct detection
em Repositório Digital da UNIVERSIDADE DA MADEIRA - Portugal
Resumo:
This thesis explores the possibility of directly detecting blackbody emission from Primordial Black Holes (PBHs). A PBH might form when a cosmological density uctuation with wavenumber k, that was once stretched to scales much larger than the Hubble radius during ination, reenters inside the Hubble radius at some later epoch. By modeling these uctuations with a running{tilt power{law spectrum (n(k) = n0 + a1(k)n1 + a2(k)n2 + a3(k)n3; n0 = 0:951; n1 = ????0:055; n2 and n3 unknown) each pair (n2,n3) gives a di erent n(k) curve with a maximum value (n+) located at some instant (t+). The (n+,t+) parameter space [(1:20,10????23 s) to (2:00,109 s)] has t+ = 10????23 s{109 s and n+ = 1:20{2:00 in order to encompass the formation of PBHs in the mass range 1015 g{1010M (from the ones exploding at present to the most massive known). It was evenly sampled: n+ every 0.02; t+ every order of magnitude. We thus have 41 33 = 1353 di erent cases. However, 820 of these ( 61%) are excluded (because they would provide a PBH population large enough to close the Universe) and we are left with 533 cases for further study. Although only sub{stellar PBHs ( 1M ) are hot enough to be detected at large distances we studied PBHs with 1015 g{1010M and determined how many might have formed and still exist in the Universe. Thus, for each of the 533 (n+,t+) pairs we determined the fraction of the Universe going into PBHs at each epoch ( ), the PBH density parameter (PBH), the PBH number density (nPBH), the total number of PBHs in the Universe (N), and the distance to the nearest one (d). As a rst result, 14% of these (72 cases) give, at least, one PBH within the observable Universe, one{third being sub{stellar and the remaining evenly spliting into stellar, intermediate mass and supermassive. Secondly, we found that the nearest stellar mass PBH might be at 32 pc, while the nearest intermediate mass and supermassive PBHs might be 100 and 1000 times farther, respectively. Finally, for 6% of the cases (four in 72) we might have substellar mass PBHs within 1 pc. One of these cases implies a population of 105 PBHs, with a mass of 1018 g(similar to Halley's comet), within the Oort cloud, which means that the nearest PBH might be as close as 103 AU. Such a PBH could be directly detected with a probability of 10????21 (cf. 10????32 for low{energy neutrinos). We speculate in this possibility.
Resumo:
This article proposes a simple and sensitive HPLC method with photo-diode array detection for the analysis of organic acids, monomeric polyphenols and furanic compounds in wine samples by direct injection. The chromatographic separation of 8 organic acids, 2 furans and 22 phenolic compounds was carried out with a buffered solution (pH 2.70) and acetonitrile as mobile phases and a difunctionally bonded C18 stationary phase, Atlantis dC18 (250 4.6 mm, 5mm) column. The elution was performed in 12 min for the organic acids and in 60 min for the phenolic compounds, including phenolic acids, stilbenes and flavonoids. Target compounds were detected at 210 nm (organic acids, flavan-3-ols and benzoic acids), 254 nm (ellagic acid), 280 nm (furans and cinnamic acid), 315 nm (hydroxycinnamic acids and trans-resveratrol) and 360 nm (flavonoids). The RSD for the repeatability test (n55) of peak area and retention times were below 3.1 and 0.3%, respectively, for phenolics and below 1.0 and 0.2% for organic acids. The RSDs expressing the reproducibility of the method were higher than for the repeatability results but all below 9.0%. Method accuracy was evaluated by the recovery results, with averaged values between 80 and 104% for polyphenols and 97–105% for organic acids. The calibration curves, obtained by triplicate injection of standard solutions, showed good linearity with regression coefficients higher than 0.9982 for polyphenols and 0.9997 for organic acids. The LOD was in the range of 0.07–0.49 mg/L for polyphenols (cinnamic and gallic acids, respectively) and 0.001–0.046 g/L for organic acids (oxalic and lactic acids, respectively). The method was successfully used to measure and assess the polyphenolic fingerprint and organic acids profile of red, white, rose ´ and fortified wines.