64 resultados para Permanganate-periodate


Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is neither comprehensive nor appropriate that the bioremediation of a benzo[a]pyrene (BaP)-contaminated environment be assessed only by its high degradation extent because its metabolites' chemical structures are similar to the parent compound and maybe equally toxic. Therefore, further degradation of BaP metabolites is significant. Three methods, combining the Zoogloea sp. with potassium permanganate, combining the Zoogloea sp. with H2O2, Zoogloea sp. alone, were investigated to degrade cis-BP4,5-dihydrodiol and cis-BP7,8-dihydrodiol, which are the metabolites of BaP formed by bacterium-Zoogloea sp. Optimum parameters of degradation in the best method are that: of the three methods, coupling the Zoogloea sp. and KMnO4 is the best; compared with cis-BP7,8-dihydrodiol, cis-BP4,5-dihydrodiol is the more liable to be accumulated in pure cultures; the degradation effect of the two metabolites is optimal when the initial concentration of KMnO4 in the cultures is 0.05%; initial concentration of cis-BP4,5-dihydrodiol and cis-BP7,8-dihydrodiol is 4 mg L−1, 8 mg L−1, respectively; cometabolic substance is salicylic acid or sodium succinate. The degradation extent of cis-BP4,5-dihydrodiol and cis-BP7,8-dihydrodiol using combining the Zoogloea sp. and KMnO4 reach 76.1% and 85.9% after 12 days of cultivation, respectively, which were more than twice compared with conventional method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A sequential injection analysis procedure with dual-reagent chemiluminescence detection was applied to the screening of street drug seizure samples for the presence of heroin. The chemiluminescence reagents (acidic potassium permanganate and tris(2,2′-bipyridine)ruthenium(III)) were aspirated from either side of a sample aliquot that was sufficiently large to prevent interdispersion of the reagent zones, and therefore two different chemical reactions could be performed simultaneously at either end of the sample zone. The presence of heroin in seizure samples was indicated by a strong response with the tris(2,2′-bipyridine)ruthenium(III) reagent and confirmed by a significant increase in the response with the permanganate reagent when the sample was treated with sodium hydroxide to hydrolyse the heroin to morphine. Nicomorphine (a morphine-derived pharmaceutical) was synthesised and tested under the same conditions. The responses with the permanganate reagent were similar to those for heroin, which supports the proposed chemical basis for the test. However, the responses with tris(2,2′-bipyridine)ruthenium(III) were far lower for nicomorphine than heroin (approximately 5-fold for the samples that had not been hydrolysed).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A review with 98 references. The determination of the opium poppy (Papaver somniferum) alkaloids and their semi-synthetic derivatives has important applications in industrial process monitoring, clinical analysis and forensic science. Liquid-phase chemiluminescence reagents such as tris(2,2′-bipyridyl)ruthenium(II) and acidic potassium permanganate exhibit remarkable sensitivity and complementary selectivity for many P. somniferum alkaloids, which has been exploited in the development of a range of analytical procedures using flow analysis, high-performance liquid chromatography, capillary electrophoresis and microfluidic instrumentation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although potassium permanganate [Mn(VII)] has been used extensively as a chemiluminescence reagent for many decades, other manganese-based oxidants have only recently been explored for this purpose. There is strong evidence to suggest that, like permanganate, manganese(III) and manganese(IV) oxidants react with many molecules to produce an excited manganese(II) species that emits light. However, these reagents differ markedly in terms of selectivity, and possess characteristics that provide new avenues for detection, such as the immobilisation of solid manganese dioxide, the production of ‘soluble’ manganese(IV) nanoparticles, and the electrochemical generation of manganese(III). In this review we examine the emergence of these alternative manganese oxidants as chemiluminescence reagents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a new chemiluminescence detector, with solution channels that have been machined into a Teflon disk and sealed with a sapphire window. The configuration of the flow cell can be conveniently modified by replacing the Teflon disk. A comparison of some existing and novel designs, using the chemiluminescence reaction of morphine with acidic potassium permanganate and the bioluminescence reaction of ATP with the commercially available “BacTiter-Glo” reagent, has revealed that a serpentine channel allows greater quantities of light to be captured than a spiral channel, due to more efficient mixing of the analyte and reagent solutions within the cell.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The health benefits of antioxidant-rich ‘Mediterranean’ type diets high in grain, olives and red wine are well recognised. Since these foodstuffs consist of a complex matrix of chemical components, to date, the primary challenge lies in prioritising and isolating molecules for a physiologically relevant cell culture assay to assess their human health benefits. Currently, the most common approach requires arduous sample fractionation into smaller ‘crude’ extracts, followed by costly cell culture assays, with the bioactive identified only after a positive response in the cell. The work presented within this poster demonstrates the potential for an acidified potassium permanganate chemiluminescence detector as a much simpler screening tool to identify the best bioactive candidates from a complex sample matrix.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chemiluminescence, the production of light from a chemical reaction, has found widespread use in analytical chemistry. Both tris (2, 2’-bipyridyl) ruthenium (II) and acidic potassium permanganate are chemiluminescence reagents that have been employed for the determination of a diverse range of analytes. This thesis encompasses some fundamental investigations into the chemistry and spectroscopy of these chemiluminescence reactions as well as extending the scope of their analytical applications. Specifically, a simple and robust capillary electrophoresis chemiluminescence detection system for the determination of codeine, O6-methylcodeine and thebaine is described, based upon the reaction of these analytes with chemically generated tris(2,2'-bipyridyl)ruthenium(III) prepared in sulfuric acid (0.05 M). The reagent solution was contained in a glass detection cell, which also held both the capillary and the cathode. The resultant chemiluminescence was monitored directly using a photomultiplier tube mounted flush against the base of the detection cell. The methodology, which incorporated a field amplification sample introduction procedure, realised detection limits (3a baseline noise) of 5 x 10~8 M for both codeine and O6-methylcodeine and 1 x 10~7 M for thebaine. The relative standard deviations of the migration times and the peak areas for the three analytes ranged from 2.2 % up to 2.5 % and 1.9 % up to 4.6 % respectively. Following minor instrumental modifications, morphine, oripavine and pseudomorphine were determined based upon their reaction with acidic potassium permanganate in the presence of sodium polyphosphate. To ensure no migration of the permanganate anion occurred, the anode was placed at the detector end whilst the electroosmotic flow was reversed by the addition of hexadimethrine bromide (0.001% m/v) to the electrolyte. The three analytes were separated counter to the electroosmotic flow via their interaction with a-cyclodextrin. The methodology realised detection limits (3 x S/N) of 2.5 x 10~7 M for both morphine and oripavine and 5 x 10~7 M for pseudomorphine. The relative standard deviations of the migration times and the peak heights for the three analytes ranged from 0.6 % up to 0.8 % and 1.5% up to 2.1 % respectively. Further improvements were made by incorporating a co-axial sheath flow detection cell. The methodology was validated by comparing the results realised using this technique with those obtained by high performance liquid chromatography (HPLC), for the determination of both morphine and oripavine in seven industrial process liquors. A complimentary capillary electrophoresis procedure with UV-absorption detection was also developed and applied to the determination of morphine, codeine, oripavine and thebaine in nine process liquors. The results were compared with those achieved using a standard HPLC method. Although over eighty papers have appeared in the literature on the analytical applications of acidic potassium permanganate chemiluminescence, little effort has been directed towards identifying the origin of the luminescence. It was found that chemiluminescence was generated during the manganese(III), manganese(IV) and manganese(VII) oxidations of sodium borohydride, sodium dithionite, sodium sulfite and hydrazine sulfate in acidic aqueous solution. From the corrected chemiluminescence spectra, the wavelengths of maximum emission were 689 ± 5 nm and 734 ± 5 nm when the reactions were performed in sodium hexametaphosphate and sodium dihydrogenorthophosphate or orthophosphoric acid environments respectively. The corrected phosphorescence spectrum of manganese(II) sulfate in a solution of sodium hexametaphosphate at 77 K, exhibited two peaks with maxima at 688 nm and 730 nm. The chemical and spectroscopic evidence presented strongly supported the postulation that the emission was an example of solution phase chemically induced phosphorescence of manganese(II). Thereby confirming earlier predictions that the chemiluminescence from acidic potassium permanganate reactions originated from an excited manganese(II) species. Additionally, these findings have had direct analytical application in that manganese(IV) was evaluated as a new reagent for chemiluminescence detection. The oxidations of twenty five organic and inorganic species, with solublised manganese(IV), were found to elicit analytically useful chemiluminescence with detection limits (3 x S/N) for Mn(II), Fe(II), morphine and codeine of 5 x 10-8 M, 2.5 x 10-7 M, 7.5 x 10-8 M and 5 x 10-8M, respectively. The corrected emission spectra from four different analytes gave wavelengths of maximum emission in the range from 733 nm up to 740 nm indicating that these chemiluminescence reactions also shared a common emitting species, excited manganese(II). Whilst several analytical problems were addressed in this thesis and answers to certain questions regarding the fundamentals of acidic potassium permanganate chemiluminescence were proposed, there are several areas that would benefit from further research. These are outlined in the final chapter of this thesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis encompasses the development of analytical instrumentation, software and chemical methodologies for the rapid determination of pharmaceuticals in process extracts. Sensitive detection of morphine, codeine, oripavine and thebaine was achieved by measuring the quantity of light emitted as a result of their reactions with potassium permanganate and tris(2,2'-bipyridyl)ruthenium(III).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

HPLC with acidic potassium permanganate chemiluminescence detection was employed to analyse 17 Cabernet Sauvignon wines across a range of vintages (1971–2003). Partial least squares regression analysis and principal components analysis was used in order to investigate the relationship between wine composition and vintage. Tartaric acid, vanillic acid, catechin, sinapic acid, ethyl gallate, myricetin, procyanadin B and resveratrol were found to be important components in terms of differences between the vintages.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The antioxidant profiles of various espresso coffees were established using HPLC with UV-absorbance detection and two rapid, simultaneous, on-line chemical assays that enabled the relative reactivity of sample components to be screened. The assays were based on (i) the colour change associated with reduction of the 2,2´-diphenyl-1-picrylhydrazyl radical (DPPH•); and (ii) the emission of light (chemiluminescence) upon reaction with acidic potassium permanganate. Results from the two approaches were similar and reflected the complex array of antioxidant species present in the samples. However, some differences in selectivity were observed. Chromatograms generated with the chemiluminescence assay contained more peaks, which was ascribed to the greater sensitivity of the reagent towards minor, readily oxidisable sample components. The three coffee samples produced closely related profiles, signifying their fundamentally similar chemical compositions and origin. Nevertheless, the overall intensity and complexity of the samples in both UV absorption and antioxidant assay chromatograms were aligned with the manufacturers description of flavour intensity and character.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have examined a range of new and previously described flow cells for chemiluminescence detection. The reactions of acidic potassium permanganate with morphine and amoxicillin were used as model systems representing the many fast chemiluminescence reactions between oxidising agents and organic analytes, and the preliminary partial reduction of the reagent was exploited to further increase the rates of reaction. The comparison was then extended to high-performance liquid chromatography separations of α- and β-adrenergic agonists, with permanganate chemiluminescence detection. Flow cells constructed by machining novel channel designs into white polymer materials (sealed with transparent films or plates) have enabled improvements in mixing efficiency and overall transmission of light to the photodetector.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Herein we explore modern fabrication techniques for the development of chemiluminescence detection flow-cells with features not attainable using the traditional coiled tubing approach. This includes the first 3D-printed chemiluminescence flow-cells, and a milled flow-cell designed to split the analyte stream into two separate detection zones within the same polymer chip. The flow-cells are compared to conventional detection systems using flow injection analysis (FIA) and high performance liquid chromatography (HPLC), with the fast chemiluminescence reactions of an acidic potassium permanganate reagent with morphine and a series of adrenergic phenolic amines.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The application of 'soluble' (colloidal) manganese(IV) for chemiluminescence detection is reviewed, focussing on papers published since the last comprehensive review of the subject in 2008. Advances in this reagent system include: the on-line formation of manganese(IV); new insight into the light-producing pathway and selectivity of the reagent; its application to assess total antioxidants in plant derived samples and oxidative stress in biological fluids and tissues; and the replacement of the formaldehyde enhancer with ethanol.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Previous applications of manganese(IV) as a chemiluminescence reagent have required the use of formaldehyde to enhance the emission intensity to analytically useful levels. However, this known human carcinogen (by inhalation) is not ideal for routine application. A wide range of alternative enhancers have been examined but to date none have been found to provide the dramatic increase in chemiluminescence intensities obtained using formaldehyde. Herein, we demonstrate that ethanol offers a simple, safe and inexpensive alternative to the use of formaldehyde for manganese(IV) chemiluminescence detection, without compromising signal intensity or sensitivity. For example, chemiluminescence signals for opiate alkaloids using 50-100% ethanol were 0.8-1.6-fold those using 2M formaldehyde. This innocuous alternative enhancer is shown to be a particularly effective for the direct detection of thiols and disulfides by manganese(IV) chemiluminescence, which we have applied to a simple HPLC procedure to determine a series of biomarkers of oxidative stress.