3 resultados para Closed loop controllers
em Repositório Digital da UNIVERSIDADE DA MADEIRA - Portugal
Resumo:
Research on inverted pendulum has gained momentum over the last decade on a number of robotic laboratories over the world; due to its unstable proprieties is a good example for control engineers to verify a control theory. To verify that the pendulum can balance we can make some simulations using a closed-loop controller method such as the linear quadratic regulator or the proportional–integral–derivative method. Also the idea of robotic teleoperation is gaining ground. Controlling a robot at a distance and doing that precisely. However, designing the tool to takes the best benefit of the human skills while keeping the error minimal is interesting, and due to the fact that the inverted pendulum is an unstable system it makes a compelling test case for exploring dynamic teleoperation. Therefore this thesis focuses on the construction of a two-wheel inverted pendulum robot, which sensor we can use to do that, how they must be integrated in the system and how we can use a human to control an inverted pendulum. The inverted pendulum robot developed employs technology like sensors, actuators and controllers. This Master thesis starts by presenting an introduction to inverted pendulums and some information about related areas such as control theory. It continues by describing related work in this area. Then we describe the mathematical model of a two-wheel inverted pendulum and a simulation made in Matlab. We also focus in the construction of this type of robot and its working theory. Because this is a mobile robot we address the theme of the teleoperation and finally this thesis finishes with a general conclusion and ideas of future work.
Resumo:
This work presents a RP-HPLC method for the simultaneous quantification of free amino acids and biogenic amines in liquid food matrices and the results of the application to honey and wine samples obtained from different production processes and geographic origins. The developed methodology is based on a pre-column derivatization with o-phthaldialdehyde carried out in the sample injection loop. The compounds were separated in a Nova-Pack RP-C18 column (150 mm × 3.9 mm, 4 μm) at 35 °C. The mobile phase used was a mixture of phase A: 10 mM sodium phosphate buffer (pH 7.3), methanol and tetrahydrofuran (91:8:1); and phase B: methanol and phosphate buffer (80:20), with a flow rate of 1.0 ml/min. Fluorescence detection was used at an excitation wavelength of 335 nm and an emission wavelength of 440 nm. The separation and quantification of 19 amino acids and 6 amines was carried out in a single run as their OPA/MCE derivatives elute within 80 min, ensuring a reproducible quantification. The method showed to be adequate for the purpose, with an average RSD of 2% for the different amino acids; detection limits varying between 0.71 mg/l (Asn) and 8.26 mg/l (Lys) and recovery rates between 63.0% (Cad) and 98.0% (Asp). The amino acids present at the highest concentration in honey and wine samples were phenylalanine and arginine, respectively. Only residual levels of biogenic amines were detected in the analysed samples.