19 resultados para zigzag slab

em Deakin Research Online - Australia


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ab initio density functional calculations were performed to study finite-length zigzag (7, 0) @ (16, 0) double-walled carbon nanotubes (DWCNTs) with H-termination at the open ends. We find that such a DWCNT nanodot displays a very large magnetic moment at the zigzag edges and the ground state displays symmetric anti-ferromagnetic coupling. When an external electric field is applied along the direction of tube axis, a gap is opened for one spin channel, whereas another spin channel remains metallic, i.e. half metallicity occurs. Our results suggest an important new avenue for the development of CNT-based spintronic materials with enhanced properties. © 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Slab-girder bridges are widely used in Australia. The shear connection between reinforced concrete slab and steel girder plays an important role in composite action. In order to test the suitability and efficiency of various vibration-based damage identification methods to assess the integrity of the structure, a scaled composite bridge model was constructed in the laboratory. Some removable shear connectors were specially designed and fabricated to link the beam and slab that were cast separately. In this test, two static loads were acted in the 1/3 points of the structure. In the first stage, dynamic test was conducted under different damage scenarios, where a number of shear connectors were removed step by step. In the second stage, the static load is increased gradually until concrete slab cracked. Static tests were conducted continuously to monitor the deflection and loading on the beam. Dynamic test was carried out before and after concrete cracking. Both static and dynamic results can be used to identify damage in the structure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A key criterion by which any building will be judged when its environmental impact is assessed is its thermal performance. This paper describes the simulation of an office module in a three-storey university building in south eastern Australia. The module, located at the north-west corner of the top floor of the building, was chosen because it is likely to have the highest cooling load - a primary concern of energy conscious designers of commercial buildings for most parts of Australia.

In the paper, the initial key assumptions are stated, together with a description of a "reference" or base case, against which improvements in thermal performance were measured. The simulation process identified the major influences on thermal performance. This enabled changes in materials and construction, as well as basic design concepts to be evaluated. Features incorporated into the base case such as a metal roof and glazed walkway were found to have adverse influence on energy consumption, and were consequently rejected in preference for an improved design which included a hypocaust slab system on the roof of the office module. The final design was predicted to reduce the annual energy consumption for heating and cooling by 72% and 76% respectively.

La performance thermique est l'un des critegraveres cleacutes de l'eacutevaluation environnementale de tout bacirctiment. Cet article deacutecrit la simulation d'un module de bureau appartenant agrave un immeuble de trois eacutetages d'une universiteacute du sud-est de l'Australie. Ce module, situeacute agrave l'angle nord-ouest de l'eacutetage supeacuterieur du bacirctiment a eacuteteacute choisi car c'eacutetait lui qui, vraisemblablement, avait la charge de refroidissement la plus eacuteleveacutee, ce qui est une preacuteoccupation majeure des concepteurs conscients des problegravemes d'eacutenergie des bacirctiments commerciaux dans la plus grande partie du pays. Le processus de simulation a fait apparaicirctre trois influences principales sur la performance thermique par rapport agrave un cas de base. Cela a permis d'eacutevaluer les modifications apporteacutees aux mateacuteriaux et agrave la construction ainsi qu'aux avant-projets. Les caracteacuteristiques inteacutegreacutees dans le cas de base comme le toit meacutetallique et la passerelle vitreacutee avaient une influence neacutefaste sur la consommation d'eacutenergie et ont donc eacuteteacute rejeteacutees au beacuteneacutefice d'un concept ameacutelioreacute qui comprenait une dalle de type hypocauste sur le toit du module de bureau. Le concept final devrait reacuteduire la consommation annuelle d'eacutenergie pour le chauffage et le refroidissement de 72 % et 76 % respectivement, ce qui donne une ideacutee de la valeur ajouteacutee au processus de production agrave partir de proceacutedures avanceacutees de modeacutelisation et de simulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The characterization of the previously reported diorganotellurium oxides R2TeO (R = Ph (1) and p-MeOC6H4 (2)) was revisited by osmometric molecular weight determinations, 125Te NMR spectroscopy, and electrospray spectrometry (ESMS) in solution and by 125Te MAS NMR spectroscopy in the solid state. The single-crystal X-ray structure of 2 revealed a polymeric arrangement that features a zigzag configured Te-O backbone without any secondary Te···O interactions. In solution 1 and 2 exist predominantly as monomers but appear to be in equilibrium with higher oligomers to a minor extent.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Compression tests carried out on aluminium specimens showed that when the die was rotated the compression load dropped. A slab method is employed to examine this process. The load reduction is explained by the deviation of friction vector due to the relative circumferential movement between the die and the material. This mechanism is incorporated into a theoretical model and an expression is derived for compression pressure. Analytical solutions established compare favourably with experimental results. It is also shown that there is a limitation to the load reduction: the compressive load can never be lower than 70 percent of the yield limit.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Performance of advanced fabric energy storage systems has not been reported for Australian conditions. The influence pf slab thickness and air flow rate on the annual thermal load, and maximum heating and cooling demands for a typical office module using a ventilated hollow core concrete slab system has been investigated by simulation. Performance results for Melbourne are presented and comments made on other locations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is a growing interest in the use of advanced fabric energy storage (FES) systems in Australia. The influence of slab thickness and ventilation rate on the annual thermal load, and maximum heating and cooling demands for an office module using a ventilated hollow core concrete slab system has been investigated by simulation. Airflow through the panels was set at 1, 2 or 4 air changes per hour (ACH) for slab thicknesses of 205, 220 and 300 mm. These configurations were simulated using two different FES operational strategies for six capital cities in mainland Australia. The simulations show that FES systems can offer either energy and/or peak load savings in almost all locations investigated. Overall, compared to a conventional AC system, the tempering of incoming fresh air combined with night flushing of the FES system appears to be the most successful operational strategy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bis(3-endo-camphoryl)phosphinic acid (1) was prepared by the reaction of the lithium enolate of D-(+)-camphor and phosphorous trichloride followed by an oxidative work up. Compound 1 crystallizes from wet toluene as monohydrate 1·H2O, which was investigated by X-ray crystallography. Molecules of 1 are associated by strong hydrogen bonds giving rise to the formation of a supramolecular helix. The interior channel of the helix is filled by a one-dimensional (1D) string of water molecules that are also associated by hydrogen bonding. The 1D string adopts a twisted zigzag conformation. Although the hydrogen bond networks are not cross-linked both the screw of the helix and the twist of the 1D string of water molecules are left-handed (M) and controlled by the chiral camphoryl residues situated on the exterior of the helix. The overall supramolecular structure is strongly reminiscent of aquaporin-1, a significant membrane-channel protein responsible for the transport of water into the cells.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We demonstrated for the first time by ab initio density functional calculation and molecular dynamics simulation that C0.5(BN)0.5 armchair single-walled nanotubes (NT) are gapless semiconductors and can be spontaneously formed via the hybrid connection of graphene/BN Nanoribbons (GNR/BNNR) at room temperature. The direct synthesis of armchair C0.5(BN)0.5 via the hybrid connection of GNR/BNNR is predicted to be both thermodynamically and dynamically stable. Such novel armchair C0.5(BN)0.5 NTs possess enhanced conductance as that observed in GNRs. Additionally, the zigzag C0.5(BN)0.5 SWNTs are narrow band gap semiconductors, which may have potential application for light emission. In light of recent experimental progress and the enhanced degree of control in the synthesis of GNRs and BNNR, our results highlight an interesting avenue for synthesizing a novel specific type of C0.5(BN)0.5 nanotube (gapless or narrow direct gap semiconductor), with potentially important applications in BNC-based nanodevices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The cost of concrete ground-supported floor slabs represents a significant proportion of the total capital cost of industrial projects. There are many structural design issues that impact on the concrete contractors’ method of construction. This is becoming more apparent with the use of new high-technology levelling and trowelling equipment, which has significantly increased the pour and finishing rates, resulting in much faster slab construction times compared with the traditional methods of construction. Selection of both the design and the construction methods exerts a large influence on the initial cost. According to the results of the research reported in this paper, it may be possible to save between 2-4 per cent of the building cost if high technology solutions are incorporated into the design and construction process. This paper investigates cost issues that impact on the design and construction of ground-supported floors for industrial buildings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite Australia having a high diversity of freshwater crayfish species, the ecology of many of these species remains poorly known, particularly burrowing crayfish of the genus Engaeus. Biological information on colour, behaviour, burrow structure, associated burrow fauna and habitat of the East Gippsland Burrowing Crayfish Engaeus orientalis obtained during incidental observations in 2007 and 2008 is provided. The burrow structure took the form of radiating runways under a rock slab, while the burrow location was in a semi-disturbed site away from water. Both are atypical for this species.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a technique to detect the delamination between the steel bars and concrete in the reinforced concrete structures. The piezoelectric components are mounted on reinforcing bars that are embedded in RC structures as sensors and actuators to generate and record the signal, which is sensitive to the delamination between the steel bars and concrete. The experimental study is carried out on a concrete slab with different debonds between the rebars and concrete. The test results show that the delamination between the rebars and concrete can be detected with the embedded piezoelectric sensors and actuators.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An experimental investigation of the shear strengths of composite plate girders, with centrally placed rectangular web cutouts, is described. A series of tests is conducted on short‐span girders having conventional welded stud shear connectors, connecting the composite concrete slabs to the top flanges of the plate girders. These tests indicated that it is the tensile or pullout capacity of the connectors that is primarily responsible for sustaining the composite action under predominantly shear loading. Subsequently, a further series of tests is conducted on short‐span girders with bolted tension connectors, designed to offer negligible resistance to horizontal shear forces at the interfaces between the concrete slabs and plate girders, which confirmed the previous conclusion. Both series of tests indicate that if adequate connectors are provided between a plate girder and a composite concrete slab, the shear strength of the composite girder is significantly higher than that of the plate girder alone. A simple analytical model for predicting the shear strengths of composite plate girders is also presented, which shows satisfactory correlation with the test results.